검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 19

        2.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to the development of the industry, the importance of injection molded products is increasing in the fields of electricity, electricity, automobiles, etc. Through this experiment, the weight change of molded products according to the injection speed change during injection molding was investigated. As a result of the experiment, a statistical program was used to confirm that the pi control method produced about 69.2% more weight deviation than the dpi method and to adopt the null hypothesis that the p-value was less than 0.05 Injection speed affected the molded product.
        4,000원
        3.
        2019.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        본 연구는 1M Li2SO4 및 1M Na2SO4 수용액에서 CoSe 나노 입자의 전기 화학적 성능을 조사 하였다. CoSe 나노 입자의 전기 화학적 효율은 1M Na2SO4 전해질에서 더 높은 비정전 용량을 보여주는 결 과를 얻었고 이것은 주로 1M Na2SO4 용액의 벌크 전해질에서 수화 된 이온의 빠른 이동과 활물질에 의해 제공되는 낮은 전기 화학적 임피던스가 원인이라 사료된다. 또한, 순환 전압 전류법 안정성 실험에서 25 mV s-1의 스캔 속도로 1000 회 연속 순환 전압 전류 측정주기 후에도 각각 1M Na2SO4 및 1M Li2SO4에서 약 92 % 및 89 %의 특정 정전 용량의 유지를 보여주었다. 이 연구는 새로운 하이브리드 슈퍼 커패시터를 개발하기 위한 기초 데이터를 제공하며 비대칭 슈퍼 커패시터의 양극으로 사용될 수 있음을 시사한다.
        4,000원
        4.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the odor causing in the under-fired charbroiling restaurant was reported in literature investigation,pilot test and field experimental verification. The charbroiling restaurant causes odor complaints of Neighbors soefficient reduction method is requested. Acetaldehyde, ammonia, sulfur compound and the oil mist of white smokeare found to cause odor from the charbroiling restaurant. Pilot test results show that in the removal efficiency ofodor, Electrostatic Precipitation was 67.4%, absorption was 81.2%, adsorption was 74.2% and the ElectrostaticPrecipitation & Adsorption the hybrid system with 85.7% respectively. In the same condition of the hybrid system(Electrostatic Precipitation & Adsorption), the odor removal efficiency were higher when the design parameterssuch as the discharge voltage and current were high. The process efficiency were higher when as the implanterpole was cylindrical. However, the process efficiency rapidly reduced due to the contamination of the processcomponent or material, as the operating time of the equipment is increased. Therefore, fixed maintenance and repairof the equipment is found to be are very important, for long term operation. Therefore, as the experimental resultof this study, applying hybrid system removed odors caused in under-fired charbroiling restaurant which areunregulated, is more effective device that settle civil complaints and preserve environment.
        4,200원
        6.
        2009.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전력, 통신 등 다양한 주요 기간설비의 운영에 필수적인 전기판넬의 내진성능개선을 위하여 내진보강시스템을 개발하고, 이 시스템의 내진성능평가를 위하여 진동대시험을 수행하였다. 본 연구에서 개발된 전기판넬 내진보강시스템은 이중바닥시스템(Access floor) 상에 설치된 전기판넬을 대상으로 운전하에서 무정전, 무이설 방식으로 내진보강이 가능하다는 장점을 지니고 있다. 진동대시험을 통해 전기판넬 내진보강시스템의 성능평가를 위하여 지진하중으로서 건물 내 여러 층에 설치되는 전기판넬의 특성을 고려하여 포괄응답스펙트럼을 입력하였다. 진동대시험은 널리 상용화되어 있는 스틸과 우드판넬 등 두 형식의 이중바닥시스템과 일반 전기판넬을 대표할 수 있는 동특성이 다른 두 종류의 전기판넬을 고려하여 총 4회 수행하였다. 진동대시험결과, 내진보강시스템은 진동대시험 중 및 후에도 전도 등으로 인한 전기판넬의 파손을 방지하는 등 전기판넬의 내진안전성을 확보하여 주는 것으로 나타났다. 따라서, 이중바닥시스템 상에 설치된 전기판넬에 개발된 내진보강시스템을 적용하는 경우, 지진으로 인한 전기판넬의 파손을 효과적으로 방지하여, 국내 주요 기간설비의 안정적 운영에 크게 기여할 수 있을 것으로 판단된다.
        4,000원
        8.
        1998.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Al alloy anode is mostly used for protecting marine structures such as pier steel piles and ship's body. Recently it has been reported that the life of Al alloy anode has been shortened significantly than the original design life. It is suggested that the suspected reasons for this problem mentioned above seems to be the improper protection design of alloy of anode on sea water regardless of environmental facotrs such as flow rate, temperature, contamination degree etc. However there is few paper about to the sea water contamination degree affecting to the life of Al alloy anode. In this study, the property of Al alloy anode was investigated as a parameter of sea water contamination degree such as variation of pH 2, 4, 6, 8, 10 and each sea port's contaminated waters.
        4,000원
        9.
        1990.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이상과 같이 엑튜에이터의 동특성 해석을 행하고 PID 제어기 및 최적 제어기를 설계하여 응답시뮬레이션을 한 결과 다음과 같은 결론을 얻었다. 1) 엑튜에이터 부의 시정수는 엔진 부의 시정수에 비해 아주 작아 생략하여 제어계를 구성할 수 있다. 2) 한계 감도법에 의해 PID 제어기를 시뮬레이션 한 결과 PID 제어 가버너는 전반적으로 오버슈트가 크고 중속 및 고속 상태에서는 정정시간이 비교적 짧지만 저속에서는 정상 상태에 도달하는데 상당한 시간이 걸린다. 3) 중량 matrix를 적당히 선택하여 최적 피이드 백 게인을 구한 후 마이크로 프로세서에 저장하여 제어기를 구성하면 PID 제어기 보다 양호한 응답 특성을 갖는 제어기를 설계 할 수 있다.
        4,500원
        10.
        2019.07 KCI 등재 서비스 종료(열람 제한)
        산업화, 도시화로 인해 수자원의 오염이 악화 되면서 기존에 염소를 이용한 정수처리 방법으로는 깨끗한 물을 공급하는데 어려운 실정이다. 이에 오존을 이용한 고도정수 처리 시설의 도입이 증가하고 있다. 그러나 기존의 방수⋅방식 공법으로 사용되는 에폭시계 방수⋅방식제 및 스테인리스는 오존의 강력한 산화력으로 인해 열화되어 박리 등 문제 발생하였으며, 콘크리트까지 영향을 미쳐 내구성 저하의 원인이 된다. 이에 따라 본 연구에서는 내오존성 및 내화학성이 뛰어난 금속 패널을 기존의 시공법 보다 손쉬운 방법으로 시공하기 위한 방법으로 금속용사 공법을 이용하여 수처리 시설 콘크리트 구조물의 열화를 원천적으로 방지하기 위한 마감공법 개발 연구의 일원으로 용사금속 종류 에 따른 내오존성 평가를 실시하였으며, 실제 하수처리장 환경에서의 전기화학적 안정성능 평가를 실시하였다. 실험결과 용사금속 Ti이 용사 후에도 내오존성이 뛰어난 것으로 나타났으며, 하수처리장 환경에서의 전기화학적 안정성능 평가 결과 용사금속 Ti가 403.83k∙ Ω∙cm2의 가장 높은 분극저항을 나타남으로써 높은 수준의 내구성을 확보하는 것을 확인할 수 있었다.
        11.
        2016.04 서비스 종료(열람 제한)
        Recently, Advanced water treatment facilities with Ozone are being introduced domestically. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. Therefore, in this study, As a one of studies for improving durability of advanced water treatment plant applied by metal spray system, electrochemical corrosion protection of metal spraying film according to surface treatment in pH 5 acid solution which is similar to pH concentration in real ozone treatment was evaluated..
        12.
        2013.10 서비스 종료(열람 제한)
        This study is based on the electrochemical theory which aims to get the quantitative evaluation about corrosion protection of Zn-Sn metal spray method. The various existing corrosion resistance method and various mixture ratio of Zn-Sn metal spray method is applied with structural steel which is measured change of polarization resistance and corrosion potential. So corrosion protection of Zn-Sn metal spray method is tested. Consequently, coating side of Zn-Sn metal spray method was lower than electric potential of a structural steel adhesion side. So, Galvanic Protection of Zn-Sn metal spray found that structural steel advanced system. Accordingly, Zn-Sn metal spray method is expected as corrosion protection technology excellent in corrosion prevention of structural steel.
        13.
        2013.09 KCI 등재 서비스 종료(열람 제한)
        In this study, the inhibitive effect of electrochemical treatment subjected to fresh and hardened concrete and literature reviews in terms of the treatment were performed. In hardened concrete, chloride ions are mixed during casting to destroy the passivity of steel, and then the current was provided for 2 weeks with 250, 500 and 750 mA/m2. After completion of electrochemical treatment, the extraction of chloride ions was quantified and repassivation of steel was observed. Simultaneously, the equated levels of current density for 2 weeks were applied to fresh concrete. Steel-concrete interface in concrete was observed by BSE image analysis and the concrete properties in terms of the diffusivity of chloride ions and the resistance of steel corrosion was measured. As the result, electrochemical treatment is very effectiveness to rehabilitate the passive film on the steel surface and 63-73% of chloride ions in concrete were extracted by the treatment. As the treatment was applied to fresh concrete, the resistance of steel corrosion was improved due to the densification of Ca(OH)2 layers in the vicinity of steel. However, an increase in the current density resulted in an increase in surface chloride content of concrete.
        14.
        2013.07 KCI 등재 서비스 종료(열람 제한)
        In this study, corrosion potential (Ecorr), corrosion rate, and polarization resistance were measured aimed at inorganic inhibitors (passive film type) and organic inhibitors (absorption type). The experiment was conducted using potentiostat for the variable molar ratio and chloride ion concentration of the components of inhibitors in an aqueous solution of saturated calcium hydroxide targeting corrosion. As a result, it was possible to ensure an anticorrosive performance of at least a 1.2 molar ratio of inorganic inhibitors. Also, the organic inhibitors ensured the prevention of the anticorrosive performance of at least about a 0.3 molar ratio. It also showed the tendency that between polarization resistance and corrosion rate, Ecorr and corrosion rate is inversely proportional to the linear. Conversely, the tendency between polarization resistance and Ecorr is proportional to the linear. Also, a distinct difference in organic and inorganic inhibitors’ relationship to Ecorr, corrosion rate, and polarization resistance was not shown.
        15.
        2013.04 서비스 종료(열람 제한)
        Electrochemical treatments have been applied to many concrete structures. However, excessive current density degrades the bond strength by the change of microstructure at the steel-concrete interface. In this study, the optimal current density of electrochemical treatment without a influence on the bond strength could be derived from related literatures.
        16.
        2013.04 서비스 종료(열람 제한)
        Marine bridges are deteriorated due to the exposure under marine environment. The structure deterioration occurred by corrosion of steel in concrete is mainly relevant to chloride in seawater. The cathodic protection technique is an unique measurement to stop the corrosion of steel. In this study, the detail maintenance strategy of cathodic protection system in KEC's experience is introduced.
        17.
        2012.05 서비스 종료(열람 제한)
        This study informs regarding application to electric protection by using piezoelectric material which is one of the energy harvesting system in bridge. It can transform from strain energy to electricity energy by using piezoelectric material as strain energy always occurs in bridge. This paper suggests that electricity energy occurred from piezoelectric material can use cathodic protection by power impressed methods for anti corrosion of reinforcement bar, steel and so on.
        18.
        2012.02 서비스 종료(열람 제한)
        현재 사용되는 교량 강재의 부식 방식은 도장 방식이며, 이는 도막의 구성물이 고분자물질로 이루어져 있기 때문에 그 기능이 감소되거나 상실된다는 문제점 및 교량의 하부 교대 및 교각, 교좌 장치 등의 안전 점검 및 유지 관리에 어려움이 있다. 본 논문에서는 압전소자 및 진동 발전을 이용한 에너지 회수기술로서 발생된 녹색 에너지를 이용하여 철근 부식, 강합성 교량 및 강교량의 부식에 대해 전기 방식 중 외부 전원법의 활용에 대한 기초 연구를 하였다. 지하철의 경우 도상에서 평균 1km 당 자갈도상에서 5.76MW·h, 콘크리트 도상에서 0.58MW·h 의 전력이 발생 되고, 차량의 하중을 이용한 압전 소자로 발생되는 전력은 약 4차선 도로 기준 1km당 약 166kW가 발생된다. 강재 방식 중 외부 전원법의 애노드 강재 보호 반경은 약 2m 이며 6~12볼트의 직류 전기가 필요로 한다. 본 연구에서는 이러한 녹색 에너지에서 발생되는 전력을 이용하여 외부 전원법의 전류 공급을 하여 교량 강재의 부식 방식 및 효율적으로 유지관리 하는 시스템을 제안하였다.