검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 19

        1.
        2022.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Research is being actively conducted on the continuous thin plate casting method, which is used to manufacture magnesium alloy plate for plastic processing. This study applied a heat transfer solidification analysis method to the melt drag process. The heat transfer coefficient between the molten magnesium alloy metal and the roll in the thin plate manufacturing process using the melt drag method has not been clearly established until now, and the results were used to determine the temperature change. The estimated heat transfer coefficient for a roll speed of 30 m/min was 1.33 × 105 W/m2·K, which was very large compared to the heat transfer coefficient used in the solidification analysis of general aluminum castings. The heat transfer coefficient between the molten metal and the roll estimated in the range of the roll speed of 5 to 90 m/min was 1.42 × 105 to 8.95 × 104 W/m2·K. The cooling rate was calculated using a method based on the results of deriving the temperature change of the molten metal and the roll, using the estimated heat transfer coefficient. The DAS was estimated from the relationship between the cooling rate and DAS, and compared with the experimental value. When the magnesium alloy is manufactured by the melt drag method, the cooling rate of the thin plate is in the range of about 1.4 × 103 to 1.0 × 104 K/s.
        4,000원
        2.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Double slug interaction in downward-facing nucleate boiling was studied to investigate its effect on boiling performance. Two heating surfaces were individually controlled to apply heat flux while their boiling performance were measured. A slug generated from upper heater affect on lower heater to make convectional flow by suction following departure of slug. Moreover, it showed to reduce hovering time of slug bubble on lower heater because it could help bubble departure on lower heater. Meanwhile, a slug generated from lower heater affected on upper heater to make convectional flow by sweeping. However, it showed to increase hovering time of slug bubble on upper heater, because they collapsed to each other. So, the slugs from lower heater enhanced the boiling performance of upper heater with low heat flux condition, but reduced the performance of it with high heat flux condition.
        4,000원
        3.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the effect of thermal grease and heat sink material of cooler on CPU temperature was measured and compared with LinX(v0.9.6) and HWMonitor.When the computer is booted without thermal grease applied, the CPU temperature rises rapidly, and the CPU temperature reaches 100℃ after 60 seconds for aluminum heat sink and 140 seconds for copper heat sink. The CPU temperature is lower as the thermal conductivity coefficient of thermal grease is higher, and the CPU temperature is lower when the thermal conductivity coefficient of the cooler is higher. In addition, when using a thermal grease and a heat sink with a high coefficient of thermal conductivity, the cooler rpm can be lowered, which is considered to be advantageous in terms of system stability and energy saving.
        4,000원
        4.
        2020.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대류열전달은 겨울철 온실 열손실의 중요한 원인이 되며, 일반적으로 복사열에 의한 손실보다 더 크다. 스크린의 대류열전달계수를 자연상태에서 측정한 연구가 수행된 바는 있지만 상하면의 재질이 동일하고 공극이 없는 스크린에 대해서는 적용을 할 수 없는 방법이다. 이러한 재질의 스크린은 한국에서 많이 사용되고 있으나 대류열전달 특성을 파악하는데 많은 어려움이 있는 실정이다. 본 연구에서는 공극이 없는 3가지 종류의 스크린에 대해 대류열전달계수를 구하였으며, 계수를 산정하기 위하여 복사열수지 이론에 근거하여 산정방법을 개발하였다. 실험장치에 스크린을 설치하고 일사량, 장파복사량, 대기온도, 스크린 및 흑색천의 표면온도, 풍속 등을 측정하였다. 스크린의 표면온도와 주변온도의 차이에 따른 대류열전달계수를 산정하였다. 풍속이 거의 없는 상태에서 온도의 차이가 증가함에 따라 계수는 감소하는 것으로 나타났다.
        4,200원
        5.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        겨울철에 열손실을 줄이기 위해 많은 온실에서 보온커튼을 사용하고 있다. 그러나 적절한 보온커튼을 선택할 때 판단 자료로 활용할 수 있는 명확한 기준이 없는 실정이며 이를 위해서는 보온재의 보온 특성에 대한 정량적인 값이 필요하다. 본 연구에서는 BES를 사용하여 보온커튼의 관류열전달계수를 산정하는 시뮬레이션 모델을 개발하였다. 일중 및 이중 PE필름 피복에 대한 관류열전달계수의 실험값을 사용하여 시뮬레이션 결과를 검증하였다. 검증된 모델을 사용하여 문헌에서 제시된 각종 열적 특성을 가진 보온커튼에 대한 관류열전달계수를 산정하고 비교분석하였다. 개발된 시뮬레이션 모델은 다양한 보온커튼의 관류열전달계수를 산정하는데 활용될 수 있을 것이며, 제시된 관류열전달계수는 보온커튼의 성능을 정량적으로 비교하는데 유용하게 활용 될 수 있을 것으로 판단된다.
        4,000원
        6.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Acidic and basic mixtures of odorous compounds are commonly emitted from various sources, and, in an absorption process, pH conditions in the liquid phase significantly affect the performance. In this study, the effect of pH on mass transfer in a bubble column reactor was evaluated using hydrogen sulfide and ammonia as a model mixture. Their mass transfer coefficients were then calculated. Furthermore, the total mass transfer coefficients as a function of pH were evaluated, and the experimental data were fitted into an empirical equation using dimensionless numbers. The mass transfer rates of hydrogen sulfide, the non-ionic form, increased dramatically with increasing pHs, while those of ammonia were almost unchanged because of its high solubility. As a result, a favorable pH condition for less soluble compounds must be selected to achieve high absorption capacity. The total mass transfer rates, which took into account pH effects as well as all the non-ionic and ionic constituents together, were found to be from 2.2 to 2.4 × 10−3 min−1 for hydrogen sulfide and ammonia, respectively, and they were almost constant at different pHs. The empirical equations, which were derived to obtain the best fit for the total mass transfer rates, implied that a method to increase diffusivity of each compound should be applied to improve overall mass transfer. In addition, when using the empirical equation, a mass transfer coefficient at a given set of pH and operating conditions can be calculated and used to design a water scrubbing process.
        4,000원
        8.
        2015.12 구독 인증기관 무료, 개인회원 유료
        This study calculated the overall heat transfer coefficient (U-value) of greenhouse covering materials with thermal screens using a simulation model and then estimated the validity of the calculated results by comparison with measured values. The U-value decreased gradually as the thickness of the air space between the double glazing increased, and then remained essentially constant at thicknesses exceeding 25 mm. The U-value also increased with the difference in temperature between the inside and outside of the hot box. The vigorous convective heat transfer between two plastic films caused unsteady heat flow and then created a nonlinear temperature distribution in the air space. The distance did not affect the U-value at distances of 50~200 mm between the plastic covering and thermal curtain. The numerical calculation results, with and without sky radiation, were in accord with the experimental results for a 30°C temperature difference between the inside and outside of the hot box. In conclusion, a reliable Uvalue can be calculated for a temperature difference of 30°C or more between the inside and outside of the hot box.
        4,000원
        9.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 일중피복온실의 피복재에 대하여 우리나라 환경에 적합한 관류열전달계수를 산정하는 방법을 찾아내고 검증하여 다양한 온실조건 및 환경조건에서 관류열전달계수를 산정할 수 있는 모델을 제시하는 것이다. 온실내부 및 외부온도와 피복재 표면온도와의 상관관계를 분석한 결과 주간 및 야간 온도를 모두 고려하였을 때보다 야간온도만을 고려하였을 경우가 상관성이 훨씬 더 높은 것으로 나타났다. 피복재의 표면온도가 온실의 외부온도보다는 내부온도와 상관성이 더 높은 것으로 나타났다. 관류열전달계수를 산정하는데 사용된 5가지 종류의 대류 및 복사열전달계수 산정식을 비교한 결과 Kittas가 제안한 대류 및 복사열전달계수 산정식이 가장 적합한 것으로 나타났다. 피복재 표면온도의 측정값과 계산 값의 상관성을 분석한 결과 직선의 기울기는 1.009이고 절편은 0.001이며 결정계수가 0.98로 나타나 본 연구에서 제시된 관류열전달계수 산정모델이 신뢰성이 있음을 확인할 수 있었다. 온실내부로부터 피복재 내부표면으로 전달되는 열흐름량의 경우 모든 풍속구간에 대해 대류열전달량이 복사열전달량보다 더 컸으며 풍속이 증가할수록 그 차이가 증가하였다. 외부표면에서 손실되는 열흐름량의 경우 풍속이 낮을 때에는 대류열전달량에 비해 복사열전달량이 더 컸으나 풍속이 증가함에 따라 그 차이는 점점 줄어들어 풍속이 높을 때에는 대류열전달량이 더 커지는 것으로 나타났다. 피복재 외부 표면의 대류열전달량은 내부표면의 대류열전달량에 직선적으로 비례하여 증가하는 것으로 나타났다. 풍속이 증가함에 따라 관류열전달계수는 증가하고 피복재의 표면 온도는 감소하는 것을 확인할 수 있었고, 변화추세를 보면 관류열전달계수는 거듭제곱함수와 그리고 표면온도는 로그함수와 잘 일치하였다.
        4,000원
        10.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 상업용 온실 피복재의 관류열전달계수를 산정히는데 필요한 기초자료를 제공하기 위하여 최근 국내에 많이 보급되어 사용되고 있는 플라스틱필름으로 피복된 온실에 대해 관류열량을 측정하고 관류열전달계수의 변화를 분석하였으며 그 결과를 요약하면 다음과 같다. 온실 내외부 온도차에 따른 관류열전달계수의 변화를 분석한 결과 피복의 층수에 따라 안정된 관류열전달계수를 나타내게 되는 온실 내외부 온도차의 값이 다르게 나타났기 때문에 온실 피복재에 대한 관류열전달계수를 결정할 때에는 피복층수별로 안정된 값을 나타내는 온실 내외부 온도차 범위에서의 관류열전달계수를 채택하여야할 것이다. 온도차이에 따른 관류열전달계수의 변화 경향은 기존의 연구결과와 잘 일치하였으나 안정된 값을 나타내는 온도차이의 구체적인 값은 다르게 나타났기 때문에 이에 대한 추가적인 연구가 필요할 것으로 판단된다. 풍속에 따른 관류열전달계수의 증가율은 연구자에 따라 많은 차이가 있음을 알 수 있었으며, 이중피복온실이나 커튼을 설치한 온실과 같이 보온성을 높인 온실은 일중피복온실에 비해 풍속에 따른 관류열 손실이 더 작다는 사실을 확인할 수 있었다. 관류열전달계수의 기존 연구결과들을 분석한 결과 연구자에 따라 값이 차이가 있었기 때문에 국내 온실의 정확한 난방부하량을 산정하는데 필요한 적절한 관류열전달계수를 제시하기 위해서는 우선 측정을 위한 표준화된 환경기준이 마련될 필요가 있으며, 또한 국내에서 실제로 사용되고 있는 주요 피복재별로 구체적인 관류열전달계수가 구해져야 할 것이다.
        4,000원
        11.
        2010.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        고준위 방사성 폐기물 처분장의 경우 폐기물의 방사성 붕괴에 의해 열이 발생되며, 암반을 통한 열전달 에 의해 처분장 주변 환경이 변화됨으로써 처분장의 안전성에 영향을 미칠 수 있다. 그러므로 지하 처분장 대기의 열전달계수를 결정하는 것은 매우 중요하다. 이에 본 연구에서는 Korea Atomic Energy Research Institute Underground Research Tunnel (KURT)에서 내부 환경 인자들의 측정을 통해 강제대류시 열전달계수를 산정하였다. 실험을 위해 KURT 내 히터구간의 막장 벽면에는 길이 2 m, 용량 5 kw의 히터를 삽 입하여 암반 내부를 90℃로 가열하였고, 외부와 연결된 급기용 팬에 의해 신선한 공기를 공급하였다. 연구 결과, 외부공기 공급 후 히터구간 대기의 기류속도는 평균 0.81 m/s로 측정되었고 레이놀즈수는 약 310,000 340,000의 값을 나타냈다. 그리고 강제대류조건에서 히터구간 내 계절별 열전달계수는 각각 여 름철 7.68 W/m2·K와 겨울철 7.24 W/m2·K의 수치를 나타냈다.
        4,200원
        12.
        2003.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        파양한 구조물의 정적해석에서 매트릭스구조해석법은 가상 폭넓게 사용되고 있는 강력한 해석기법이다. 그러나 이 방법으로 많은 수의 자유도를 갖는 구조물을 정확히 해석하기 위해서는 많은 계산 메모리와 빠른 처리 능력을 갖춘 고성능 컴퓨터를 필요로하는 취약점이 있다. 따라서 매트릭스구조해석법으로 많은 수의 자유노를 갖는 구조물을 퍼스널 컴퓨터 상에서 정확히 해석하기에는 곤란한 경우가 많다. 매트릭스구조해석법치 이러한 취약점을 극복하기 위하여, 저자들은 전달강성계수법을 제안한다. 전달강성계수법은 해석대상 구조물에 대한 강성계수의 전달에 기본 개념을 두고 있으am로 퍼스널 컴퓨터에 매우 적합한 해석기법이다. 본 논문에서는 골조추조물에 대한 정적해석 알고리듬을 전달강성계수법으로 정식화한다. 그리고 전달강성계수법, NASTRAN, 매트릭스구조해석법 그리고 해석해에 의한 계산 결과들의 비교를 통해 전달강성계수법의 유효성을 확인한다.
        4,000원
        15.
        1991.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        직선상 2층 구조물의 임의의 절점에 변위벡터가 불연속인 죠인트 요소를 갖는 경우, 면내 굽힘 자유진동을 해석하기 위한 알고리즘을 전달영향계수법에 의해 정식화하고, 간단한 모델에 의해 수치실험을 행한 결과, 다음과 같이 요약할 수 있다. (1) 전달영향계수법은 종래의 전달매트릭스법에 비해 계산정도 및 계산속도 양면에서 우수함을 확인할 수 있다. (2) 구조물의 임의의 중간 절점에서 상태벡터량(횡변위, 각변위, 전단력 및 모멘트 등) 중 일부의 물리량이 불연속성을 갖더라도, 알고리즘 자체를 변화시켜야 하는 전달매트릭스법과는 달리, 스프링전수 값의 조절만으로 간단히 처리할 수 있어, 알고리즘의 일반화 및 프로그램의 범용화가 가능하다. (3) 전달영향계수법에서는, 구조물의 중간에 반고정지지와 같은 단단한 탄성지지부가 다수 존재하는 경우에도, 기본적인 알고리즘을 변경할 필요 없이 전단 및 회전 스프링정수에 적당한 값을 대입하는 것만으로 중간조건에 대응시킬 수 있고, 모든 경계조건도 마찬가지로 처리할 수 있다.
        4,000원
        17.
        2018.05 서비스 종료(열람 제한)
        지구온난화 문제와 유기성 폐기물의 처리문제는 해결이 시급한 환경문제이며, 바이오가스는 이러한 문제를 동시에 해결할 수 있는 장점으로 크게 주목받고 있다. 그러나 바이오가스 중에 함유된 황화수소나 암모니아는 발전설비의 부식 및 대기오염을 유발하기 때문에 전처리가 필수적이다. 기체상 오염물질의 처리를 위한 다양한 기술 중 수세정(scrubber)은 기액간의 접촉을 유도하여 액상으로 오염물질을 흡수 및 제거하는 기술로 널리 활용되고 있는 기술이다. 또한 황화수소나 암모니아는 물에 대한 용해성이 높기 때문에 수세정 공정을 활용하기 유리하다. 그러나 고농도의 황화수소나 암모니아를 효율적으로 처리하기 위해 가성소다 등의 약품을 세정액에 용해시켜 활용하는 것은 세정 후 약액의 2차 처리문제를 야기한다. 이에 본 연구에서는 이러한 문제점을 해결하기 위해 수세정공정에 전기화학적으로 생성된 free chlorine을 유입시켜 흡수된 황화수소 및 암모니아를 산화함으로써 물질전달률을 높일 수 있도록 하고자 하였다. 이를 위해서는 황화수소와 암모니아의 물질전달률의 평가가 필수적이며, 본 연구에서는 10mM의 NaCl이 용해된 수용액에 1,000 ppm의 황화수소와 암모니아가 4 L/min의 유량으로 단독으로 유입될 때와 동시에 유입될 때의 물질전달계수를 비교하였다. 수용액의 pH가 8일 때 황화수소 단독 물질전달계수(KLa-H2S)는 0.1214 min-1이고, 암모니아 단독 물질전달계수(KLa-NH3)는 9.9×10-5 min-1으로 산정되었다. 그러나 황화수소와 암모니아 각 1,000 ppm이 동시에 유입되었을 때 KLa-H2S는 0.2247 min-1, KLa-NH3는 1.6×10-4 min-1으로 물질전달속도가 상승하였다. 따라서 수세정 공정에서 황화수소와 암모니아의 동시유입이 제거율의 향상에 도움이 되는 것으로 나타났다. 또한, free chlorine에 의해 액상 황화수소와 암모니아가 제거된다면 추가적인 물질전달계수의 향상이 가능하다.
        19.
        1997.02 KCI 등재 서비스 종료(열람 제한)
        Varing the flow velocity of solution and particle diameter, the mass transfer coefficient of the local electrode on current feeder has been measured in an empty flow reactor, an inert fluidized bed electrode reactor, and an active fluidized bed electrode reactor. It had its maximium value when the bed porosity was 0.6 to 0.65 and decreased with increasing the height of local electrode. The mass transfer coefficient was found to be high especially when bigger particle was fluidized. Electrochemical deposition of copper dissolved in the synthesized wastewater has been performed in the active fluidized bed electrode reactor. The deduction rate was higher than 90% and the residual concentration of copper decreased to less than 5ppm.