검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 59

        3.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study evaluates the performance of three theoretical models for correcting dynamic pressure affected by tube length. The experiments involved measuring sinusoidal pressure waves with varying frequency bandwidths, using tubing systems ranging from 20 cm to 300 cm in length including multiple tubing systems connecting three or more tubes. The results showed that the Bergh and Tijdeman models, with constant and variable polytropic parameters respectively, had superior correction performance for various tube lengths, while the Whitmore & Leondes model showed discrepancies. The Bergh & Tijdeman model, with a polytropic parameter of 1.4, is recommended due to its convenience and accuracy. Furthermore, including the inner volume of the pressure transducer in the theoretical model was found to be crucial for accurate correction, as not doing so caused significant errors. The Bergh & Tijdeman model was also found to efficiently correct tube length effects in multiple tubing systems, eliminating the need for time-consuming and laborious experiments.
        4,200원
        6.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study the characteristics of wind pressure that are depending on the open type of retractable dome roof were analyzed according to the wind pressure coefficient and wind pressure spectrum. The analysis results showed that the open type and shape of the roof both had a significant impact on the wind pressure changing. In case of the edge to center open type, the wind pressure has not changed much because of the complex turbulence of flow and open area. On the other hand, in case of the center to edge open type, it has confirmed that wind pressure increases due to the separation of flow in windward and open area.
        4,000원
        7.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The fluctuating wind pressure of the low rise ratio(f/D=0.1) for the elliptical dome roof was analyzed to compare it with the previous studies of circular dome roofs. Wind tunnel test were conducted on a total of 10 wind directions from 0° to 90° while changing wall height-span ratios(H/D=0.1-0.5). For this, meanCP, rmsCP and wind pressure spectrum were analyzed. The analysis result leads to find differences in the shape of the spectra in the spanwise direction and leeward of the elliptical dome according to the wind direction variations of the elliptical dome roof.
        4,000원
        8.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 일본의 건축구조기준(AIJ 2015)에서는 CFD 해석을 통한 풍하중 산정을 허용한 바 있다. 이는 컴퓨터의 연산 능력 향상 및 CFD 해석 이론의 발전으로 인해 해석의 결과가 풍동실험의 결과와 유사한 수준에 도달하였음을 뜻한다. 본 연구에서는 먼저 CFD 해석의 이론적 배경을 살펴보고, 일본의 건축구조기준 및 유럽의 과학기술연구 프로그램인 COST에서 권장한 CFD 해석 절차를 토대 로 해석을 진행하였다. 해석 결과의 신뢰성을 검증하기 위해 Tokyo Polytechnic University에서 제공하는 풍동실험 데이터를 사용하였 고, 해석과 실험의 유사성을 평가하기 위하여 형상비가 3, 4, 5일 때의 풍방향하중을 비교하였다.
        4,000원
        9.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wind tunnel tests were conducted to analyze the wind fluctuating pressures on a circular closed and open dome roof with a low span rise. Two dome models with various geometric parameters (height/span ratios and open ratios) were used for fixed span rise ratio dome and wind pressure spectrum were analyzed. The applicability was examined in comparison with the spectral model proposed in the previous studies. The analysis results show that the wind pressure spectrum of open dome roof tends to increase power in the high frequency range and the second peak is found in the area different from the closed dome roof. In addition, according to the comparison analysis with the previous proposed spectral model, it was found that it is not applicable to the closed and open dome roofs with low rise ratio due to the different peak frequencies.
        4,000원
        10.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the mean and fluctuating pressure coefficients derived from the results of wind tunnel tests on closed and open dome roofs were analyzed. The distribution characteristics of the fluctuating pressure according to the opening ratio and the height change were discussed. The analysis results showed that when the roof is open, the overall wind pressure decreases due to the open space, but more fluctuation occurred than the closed dome roof.
        4,000원
        11.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the wind pressure characteristics of elliptical plan retractable dome roof. Wind tunnel experiments were performed on spherical dome roofs with varying wall height-span ratios (0.1~0.5) and opening ratios (0%, 10%, 30% and 50%), similar to previous studies of cirular dome roofs. In previous study, wind pressure coefficients for open dome roofs have been proposed since there are no wind load criteria for open roofs. However, in the case of Eeliptical plan retractable dome roof, the wind pressure coefficient may be largely different due to the presence of the longitudinal direction and transverse direction. The analysis results leads to the exceeding of maximum and minimum wind pressure coefficients KBC2016 code.
        4,200원
        12.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        필로티는 현대건축에서 주차공간의 활용, 보행자의 통로 등 여러 가지 이점을 가지고 있기 때문에 아파트와 오피스텔과 같은 고층건축물에 많이 사용되고 있다. 이러한 고층건축물의 필로티 형태 특성상 강풍이 불 때 바람이 집중되기 때문에 필로티 천장과 벽 면에 위치하고 있는 외장재 및 주골조가 파손되기 쉽다. 그리고 이러한 외장재 및 주골조의 탈락으로 인해 2차 피해가 발생할 우려가 있다. 하지만 건축구조기준(KBC-2016)에서는 고층건축물에 대한 천장 및 벽면의 풍압계수만을 제시할 뿐 필로티에 대한 기준이 명시 되어 있지 않다. 본 논문은 고층건축물에서 사용되는 필로티의 종류로서 관통형, 개방형 필로티를 선정하였고, 필로티의 폭과 깊이를 변수로 하여 풍동실험을 진행하였다. 그리고 변수에 따른 풍압계수의 특성을 파악하였고 비교 및 분석하였고 본 논문의 실험결과를 통 하여 필로티 설계 시 활용할 수 있는 주골조 및 외장재 설계용 풍압계수를 제시하였다.
        4,500원
        13.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the reliability of the analysis is evaluated by comparing the average wind pressure coefficient, RMS wind pressure coefficient and wind pressure spectrum with same condition of wind tunnel test which are calculated in the high-Reynolds number range of 1.2 ×1.06, 2.0.×106 each for the typical curved shape dome structure. And it is examined by the reliability of analysis through Improved delayed detached Eddy Simulation(IDDES), which is one of the hybrid RANS/LES techniques that can analyze the realistic calculation range of high Reynolds number. As a result of the study, it was found that IDDES can be predicted very similar to the wind tunnel test. The distribution pattern of the wind pressure coefficient and wind pressure spectrum showed a similar compared with wind tunnel test.
        4,000원
        14.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of the variable shading devices are installed outdoors, so they are greatly affected by structural safety due to external climate change, wind, rain, and snow. Especially, due to strong wind such as typhoons, safety problems may occur due to the dropout of the device. Therefore, it is necessary to secure the structural safety against the wind. Therefore, it is necessary to analyze the structural behavior of the windshield to evaluate the structural safety of the variable sunshade device. In this study, we analyze the wind pressure applied to the shading material according to the change of the length of the variable shading device, and apply it to the calculation of the wind load for the structural design of the variable shading device. The CFD (Computational Fluid Dynamic) analysis of the structure of the sample was used to analyze wind pressure magnitude and distribution. In order to estimate the wind pressure, the maximum wind loads of the static and negative pressures acting on the structure were analyzed from numerical simulation results.
        4,000원
        15.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 필로티는 공간의 활용도나 미관상의 이유로 많이 사용되고 있다. 필로티는 외벽보다는 안쪽에 위치하나 외기에 접하는 형태로 강한 바람이 불 때, 바람길이 형성되고 강한 압력을 받아 필로티의 천장 및 벽면 부분의 외장재가 탈락하는 피해가 발생한다. 현재 건축구조기준(KBC-2016)에서는 필로티 건축물에 대한 천장 및 벽면의 풍압계수가 제시되어있지 않아 필로티 부분의 주골조 및 외장재에 대한 구조설계에 어려움이 있다. 이에 본 논문에서는 저층구조물의 관통형 필로티에 대한 풍압실험을 진행하여 풍압계수를 산출하였다. 실험 모형의 변수는 필로티의 높이와 폭으로 두었으며 변수에 따라 풍압계수를 산정하고 풍압분포의 변화를 비교·분석하 였다. 따라서, 필로티의 여러 변수 중 가장 불리한 풍압계수를 제시하여 이를 주골조와 외장재 설계 시 기초자료로 제공하고자 한다.
        4,000원
        16.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The biggest impact on the cladding design of buildings is wind loads. Wind tunnel tests were conducted to examine the applicability of current wind load standards about membrane retractable roof spatial structure. A dome model with a circular shape that is retractable to the center of the dome was made (Opening ratio = 0, 10, 30, 50). In addition, height adjustable turntables were made and tested with five patterns with H/D = 0.1, 0.2, 0.3, 0.4 and 0.5. The maximum wind pressure coefficient and the minimum wind pressure coefficient for the cladding were analyzed and the experimental wind pressure coefficient were compared with the current wind load standards, KBC2016 and AIJ-RLB(2015). The experimental value and the reference value of the enclosed roof were very similar and showed possibility of application, but opened roof case was found that the reference value was underestimated.
        4,000원
        17.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5–15 story buildings in a city center. The minimum peak wind pressure coefficient was –3.0 at the bottom edges of the front and back of the rooftop signboards and –2.0 along the entire length of the sides . As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.
        4,000원
        18.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from –2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from – 1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.
        4,000원
        19.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Spatial Structure has suffered from a lot of damage due to the use of lightweight roofs. Among them, the damage caused by strong winds was the greatest, and the failure of the calculation of the wind load was the most frequent cause. It provides that wind tunnel test is used to calculate the wind load. However, it is often the case that the wind load is calculated based on the standard of wind load in the development design stage. Therefore based on this, the structure type and structural system and member design are often determined. Spatial structure is usually open at a certain area. The retractable roof structure should be operated with the open roof in some cases, so the wind load for the open shape should be considered, but it is not clear on the basis of the wind load standard. In this paper, the design wind pressure of a closed and retractable roof structure is calculated by KBC2016, AIJ2004, ASCE7-10, EN2005, and the applicability of wind pressure coefficient is compared with wind tunnel test.
        4,200원
        20.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Vortex-induced vibration and instability vibration of tall buildings are very important fluid-structure interaction phenomenon, and many fundamental questions concerning the influence of body movement on the unsteady aerodynamic force remain unanswered. For tall buildings, there are two experimental methods to investigate the characteristics of unsteady aerodynamic forces, one is forced vibration method and the other is free vibration method. In the present paper, a free vibration method was used to investigate the unsteady aerodynamic force on tall building whose aspect ratio is 9 under boundary layer simulating city area. Wind pressures on surfaces and tip displacements were measured simultaneously, and the characteristics of tip displacements and generalized forces were discussed. It was found that variation of across-wind displacements showed different trend between the case when wind speed increases and wind speed decreases, and the fluctuating generalize forces in across-wind direction of vibrating model are larger than that of static model near the resonant wind speed and approach to the static value. And for higher wind speed range, there were two peaks in across-wind power spectra of generalize forces of vibrating model, which means that two frequency components are predominant in unsteady aerodynamic forces.
        4,000원
        1 2 3