        81.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the continuous cap-type shear connector. Existing formulas for the elevation of shear connector capacity were investigated on the basis of test results. The shear capacities of continuous cap-type shear connectors distinctly declined as the diameters of side-hole in the shear connector increased. The rebars through side-hole for the transverse reinforcement improved the shear capacity of continuous cap-type connector by 20 to 30 percent. It was not feasible to obtain the appropriate capacity values of continuous cap-type shear connectors made of thin steel plate like those of in this study, using the existing formulas. The new formula for reflecting the shear strength of penetrative bars was proposed based on the shear equation of Eurocode 4. The slip capacities of continuous cap-type shear connectors were shown to exceed the limit value of 6mm for the sufficiently ductile behavior.
        4,000원
        82.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내 구조물들의 노후화가 진행됨에 따라 구조물 보강과 관련된 연구에 대한 관심이 높아지고 있다. FRP보강은 노후화가 진행되어 성능이 저하된 구조물을 보강하는데 사용되며 주로 유리섬유 및 탄소섬유를 사용한다. 그러나 이 두 가지의 섬유는 경제적으로나 환경적으로나 나쁜 점이 있다. 따라서 본 연구에서는 친환경적이고 내열성이 우수한 현무암 섬유를 구조 용 보강재로 제시하고자 하였다. 또한 본 연구에서는 현무암 섬유에 가장 적합한 수지를 찾기 위하여 에폭시, 폴리에스테르 및 비닐에스테르를 함침 하였다.그 결과, 에폭시 수지를 사용하였을 때 가장 높은 인장 강도 및 탄성계수를 보였으며 전단강도 및 전단탄성계수가 타 수지에 비하여 50%정도 높게 측정되었다. 현무암섬유와 탄소, 유리 섬유의 물성을 비교한 결과 인장강도는 CFRF의 약 60%정도이나 GFRP보다 30%정도 높게 나타내었다.
        4,000원
        83.
        2019.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To calculate proper seismic design load and seismic design category, the exact site class for construction site is required. At present, the average shear-wave velocity for multi-layer soil deposits is calculated by the sum of shear-wave velocities without considering of vertical relationship of the strata. In this study, the transfer function for the multi-layered soil deposits was reviewed on the basis of the wave propagation theory. Also, the transfer function was accurately verified by the finite element model and the eigenvalue analysis. Three methods for site period estimation were evaluated. The sum of shear-wave velocities underestimated the average shear-wave velocities of 526 strata with large deviations. The equation of Mexican code overestimated the average shear-wave velocities. The equation of Japanese code well estimated the average shear-wave velocities with small deviation.
        4,000원
        84.
        2019.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic performance of ordinary reinforced concrete shear wall systems commonly used in high-rise residential buildings is evaluated. Three types of shear walls exceeding 60m in height are designed by performance-based seismic design. Then, incremental dynamic analysis is performed collapse probability is assessed in accordance with the procedure of FEMA P695. As a result, story drift, plastic rotation, and compressive strain are observed to be major failure modes, but shear failure occur little. Collapse probability and collapse margin ratio of performance groups do not meet requirement of FEMA P695. It is observed that critical wall elements fail due to excessive compressive strain. Therefore, the compressive strain of concrete at the boundary area of the shear wall needs to be evaluated with more conservative acceptance criteria.
        4,500원
        87.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is 0.062 ㎡(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.
        4,000원
        91.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research focuses on developing the Smart material with Grease adopted as a base oil to overcome a particle deposition caused by the MR fluid consisting of a silicon, which maximizing the characteristics and advantage of the MR fluid. By adopting the SMG fluid to a shear damper, this paper aimed to evaluate the control performance of it according to the variation of intensity of electric current(0 A, 0.5 A, 1.0 A, 1.5 A, 2.0 A, 2.5 A) and frequency(0.5 Hz, 1 Hz, 2 Hz). Subsequently, the usability of the SMG damper was analyzed by comparing the dynamic model of it to that of the other types of dampers(Power(Involution) Model, Bingham Model). As a result, DR, the performance indicator of semi-active damper, shows approximately 5 in a condition of 2 Hz. Also while confirming the excellent performance like the Power and the Bingham model, it raises the possibility to exploit it as the semi-active damper.
        4,000원
        92.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is 90° and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.
        4,000원
        93.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        합성보에 휨모멘트가 작용하면, 콘크리트 슬래브의 아랫면과 강재보의 윗면은 각각 인장력과 압축력에 의하여 팽창과 수축을 한다. 필연적으로 두 부재의 사이에서는 미끄러지려고 하는 수평전단력이 작용하게 되며, 이에 저항할 수 있는 전단 연결재의 역할이 매우 중요하다. 이 연구에서는 화약의 폭발력을 사용하여 강재보의 플랜지에 전단연결재를 고정하는 방법을 개발하였다. 개발 고정방법의 구조성능을 검증하기 위하여 보-기둥 접합부 실험과 유한요소해석을 수행하였다. 실험 및 해석결과를 기반으로 판단했을 때, 개발된 접합방식을 통하여 충분한 연성 및 강도를 확보할 수 있을 것으로 판단된다.
        4,000원
        94.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 국내에서는 고층 벽식 아파트 건설 시, 하부 주차공간과 공용공간 확보를 위하여 RC 전이슬래브 시스템을 사용하는 경우가 증가하고 있다. 하지만 두께가 얇은 RC 무량판 슬래브를 위해 개발된 설계방법 및 구조성능평가 방법을 두께가 매우 두꺼운 전이슬래브 구조설계에 그대로 사용하고 있다는 문제점이 있다. 따라서 합리적인 전이슬래브의 구조설계를 위해서는 RC 전이슬래브 시스템의 2면 전단거동 양상에 대한 명확한 분석이 필요하다. 이에 따라 본 연구에서는 전이슬래브의 두께, 콘크리트 강도, 전단경간비, 철근비 등 다양한 설계변수에 따라 비선형 FEM을 이용하여 전이슬래브의 2면 전단거동을 분석 하였다. 또한 비선형 FEM 해석결과와 기존의 2면 전단강도 평가식으로 예측한 전단강도를 비교분석하여 기존 평가식의 전이슬래브 2면 전단강도 평가 유효성을 검토하였다.
        4,800원
        95.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        초고층 건물의 횡변위 제어를 위하여 사용되는 아웃리거를 기존의 철골 트러스 대신에 철근콘크리트 벽체로 대체할 수 있다. 철근콘크리트 아웃리거 벽체를 외부 기둥에 연결할 경우에는 축력뿐만 아니라 전단력과 모멘트가 외부 기둥에 유발될 수 있다. 본 연구에서는 아웃리거 벽체 외단부의 회전으로 인한 외부 기둥의 전단력을 수식으로 유도하고 그 값을 유한요소해석 결과와 비교하였다. 유한요소해석에서는 층별 연결보의 효과와 전단벽과 아웃리거를 보와 평면응력요소로 모델링한 효과를 분석하였다. 층별 연결보의 효과는 거의 없었으며 평면응력요소는 보요소보다 더 큰 강성을 가진 것으로 해석되었다. 아웃리거 벽체의 외단부 회전으로 인한 외부기둥의 층간 회전각과 전단력은 허용값에 비하여 상당히 작은 값이 발생하였다. 따라서 초고층 건물에 철근콘크리트로 된 아웃리거 벽체를 적용할 경우에도 외부 기둥에 유발되는 전단력과 모멘트에 대하여 별도의 검토를 할 필요는 없을 것으로 판단된다.
        4,000원
        96.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 지진에 저항하는 부재인 비보강 조적벽체로 구성된 건물의 내진성능평가에 활용되는 비선형 정적해석을 위한 비보강 조적벽체의 해석모델을 수립하고자 하였다. 본 연구의 해석모델은 비보강 조적벽체의 휨거동을 모사하기 위한 파이버 요소와 비보강 조적벽체의 전단에 대한 응답을 예측하기 위한 전단스프링 요소로 구성된다. 본 논문은 먼저 제안하고 있는 모델의 형상에 대해서 설명하고, 기존에 행해진 조적조 프리즘의 실험결과로부터 얻은 응력-변형률 곡선을 근거로 파이버와 전단스프링 요소의 물성치에 대한 결정 방법을 설명한다. 제시하고 있는 모델은 비선형 정적 해석결과와 다른 연구자들에 의해 수행된 실험결과를 비교하여 타당성을 검증한다. 해당 모델은 최대강도, 초기강성, 그리고 이들로부터 얻어지는 비보강 조적벽체의 하중-변위 곡선을 적절하게 모사하고 있다. 또한, 해석모델이 비보강 조적벽체의 파괴모드를 예측할 수 있는 것으로 나타난다.
        4,000원
        97.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Tensile load tests were conducted on High-Shear Ring Anchors (HRAs) after shear load had been applied to the HRAs, which had been developed to reduce the number of the anchors. Test variables include the embedment length of the rod and the width of the specimens and a total of 12 specimens were tested. Test results show that the HRAs pulled out due to bond failure or steel failure occurred in case that the HRAs were installed to the members with 300mm or greater width and the embedment length of 160mm (the actual embedment of rod is 140mm) or deeper. Except 4 HRAs showing steel failure of rod, the minimum and average of test-to-prediction by ACI 318-14 ratios are 1.18 and 1.79, respectively. The tensile strength of HRAs, after shear load was applied to the HRAs, can be safely evaluated by the minimum among the concrete breakout strength and bond strength with the actual embedment length of the rod.
        4,000원
        99.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn’t have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.
        4,000원
        100.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The degree of interaction is a very important factor determining stiffness, strength and deflection performance in the composite beam. Because this synthesis is made through the shear connector, the structural performance of the shear connector is very important. In this study, the connection method was developed using the driving pin to solve the problem of conventional welding connection method. To verify the structural performance of the developed connection method, the push-out test was performed and analyzed against numerical analysis results. Based on the results of the analysis, it is deemed that the structural performance can be obtained by joining the shear connection in proposed method.
        4,000원