검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 41

        1.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the effect on the inelastic behavior and structural performance of concrete and filled steel pipe through a numerical method for reliable judgment under various load conditions of the CJS composite structural system. Variable values optimized for the CJS synthetic structural system and the effects of multiple variables used for finite element analysis to present analytical modeling were compared and analyzed with experimental results. The Winfrith concrete model was used as a concrete material model that describes the confinement effect well, and the concrete structure was modeled with solid elements. Through geometric analysis of shell and solid elements, rectangular steel pipe columns and steel elements were modeled as shell elements. In addition, the slip behavior of the joint between the concrete column and the rectangular steel pipe was described using the Surface-to-Surface function. After finite element analysis modeling, simulation was performed for cyclic loading after assuming that the lower part of the foundation was a pin in the same way as in the experiment. The analysis model was verified by comparing the calculated analysis results with the experimental results, focusing on initial stiffness, maximum strength, and energy dissipation capability.
        4,300원
        2.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        천연골재의 부족으로 골재 수급이 날이 갈수록 심각해지면서 재활용 가능한 재료에 대한 사회적 관심이 높아지고 있다. 하지만 국내에서는 선진외국에 비해 순환골재에 대한 연구데이터와 그를 사용한 현장 적용실정이 매우 부족한 실정이다. 본 논문에서는 현장에서 사용하는 레미콘 사의 가이드 배합에 순환골재를 전량 치환하는 배합비를 추출하여 압축강도를 평가하였 고 추출된 배합비의 순환골재 콘크리트를 원형강관 내부에 충전하여 순환골재콘크리트충전 합성기둥이 국내ㆍ국외 설계식을 반 영한 내력과 비교하여 구조부재로써 사용이 적합하다고 사료되는 결과를 얻었다. 또한, 강관의 콘크리트 구속효과로 인해 강관 내부의 콘크리트 강도가 미세하게 증가함을 확인하였다.
        4,000원
        4.
        2019.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트로 채워진 강관기둥은 많은 구조 시스템에서 기둥으로 널리 사용되며 강재가 항복하고 구속효과가 감소하여 국부 좌굴이 발생한다. 이러한 단점을 극복하기 위해 FRP를 보강하여 국부 좌굴을 지연시키는 방법을 제안한다. 이 논문은 반복 압축하에서 FRP로 보강된 CFT의 압축성능에 관한 것이다. 두 가지 유형의 FRP (Aramid FRP, SRF Polyester Belt)가 다양한 보강두께와 겹수로 CFT 외부에서 보강하여 비교 분석된다. 또한, CFRP에서 제안 및 사용된 공식에 기초하여 시험 기관의 실험 값을 평가하고 그것이 사용될 수 있는지를 결정할 것이다.
        4,000원
        5.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ACT Column은 기존 CFT 기둥보다 얇은 강판으로도 동일한 구조적 성능을 발휘할 수 있으며, 콘크리트의 구속효과와 강관의 항복 후 좌굴응력의 향상을 기대할 수 있다. ACT Column은 보-기둥 접합부에 외다이아프램을 사용한 접합상세가 적용된다. 그러나 ACT Column 외부에 콘크리트가 피복되는 SRC 타입에서는 외다이아프램을 사용한 접합부의 적용이 난해하다. 그래서 ACT Column의 외부에 수직 스티프너와 수평 스티프너를 사용한 접합상세를 제안하였다. 본 논문에서는 제안상세를 대상으로 단순인장실험을 통해 성능검증을 수행하였다. 실험체는 현장에 사용량이 많은 크기의 ACT Column 으로 2개의 실험체를 제작하였다. 보 플랜지와 보 플랜지의 양측부에 부착된 윙플레이트를 통해 보 플랜지의 단면 내력이 링다이아프램으로 전달되는 명확한 응력전달매커니즘을 나타내었으며, 보 플랜지 전단면이 소성화되어 파괴되었다. 윙플레이트의 크기가 클수록 하중전달량이 증가하였으며, 제안한 접합상세의 강도평가식을 제시하였다.
        4,200원
        6.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recycled aggregate is a solution to reduce construction waste and to be environmentally friendly, but concrete using it has various disadvantages in terms of structure. Therefore, the interaction effect of the two materials can be expected by filling the cyclic aggregate concrete in the CFT column. Eighteen specimens were constructed to confirm the compressive behavior of RCFT (Recylced Concrete Filled Tube) columns, which can be applied to real buildings by making high strength concrete with recycled aggregate. Variable is the shape and thickness of steel pipe, concrete strength and mixing ratio, and coarse aggregate and fine aggregate are all used as recycled aggregate. A total of three recycled aggregate concrete preformulations were used to find the optimal mixing ratio and the compressive behavior was analyzed through the load - displacement curves of RCFT columns.
        4,000원
        7.
        2018.04 구독 인증기관 무료, 개인회원 유료
        Concrete using recycled aggregate instead of natural aggregate reduces environmental waste and is a future oriented material. However, use of the structure is limited to negative recognition of recycled aggregate quality. In this study, 50 MPa concrete was developed using recycled aggregate. In order to verify the possibility of using as a column member, we aimed to confirm the compressive behavior of RCFT (Recycled Concrete Filled Tube) columns filled with concrete using recycled aggregate. Circular type steel pipe was used, and concrete strength (30, 40, 50MPa) and mixing ratio were the experimental parameters. Through 72 specimen compression tests, 50MPa strength of recycled aggregate concrete was confirmed and stable behavior of 9 RCFT columns was confirmed.
        3,000원
        8.
        2018.04 구독 인증기관·개인회원 무료
        Unlike column-to-beam connections in reinforced concrete frames, column-to-beam connections are generally of the same type. Vertical load (D.L + L.L) and horizontal load (wind load, seismic load) are not the same in the upper and lower flange stress history. In the case of beams bonded to synthetic CFT columns, the tensile force is transmitted through the steel pipe column, and the compressive force is transmitted to the filled concrete, so the seismic performance is excellent even if the column has a relatively thin cross section. Also, in case of beam the composite CFT column, tensile force is taken by the steel pipe column, and the compressive force is caught by the inner concrete, and the shape of the column joint can be changed. In this study, the stress distribution of buildings is investigated according to the size and characteristics of the building, and the load history of the upper and lower flanges according to the building type is checked to show the structural possibility of the Asymmetric Diaphragms joint.
        9.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 부분 보강된 CFT 기둥의 폭발저항성능을 일반 CFT 기둥과 비교하여 강판 보강의 효과를 확인하였다. 폭발하중을 받는 CFT 기둥의 구조해석에는 폭발과 충돌 해석을 위한 특수한 하이드로코드인 Autodyn을 사용하여 수치해석을 수행하였다. 콘크리트와 이를 둘러싸고 있는 강판 사이의 상호작용을 모델링하는 여러 방법이 있다. 본 연구에서는 기둥의 실제 파괴를 표현하기 위해 마찰 옵션 및 조인 옵션으로 모델링하였다. 해석에 따르면, 부분 보강된 CFT 기둥은 일반 CFT 기둥에 비해 더 나은 폭발저항효과를 나타내었다. 보강 CFT기둥의 폭발저항성능은 콘크리트를 둘러싸고 있는 부분 보강된 강판의 높이가 높을수록 향상되었으며 CFT 기둥의 단면 크기 이상으로 보강할 것을 추천한다.
        4,000원
        10.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 CFT 구조의 강관과 내부 충전 콘크리트 간 복합거동을 유한요소해석 시 적절하게 반영하기 위해 강관과 콘크리트 간 부착 슬립관계 묘사를 위한 알고리즘을 제시하였다. 내부 충전 콘크리트에 축방향 하중 발생 시, 강관과 콘크리트 간 마찰로 인해 강관으로 하중이 전달되며, 이에 따른 강관 슬립량과 힘의 평형관계를 통해 등가강성을 통해 부착관계를 파악할 수 있다. 실제 원형 CFT 부재의 부착응력 실험을 통해 측정된 수직 및 수평 방향 응력 분포 결과와 제안된 해석 기법을 통해 산정된 응력 분포의 비교를 통해 제안된 해석 기법의 타당성을 검증하였다. 또한 비선형 유한요소해석 시 강관과 콘크리트의 부착 거동 묘사에 따라 CFT 기둥의 거동 특성에 영향을 미치게 되므로 축방향 하중이 작용하는 CFT 부재 실험결과와 제안된 부착-슬립 모델을 반영한 유한요소해석 결과의 하중-변위 곡선 관계 비교를 통해 제안된 기법의 적합성을 검증하였다.
        4,000원
        11.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Generally, the Load of upper structures is transferred to concrete foundations through columns supporting them. So, the anchor connection system is usually adopted in order to connect the columns and the concrete foundations. To apply this system, the column-foundation connections need to be designed with enough stiffness. This study was experimentally conducted to effectively improve the structural detail of circular CFT column-foundation connections, to which axial and lateral load simultaneously apply. For this study, the test specimen with a general anchor and an anchor frame, and the specimens with the high-tension bolt and inner reinforcement were fabricated. In addition, double base plates were adopted to have the enough stiffness of connections. The behavioral characteristics and the failure mode were investigated and compared, and the improvement of structural detail of circular CFT column-foundation connections was suggested.
        3,000원
        12.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, circular sectional concrete-filled tube(CFT) column-to-foundation connections were numerically investigated in order to improve their structural details. A inner reinforced specimen with high-tension bolts and inner deformed bars was adopted from a previous experimental study to make the numerical model. The validity of the numerical method was verified through comparing the experimental results with the analysis’s ones. In order to optimize design variables about the inner reinforced model, a number of numerical analyses were conducted for various variables. Finally, this study suggested the optimum variables about the reinforced circular sectional CFT column-to-foundation connections.
        4,000원
        13.
        2013.04 구독 인증기관 무료, 개인회원 유료
        This study investigates the stress-strain relations of internally confined hollow concrete filled tube pier reinforced with GFRP tube by uniaxial compression test. The confined concrete subjected multi-axial stresses have been known as the strength of concrete increases significantly. Many researchers have studied in confining effects of CFT which have only outer GFRP tube. In this study, specimens reinforced with outer and inner GFRP tube were tested by uniaxial compression test. To investigate the influence of concrete strength increase by confining conditions in GFRP tube, 13 specimens with different thickness of tube, hollowness ratio and nominal concrete strength were tested and compared with Steel tube.
        3,000원
        14.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.
        4,000원
        15.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The construction of a moment connection for a rectangular hollow section (RHS) column and a H-shaped beam is difficult because the RHS is a closed section. When a inner diaphragm is used for such a connection, in general, it is installed after cutting the HSS columns, which results in increased construction work. This paper suggests a new fabrication method to overcome such problems: An inner diaphragm is welded to inside a C-shaped section first, and then a column is fabricated by welding two C-shaped sections. This fabrication method is superior to a classic method in terms of constructibility. An experimental and a numerical study using Ansys 9.0 were performed in order to compare the strength of connections with respect to the presence of concrete, the corner shape of diaphragm, and the axis of loading. The experimental results including initial stiffness and ultimate loads are reported and the analytical results including load transfer mechanism, degree of stress concentration, and strain distribution are also reported.
        4,200원
        16.
        2012.04 구독 인증기관·개인회원 무료
        The Composite structures such as CFT(Concrete Filled Steel Tube) have many advantages compared to the H shape columns, concrete columns. But, CFT columns were reinforced difficult which was members with closed section. When beams size were different around the columns in buildings of various form, the construction was complex that diaphragm was overlapped or inclined. In this study, structural performance comparison of horizontal diaphragm and vertical plates was conducted.
        17.
        2011.04 구독 인증기관·개인회원 무료
        The Axial compression tests were conducted on FRP strengthened circular CFT short clumns with the test parameters of D/t ratio and the number of FRP sheet ply. The ultimate strength design formula were proposed by applying ACI 440 code for FRP strengthened circular CFT columns.
        18.
        2011.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to deliberate on design application for a structure of beam with partially restrained composite connection to CFT column. It was intended to apply an economic and stable component by adjusting stiffness ratio of column connection through partially restrained composite connection. As a result of the review of stability of the structure, it was confirmed that in case of a low-rise building as a moment frame, it could be resisted without brace, as stiffness was increased when taking advantage of partial restrained composite connection by composite action.
        3,000원
        19.
        2011.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 CFRP쉬트로 보강된 원형 CFT기둥의 압축거동을 관찰하고 설계식을 제안하였다. 원형 CFT기둥의 CFRP쉬트의 보강효과를 관찰하기 위해 10개의 실험체를 제작하여 중심축하중 실험을 수행하였다. 실험변수로는 CFRP쉬트 보강겹수와 직경-두께비(D/t)이다. 실험결과 원형CFT기둥에 CFRP쉬트 보강을 통해 압축내력을 증가시킨 것으로 나타났다. 끝으로 ACI 440code를 응용하여 CFRP 보강된 원형 CFT기둥의 압축내력을 예측하기 위한 설계식 을 제안한다. 제안식을 분석한 결과 실험결과와 비교적 일치한 것으로 나타났다.
        4,000원
        1 2 3