검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 337

        101.
        2016.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Graphite was diffusion-bonded by hot-pressing to W-25Re alloy using a Ti interlayer. For the joining, a uniaxial pressure of 25 MPa was applied at 1600 oC for 2 hrs in an argon atmosphere with a heating rate of 10 oC min−1. The interfacial microstructure and elemental distribution of the W-25Re/Ti/Graphite joints were analyzed by scanning electron microscopy (SEM). Hot-pressed joints appeared to form a stable interlayer without any micro-cracking, pores, or defects. To investigate the high-temperature stability of the W-25Re/Ti/Graphite joint, an oxy-acetylene torch test was conducted for 30 seconds with oxygen and acetylene at a 1.3:1 ratio. Cross-sectional analysis of the joint was performed to compare the thickness of the oxide layer and its chemical composition. The thickness of W-25Re changed from 250 to 20 μm. In the elemental analysis, a high fraction of rhenium was detected at the surface oxidation layer of W-25Re, while the W-25Re matrix was found to maintain the initial weight ratio. Tungsten was first reacted with oxygen at a torch temperature over 2500 oC to form a tungsten oxide layer on the surface of W-25Re. Then, the remaining rhenium was subsequently reacted with oxygen to form rhenium oxide. The interfacial microstructure of the Ti-containing interlayer was stable after the torch test at a temperature over 2500 oC.
        4,000원
        102.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We investigate the microstructural and magnetic property changes of DyH2, Cu + DyH2, and Al + DyH2 diffusion-treated NdFeB sintered magnets with the post annealing (PA) temperature. The coercivity of all the diffusiontreated magnets increases with increasing heat treatment temperature except at 910oC, where it decreases slightly. Moreover, at 880oC, the coercivity increases by 3.8 kOe in Cu and 4.7 kOe in Al-mixed DyH2-coated magnets, whereas this increase is relatively low (3.0 kOe) in the magnet coated with only DyH2. Both Cu and Al have an almost similar effect on the coercivity improvement, particularly over the heat treatment temperature range of 790-880oC. The diffusivity and diffusion depth of Dy increases in those magnets that are treated with Cu or Al-mixed DyH2, mainly because of the comparatively easy diffusion path provided by Cu and Al owing to their solubility in the Nd-rich grain boundary phase. The formation of a highly anisotropic (Nd, Dy)2Fe14B phase layer, which acts as the shell in the core-shell-type structure so as to prevent the reverse domain movement, is the cause of enhanced coercivity of diffusion-treated Nd-Fe-B magnets.
        4,000원
        103.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 고자장 MRI가 보급화 되면서 자장의 불균일(field inhomogeneity)에 대한 문제점이 제기되고 있는 가운데, Echo Planner Image(EPI) 기법을 이용한 영상에서 균일화 과정을 통해 영상을 개선할 수 있는 연구의 필요성이 대두되고 있다. 특히, EPI기법을 이용한 뇌 확산강조 영상 검사시, prefrontal lobe과 temporal lobe의 경우 공기와 조직 간의 경계에 있는 부위로, 자화율 차이에 따라 왜곡된 영상이 획득된다. 이러한 문제점을 해결하고 보완하기 위하여 본 연구에서는 정상인을 대상으로 T2WI와 DWI를 이용하여 파라핀 적용 전·후에 따른 자장의 불균일 보정과 영상 개선 효과를 평가하고자 하였다. 대상 및 방법 : 본 연구는 2015년 9월부터 10월까지 참여한 정상인 10명(평균 29.6±3.84세)을 대상으로 하였다. 3.0T MR system(Discovery 750 scanner, GE Medical System, USA)와 16-channel head 코일을 이용하여 T2 강조영상(T2WI)과 확산강조영상(DWI)을 먼저 획득하였다. T2WI는 DWI와 비교하기 위한 기준 영상으로 사용되었다. 그런 다음 공기와 조직 간의 경계에 위치하는 전두엽과 측두엽에서 자화율 차이에 따른 자장의 불균일을 보정하기 위하여 인체 조직밀도와 유사한 파라핀을 head 코일과 검사자 머리에 부착하여 DWI를 얻었다. T2WI는 TR/TE= 6594/96msec를 사용하여 축상면 방향으로 영상을 획득하였다. 이때 사용된 FOV는 230×230, matrix 320×320, 2 NEX, ST 4mm로 하였고, 총 영상획득 시간은 165초였다. DWI의 영상변수로는 b-value= 1000, 0s/mm², TR/TE= 8000/62msec, FOV= 230×230, matrix= 160×160, 4 NEX, ST= 4mm로 하였으며, 이때 총 영상획득 시간은 101초였다. Image J를 이용하여 T2 강조영상(T2WI)과 확산강조영상(DWI)의 면적을 측정하였으며, prefrontal lobe 주변의 background 표준편차와 백질의 신호강도를 비교하여 SNR을 분석하였다. 결 과 : 기준 영상인 T2WI, 파라핀 적용 전 DWI(b-value 1000), 그리고 파라핀 적용 후 DWI(b-value 1000)의 평균 면적은 각각 39,843.20±1608, 35,346.70±1978 그리고 37,862.60±1852 이었다. 파라핀 적용 전 DWI(b-value 0)와 파라핀 적용 후 DWI(b-value 0)의 평균 면적은 각각 35,541.60±1981, 38,061.60±1853 이었다. T2WI와 비교하여 개인별 면적의 오차는 적용 전보다 모두 감소하였으며, 파라핀 적용 전·후 DWI SNR 평균은 b-value 1000 45.69±21.96에서 80.42±39.31 bvalue 0 89.85±45.72에서 149.90±73.41 이었다. 파라핀 적용 후 DWI의 SNR이 파라핀 적용 전에 비해 약 1.6배에서 최대 1.8배 정도 증가하였다. 결 론 : 파라핀을 적용한 확산강조영상(DWI)은 적용 전에 비해 SNR이 증가하였으며 신호소실과 왜곡이 감소되었다. 이로 인해 T2WI 비교하여 면적의 오차가 상당히 감소함을 확인하였다. 자체 제작한 보정 물질(파라핀)은 불균일한 자장 요소를 일정 이상 보완할 수 있으며, 저비용과 더불어 높은 기술력이 필요하지 않으므로 고 효율적으로 영상 신호소실과 왜곡을 개선하여 영상의 질을 향상 시킬 수 있으리라 사료된다.
        4,000원
        105.
        2016.10 구독 인증기관·개인회원 무료
        Time-temperature indicators or integrators (TTIs) indicate food quality changes based on time-temperature history. Whilst many types of TTIs have been developed and commercialized, educated consumers often refuse to purchase food products with attached TTI labels showing even a slight color change. In this study, a novel on-off diffusion-based TTI coupled with polydiacetylene/silica nanocomposites has been proposed. The prototype TTI tag has a multilayer structure comprised of a self-adhesive base layer, a middle microporous sheet, and an upper opaque white layer coupled with a square reservoir of Tween 20 attached to an activation stripe. At the end of the diffusion path, polydiacetylene/silica nanocomposites were injected into a loading site as a fine blue stripe. After activation, Tween 20 diffused and reached the loading site, where it rapidly changed from blue-to-red via solvatochromism. This alternative and innovative TTI continuously showed a blue color until reaching the end point, at which stage a red color rapidly appeared, indicating product rejection. Thus, this novel TTI it is of great benefit to the brand owner. The developed prototype was characterized and evaluated for its ability to monitor microbial quality based on published, isothermal, microbial growth data of modified-atmosphere packaged minced beef, Mediterranean fish, and ground pork. The diffusion of Tween 20 in the TTI system was measured under various isothermal conditions and a kinetic model, based on the association between diffusion and time-temperature, was investigated. The Gaussian-estimated activation energy value was 51.082kJ mol-1. Tween 20 diffusion of 6.10, 5.15 and 6.15mm along the TTI systems were considered to be end points and the 95% confidence interval between the times taken for TTI to display OFF and for the foods to reach their deterioration thresholds were 23.30-23.70, 23.00-23.50 and 23.44-24.05h for total aerobic bacteria, Shewanella putrefaciens, and Pseudomonas spp. respectively. The TTI performance test for reproducibility and accuracy revealed a normal frequency distribution with 35004.90, 1200.254.82 and 549.811.09min at 0, 11 and 25C, respectively in accordance with the investigation of diffusion in the TTI.
        106.
        2016.10 구독 인증기관·개인회원 무료
        Differences in sugar and salt diffusion rates of cabbage depending on size and part were examined. Whole, 3x3 and 5×5 cube sliced cabbage examined indifferent pickling condition (salt 2, 4, 6, 8% and sugar 5, 10, 15, 20% brix). After 12hr storage, salt absorption depending on part was determined to be higher in leaf, followed by stem in all salt solution. Sugar distribution was also determined to be higher in leaf, followed by stem, showing same trend with salt diffusion. Salt diffusion was found to be highest in 3×3 sliced cabbage. Where as 5×5 sliced cabbage and then whole cabbage showed lower diffusion rate in all brix sugar solution. Size dependent sugar diffusion showed same tendency with size dependent salt diffusion. Also, increase in salt and sugar concentration led to increase in salt and sugar permeation rate.
        108.
        2016.07 구독 인증기관·개인회원 무료
        The rapid development of the internet has enlarged the scale and scope of marketing communication and supported a base for electronic word–of-mouth (e-WOM). According to Bickart and Schindler (2001), e-WOM usually includes personal experiences and opinions transmitted via the written words in virtual social networks. Studies on e-WOM in virtual communities suggest that e-WOM strongly influences attitudes and behaviors of consumers and thus importance of e-WOM is growing in marketing communication and advertising. Accordingly, a lot of researchers have investigated to identify factors influencing e-WOM activity. Noticeably, characteristics of e-WOM receivers (e.g. Awad & Ragowsky, 2008; Godes & Mayzlin, 2004) and usage experiences of e-WOM in Social Network Service (SNS) (e.g. Flanagin & Metzer, 2000; Johnson, Kaye, Bicard, & Wong, 2008) have been frequently examined. These factors are expected to contribute to a research model in the current research. Based on previous studies, this research investigates factors which have a positive impact on diffusion of e-WOM information. Specifically, three characteristics of e-WOM receivers are suggested as antecedents: perception of instrumentality of e-WOM, perception of usefulness of e-WOM, and perception of trust in e-WOM. In addition, a moderating variable is proposed: usage experiences of e-WOM. A Structured questionnaire is designed to measure the proposed factors and diffusion of e-WOM information with a five-point Likert scale. An online survey is used to collect responses of consumers who have experienced e-WOM information on a certain goods or services in SNS within the last three months. 358 usable responses are used for statistical analyses to examine the proposed research model. This study will contribute to the e-WOM research field where there is little published work to identify characteristics of e-WOM receivers and their effects on diffusion of e-WOM information, suggest the model of information processing of e-WOM, and consider both roles of e-WOM receivers and senders of consumers. It may also provide managerial implications to devise a better marketing communication strategy by harnessing e-WOM and encouraging influential individuals as considerable promoters to shape the scope of advertising and e-WOM processes.
        109.
        2016.07 구독 인증기관·개인회원 무료
        The paper addresses the phenomenon of the opportunism that arises from a parent (principal) toward an IJV (agent) and its antecedents. This study integrates Agency Theory and Resource Dependence Theory (RDT) to discover its determinants from the perspectives of principal opportunism. Using Structural Equation Modelling (SEM) techniques and fuzzy-set qualitative comparative analysis (fsQCA) based on a sample of 185 Chinese-foreign IJVs in China, which are useful to reals the overall story of the principal opportunism. This study finds an IJV depends on parents’ support in both knowledge- and property-based resources has more chances to subject to principal opportunism. The result also indicates that psychic distance has a negative impact on principal opportunism. fsQCA, however, provides further solutions that the specific combinations of these predictors or their negation predicts principle opportunism.
        110.
        2016.05 구독 인증기관·개인회원 무료
        최근 물 부족 문제가 대두되면서 막기반 해수담수화 기술이 해결책으로 주목 받고 있다. 공정 기술에서 에너지 소모 저감이 핵심으로 고려되고 있는 가운데, 고분자 막기반 해수담수화 공정의 에너지 소모량이 더 이상 줄어들지 않는 정체 현상을 보이면서, 성능 향상 및 에너지 소모량을 줄이기 위한 막개발이 핵심 으로 고려되고 있다. 최근 신소재를 이용한 막개발이 활발한 가운데, 원자수준 의 두께 및 물리/화학적 안정성, 높은 강도 등을 장점으로 하는 그래핀 (Graphene) 막 개발 연구가 진행되고 있다. 본 연구에서는 물질이동 기작을 밝히기 위해 물 및 유기 용매가 그래핀 막에서 가지는 투과 성능을 온도 및 습도 조건을 달리하는 조건에서 측정하고, 이를 바탕으로 그래핀 막의 투과 성능 및 기작에 대해 평가하고자 하였다.
        111.
        2016.05 구독 인증기관·개인회원 무료
        기체분리막의 기체의 투과거동은 대부분 실험적으로 계획되고 실험이나 이론 만으로 검증을 하는 수준에 머무르고 있다가, 최근에 들어서 분자동력학적인 모 사방법(Molecular Dyanmic Simulation)을 이용하여 고분자의 거동, 기체분자의 거동을 컴퓨터를 이용하여 분자수준에서 모사하고 이해하고자 하는 노기체의 확산계수와 비교를 통하여 확산거동에 대한 이해를 높이고자 시도하 였으며, 기체확산계수가 관능기 력들을 기울이고 있으며, 실험적인 결과들과 모사결과를 비교하여 고분자의 설계나 기체분자의 거동의 이해를 하는데 기여를 하고 있다. 본 연구에서는 기체분리막 으로서 사용이 되는 폴리이미드나 폴리벤즈옥사졸같은 탄화수소계 고분자분리 막의 기체 분자의 투과거동을 모사하고자 하였다. PEG를 포함하는 폴리이미드 공중합체에서 폴리에틸렌 부분과 같은 관능기그룹의 밀도로 확산계수를 계산하여 그룹이 많은 부분에서 증가하는 것을 확인하였고, 이는 기체투과 테스트의 실험데이터와 거의 일치하였다.
        112.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to examine the exposure risk of thermal paper ingredients by analyzing skin permeation using an in vitro Franz cell. Thermal printer papers are usually used for receipt papers, and the skin of shop assistant is continuously exposed to hazardous ingredients of thermal papers. The skin permeation risk of thermal paper ingredients, including bisphenol A and toluene, was determined using an in vitro Franz diffusion cell method using hairless mouse full skin and human cadaver epidermis. Bisphenol A, a major component in each thermal paper, showed moderate skin penetration. Most skin absorption rates were similar in both hairless mouse full skin and human cadaver epidermis. The possible risk of exposure to toxic substances in thermal paper was confirmed from this study. These is results are expected to contribute to establishment of management regulations for thermal papers.
        4,000원
        113.
        2016.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        To alloy high melting point elements such as boron, ruthenium, and iridium with copper, heat treatment was performed using metal oxides of B2O3, RuO2, and IrO2 at the temperature of 1200 oC in vacuum for 30 minutes. The microstructure analysis of the alloyed sample was confirmed using an optical microscope and FE-SEM. Hardness and trace element analyses were performed using Vickers hardness and WD-XRF, respectively. Diffusion profile analysis was performed using D-SIMS. From the microstructure analysis results, crystal grains were found to have formed with sizes of 2.97 mm. For the copper alloys formed using metal oxides of B2O3, RuO2, and IrO2 the sizes of the crystal grains were 1.24, 1.77, and 2.23 mm, respectively, while these sizes were smaller than pure copper. From the Vickers hardness results, the hardness of the Ir-copper alloy was found to have increased by a maximum of 2.2 times compared to pure copper. From the trace element analysis, the copper alloy was fabricated with the expected composition. From the diffusion profile analysis results, it can be seen that 0.059 wt%, 0.030 wt%, and 0.114 wt% of B, Ru, and Ir, respectively, were alloyed in the copper, and it led to change the hardness. Therefore, we verified that alloying of high melting point elements is possible at the low temperature of 1200 oC.
        4,000원
        114.
        2015.12 KCI 등재 구독 인증기관·개인회원 무료
        Background: Diffusion weighted imaging which is clinically useful in the differential diagnosis of the benign and malignant thyroid nodules needs a distortion improvement as thyroid is located just below the skin which causes the susceptibility artifact on the image. Purpose: To reduce susceptibility induced distortion for diffusion weighted MRI(DWI) in the thyroid by compensating the anatomic geometry with the material similar to human tissue density and provide images with a better diagnostic value. Materials and methods: An exam was performed to select the most effective material in reducing the susceptibility difference between tissue and air by using the self produced phantom. On the basis of the result, the selected material was processed and the thyroid diffusion weighted images were acquired to estimate the optimum thickness comparing the distortion and error rate variation of the magnetic susceptibility. Results: As a result of the phantom experiment sulfur, borax, normal saline, silicon pad, flour, air, silicon and graphite were effective in reducing the tissue and air susceptibility differences in order. In the post analysis borax, sulfur, flour and silicone pad had no significant difference in reducing the tissue and air susceptibility differences. Considering the magnetic field becomes uneven at the both edges inside the MRI bore, the experiment was performed by dividing the phantoms into three sections (upper, mid and lower). The susceptibility difference was statistically same among the three sections. In the post analysis using the air as reference borax, sulfur and silicon pad showed little susceptibility difference than the air. The selection of the materials were performed using the Likert 5 point scaling, where the silicon pad was proved as the most effective material. Based on this, the silicone pad was engaged on the patients’ neck. The images obtained after application of the silicone pad showed less error and distortion on both lobes of thyroid and it was statistically meaningful. As a result of the variance analysis the optimum thickness of the silicon pad was 2cm as it was not statistically significant over 2cm on the both lobes. Conclusion: In conclusion, the use of a silicon pad can significantly improve the diagnostic value of the MRI image by compensating the complex magnetic environment commonly encountered in clinical thyroid imaging, not affecting the image contrast.
        115.
        2015.12 KCI 등재 구독 인증기관·개인회원 무료
        Pulpose : Although diffusion tensor imaging (DTI) has been widely used for the quantitative analyses of the integrity of white matter in the brain in clinical and research fields, quality assurance (QA) for DTI has not been fully established. The purpose of this study suggests a QA guideline for DTI using the American College of Radiology (ACR) Magnetic resonance imaging (MRI) head phantom. Materials and Methods : All experiments were performed using 1.5T and 3.0T scanners (InteraAchiva 1.5T and AchivaTx 3.0T; Philips Medical Systems, Netherlands) equipped with an 8-channel SENSE head coil. The standard axial SE T1-weighted MR images with 6, 15 and 32 directions of DTI were obtained using the standard scanning protocol “Phantom Test Guidance for the ACR MRI Accreditation Program” . Slice thickness and slice gap were set at 5 mm for standard axial SE T1 images and echo planar images, and then both images were compared. Reproducibility was tested with 7 repeat scans in 1.5T scanner and 10 repeat scans in 3.0T scanner. Between the scanning, the ACR MRI phantom was completely removed from coil and was repositioned for each new trial. Parameters for the QA protocol are shown in Table 1. The ACR MRI phantom was stored in the scanner room for at least 24 hours before an experiment, and the room temperature was measured before scanning for DTI. Results : There were statistically significant differences in the geometric accuracy between the 1.5T and 3.0T two scanners across all scan directions. The top-to-bottom diameters had a 11.3 mm error in 1.5T scanner and a 7.2 mm error in 3.0T scanner. Image intensity uniformity tests were significant in 6, 15, and 32 directions at 1.5T and 3.0T comparative analysis (p < 0.001). Additionally, percent signal-ghosting tests were significant in all directions, such as 6, 15 and 32 directions, in both 1.5T and 3.0T scanners (p < 0.001). The DTI images from 1.5T scanner had a ghosting ratio less than 0.025 at 1.5T scanner while 3.0T scanner had a ghosting ratio greater than 0.045. The low-contrast object detectability had a significant differences in 6, 15, 32 directions at 1.5T and 3.0T systems (p < 0.001). The DTI images from 1.5T system showed 2.85 spokes in 6 directions, 14.00 spokes in 15 directions, and 26.14 spokes in 32 directions. The DTI images from 3.0T system had 7.80 spokes in 6 directions, 32.20 spokes in 15 directions, and 37.30 spokes in 32 directions. Image distortion was significant in the anteriorposterior (AP) direction (p <0.001), but was not significant in right-left (RL) direction (p = 0.359). Image distortions in 1.5T scanner were 6.93 mm for the AP direction and 0.26 mm for the RL direction while the same for 3.0T system were 8.55 mm for the AP direction and 0.28 mm for the RL direction. For the FA and the ADC values, we acquired significant results in 6, 15, and 32 directions for 1.5T and 3.0T scanners (p < 0.001). The FA values were relatively lower for 3.0T system than for 1.5T system, and 32 directions for 3.0T scanner had the lowest value. The ADC values of 3.0T system were lower than those of 1.5T system, and 15 and 32 directions had the lowest values. Conclusion : This study is the first trial using the ACR MRI phantom that is easily accessible in most clinical MR centers. Also, the present study using the ACR MRI phantom suggests a QA method for DTI with high reproducibility and easy accessibility.
        116.
        2015.12 KCI 등재 구독 인증기관·개인회원 무료
        목 적 : DWI 영상은 뇌경색(infarction)과 종양(tumor) 검사를 비롯해서 널리 사용되고 있다. 주로 EPI를 이용한 경우에는 검사시간이 짧아 유용하게 이용되지만 특정 검사부위에서 영상왜곡이 심하게 발생하므로, TSE를 이용한 영상과 비교 평가하고자 한다. 대상 및 방법 : 지원자 중 정상군 6명(성인남자 6명, 45.25+10.24)을 대상으로 3.0T 자기공명영상장치(Philips Ingenia system: Nederland Version R5.1.7)의 Head coil을 이용하여 데이터를 획득하였다. 검사기법으로는 Single-shot EPI기법과 TSE기법을 사용하였으며 매개변수로는 TR/TE:Shortest, FA:90◦°, Thickness:2mm, Nogap, SENSE Factor:2, b-value:1000(s/mm2)과 각각 FOV:200mm, Matrix:111x112와 FOV:180mm, Matrix:100x100으로 검사하였다. Signal Intensity의 측정은 Philips사의 Viewforum을 사용하였으며, NEX값은 1, 2, 3, 4로 변화시켰다. Cerebellum의 Anterior lobe(Cerebellar nuclei)와 Posterior lobe(Inferior semilunar lobule)에 각각 ROI의 Signal Intensity(SI)를 측정하여 Signal to Noise Ratio(SNR)를 비교 평가하였으며, 영상왜곡 정도를 방사선사 5명이 평가하였다. 결 과 : Cerebellum의 Anterior lobe과 Posterior lobe에서 EPI기법을 사용한 경우는 NEX값이 증가함에 따라 SNR값이 각각, 163.93±1.52, 102.70±1.39, 80.70±1.34, 67.56±1.28과 156.91±1.85, 125.64±1.43, 99.07±1.39, 84.59±1.53으로 측정되었으며, TSE기법을 사용한 경우는 각각, 357±1.42, 158.00±1.04, 69.93±1.48, 55.89±1.87과 368.30±1.72, 175.55±1.62, 76.18±1.79, 61.21±1.03으로 측정되었다. 영상왜곡 평가에서는 EPI기법에서 심하다가 9명으로 가장 높았으며, TSE기법에서는 매우 심하지 않다가 11명으로 가장 높게 나타났다. 결 론 : EPI기법에서는 NEX가 증가함에 따라 SNR이 감소하지만 상대적으로 감소폭이 적고, 영상왜곡 정도와 육안적 영상평가에서는 변화가 없었으며, TR이 증가하면서 검사시간이 증가하였다. TSE기법에서는 SNR의 감소폭이 상대적으로 크고, 영상왜곡 정도에는 변화가 역시 없었지만 육안적 영상평가에서는 변화가 있었으며, TR의 변화 없이 검사시간이 증가하였다. 그러므로 국소적으로 왜곡이 심한 부위에서는 TSE기법의 DWI를 이용하여 3NEX 이상을 주어 검사하는 것이 병변진단에 유용하다.
        117.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 확산강조영상은 뇌신경계에서 ischemia, infarction, inflammation, infection, tumor등 다양한 병변을 진단하는데 유용하다. 하지만 척추 확산강조영상은 심장의 운동, 호흡이나 연하에 의한 움직임과 척추체가 가깝게 있어 자기화율의 급격한 변화 등의 이유로 distortion과 artifact가 많이 발생하여 좋은 영상을 획득하기 어려웠다. 확산강조영상에서 영상의 distortion과 artifact를 변화시킬 수 있는 인자는 SENSE factor와 voxel size이다. 따라서 본 논문에서는 흉추 확산강조영상에서 SENSE factor와 voxel size를 변화시켜 영상을 획득 후 이를 비교평가 하고, 영상의 distortion, artifact 줄여 진단적 가치를 높이는 것이 본 논문의 목적이다. 대상 및 방법 : 척추질환이 없는 건강한 지원자 10명(남자: 7, 여자: 3, 평균연령: 29.6세)을 대상으로 하였다. 검사장비는 Ingenia 3.0T MRI (philips medical system, Netherlands)를 사용하였고, 신호수집 코일은 DS posterior coil을 사용하였다. FOV 240×184, B-factor 0, 1000 s/mm², slice thickness 4 mm, NEX: 10, TR과 TE는 장비에서 제공하는 가장 짧은 값을 사용하고 SENSE factor를 1, 2, 3으로 설정 후각 SENSE factor에서 voxel size를 1×1, 2×2, 3×3 mm로 변화시켜 영상을 획득하였다. 정량적 평가는 T2/SAG영상을 기준으로 Thoracic Spine 6th body에서 spinal cord까지의 거리를 각각 측정하여 distortion을 평가 하였고, 정성적 평가는 영상의학과 교수 1명, MRI 전문 방사선사 2명이 5점 척도로 영상의 artifact, distortion, 병변 검출 능력 등 전체적인 영상의 질을 비교평가 하였다. 통계적 유의성은 Wilcoxon signed rank test(SPSS 18.0K for windows)를 통해 검정하였고 p-value는 0.01미만인 경우에 통계적으로 유의하다고 판정하였다. 결 과 : 고정된 SENSE factor에서 voxel size 변화에 따른 distortion의 정량적 평가결과 SENSE factor 1에서 voxel size가 1×1, 2×2, 3×3으로 변화할 때 기준점에서 측정한 10명의 지원자의 평균길이는 6.54 mm, 5.33 mm, 4.79 mm, SENSE factor 2에서 평균 4.22 mm, 3.33 mm, 3.14 mm, SENSE factor 3에서 평균 3.04 mm, 2.63 mm, 2.29 mm로 측정 되었다. 동일한 SENSE factor에서 voxel size가 3×3일 때 영상의 distortion이 가장 많이 감소되었으며 동일한 voxel size에서는 SENSE factor가 3일 때 영상의 distortion이 가장 많이 감소되었다. 정성적 평가에서는 distortion, artifact의 발생정도와 척추체와 척수에서의 병변 검출 능력을 5점 척도(평가 불가: 1, 나쁨: 2, 보통: 3, 좋음: 4, 아주 좋음: 5)로 평가하였다. SENSE factor 1, voxel size 1×1, 2×2, 3×3으로 변화할 때 평균 2.23점, 2.30점, 2.33점으로 비교적 낮은 점수를 받았고 SENSE factor 2, voxel size 1×1, 2×2, 3×3으로 변화할 때 평균 2.86점, 4.20점, 4.13점, SENSE factor 3, voxel size 1×1에서 3.10점, 2×2, 3×3에서 평균 4.66점으로 가장 진단 가치가 높은 영상으로 평가되었다. 각각의 SENSE factor와 voxel size의 변화에 따른 영상의 distortion의 감소의 통계적 유의성을 알아보기 위해 Wilcoxon signed rank test로 검정한 결과 모두 p<0.01 로 나타났다. 결 론 : 확산강조영상은 뇌 질환에서 뿐만 아니라 척추와 spinal cord lesion을 감별하는데 매우 유용하다. 임상에서 Thoracic spine 확산강조영상 검사 시 본 논문에서 실험하여 얻은 결과처럼 SENSE factor: 3, voxel size: 2×2 또는 3×3을 선택하여 영상을 획득한다면 영상의 artifact, distortion이 감소되어 진단적 가치가 높은 영상을 만들 수 있을 것으로 사료된다.
        4,000원
        118.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 의료영상평가의 특성상 전문가의 정성적인 평가에 의존함에 따른 비용과 시간의 제약에 대한 문제점을 해소하고자 본 연구에서는 MR 확산 텐서 영상에 Compressed sensing 기법을 적용하여 복원한 영상과 원본 영상과의 정확도를 정량적으로 평가하기 위하여 fiber tract을 수치적으로 나타낼 수 있는 변수들의 상관관계를 분석하여 정량적 평가 방법의 기준을 제시하고자 한다. 대상 및 방법 : 2014년 3월부터 5월까지 본원에 내원한 환자 중 평균 나이 53.8 ± 15세(남성 3명, 여성 2명)의 뇌 질환이 의심되는 환자들에 대해 3.0T MRI(Archiva, Philips medical system, Netherlands)를 사용하여 뇌 MR 확산 텐서 영상을 얻었다. 획득한 원본 확산 텐서 영상들은 Compressed Sensing기법을 이용하여 under-sampling 후 영상복원의 정도(reduction factor)를 달리하여 재구성하였다. 각 신경 섬유 다발 영상들의 Fiber statics를 분석하여 신경 섬유의 총 개수, 한 단위 복셀 당 신경 섬유의 개수, 확산 텐서 영상에서 비등방성을 나타내는 고유의 값인 FA, RA, VR값과 평균 확산 계수(Mean Diffusivity), Radial Diffusivity, Eigen Value, Tensor Trace로 총 9개의 변수 값을 구하였다. 정성적 분석은 영상의학과 판독의 1명, 5년 이상 MRI 근무 경력이 있는 방사선사 4명에게 원본 영상과 비교하여 보았을 때 복원 영상이 진단적 가치가 있는지를 매우 양호하지 않다(1), 양호하지 않다(2), 보통(3), 양호하다(4), 매우 양호하다(5)의 항목으로 나누어 각각의 영상에 대하여 설문 조사를 하였다. 정성적 분석 결과와 변수들의 값을 회귀 분석을 통해 상관관계를 분석하여 식을 도출하였다. 결 과 : 25개의 training/test dataset에 대한 각 변수에 대한 가중치들을 회기 분석하여 구한 값을 통해 구한 test dataset의 정량적 분석과 전문가 집단의 정성적 분석과의 오차는 평균 19%를 보였으며 이 가중치 값들을 바탕으로 뇌 MR 확산 텐서 영상의 고속화에 다른 정확도를 정량적으로 평가하기 위한 방법의 식을 얻을 수 있었으며 평균 11%의 오차율을 보였다. 또한 sample data 수를 증가하여 결과를 예측해 보기 위하여 붓스트랩을 적용하여 15개의 복원된 뇌신경 섬유 영상의 원본과의 차이를 나타낸 변수 값들의 데이터를 training set으로 정하여 410개의 sample data를 바탕으로 구해진 가중치들의 값을 통해 얻은 식은 평균 7%의 오차율을 보였다. 결 론 : 전문가들의 정성적 평가에서 5명 모두 동일한 의견을 나타냈을 때는 8%에 지나지 않았으며 각 영상의 정성적 평가 평균값과 다른 의견을 보인 전문가들의 오차율은 평균 36%였다. 따라서 본 연구의 11%와 7% 오차율은 전문가들 중에서 이견을 보일 수 있는 오차율 보다 작아 허용 가능한 범위에 있는 것으로 보이며 이 두 식은 정확도를 평가하는 데 있어 정성적 평가방법을 충분히 대체할 수 있을 것으로 보인다. 하지만 정량적 평가의 정확도를 좀 더 높이기 위해서는 오차를 줄이기 위해 더 많은 training/test dataset의 실험을 추가하여 개선해 나아가면 될 것으로 보인다.
        4,000원
        119.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적 : 확산강조 자기공명영상 검사 시 피사체의 X축 위치에 따른 영상왜곡과 신호강도의 정도 차이를 비교 분석하여 정확한 검사를 위한 지침을 설정함으로써 임상에서의 진단효율을 향상시키고자 한다. 대상 및 방법 : 자체 제작한 팬텀은 아크릴 상자에 외경이 16mm 높이가 55mm인 원통형 플라스틱 시약병 44개를 4행 11열로 시약병의 중심으로부터 각각 45mm 간격으로 배열하였으며, 지방을 표현하기 위한 마가린과 물을 채워 제작하였다. 사용된 장비는 3T Skyra (Siemens Germany) 와 18Ch Body array coil을 사용하였으며 확산강조영상 parameter는 scan slice thinkness 3mm, slice gap: 0mm, FOV: 450×450, TR: 5000, TE: 73/118, Matrix: 126×126, slice number: 15, scan time: 9min 45sec, NEX: 3, phase encoding 방향을 RL(right to left)로 설정하여 관상면 영상을 획득하였으며, b-value 0, 400, 1400 으로 설정하여 scan 하였으며, T2 지방소거 영상을 같이 획득하여 환자 table의 iso-center를 기준으로 X축의 위치에 따른 영상왜곡과 신호강도의 차이를 서로 비교 분석하였다. 비교분석 프로그램으로는 Image J를 사용하였고 통계 프로그램인 SPSS v18.0을 사용하였다. 결 과 : T2 지방소서 영상에서 fat과 water의 영상왜곡과 신호강도 차이는 거의 없었다. 이 때 X축의 위치에 따른 평균값은 통계적 유의하였다(p<0.05). DWI 영상에서 b-value가 0, 400 인 경우 patient table 중심으로부터 좌우 2열까지는 큰 변화가 없었으나, 제 3열부터 영상의 왜곡과 신호강도의 감소가 발생하였고, 제 4열의 위치에서는 영상의 왜곡과 신호강도의 감소가 급격하게 발생하였다. b-value가 1400인 경우는 영상의 왜곡은 patent table 중심으로부터 좌우 1열까지는 큰 변화가 없었고, 제 2열 이후부터 영상의 왜곡이 발생하였으며, 신호강도는 제 2열까지는 큰 변화가 없었으나 제 3열의 위치에서부터 감소가 발생하였고, 제 4열의 위치에서는 영상의 왜곡과 신호강도의 감소가 급격하게 발생하였다. 이때 모든 실험에서 11개의 시약병 중에서 가장 바깥쪽의 시약병은 영상으로 확인이 안 되었으며 9개의 시약병만 영상에서 확인이 되었다. 제 5열은 모든 부분에서 식별 불가능하였다. 이 때 X축의 위치에 따른 평균값은 통계적으로 유의하였다(p<0.05). 결 론 : T2 FS 영상에서는 patient table의 중심에서 180mm 이상에서 현저한 영상의 왜곡과 신호강도의 감소가 있었고, 확산강조영상에서는 90mm 이상 벗어나게 되면 현저한 영상의 왜곡과 신호강도의 감소가 생기게 되고 180mm 이상에서는 영상을 식별할 수 없게 된다. 그러므로 사지와 같이 patient position을 위치하기 어려운 검사에서 특별히 유의하여 진단적 가치를 갖는 영상을 만들어야 한다.
        4,300원
        120.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we proposed novel continuous tone representational method based reaction-diffusion model. We extended previous related research of hedcut-style rendering by adding controllability to reaction-diffusion based texture generation method. These controls includes pattern size and pattern direction for various style rendering. Our method is comparable with stipping method which can generate artistic style rendering with continuous tone representation of input images. While stippling can show stable tonal results for low density points area, high density region which stipples redundant is suffer from non-linear brightness. On the contrary, our method shows stable tonal results for all brightness spans. We also present anisotropic diffusion for directional pattern generation which can applied to more various style rendering. In this contribution includes mathematical model and results of various style.
        4,000원