검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 24

        1.
        2023.11 구독 인증기관·개인회원 무료
        In general, systems are developed by repeatedly performing the processes of design, analysis, manufacturing, and performance testing. In particular, systems with temperature, pressure, and flow rate often utilize computational fluid dynamics tools at the design stage. In this paper, we aim to verify the reliability of the analysis results of Solidworks Flow Simulation, which is widely used in heat flow analysis at the design stage. A tube furnace was manufactured, various experiments were performed, and a study was conducted to compare the analysis results. The details of the experiment are as follows. First, an experiment was conducted in which the heater was heated to 900°C without insulating the exposed part of the tube. The detailed contents of the experiment are as follows; - Heating heater and measuring temperature without supplying flow inside the tube, - Tube flow supply (25°C, 15 lpm air) and heater heating/temperature measurement. Second, an experiment was performed in which the exposed part of the tube was insulated (thickness 50 mm) and the heater was heated to 900°C. The detailed contents of the experiment are as follows; - Insulate the outside of the tube except for the flanges at both ends of the tube, and heat the heater and measure the temperature without supplying flow inside the tube. - Insulate the outside of the tube except for the flanges at both ends of the tube, supply flow rate inside the tube (25°C, 15 lpm air) and measure heater heating/temperature. - Insulate the flange of the flow supply section, heat the heater and measure temperature without supplying flow inside the tube. - Insulate the flange of the flow supply section, heat the supply air (277°C, 15 lpm) and measure the temperature using a heating gun without heating the heater. - Insulate the flange of the flow supply section, supply heated air (277°C, 15 lpm) and measure heater heating/temperature. - Insulate the flange of the flow supply section and measure temperature according to heater heating (900°C) and supply temperature (25°C, 277°C 15 lpm). The following results were derived from the experimental and analysis results. - When the exposed part of the tube is insulated, the temperature inside the tube increases and the steady-state power decreases compared to non-insulated. - In areas with insulation, the temperature error between experiment and analysis results is not large. - When flow rate is supplied, there is a large temperature error in experiment and analysis results. - The temperature change after the center of the heater is not large for a temperature change of 15 lpm flow rate. From these results, it can be seen that Solidworks Flow Simulation has a significant difference from the experimental results when there is a flow rate in the tube. This was thought to be because the flow rate acts as a disturbance, and this cannot be sufficiently accounted for in the analysis. In the future, we plan to check whether there is a way to solve this problem.
        2.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, in order of to reflect the mold deformation in the injection molding process to design of mold, the mold deformation was analyzed by performing flow and structural analysis. The 5 inch LGP(light guide plate) mold, platen and tie bar were modeled and applied to the analysis. The result of melt pressure from flow analysis was extracted for use as boundary conditions acting on the mold surface in the structural analysis. In order to evaluate the accuracy of simulation analysis results, injection molding was performed under the process conditions of simulation. As a results, the mold deformation during injection molding tends to be similar that of injection pressure, and it is confirmed that it shows the behavior and properties of melt resins. Compared with the simulation and experiment, the error of the maximum mold deformation in the injection phase was 4.20%.
        4,600원
        3.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Conventional rotary sawing machine for cutting lumber generates severe amount of dust scattering to the environment. In this research, the design improvement of the rotary sawing machine is achieved to significantly reduce the dust scattering by the design process utilizing computational fluid dynamics (CFD) analysis. Several design candidates for the design improvement of the rotary saw system were proposed and modeled, and CFD analyses were performed to choose the best design in viewpoint of the least dust scattering. CFD analysis proved to be very useful to predict the characteristics of the air flow inside the saw system. The movement of dust particles with the air flow during the sawing process was analyzed for various design features of the saw system. The most efficient design to minimize the amount of dust particles ejected from the saw system was chosen based on the CFD analysis results. Then, the prototype of the best candidate of the improved rotary saw machine was built and the amount of dust particles were measured to verify its performance.
        4,000원
        4.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, measures for reducing noise and vibration of a railroad station are actively being developed to enhance its property value and comfort level of passengers. In this paper, the applicability of the recently developed vibration mitigation method utilizing a platform TMD (Tuned Mass Damper) by installing a spring-damper system beneath the platform is experimentally verified using a bench scale structure. The two-story bench scale structure is built to simulate a real railroad station, and vibration reduction effect is verified by comparing acceleration before and after applying the platform TMD at the 2nd floor of the structure. The design parameters of the platform TMD system is determined based on vibration analysis result and the MTMD (Multiple TMD) theory recently developed to enhance the effectiveness of the platform TMD method. The vibration is excited to the bench-scale structure using a vibrator. The performance test result for a spring-damper system is also presented. The result of the experiment reveals that the platform TMD method can reduce the vibration of the bench-scale structure by greater than 5dB(V).
        4,000원
        5.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the light weight and the safety of automobile are the important targets of automotive design and the parts for car have been substituted the plastic or the porous material for the steel material. As the aluminium foam has many pores at its surface, it has the fatigue property of bonded face which differs from general material. In this study, two dimensional model is designed and performed with the fatigue analysis as the variable(θ value) becomes the slant angle of bonded face at the specimen with the aluminium foam. As the analysis result on the models with the slant angles of 6°, 8° and 10°, the bonding forces are disappeared when the fatigue loads are repeated during 4000 cycle, 4500cycle and 5000cycle respectively. By comparing with the analysis results of three models, the fatigue cycle to endure fatigue load becomes larger as the slant bonded angle becomes higher. So, the structural safety can be seen by applying only as only a simulation of finite element method instead of the experiment where much cost and time is spent. In this study, the configuration of aluminum foam is designed with the shape of TDCB Mode II. The shear fatigue strength of the bonded structure can be evaluated by the analysis program of ANSYS.
        4,000원
        6.
        2012.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구진은 최근 U자 형태인 액체댐퍼의 수직관을 다수의 셀(사각 기둥)로 나누어 셀 상부를 개폐함에 따라 다양한 고 유진동수를 쉽게 재현하는 새로운 멀티셀 액체댐퍼를 제시하였다. 이러한 댐퍼를 1층 건물 모형에 설치하여 진동대 실험을 수행하여 건물응답이 감소되는 것을 검증하였다. 64층의 풍응답인 가속도를 제어할 수 있도록 댐퍼를 설계하기 위하여 건 물을 1자유도계로 축소하였다. 가속도 기반 상사비인 1/20를 적용하여 1층 건물 모형과 새로운 댐퍼를 제작하였다. 설계 진 동수인 0.65Hz가 구현되도록 모형건물의 질량과 강성을 쉽게 조절할 수 있도록 탈부착식으로 제작하였다. 모형건물은 중량 을 부담하는 질량부와 하부에 스프링과 LM guide가 설치된 구동부로 나누어서 제작되었다. 18개의 셀을 가지는 액체댐퍼 를 제작하여 고유진동수 조절 범위가 0.65Hz~0.81Hz인 것을 파악하였다. 대형 진동대에 설치한 모형건물의 일방향 가진을 통하여 모형의 응답을 측정하고 모형상부에 멀티셀 액체댐퍼가 설치되었을 경우 모형의 응답을 측정하여 비교하였다. 진동 대 가속도를 입력과 모형건물의 가속도를 출력으로 하는 전달함수를 통해 결과를 나타내었다. 예상한 바와 같이 멀티셀 액 체댐퍼의 고유진동수를 건물의 진동수에 동조시켰을 경우 건물의 가속도 응답이 감소함을 알 수 있었다.
        4,000원
        7.
        2009.03 구독 인증기관 무료, 개인회원 유료
        This paper proposes a tuned liquid column sloshing damper(TICSD) and its optimal design to mitigate bidirectional responses of building structures. The proposed damper acts as a liquid column vibration absorber (LCVA) and a tuned sloshing damper(TSD), respectively, in both principal axes of building structures. Optimum designs of the TLCSD addresses the minimizing in terms of live load, area and volume due to its installation, comparing to each installation with two dampers in two principal directions, respectively. Numerical results from optimum designs shows that the control robustness due to changes in the effective column length and the effective mass of the TLCSD superiors to that uses the head loss coefficient and damping nets in an existing liquid column vibration absorber(LCVA) and TSD. The TLCSD is designed according to the similarity laws of 76 story benchmark building model. Numerical model of the proposed TLCSD is derived based on the experimentally obtained transfer functions according to rotational angles.
        4,000원
        8.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는, 동조액체감쇠기(이하 TLD)만을 실험적 부분구조로 이용하여 TLD가 설치된 건축구조물의 지진 응답 제어효과를 평가하기 위한 실시간 하이브리드 실험법을 제안하고 진동대 실험을 통해 실험적으로 규명한다. 제안된 실험법에서, TLD가 설치된 전체구조물은 상부의 TLD와 하부의 구조물 부분으로 각각 실험적 그리고 수치해석적 부분구조로 나누어진다. 이때 부분구조 사이의 경계면에서 작용하는 하중 또는, TLD에 의한 제어력은 진동대에 설치된 전단형 로드셀에 의해 계측되며 진동대는, 계측된 경계면에서의 제어력이 상부에 작용하고 또한 동시에 기초에 지진하중이 작용하는 수치해석적 부분구조로부터 계산된 응답으로, 상부에 설치된 TLD를 가진하게 된다. 제안된 실험법에 의한 결과와 TLD와 건물모델 모두를 제작하여 실험하는 기존의 방법에 의한 실험 결과들은 서로 잘 일치하며, 이로써 본 논문에서 제안된 실험법을 이용하여 TLD의 제어성능을 손쉽게 평가 할 수 있음을 알 수 있다.
        4,000원
        9.
        2006.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물의 능동 진동 제어에 있어서 제어기의 제어입력의 포화와 건물의 파라미터 불확실성을 동시에 고려하는 제어 방법이 필요하다. 저자들의 이전 논문에서는 제어 입력에 포화가 존재하는 불확실한 선형 시불변계에 대하여 강인 안정성과 제어 성능이 보장되는 강인 포화 제어기를 제안하였다. 본 논문에서는 능동 질량 감쇠기 (AMD)가 설치된 건물의 능동 진동 제어에 대한 제안된 강인 포화 제어기의 유용성을 실험적으로 검증한다. 실험은 유압식 AMD가 설치된 2층의 건물 모형에 대하여 수행된다.
        4,000원
        10.
        2004.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        팻취 보강된 철근콘크리트 구조물 해석을 위한 p-version 비선형 유한요소 모델이 제시되었다. 이방성 적층평판이론에 기초를 둔 제안된 모델은 Total Lagrangian기법에 기초한 von Karman의 대변형-소변형률 이론과 증분소성이론(incremental theory of plasticity)을 적용하였다. 콘크리트의 경화법칙(hardening rule)과 그에 따른 파괴기준을 고려하고, 단부 계면 층분리 모델(plate-end interfacial debonding model) 즉, 보강판 끝 부분에서의 콘크리트 탈락에 대한 기준으로서 Oehlers Model과 Raoof and Zhang Model을 사용하였다. 콘크리트는 두께 방향으로 층상화기법(layered model)이 이용되며, 철근과 보강판은 환산층(smeared reinforcing layer)으로 계산되도록 하였다 적분형 르장드르 다항식이 형상함수로 사용되며, 절점에서의 응력값 산출을 위해 Gauss Lobatto 수치적분법을 사용하였다. 본 연구의 목적은 p-version 유한요소법을 사용하여 RC구조물에 대한 수피해의 정확도 및 모델의 단순성을 높인 수 있도록 하였다. 따라서, 철근과 콘크리트모델에 대한 이론적 근거는 기존의 연구문헌에 근거를 두었으며, 수치해석의 적정성은 팻취 보강된 RC보와 슬래브에 대한 문헌의 실험치 및 해석치와 비교 분석되었다.
        4,500원
        11.
        2002.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 지진을 받는 축소 3층 건물모델의 제어 실험에 관한 것이다. 건물모델에 대해 능동 질량 감쇠기를 사용하여 강인제어기인 \mu합성 제어기를 설계하고 실험적으로 검증하였다. 외란 입력과 제어용 출력에 적합한 주파수 가중함수를 설정하고 가중함수의 조합을 분석하여 최적의 \mu합성 제어기를 제시하였다. 실험 결과 백색잡음 가진 입력에 대한 RMS 응답에서 60-70%의 감소를 보여주었고, 축소 지진 입력에 대한 최대 응답에서 30-45% 정도의 감소효과를 나타내었다. 수치해석결과와 실험의 결과가 매우 정확히 일치하였으며 불확실성을 갖는 구조물에 대하여 제어기가 불확실성의 범위 내에서 강인하다는 것을 보여주었다.
        4,000원
        12.
        1999.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고유진동수를 사용하여 균열의 위치와 크기를 발견하는 비파괴 균열발견모델을 유도하고 Euler-Bernoulli 보를 대상으로 이 모델의 적합성을 검증하였다. 먼저, 균열위치예측모델과 균열크기예측모델로 이루어진 균열발견체계를 제시하였는데, 균열위치예측모델은 모드민감도와 고유진동수 사이의 선형적인 관계로부터 간접적으로 유도되었으며 균열크기예측모델은 균열발생에 의한 변형에너지의 손실을 진동특성치의 변화와 비교하는 동적 파괴역학적 방법으로부터 유도되었다. 다음으로, 기존에 발표된 양단-자유보에 대한 진동모드 실험결과를 사용하여 균열위치와 균열크기를 예측하고 평가하므로 균열발견모델의 적합성과 적용성을 실험적으로 검토하였다. 대부분의 손상시나리오에서 균열위치와 균열크기 예측치는 실제값과 근사하게 일치하였다.
        4,200원
        13.
        1991.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        적분방식에 의한 어군량추정법을 실험적으로 검증하기 위하여, 실험수조에서 50 kHz와 200 kHz의 주파수를 대상으로 모의어군의 분포밀도와 초음파산란강도의 관계를 검토하고, 또 계량어군탐지기의 정도를 개선하기 위한 문제들에 대하여 고찰을 행한 결과를 요약하면 다음과 같다. 1. 어체의 모의표적으로 이용한 steel ball (직영 35mm)의 실측 echo 파형은 이론 echo 파형과 잘 일치하였다. 2. 5 종류의 주파수에 대하여 고등어 (체장 36cm)의 반사주파수특성을 조사한 결과, 측정주파수가 변화함에 따라 어체에 의한 echo 신호의 진폭과 파형이 크게 변동하고 있음을 알 수 있었다. 3. 송수파기의 음속 내에서 5개/m 상(3)와 30개/m 상(3)의 표적 군이 서로 상하로 존재할 때, 상부 표적군의 존재에 의해 하부 표적군의 echo level이 -0.43 dB 감쇠하는, 소위 그늘효과(shadowing effect)가 발생하였다. 4. 동지나해에서 정박 중에 탐지한 고밀도 어군의 echo신호와 그 어군직하의 해저에서 산란된 echo 신호를 상호 연관시켜 분석한 결과, 어군층내에서 발생한 어군감쇠와 다중산란효과가 해저 echo 신호의 변동에 큰 영향을 미치고 있음을 알 수 있었다. 5. 정치망의 원통에 인망한 정어리의 단위체적당에 대한 분포밀도가 36마리/m 상(3)였을 때, 해저기녹이 소실되는 어군감쇠현상과, 어군 echo 신호가 해저까지 신장되는 다중산란현상이 동시에 발생하였다. 6. 50kHz와 200kHz의 주파수에서 표적군의 평균체적산란강도(:dB)와 표적의 분포밀도(σ:개/m 상(3))의 간에 다음의 회귀직선식을 얻었다. 50kHz : =-46.2+13.7 Log(σ). 200kHz : =-43.9+13.4 Log(σ). 7. 표적의 분포밀도가 5, 10, 15, 20, 25, 30 개/m 상(3)였을 때, 적분방식에 의한 추정치는 50kHz에서 2.0, 8.1, 9.9, 14.1, 19.2, 26.7 개/m 상(3)이었고, 200kHz에서는 2.0, 8.0, 9.1, 15.0, 20.1, 24.1 개/m 상(3)이었으며, 단위체적당에 분포하는 표적의 수가 많을수록, 그 추정치의 정도가 높아지는 경향을 나타내었다. 또한, 양주파수에서 분포밀도의 추정치는 실제보다 약 30%정도 과소추정되었다.
        4,300원
        14.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 효율적인 와류형 미필터 비점오염저감장치를 개발하고 검증하였다. 저감장치의 검증을 위해 오염물질을 이용하여 총 12개 형태(3개 강우강도×2개 상태×2개 단계)의 실험을 진행하였다. 실험은 (1) 모의유입량 산정(강우강도 2.5 mm/hr: 0.00152 m3/s, 강우강도 3.395mm/hr: 0.00206 m3/s, 강우강도 6.870 mm/hr: 0.00326 m3/s); (2) 오염물질 채취 및 투입(4개 입경 사이즈의 25%씩 혼합); (3) 오염물질 제거효율 측정으로 구성하였고, 장치 초기상태와 운영상태로 구분하여 수행되었다. 강우강도별로 분석한 결과, 모든 강우강도에서 초기상태 및 운영상태 모두 오염물질 농도가 감소하였으며, 유입수 대비 유출수 오염물질 제거효율에서도 오염물질을 환경부 기준 80% 이상 제거하는 결과를 보였다. 특히 제거효율이 시간이 지남에 따라 서서히 증가하여 약 90%를 상회하였으며, 초기상태보다 운영상태에서 오염물질 제거효율이 더 높은 것으로 나타났다. 따라서 본 연구에서 개발한 와류형 미필터 비점오염저감장치로 효율적인 비점오염원을 제거할 수 있음을 증명하였다.
        15.
        2018.04 서비스 종료(열람 제한)
        Prediction of the compressive strength of the maturity method has been studied by several researchers and has been applied to the construction of concrete structures. In order to apply the maturity method, which is a function related to temperature and time, it is important to measure the accurate temperature inside the concrete during the curing period. The purpose of this study is to verify the performance by analyzing sensitivity, measurement and transmission accuracy by exposing wireless embedded sensor to various curing environment.
        16.
        2017.11 KCI 등재 서비스 종료(열람 제한)
        Twisted string actuators (TSAs) are tendon-driven actuators that provide high transmission ratios. Twisting a string reduces the length of the string and generates a linear motion of the actuators. In particular, TSAs have characteristic properties (compliance) that are advantageous for operations that need to interact with the external environment. This compliance has the advantage of being robust to disturbance in force control, but it is disadvantageous for precise control because the modeling is inaccurate. In fact, many previous studies have covered the TSA model, but the model is still inadequate to be applied to actual robot control. In this paper, we introduce a modified variable radius model of TASs and experimentally demonstrate that the modified variable radius model is correct compared to the conventional variable radius string model. In addition, the elastic characteristics of the TSAs are discussed along with the experimental results.
        17.
        2015.04 서비스 종료(열람 제한)
        Recently, to assessing the deflection of structural member, video gauge was widely used in the field of structural maintenance. This paper is dealt with the laboratory experience on the video gauge for detecting the structural deflection from the digital Image. In this paper, real deflection from LVDT detected from model bridge in laboratory was compared with the measurement of the Video Gauge. The accuracy of the deflection measurement using the Video Gauge in the load of the bridge was verified.
        18.
        2013.10 서비스 종료(열람 제한)
        A method to measure rheological properties of cementitious materials through mini slump test has been previously suggested. In this study, experiments were performed to verify that method. As the mini slump test proceeds, the spreading diameter of the material were measured by using a digital image processing technique. From the measured spreading diameter versus time curve, the rheological properties were estimated and compared to the properties measured from the viscometer.
        19.
        2013.04 서비스 종료(열람 제한)
        The double frame system is composed of existing structure, external retrofit frame and hysteretic steel dampers installed between former two components. The DFS retrofit system dissipates the energy by plastic deformation of steel damper caused by relative displacement due to the differences in stiffness, weight, and eigenperiod of each components. The dynamic test with shaking table was performed to verify the seismic performance of the proposed DFS system
        20.
        2012.11 서비스 종료(열람 제한)
        In this study, principal check points in design of the damper were able to examine through the process of comparison between theoretical prediction and experimental verification for performance of high-damped rubber damper based on compressive deformation energy absorption.
        1 2