Outdoor storage fires have a significant impact on the surrounding environment, including adjacent storage facilities and buildings. Therefore, it is essential to review and manage the fire impact to minimize damage to human life and property on the outdoor storage fires. In this study, the heat release rate and radiant heat flux were simulated according to the fire time, wind veolcity, and presence or absence of water spray equipment in an outdoor storage facility fire, and the fire impact was analyzed. The outdoor storage was designed to simulate two scenarios on the outdoor storage fires containing gasoline, and FDS was used for fire simulation. As a results, when the water spray facility was not operating and the wind velocity was 5 m/s, the maximum radiant heat flux was 24.80 kW/m2, which exceeded the limit radiant heat flux of 20 kW/m2. When the water spray facility was operating and the wind veolcity was 10 m/s, the maximum radiant heat flux was 18.77 kW/m2, which did not exceed the limit radiant heat flux, indicating that the fire impact on adjacent storage facilities was relatively small.
This study aims to verify the impact of a metaverse-based safety education program on the fire safety awareness of elementary school students. Utilizing the National Fire Agency's 119 metaverse program, an educational program was implemented for two months, and the experimental group was examined using paired-sample t-tests, while comparisons with the control group were made using independent-sample t-tests. The results revealed statistically significant differences between the experimental and control groups in the area of fire prevention. Although no statistically significant differences were observed over time within each group, the overall average scores for the entire class improved across all areas. Based on these findings, the effectiveness of metaverse-based safety education is suggested; however, a significant difference compared to traditional education was not detected. The study concludes by exploring implications for considerations in the implementation of metaverse safety education in the future.
In this research, the dynamics equations for a demolition fire vehicle were formulated. This was done by developing an interface that allows co-simulation using ADAMS and MATHEMATICA. In this study, MATHEMATICA alone was used to calculate the constrained dynamics equations, to demonstrate the impact force and the constraint Jacobian of the end-effector as any desired location through the x, y and z axes. Then we mathematically derived a model for a unilaterally constrained multi-link. Assumptions about the fire demolition vehicle of the constraint coordinate and the impact issues of the model are discussed in the next sections. The estimation procedure for the dynamics equation showed good approximation results in terms of solving a reaching task problem.
The red imported fire ant, Solenopsis invicta, first arrived in Texas in 1956 and quickly spread, where it now occupies more than half the state. The ecological and economic impact of this invasive ant has been well-documented in the state. Ecologically, it reduces native arthropod fauna and has a big effect on ground nesting birds. Economically, it’s estimated that this pest ant costs the state $1.2B dollars annually, affecting both urban and agricultural areas. After failed federal efforts to eradicate the fire ant, the state of Texas invested in its own research and management program, as did several other states. However, the Texas program, the Imported Fire Ant Research and Management Program, was the largest state program with $1.25 M invested annually since 1997. Several important developments arose out of this program including research on the biology and management of fire ants as well as treatment recommendations. Results of these research and management efforts will be discussed.
본 연구에서는 LNG 공급계통시스템의 재기화 공정에서 배관 손상으로 인한 누출사고 발생시 LNG 성분 및 누출공의 크기에 따른 연소특성에 대한 피해범위를 산출하고, 피해영향을 해석하였다. LNG 성분에 따른 연소특성을 확인하기 위하여 7곳의 LNG 산지별 위험도를 확인한 결과 산지별 큰 차이를 보이지 않았으나, LNG 구성성분 중 메탄의 함유량이 많을수록 플래시화재 발생범위 및 증기운 폭발에 의한 과압이 발생하는 위험범위 그리고 제트화재 발생에 의한 열 복사량 피해영향이 다른 산지에 비해 비교적 낮음을 알 수 있었다. 또한 배관 누출공의 크기에 따라 누설, 파공, 파괴 3단계에 나누어 위험 범위 및 폭발에 미치는 영향에 대한 연구를 수행하였으며, 플래시화재로 인한 피해영향범위를 계산하고, 이에 따라 LNG 누출시 화재가능 위험범위를 확인했으며, 과압의 영향 및 복사열로 부터의 피해범위를 예측할 수 있었다. 이를 통해 LNG 조성 및 배관 누출공의 크기가 화재 및 폭발에 미치는 영향을 예측할 수 있었다.
콘크리트 구조물이 화재 손상을 입을 경우 노출온도 및 지속시간에 따라 구조물의 심각한 성능 저하를 야기하며, 콘크리트의 재료 물성 저하를 수반한다. 화재 손상을 입은 콘크리트 구조물의 재사용여부 및 보수보강 판단을 위해서는 손상 직후 및 재양생 조건에 따른 주요 손상 부위의 면밀한 손상 평가가 필요하다. 본 연구에서는 재양생 조건에 따른 화재 손상을 입은 콘크리트의 재료물성 회복에 관한 실험적 연구 를 수행하였다. 화재 손상을 입은 콘크리트 시편을 상대습도 및 재양생 기간을 달리한 재양생 조건을 적용하였으며, 충격공진기법을 도입하여 콘크리트 시편의 화재 손상 전후 및 재양생 이후의 동탄성계수를 측정하여 손상 정도를 평가하였다. 측정된 결과로부터 재양생 조건 중 높은 상 대습도 조건에서 지배적으로 재료물성의 회복이 발생하였다. 추가적으로 콘크리트 시편의 동탄성계수 및 인장강도의 직접적인 비교 및 선형 회귀분석을 수행하여 재양생 조건에 따른 영향을 분석하였으며, 이를 토대로 높은 습도 조건에서 동탄성계수의 회복이 인장강도에 비해 두드 러지게 나타남을 확인하였다.
In this study, the applicability of impact-echo method for assessment of residual strength of fire-damaged concrete is investigated. A series of standard fire test is performed to obtain fire-damaged concrete specimens. Impact-echo tests are executed on the specimens and the responses are analyzed. Compressive strengths of the fire-damaged concrete are evaluated and correlated with the ultrasonic wave velocities determined from the impact-echo responses. The effectiveness of impact-echo based ultrasonic wave velocity measurement for assessment of residual strength of fire-damaged concrete is discussed.
현대 사회에서 차량을 비롯한 선박, 항공기와 같은 각종 수송수단들은 그 용도와 형태도 다양하고 널리 보급되어 있을 뿐만 아니라 각 분야에서 없어서는 안 될 필수품이 되어 있다. 그러나 수송수단의 수와 활용빈도수가 증가함에 따라 그로 인한 차량화재, 선박화재 그리고 항공기화재 등과 같은 특수화재의 발생에 따른 재산 및 인명피해의 문제점들도 함께 늘어나고 있는 실정이다.
또한, 전투시스템의 경우, 외부 충격탄과 폭발물에 의한 충격으로 순간 화재의 위험성 및 사고 가능성이 매우 높기 때문에 이와 같은 화재 및 폭발에 의한 사고예방을 위하여 체계적이고 종합적인 원인 분석과 시스템의 취약성 분석이 필요하다.
따라서 본 연구에서는 이러한 문제점을 해결하고 과학적이며 체계적인 대응방안을 수립하기 위한 기초 자료를 확보하고 이를 통한 전투시스템의 외부충격에 의한 순간화재의 발생예측프로그램을 개발하기 위한 연구를 수행하였다.
연구방법은 각종 수송수단에서 사용되는 차량 내장재 및 오일을 대상으로 연소특성 및 화재하중을 분석하였으며, 실제 사격에 의한 착화유무를 확인하고자 실제 소총사격 실험 및 실내사격장의 사격실험도 병행하였다.
전투시스템의 순간화재발생에 대한 예측프로그램을 개발하기 위해서 실험을 통해 확보한 데이터들로부터 물성 DB를 구축하였고, FTA 방법을 이용하여 순간화재의 발생확률을 산출하였는데 최종적으로 이러한 결과들을 반영하여 Microsoft Visual Studio 2008을 도구로 Microsoft Windows 7의 운영체제에서 실행되는 순간화재 발생 예측프로그램을 개발하였다.