검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 37

        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic fragility curves present the conditional probability of damage to target structures due to external seismic load and are widely used in various ways. When constructing such a seismic fragility curve, it is essential to consider various types and numbers of ground motions. In general, the earthquake occurrence characteristics of an area where the target structure of the seismic fragility curve exists are analyzed, and based on this, appropriate ground motions are selected to derive the seismic fragility curve. If the number of selected ground motions is large, the diversity of ground motions is considered, but a large amount of computational time is required. Conversely, if the number of ground motions is too small, the diversity of ground motions cannot be considered, which may distort the seismic fragility curve. Therefore, this study analyzed the relationship between the number of ground motions considered when deriving the seismic fragility curve and the parameters of the seismic fragility curve. Using two example structures, numerical analysis was performed by selecting a random number of ground motions from a total of two hundred, and a seismic fragility curve was derived based on the results. Analysis of the relationship of the parameter of the seismic fragility curve and the number of selected ground motions was performed. As the number of ground motions considered increases, uncertainty in ground motion selection decreases, and when deriving seismic fragility curves considering the same number of ground motions, uncertainty increases relatively as the degree of freedom of the target structure increases. However, considering a relatively large number of ground motions, uncertainty appeared insignificant regardless of increased degrees of freedom. Finally, it is possible that the increase in the number of ground motions could lower the epistemic uncertainty and thus improve the reliability of the results.
        4,000원
        2.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        일반적으로 속도 펄스를 가진 지반운동이 속도 펄스가 없는 지반운동에 비하여 구조물에 보다 큰 손상을 줄 수 있다고 알려져 있다. 지진가속도기록으로부터 속도 펄스의 유무의 판정과 이를 정량화하는 연구가 현재 많이 진행되어 오고 있다. 기존 지진기록들을 단 층으로 떨어진 거리를 기준으로 원거리 지진과 근거리 지진으로 구분하였다. 또한, 근거리 지진은 속도 펄스의 유무를 정량화하여 펄 스를 가진 지진과 펄스를 가지지 않은 지진으로 구분하였다. 최종적으로 각 지진그룹별로 40개의 원거리지진, 40개의 속도 펄스를 가 진 근거리 지진과 40개의 속도 펄스를 가지지 않은 근거리 지진을 선정하였으며, 총 120개 지진가속도 기록을 지진취약도 평가를 위 한 지진해석에 사용하였다. 세 그룹의 지진을 이용하여 납-고무받침과 탄성받침을 가진 두 종류의 예제교량에 대한 지진응답을 평가 하여 확률론적 지진요구도 모델을 작성하였다. 확률론적 지진요구도 모델을 이용하여 지진취약도 해석을 수행하여 속도 펄스의 유무 에 따른 지진취약도 영향을 분석하였다. 지진파의 속도 펄스 유무에 따른 지진취약도 곡선의 비교 결과로부터, 속도 펄스를 가진 지진 의 지진취약도가 속도 펄스가 없는 지진의 지진취약도가 약 3배~5배 정도 정도 크게 나타난다. 이는 속도 펄스를 가진 지진의 경우가 그렇지 않은 지진의 경우에 비하여 교량의 손상 피해가 크다는 것을 의미한다.
        4,500원
        3.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진취약도를 산정하기 위해서는 목표 부지의 특성을 제대로 표현할 수 있는 입력 지진파의 산정이 중요하다. 본 논문에서는 국내 외 강진 및 중‧약진 지역에서의 입력 지진파에 대한 단자유도 모델의 지진취약도를 분석하였다. 분석을 위한 첫 번째 단계로, 국외 강 진 기록 중 근/원거리에서 측정한 2개의 입력 지진파 세트와 국내 중·약진 지역 특성에 적합한 입력 지진파 2개의 세트, 총 4개의 입력 지진파 세트를 선정하였다. 대상 구조물로는 3가지 고유주기에 대한 비선형 단자유도 모델을 적용하였고, 취약도 분석을 위해 증분동 적해석을 이용하였다. 또한, 4가지 손상 상태를 정의하고, 손상 상태 각각에 대해 4가지 입력 지진파 세트의 고유주기별 지진취약도 결과를 제시하였다.
        4,000원
        4.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structures of high-rise buildings are less prone to earthquake damage. This is because the response acceleration of high-rise buildings appears to be small by generally occurring short-period ground motions. However, due to the increased construction volume of high-rise buildings and concerns about large earthquakes, long-period ground motions have begun to be recognized as a risk factor for high-rise buildings. Ground motion observed on each floor of the building is affected by the eigenmode of the building because the ground motion input to the building is amplified in the frequency range corresponding to the building's natural frequency. In addition, long-period components of ground motion are more easily transmitted to the floor or attached components of the building than short-period components. As such, high-rise buildings and non-structural components pose concerns about long-period ground motion. However, the criteria (ASCE 7-22) underestimate the acceleration response of buildings and non-structural components caused by long-period ground motion. Therefore, the characteristics of buildings’ acceleration response amplification ratio and non-structural components were reviewed in this study through shake table tests considering long-period ground motions.
        4,300원
        5.
        2021.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        According to several seismic design standards, a ground motion time history should be selected similar to the design response spectrum, or a ground motion time history should be modified by matching procedure to the design response spectrum through the time-domain method. For the response spectrum matching procedure, appropriate seed ground motions need to be selected to maintain recorded earthquake accelerogram characteristics. However, there are no specific criteria for selecting the seed ground motions for applying this methodology. In this study, the characteristics of ground motion time histories between seed motions and spectral matched motions were compared. Intensity measures used in the design were compared, and their change by spectral matching procedure was quantified. In addition, the seed ground motion sets were determined according to the response spectrum shape, and these sets analyzed the response of nonlinear and equivalent linear single degrees of freedom systems to present the seed motion selection conditions for spectral matching. As a result, several considerations for applying the time domain spectral matching method were presented.
        4,000원
        6.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, some of the most destructive earthquakes have occurred in South Korea since earthquake observations began in 1978. In particular, the soil liquefactions have been reported in Pohang as a result of the ML 5.4 earthquake that occurred in November 2017. Liquefaction-induced ground deformations can cause significant damage to a wide range of buildings and infrastructures. Therefore, it is necessary to take practical steps to ensure safety during an earthquake. In the current seismic design in South Korea, the Hachinohe earthquake and Ofunato earthquake recorded in Japan, along with artificial earthquakes, have been generally used for input motions in dynamic analyses. However, such strong ground motions are only from Japan, and artificial earthquake ground motions are different from real ground motions. In this study, seven ground motions are selected, including those recorded in South Korea, while others are compatible to the current design spectra of South Korea. The effects of the newly selected ground motions on site response analyses and liquefaction analyses are evaluated.
        4,000원
        7.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        액체저장탱크의 지진 거동은 유체-구조물 상호작용에 의해 복잡하게 나타나므로, 이 시스템의 지진응답과 피해를 정확하게 예측 하기 위해서는 이를 엄밀히 고려하여야 한다. 이 연구에서는 유체-구조물 상호작용을 엄밀히 고려하여 양방향 수평 지반운동이 작용 하는 직사각형 액체저장탱크의 지진응답 해석을 수행하고 그 응답 특성을 분석하고자 한다. 이를 위해 지진하중 작용 시 발생하는 유체 동수압을 유한요소 기법을 사용하여 산정하고, 이 동수압을 구조물의 유한 요소에 작용하여 전체 시스템의 동적 거동을 모사한다. 예제 직사각형 액체저장탱크의 지진응답 해석을 통하여 대상 시스템의 동적 거동은 양방향 수평 지반운동이 작용하는 방위각에 의해 유의미한 영향을 받음을 확인할 수 있다. 그러므로 직사각형 액체저장탱크의 내진설계를 수행하거나 내진성능을 검토할 때는 이러한 특성을 고려하여야 할 것이다.
        4,000원
        8.
        2019.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The tendency to use a probabilistic design method rather than a deterministic design method for the design of nuclear power plants (NPPs) will increase because their safety should be considered and strictly controlled in relation to various causes of damage. The distance between a seismically isolated NPP structure and a moat wall is called the clearance to stop. The clearance to stop is obtained from the 90th percentile displacement response of a seismically isolated NPP subject to a beyond design basis earthquake (BDBE) in the probabilistic design method. The purpose of this study is to analyze the effects of heating and buckling effects on the 90th percentile displacement response of a lead-rubber bearing (LRB) subject to a BDBE. The analysis results show that considering the heating and buckling effects to estimate the clearance to stop is conservative in the evaluation of the 90th percentile displacement response. If these two effects are not taken into account in the calculation of the clearance to stop, the underestimation of the clearance to stop causes unexpected damage because of an increase in the collision probability between the moat wall and the seismically isolated NPP.
        4,200원
        9.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a seismic design, a structural demand by an earthquake load is determined by design response spectra. The ground motion is a three-dimensional movement; therefore, the design response spectra in each direction need to be assigned. However, in most design codes, an identical design response spectrum is used in two horizontal directions. Unlike these design criteria, a realistic seismic input motion should be applied for a seismic evaluation of structures. In this study, the definition of horizontal spectral acceleration representing the two-horizontal spectral acceleration is reviewed. Based on these methodologies, the horizontal responses of observed ground motions are calculated. The data used in the analysis are recorded accelerograms at the stations near the epicenters of recent earthquakes which are the 2007 Odeasan earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Geometric mean-based horizontal response spectra and maximum directional response spectrum are evaluated and their differences are compared over the period range. Statistical representation of the relations between geometric mean and maximum directional spectral acceleration for horizontal direction and spectral acceleration for vertical direction are also evaluated. Finally, discussions and suggestions to consider these different two horizontal directional spectral accelerations in the seismic performance evaluation are presented.
        4,000원
        10.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wireless sensors are more favorable in measuring structural response compared to conventional sensors in terms of them being easier to use with no issues with cables and them being considerably cheaper. Previous tests have been conducted to analyze the performance of MEMS (Micro Electro Mechanical Systems) sensor in sinusoidal excitation tests. This paper analyzes the performance of in-built MEMS sensors in devices by comparing with an ICP sensor as the reference. Earthquake input amplitude excitation in shaking table tests was done. Results show that MEMS sensors are more accurate in measuring higher input amplitude measurements which range from 100gal to 250gal than at lower input amplitudes which range from 10gal to 50gal. This confirms the results obtained in previous sinusoidal tests. It was also seen that natural frequency results have lower error values which range from 0% to 3.92% in comparison to the response spectra results. This also confirms that in-built MEMS sensors in mobile devices are good at estimating natural frequency of structures. In addition, it was also seen that earthquake input amplitudes with more frequency contents (Gyeongju) had considerably higher error values than Pohang excitation tests which has less frequency contents.
        4,000원
        11.
        2019.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the effects of the significant duration of ground motions on responses of base-isolated nuclear power plants (NPPs). Two sets of ground motion records with short duration (SD) and long duration (LD) motions, scaled to match the target response spectrum, are used to perform time-history analyses. The reactor containment building in the Advanced Power Reactor 1400 (APR1400) NPP is numerically modeled using lumped-mass stick elements in SAP2000. Seismic responses of the base-isolated NPP are monitored in forms of lateral displacements, shear forces, floor response spectra of the containment building, and hysteretic energy of the lead rubber bearing (LRB). Fragility curves for different limit states, which are defined based on the shear deformation of the base isolator, are developed. The numerical results reveal that the average seismic responses of base-isolated NPP under SD and LD motion sets were shown to be mostly identical. For PGA larger than 0.4g, the mean deformation of LRB for LD motions was bigger than that for SD ones due to a higher hysteretic energy of LRB produced in LD shakings. Under LD motions, median parameters of fragility functions for three limit states were reduced by 12% to 15% compared to that due to SD motions. This clearly indicates that it is important to select ground motions with both SD and LD proportionally in the seismic evaluation of NPP structures.
        4,000원
        12.
        2018.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The site coefficients in the common requirements for seismic design codes, which were promulgated in 2017, were reevaluated and the standard design spectrum for soil sites were newly proposed in order to ensure the consistency of the standard design spectra for rock and soil sites specified in the common requirements. Using the 55 ground motions from domestic and overseas intraplate earthquakes, which were used to derive the standard design spectrum for rock sites, as rock outcropping motions, site response analyses of Korean soil were performed and its ground-motion-amplification was characterized. Then, the site coefficients for soil sites were reevaluated. Compared with the existing site coefficients, the newly proposed short-period site coefficient Fa increased and the long-period site coefficient Fv decreased overall. A new standard design spectrum for soil sites was proposed using the reevaluated site coefficients. When compared with the existing design spectrum, it could be seen that the proposed site coefficients and the standard design spectrum for soil sites were reasonably derived. They reflected the short-period characteristics of earthquake and soil in Korea.
        4,000원
        13.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In low to moderate seismic regions, there are limited earthquake ground motion data recorded from past earthquakes. In this regard, th e Gyeongju earthquake (M=5.8)occurred on September 12, 2016 produces valuable information on ground motions. Ground motions w ere recorded at various recording stations located widely in Korean peninsula. Without actual recoded ground motions, it is impossible t o make a ground motion prediction model. In this study, a point source model is constructed to accurately simulate ground motions rec orded at different stations located on different soil conditions during the Gyeongju earthquake. Using the model, ground motions are ge nerated at all grid locations of Korean peninsula. Each grid size has 0.1°(latitude)x0.1°(longitude). Then a contour hazard map is constr ucted using the peak ground acceleration of the simulated ground motions
        4,000원
        14.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Korean peninsula has known as a minor-to-moderate seismic region. However, some recent studies had shown that the maximum possible earthquake magnitude in the region is approximately 6.3-6.5. Therefore, a seismic vulnerability assessment of the existing infrastructures considering ground motions in Korea is necessary. In this study, we developed seismic fragility curves for a continuous steel box girder bridge and two typical transmission towers, in which a set of seven artificial and natural ground motions recorded in South Korea is used. A finite element simulation framework, OpenSees, is utilized to perform nonlinear time history analyses of the bridge and a commercial software, SAP2000, is used to perform time history analyses of the transmission towers. The fragility curves based on Korean ground motions were then compared with the fragility curves generated using worldwide ground motions to evaluate the effect of the two ground motion groups on the seismic fragility curves of the structures. The results show that both non-isolated and base-isolated bridges are less vulnerable to the Korean ground motions than to worldwide earthquakes. Similarly to the bridge case, the transmission towers are safer during Korean motions than that under worldwide earthquakes in terms of fragility functions.
        4,000원
        15.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently, researches are being actively conducted in assessing seismic performance of nuclear facilities in USA and Europe. In particular, applying this technique of assessing seismic performance to design of isolation systems in nuclear power plants is being performed and then ASCE 4 Draft (2013) is being revised accordingly in the United States. In order to satisfy the probabilistic performance objectives described by seismic responses with certain confidence levels (ASCE 43, 2005), the probability distributions of these responses have to be defined. What is the minimum number of input ground-motions to obtain the probability distribution precise enough to represent the unknown actual distribution? Theoretical basis, for how to determine the minimum number of input ground-motions for given a logarithmic standard deviation to approximate the unknown actual median of the log-normal distribution within a range of error at a certain level of confidence, is introduced by Huang et al. (2008). However, the relationship between the level of confidence and the range of error is not stated in the previous study. In this paper, based on careful reviews on the previous work, the relationship between the level of confidence and the range of error is logically and explicitly stated. Furthermore, this relationship is also applied to derive the minimum number of input ground-motions in order to approximate the unknown actual logarithmic standard deviation. Several recommendations are made for determining the minimum number of input ground-motions in probabilistic assessment on seismic performance of facilities in nuclear power plants.
        4,000원
        16.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is important to select proper ground motions for obtaining accurate results from response history analyses. The purpose of this study is to propose an accurate and efficient method that does not require excessive computation for selecting and scaling ground motions to match target response spectrum mean and variance. The proposed method is conceptually simple and straightforward, and it does not use a simulation algorithm that requires a sophisticated subroutine program. In this method, the desired number of ground motions are sequentially scaled and selected from a ground motion library. The proposed method gives the best selection results using Sum of Square Error and has the smallest value(=0.14). Also, The accuracy and consistency of the proposed method are verified by comparing the selection results of the proposed method with those of existing methods.
        4,000원
        17.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동조액체감쇠기(TLD)는 에너지 소산장치로써 구조물의 동적응답을 제어하기 위해 개발되었다. TLD는 풍하중에 의한 구조물의 응답을 제어에 매우 효과적임을 보여줬다. 그러나 TLD가 설치된 구조물의 지진응답의 제어에 대해서는 충분한 연구가 이뤄지지 않았다. 이 연구의 목적은 TLD가 설치된 구조물에 여러 동조비와 질량비를 대입하여 지진에 대한 TLD의 성능을 도출하는 것이다. 이러한 목적을 위해, 수치해석 연구가 실시되며, 다른 토양 조건 또한 고려되었다. 그 결과 지진하중에 대한 TLD의 성능은 구조물의 고유주기, 감쇠비에 따라 다르게 나타났다. 또한 TLD의 동조비 다르게 나타남을 알 수 있었다.
        4,000원
        18.
        2016.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is the sequel of a companion paper (I. Algorithm) for assessment of the seismic performance evaluation of structure using ground motions selected by the proposed algorithm. To evaluate the effect of the correlation structures of selected ground motions on the seismic responses of a structure, three sets of ground motions are selected with and without consideration of the correlation structure. Nonlinear response history analyses of a 20-story reinforced concrete frame are conducted using the three sets of ground motions. This study shows that the seismic responses of the frames vary according to ground motion selection and correlation structures.
        4,000원
        19.
        2016.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is important to select an accurate set of ground motions when conducting linear and nonlinear response history analyses of structures. This study proposes a method for selecting ground motions from a ground motion library with response spectra that match the target response spectrum mean, variance and correlation structures. This study also has addressed the determination of an appropriate value for the weight factor of a correlation structure. The proposed method is conceptually simple and straightforward, and does not involve a simulation algorithm. In this method, a desired number of ground motions are sequentially selected from first to last. The proposed method can be also used for selecting ground motions with response spectra that match the conditional spectrum. The accuracy and efficiency of the proposed procedure are verified with numerical examples.
        4,000원
        20.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper briefly introduces the design seismic loads in Korea (KBC 2009). Then, over 10,000 recorded earthquake ground accelerograms, with their magnitude ranging from 4.0 to 8.0 and their epicentral distance ranging from 0 to 200 km, were used to examine the appropriateness of seismic load defined in Korea known as a low-to-moderate seismicity region. The following conclusions are drawn based on the results: (1) The effective peak ground accelerations (EPA) of recorded earthquake accelerograms under M ≤ 6.0 and R ≥15 km appear to be less than that of MCE in Korea for all site conditions defined in KBC 2009. (2) The design spectrum (two-thirds of the intensity of MCE) in KBC 2009 is comparable to those of earthquake records in the magnitude 6 - 7 and the epicentral distance less than 50 km. Therefore, (3) the intensity of Korean design earthquake is considered to be overly high since the Korea peninsula is generally conceived to be a low-seismicity region.
        4,000원
        1 2