검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 18

        1.
        2017.04 구독 인증기관·개인회원 무료
        In this study, finite element analysis of korean precast concrete panels was performed and 3D infinite element modeling was used. Infinite elements can be formulated in time domain and nonlinear behavior analysis is possible. Based on the numerical results, the performance of the packing layer of korean precast concrete panels was examined.
        2.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the response characteristics and performance of a biofilter in the removal of ammonia, as a malodor compound. A trickle-bed type biofilter was applied for this study, and operated at the ammonia loading rate of 0.97-15.52 g/m3·h. The results of the experiment indicate that the critical loading rate of ammonia to the biofilter was 10.7 g/m3·h and the elimination capacity was 11.6 g/m3·h. The analysis of nitrogen mass balance in the reactor indicates that inlet nitrogen as gas phase was converted through the biofilter into NH4 + (41.5% by mass), NO2 - (43%), and NO3 - (15%) as the available form of nitrogen in the effluent liquid. Free ammonia concentration in the effluent liquid was estimated as being in the range from 0.14 to 2.93 mg/L (average 1.7 mg/L) during the experimental period.
        4,000원
        3.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out in order to evaluate the design suitability of gas scrubbers, which have been operated in Siheung and Ansan Smarthubs, as an odor removal device. Detailed design data of 31 gas scrubbers installed between 2005 to 2014 were investigated. All the scrubbers investigated were found to use a “packed bed” design, and 30 of them used pall rings as packing materials. In determining the bed diameter of scrubbers, many facilities used incorrect packing parameters, which resulted in inappropriate design values for the bed diameter. In determining of the height of packed bed, the height of transfer unit (HTU) was calculated incorrectly because of the misuse of both the constants of packing materials and Schmidt numbers. In addition, the values of number of transfer unit (NTU) were found to be underestimated due to the low removal efficiency goal. Therefore, the adapted values of packed bed height were quite different from the ones calculated in many facilities.
        4,000원
        4.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Freezing of the pure water saturating a packed bed of spheres in a rectangular cavity is performed experimentally to investigate the effect of bead diameter on the heat transfer rate and temperature vs. time history for the pure water freezing experiments were compared with the freezing of the binary solution(HO-NaCl). Spherical soda-lime glass beads of 2.85mm and 6mm in average diameter constitute the porous medium. The system is cooled through its bottom surface, and the top is maintained at a temperature above the liquids. There was small effect on the temperature distribution in the system of the porosity difference.
        4,000원
        5.
        2001.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The characteristics of adsorption and desorption of benzene and toluene were investigated at a fixed bed packed with the activated carbon and activated carbon fiber. Through breakthrough experiments under various feed concentration conditions, it was found that the slope of mass transfer zone and the tailing in the breakthrough curves were different from the feed conditions due to different heats of adsorption. In hot nitrogen desorption, the regeneration time and mass transfer zone of the toluene desorption curve were longer than those of the benzene desorption curve because of the difference in adsorption affinity. With an increase in the regeneration temperature, the height of roll-up and the sharpness of desorption curves increased but the regeneration times decreased. The adsorption capacities of the activated carbon and activated carbon fiber after three-time thermal regenerations decreased about 25% and 37% for benzene and 18% and 25% for toluene, respectively. To investigate the effect of the regeneration temperature on the energetic efficiency, the characteristic desorption temperatures of toluene and benzene were investigated by calculating purge gas consumption and temperature.
        4,200원
        7.
        2017.05 서비스 종료(열람 제한)
        국내 광공업 중 자동차 제조업, 금속가공제품 제조업 등 금속가공을 필요로 하는 사업체는 전체 광공업 사업체 163,822개 중 40%를 차지하고 있다. 산업혁명 이래 기계 산업은 빠르게 발전해왔으며 기계 산업이 발달한 현대사회에서 금속 가공 공정은 필수적이다. 이러한 금속 가공 과정에서 금속과 금속사이의 마찰을 줄이기 위한 윤활작용, 마찰로 인한 열팽창 및 변형을 막기 위한 냉각작용, 부식 방지를 위한 방청제 역할을 하는 것이 절삭유이다. 절삭유는 일반적으로 수용성과 비수용성으로 분류되며, 비수용성의 경우 작업 중 및 작업 후 발생하는 오일미스트로 인한 유독성 및 발화 위험 등의 문제가 제기됨에 따라 수용성 절삭유의 사용이 점차 증가하여, 국내 절삭유 사용량의 60% 이상을 수용성 절삭유가 차지하고 있다. 하지만 수용성 절삭유에는 아질산염, 방부제 등 20~30개의 화학물질이 포함되어 있다. 또한, 수용성 절삭유에 함유되어있는 질소계 물질들은 수생태계에 방류되면 부영양화 및 녹조 현상과 같은 문제를 일으킬 수 있으며, 수중에서 산화반응을 하여 아질산성 질소와 질산성 질소로 변화되면서 수계의 용존산소를 감소시켜 오염을 일으킬 수 있어 각별한 처리가 필요한 실정이다. 따라서 본 연구에서는 입상활성탄(Granular activated carbon)을 충진한 충진복극조를 이용해 전기화학적 처리를 통해 수용성 절삭유의 T-N 제거율을 분석하였다. 실험조건은 다음의 Table 1, 실험장치의 구성을 Fig. 1에 간단히 나타내었다.
        9.
        2016.04 KCI 등재 서비스 종료(열람 제한)
        In this study, GC-MS linked with an automatic thermal desorber was used to quantitatively analyze the odorous and volatile compounds in the gas emitted from a sewage sludge drying facility. In addition, the removal characteristics of these compounds were investigated by using a pilot-scale packed bed wet scrubber. A quantitative analysis for 58 odorous and volatile compounds in the gas was successfully achieved with GC-MS and GC-FPD. The a quantitative analysis revealed the major odorous compounds were hydrogen sulfide and acetaldehyde. In addition, D-type siloxane compounds such as octamethylcyclotetrasiloxane (D4), decamethylcyclopentasiloxane (D5), and dodecamethylcyclohexasiloxane (D6), were quantitatively measured. The concentrations of siloxane compounds measured in the gas were in the range of 4.54- 7.36 ppmv, higher than those in landfill gas. The average removal efficiency of the odorous and volatile compounds in a wet scrubber was 67.37%. D4, D5, and D6, which are hydrophobic compounds, were also removed by as much as 50.68%, 44.56%, and 70.26%, respectively.
        10.
        2015.05 서비스 종료(열람 제한)
        This study of the electrolysis reaction fillers and electrolytic treatment sludge generated by checking the status and properties of the sludge before and after electrolysis filler caused by a reaction to examine the water-soluble cutting oil sludge and organic matter removal mechanism of filling in the packed bed bipolar electrolytic reactor was to identify the characteristics. Delivery was analyzed using a SEM (scanning electron microscope) recording method for the filling material in the GAC surface characterization of the packed bed bipolar electrolytic reactor to look at the reaction of the waste water generated by the electrolytic removal reaction. Sludge generated in order to analyze the properties of XRD(x-ray diffraction) was analyzed using the device. The video of the GAC surface before and after the reaction was taken by SEM, it can be known indirectly the change between the voids in the GAC in figure before and after. Prior to the electrolytic treatment can be seen that there is some contamination between the pores, but it can be seen that after the treatment, rather than clean the pores of the GAC. This photograph of the surface after the electrolytic treatment, GAC is decomposed organic material adsorbed on the surface by dissolution of ions at the anode acting on bipolar electrolytic, it is corroded, it is possible to observe what happens. It was found to form iron oxide when analyzing the electrolytic sludge using XRD. Properties of the sludge generated after electrolysis, was composed primarily of oxygen and iron. These results wastewater treatment by filling in the electrolytic cell is that it indirectly proves to occur by electrolysis removal, it is considered to be able to demonstrate the deletion mechanism indirectly.
        11.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        The aim of this paper is to compare the characteristics of the T-P removal from synthesized municipal wastewater by electro-coagulation using cylindrical Al and Fe electrode as anode. For this purpose, a concentric circle type electrolysis reactor was used and the operating conditions for T-P removal from synthesized wastewater are as follows; potential 10 V, electrolyte 0.03% NaCl, initial T-P concentration 1.0 ~ 6.0 mg/L and flow rate 1.0 ~ 5.0 L/min. From the experimental results, T-P concentration of treated wastewater was decreased to less than 0.2 mg/L enough to discharge standard and Al electrode showed performance than Fe electrode for T-P removal by electro-coagulation. Optimal conditions for T-P removal to less than 0.15 mg/L which is 75% of discharge standard for large scale municipal wastewater plant (capacity higher than 500 m3/day) were obtained as follows; flow rate 2.503 L/min, and 2.337 L/min, HRT 1.059 min, 1.134 min, for Al and Fe electrode, respectively. Consumed mass of Al and Fe were of 3.76 times and 8.90 times respectively, were obtained to removed T-P at optimal conditions with potential 10 V, and 0.03% NaCl as electrolyte.
        12.
        2014.06 KCI 등재 서비스 종료(열람 제한)
        The adsorption experiments of lithium ions were conducted in the fixed bed column packed with activated carbon modified with nitric acid. Effect of inlet concentration, bed hight and flow rate on the removal of lithium ions was investigated. The experimental results showed that the removal and the adsorption capacity of lithium ions increased with increasing inlet concentration, and decreased with increasing flow rate. When the bed height increased, the removal and the adsorption capacity increased. The breakthrough curves gave a good fit to Bohart-Adams model. Adsorption capacity and breakthrough time calculated from Bohart-Adams model, these results were remarkably consistent with the experimental values. The adsorption capacity was not changed in the case of 3 times repetitive use of adsorbent.
        13.
        2014.01 KCI 등재 서비스 종료(열람 제한)
        Adsorption of phenol on activated carbon in a fixed bed was studied. The effects of fixed-bed length, superficial velocity (flow rate) and particle size of adsorbent on fixed-bed performance were investigated. Some characteristic parameters such as the breakthrough time (t0.05), saturation time (t0.95), length of mass transfer zone (LMTZ), adsorptive capacity (W), and adsorption rate constant (Ka) were derived from the breakthrough curves. Adsorbent particle sizes significantly affected the shape of the breakthrough curve. Larger particle sizes resulted in an earlier breakthrough, a longer LMTZ and a lower adsorption rate. Superficial velocity was a critical factor for the external mass transfer during fixed-bed adsorption process. The external mass transfer resistance was dominant as increasing superficial velocity.
        14.
        2007.03 KCI 등재 서비스 종료(열람 제한)
        The photocatalytic decolorization of Rhodamine B (RhB) was studied using packed-bed reactor and immobilized TiO2/UV System. The 20 W UV-A, UV-B and UV-C lamps were employed as the light source. The effect of shape and surface polishing extent of reflector, distance between the reactor and reflector, reactor material were investigated. The results showed that the order of the initial reaction constant with reflector shape was round > polygon > W > rhombus. The optimum distance between the reactor and reflector was 2 cm. The initial reaction constant of quartz reactor was 1.46 times higher than that of the PVDF reactor.
        15.
        2002.12 KCI 등재 서비스 종료(열람 제한)
        This study was focused on the investigation of the characteristics of organics and nitrogen removal with the recycle ratio in anoxic/oxic(A/O) packed bed process that consisted of the anoxic reactor and the aerobic reactor. As increasing the recycle ratio by 0.5, 1.0, 2.0, the COD removal efficiency increased by 94.0%, 98.5%, 98.8% respectively. The aerobic reactor showed the perfect nitrification efficiency by 98.5%, 99.2%, 98.0% respectively. The T-N removal efficiency with the recycle ratio, increased by 56%, 67%, 70% respectively. As increasing the recycle ratio by 0.5, 1.0, 2.0, T-P removal efficiency decreased by 62.1%, 57.4%, 51.3% respectively. The process by releasing the stored phosphorus in the anoxic reactor and uptaking the excess phosphorus in the aerobic reactor, occurred well comparatively when recycle ratio is 0.5. But this process did not occur when the recycle ratio is 1.0 and 2.0. And optimum pH of nitrification was about 6~7 and alkalinity decreased as nitrification rate increased. As increasing the recycle ratio in the anoxic reactor, DO concentration and ORP increased.
        16.
        2002.04 KCI 등재 서비스 종료(열람 제한)
        This study was to analyze the right or wrong of gray-water treatment by applying BPBE electrode cell to the effluence water in the terminal disposal plant of sewage. The results were as follows : The best result was obtained with applied voltage 40V and detention time 6 minutes for the BPBE electrode cell which has the graphite-plate in main electro-de, packing coconut activated carbon. The elimination rate of COD of Al-plate was higher than that of graphite-plate in main electrode. The result of electrolysis for 3 hour in parallel circuit showed the using possibility of gray-water according to each elimination rate : COD 59%, T-N 69 %, T-P 69%. The BPBE electrode cell with the Al-plate in main electrode made the best effect for the elimination of algae in lake water and algae were not occurred in electrolytic water
        17.
        1999.08 KCI 등재 서비스 종료(열람 제한)
        This study was conducted to evaluate capability of dyeing wastewater treatment for 3 type reactors. These reactors were Packed Bed Reactor(PBR), Fluidized Bed reactor(FBR) and Moving Media Complete Mixing Activated Sludge reactor(MMCMAS). Experiments of PBR and FBR were performed by various packing ratios and organic loading rates, experiments of MMCMAS were performed by various organic loading rates In order to obtain SBOD_5 removal efficiencies of more than 90%, the F/Mv ratios of PBR, FBR, MMCMAS were 0.11 ㎏BOD/㎏MLVSS·d, 0.12 ㎏BOD/㎏MLVSS·d, and 0.37 ㎏BOD/㎏MLVSS·d, respectively. So MMCMAS system which has more active microorganisms showed better capability of organic removal and also stronger dynamic and shock loadings than those of PBR and FBR. In PBR and FBR, the media packing ratio of 20% showed better performance of organic matters removal effciencies than 10% and 30%, but sludge production rate at media packing ratio of 30% was relatively lower than that of 10% and 20%. When more than 90% organic matters removal efficiency was obtained, the ratios of attached biomass to total biomass at PBR, FBR, MMCMAS were 89∼99%, 87∼98%, and 54∼80%, respectvely. The ratio of attached biomass to total biomass was low in MMCMAS. This was formation of thin biofilm due to shear force between rotating disc and water. The average sludge production rates(㎏VSS/㎏BODrem.) of PBR, FBR and MMCMAS were 0.20, 0.29 and 0.54, respectively.
        18.
        1999.04 KCI 등재 서비스 종료(열람 제한)
        Nitrifier consortium entrapped in Ca-alginate bead were packed into aerated packed bed bioreactor and non aerated packed bed bioreactor and the performances of two bioreactors were evaluated for the removal of ammonia nitrogen from synthetic aquaculture water. Total ammonia nitrogen(TAN) removal rate was decrease in aerated packed bed bioreactor below 0.3hr of hydraulic residence time(HRT), but increased in non aerated packed bed bioreactor until 0.5hr of HRT. At HRT of 0.05 hr, TAN removal rate of non aerated packed bed bioreactor was about 335g TAN/㎥/day and the optimum ratio of packing height and inside diameter of reactor (H/D) was 4. The performance of two bioreactors indicated that non aerated packed bed bioreactor was better than aerated packed bed bioreactor in ammonia removal from synthetic aquaculture water.