The damage to structures during an earthquake can be varied depending on the frequency characteristics of seismic waves and the geological properties of the ground. Therefore, considering such attributes in the design ground motions is crucial. The Korean seismic design standard (KDS 17 10 00) provides design response spectra for various ground classifications. If required for time-domain analysis, ground motion time series can be either selected and adjusted from motions recorded at rock sites in intraplate regions or artificially synthesized. Ground motion time series at soil sites should be obtained from site response analysis. However, in practice, selecting suitable ground motion records is challenging due to the overall lack of large earthquakes in intraplate regions, and artificially synthesized time series often leads to unrealistic responses of structures. As an alternative approach, this study provides a case study of generating ground motion time series based on the hybrid broadband ground motion simulation of selected scenario earthquakes at sites in the Nakdonggang delta region. This research is significant as it provides a novel method for generating ground motion time series that can be used in seismic design and response analysis. For large-magnitude earthquake scenarios close to the epicenter, the simulated response spectra surpassed the 1000-year design response spectra in some specific frequency ranges. Subsequently, the acceleration time series at each location were used as input motions to perform nonlinear 1D site response analysis through the PySeismoSoil Package to account for the site response characteristics at each location. The results of the study revealed a tendency to amplify ground motion in the mid to long-period range in most places within the study area. Additionally, significant amplification in the short-period range was observed in some locations characterized by a thin soil layer and relatively high shear wave velocity soil near the upper bedrock.
Existing reinforced concrete (RC) frame buildings have seismic vulnerabilities because of seismically deficient details. In particular, since cumulative damage caused by successive earthquakes causes serious damage, repair/retrofit rehabilitation studies for successive earthquakes are needed. This study investigates the repair effect of fiber-reinforced polymer jacketing system for the seismically-vulnerable building structures under successive earthquakes. The repair modeling method developed and validated from the previous study was implemented to the building models. Additionally, the main parameters of the FRP jacketing system were selected as the number of FRP layers associated with the confinement effects and the installation location. To define the repair effects of the FRP jacketing system with the main parameters, this study conducted nonlinear time-history analyses for the building structural models with the various repairing scenarios. Based on this investigation, the repair effects of the damaged building structures were significantly affected by the damage levels induced from the mainshocks regardless of the retrofit scenarios.
Nuclear power plants in Korea were designed and evaluated based on the NRC's Regulatory Guide 1.60, a design response spectrum for nuclear power plants. However, it can be seen that the seismic motion characteristics are different when analyzing the Gyeongju earthquake and the Pohang earthquake that has recently occurred in Korea. Compared to the design response spectrum, seismic motion characteristics in Korea have a larger spectral acceleration in the high-frequency region. Therefore, in the case of equipment with a high natural frequency installed in a nuclear power plant, seismic performance may be reduced by reflecting the characteristics of domestic seismic motions. The failure modes of the equipment are typically structural failure and functional failure, with an anchorage failure being a representative type of structural failure. In this study, comparative analyses were performed to decide whether to consider the inelastic behavior of the anchorage or not. As a result, it was confirmed that the seismic performance of the anchorages could be increased by considering the inelastic behavior of an anchorage.
Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.
본 연구의 목적은 원자로 1400(APR 1400) 원자력 발전소(NPP)의 원자로 격납건물(RCB) 내진성능에 대해 상이한 수치모델과 지진 주파수 성분의 영향을 평가하는 것이다. 집중 질량 막대 모델(lumped-mass stick model, LMSM)과 3차원 유한요소모델(threedimensional finite element model, 3D FEM)의 두 가지 수치 모델이 시간이력해석을 수행하기 위해 개발되었다. LMSM은 기존의 집중 질량 보-요소를 사용하여 SAP2000으로 구성하였으며, 3D FEM은 각기둥 입체-요소를 사용하여 ANSYS로 작성되었다. 저주파수 및 고주파수 성분을 고려한 두 그룹의 지진파를 시간이력해석에 적용하였다. 저주파수 지진파의 응답스펙트럼을 NRC 1.60의 설계 스펙트럼과 일치되도록 조정하여 작성하였으며, 고주파수 지진파는 10Hz ~ 100Hz의 고주파수 범위를 갖도록 생성하였다. RCB의 지진응 답은 다양한 높이에서 층응답스펙트럼으로 검토하였다. 수치해석 결과, 저주파수 지진에 의한 구조물의 FRS 결과는 두 수치 모델에 서 매우 유사한 결과를 보였다. 하지만, 고주파수 지진에 의한 LMSM의 FRS 결과는 고차 고유 주파수 영역에서 3D FEM과 큰 차이를 보였으며, RCB의 낮은 높이에서 명확한 차이를 보였다. 3D FEM이 정확한 구조물의 응답을 나타내는 것으로 가정한다면, RCB의 LMSM은 고주파수 지진에 의한 FRS 결과의 고차 고유 주파수 영역에서 일정 수준의 불일치성을 내포하고 있다.
In this study earthquake records were collected for rock conditions that do not reflect seismic amplification by soil from global earthquake databases such as PEER, USGS, and ESMD. The collected earthquake records were classified and analyzed based on the magnitude and distance of earthquakes. Based on the analyzed earthquakes, the design response spectrum shape, effective ground acceleration, and amplification ratios for each period band are presented. In addition, based on the analyzed data, the story shear force for 5F, 10F, 15F, and 20F were derived through an analysis of the elastic time history for multi-DOF structures. The results from analyzing the rock earthquake record show that the seismic load tends to be amplified greatly in the short period region, which is similar to results observed from the Gyeongju and Pohang earthquakes. In addition, the results of the multi-DOF structure analysis show that existing seismic design criteria can be underestimated and designed in the high-order mode of short- and medium-long cycle structures.
강한 지진의 영향에 있는 레디얼 게이트에 작용하는 동수압 산정을 위한 계산 모형이 제시되었다. 지진동으로 움직이는 구조물의 영향을 호소부와의 이동경계면으로 처리함과 아울러 강한 지진동 효과를 고려하여 동적 레이어링법이 적용된 ALE 알고리즘과 호소부 자유수면 거동을 위한 SIMPLE법을 사용하는 것이 제안된다. 제안된 방법은 단순한 수직 또는 경사 댐체 벽면에 대하여 널리 알려진 실험 결과 및 그로부터 유도된 제안식과 비교하여 타당성과 유효성이 증명되었다. 계산 모형에서 사용할 호소부 상류부 측의 무한경계까지의 거리를 산정하기 위한 파라미터 분석을 수행하여 호소부 수위의 2배가 최적의 길이임을 관찰하였다. 마지막으로 제안된 계산 모형을 사용하여 여러 곡률의 대형 레디얼 게이트에 작용하는 지진 동수압을 성공적으로 산출하였다.
In a seismic design, a structural demand by an earthquake load is determined by design response spectra. The ground motion is a three-dimensional movement; therefore, the design response spectra in each direction need to be assigned. However, in most design codes, an identical design response spectrum is used in two horizontal directions. Unlike these design criteria, a realistic seismic input motion should be applied for a seismic evaluation of structures. In this study, the definition of horizontal spectral acceleration representing the two-horizontal spectral acceleration is reviewed. Based on these methodologies, the horizontal responses of observed ground motions are calculated. The data used in the analysis are recorded accelerograms at the stations near the epicenters of recent earthquakes which are the 2007 Odeasan earthquake, 2016 Gyeongju earthquake, and 2017 Pohang earthquake. Geometric mean-based horizontal response spectra and maximum directional response spectrum are evaluated and their differences are compared over the period range. Statistical representation of the relations between geometric mean and maximum directional spectral acceleration for horizontal direction and spectral acceleration for vertical direction are also evaluated. Finally, discussions and suggestions to consider these different two horizontal directional spectral accelerations in the seismic performance evaluation are presented.
지진 관련 정책 입안과 수행에 우선적으로 고려되어야 할 정보가 지진 발생현황이지만, 대도시와 인구밀집 지역의 경우 높은 생활잡음으로 인해 작은 규모의 지진 발생을 정확히 인지하지 못하는 경우가 많다. 본 연구에서는 2010년부터 2017년까지 부산지역에서 발생했지만, 규모가 작아 기상청 지진목록에 수록되지 않은 미소 지진 10회를 파형의 유사성을 이용하여 검출하였고, 기존에 발생사실을 알고 있던 지진을 포함하여 총 12회의 지진을 분석에 사용하였다. 새로이 보고되는 지진은 선형을 보이면서 발생하고 있지만, 주변의 단층과 직접적으로 연관하여 해석하기에는 자료가 충분치 않다. 규모가 작은 미소 지진이 꾸준히 발생한다는 것은 지하에 지진을 일으키는 단층이 존재함을 시사하고, 부산과 같은 인구밀집 지역에서 과거 피해를 유발한 역사지진과 비슷한 규모의 지진이 발생한다면 대형 피해로 발전될 가능성이 매우 크다. 최근 우리나라에서 발생한 피해 유발 지진이 지표파열을 동반하지 않고 발생하고 있음을 고려할 때 현재 발생하고 있는 미소 지진 현황을 파악하여 지표 단층조사와 함께 지하단층을 규명하는데 활용하여야 한다.
In order to increase the seismic safety of nuclear power plant (NPP) structures, a technique to reduce the seismic load transmitted to the NPP structure by using a seismic isolation device such as a lead-rubber bearing has recently been actively researched. In seismic design of NPP structures, three directional (two horizontal and one vertical directions) artificial synthetic earthquakes (G0 group) corresponding to the standard design spectrum are generally used. In this study, seismic analysis was performed by using three directional artificial synthetic earthquakes (M0 group) corresponding to the maximum-minimum spectrum reflecting uncertainty of incident direction of earthquake load. The design basis earthquake (DBE) and the beyond design basis earthquakes (BDBEs are equal to 150%, 167%, and 200% DBE) of G0 and M0 earthquake groups were respectively generated for 30 sets and used for the seismic analysis. The purpose of this study is to compare seismic responses and seismic fragility curves of seismically isolated NPP structures subjected to DBE and BDBE. From the seismic fragility curves, the probability of failure of the seismic isolation system when the peak ground acceleration (PGA) is 0.5 g is about 5% for the M0 earthquake group and about 3% for the G0 earthquake group.
P파와 S파의 도착시간 정보는 지진 발생위치 결정, 1차원 및 3차원 지하구조 등 지진학 연구 수행에 중요한 정보이다. 최근 지진관측소의 수가 비약적으로 증가함에 따라 관측망을 운영하면서 수동으로 지진파의 도착시간을 측정하는 것은 상당한 시간이 소요되는 일이 되었다. 본 연구에서는 진원요소에 대한 사전정보(지진 발생위치와 시간)를 확보 할 수 있는 경우 Akaike Information Criterion (AIC)을 적용하여 추가의 관측소에서 국지지진의 P파와 S파의 도착시간을 자동측정하였다. 해당 방법을 경산(DAG2) 지진관측소에 기록된 자료에 적용한 후 수동 측정한 값과 자동 측정한 값을 비교한 결과 P파의 경우 95.1%, S파의 경우 93.7%가 0.1초 이하의 차이를 보이면서 결정되는 것을 확인하였다. 자동측정결과의 높은 정확성은 향후 고밀도 지진관측망 운영에 성공적으로 적용될 수 있음을 시사한다.
Recent two moderate earthquakes (2016 Mw=5.4 Gyeongju and 2017 Mw=5.5 Pohang) in Korea provided the unique chance of developing a set of relations to estimate instrumental seismic intensity in Korea by augmenting the time-history data from MMI seismic intensity regions above Ⅴ to the insufficient data previously accumulated from the MMI regions limited up to Ⅳ. The MMI intensity regions of Ⅴ and Ⅵ was identified by delineating the epicentral distance from the reference intensity statistics in distance derived by using the integrated MMI data obtained by combining the intensity survey results of KMA (Korea Meteorological Administration) and ‘DYFI (Did You Feel It)’ MMIs of USGS. The time-histories of the seismic stations from the MMI intensity regions above Ⅴ were then preprocessed by applying the previously developed site-correction filters to be converted to a site-equivalent condition in a manner consistent with the previous study. The average values of the ground-motion parameters for the three ground motion parameters of PGA, PGV and BSPGA (Bracketed Summation of PGA per second for 30 seconds) were calculated for the MMI=Ⅴ and Ⅵ and used to generate the dataset of the average values of the ground-motion parameters for the individual MMIs fromⅠ to Ⅵ. Based on this dataset, the linear regression analysis resulted in the following relations with proposed valid ranges of MMI.
In this paper, comparative analysis of the 9.12 Gyeongju and 11.15 Pohang earthquakes was conducted in order to provide probable explanations and reasons for the damage observed in the 11.15 Pohang earthquake from both earthquake and structural engineering perspectives. The damage potentials like Arias intensity, effective peak ground acceleration, etc observed in the 11.15 Pohang earthquake were generally weaker than those of the 9.12 Gyeongju earthquake. However, in contrast to the high-frequency dominant nature of the 9.12 Gyeongju earthquake records, the spectral power of PHA2 record observed in the soft soil site was highly concentrated around 2Hz. The base shear around 2 Hz frequency was as high as 40% building weight. This frequency band is very close to the fundamental frequency of the piloti-type buildings severely damaged in the northern part of Pohang. Unfortunately, in addition to inherent vertical irregularity, most of the damaged piloti-type buildings had plan irregularity as well and were non-seismic. All these contributed to the fatal damage. Inelastic dynamic analysis indicated that PHA2 record demands system ductility capacity of 3.5 for a structure with a fundamental period of 0.5 sec and yield base shear strength of 10% building weight. The system ductility level of 3.5 seems very difficult to be achievable in non-seismic brittle piloti-type buildings. The soil profile of the PHA2 site was inversely estimated based on deconvolution technique and trial-error procedure with utilizing available records measured at several rock sites during the 11.15 Pohang earthquake. The soil profile estimated was very typical of soil class D, implying significant soil amplification in the 11.15 Pohang earthquake. The 11.15 Pohang earthquake gave us the expensive lesson that near-collapse damage to irregular and brittle buildings is highly possible when soil is soft and epicenter is close, although the earthquake magnitude is just minor to moderate (M 5+).
This study experimentally and analytically examines the seismic vulnerability of steel rack storage frames subjected to Korea earthquakes (2016 Gyeongju earthquake and 2017 Pohang earthquake). To achieve this aim, this study selects a three-story, one-bay steel rack frame with a typical configuration of rack frame in Korea. Firstly, the local behavior for frame components is examined by performing monotonic and/or cyclic load tests and the global response and dynamic characteristics of the subject rack frame are investigated by conducting a shaking table test. The analytical model of the rack frame is then created based on the experimental results and is used to perform nonlinear time history analyses with recorded Korea earthquakes. The seismic demand of the rack frame is considerably affected by the spectral acceleration response, instead of peak ground accelerations (peak floor accelerations). Moreover, the collapse fragility curve of the rack frame is developed using incremental dynamic analyses for the Gyeongju and Pohang earthquakes. Fragility results indicate that the ground motion characteristics of these earthquakes do not significantly affect the frame vulnerability at the collapse state.
Severe earthquakes can cause damage to society both socially and economically. An appropriate initial response can alleviate damage from severe earthquakes. In order to formulate an appropriate initial response, it is necessary to identify damage situations in societies; however, it is difficult to grasp this information immediately after an earthquake event. In this study, an earthquake damage assessment methodology for buildings is proposed for estimating damage situations immediately after severe earthquakes. A response spectrum database is constructed to provide response spectra at arbitrary locations from earthquake measurements immediately after the event. The fragility curves are used to estimate the damage of the buildings. Earthquake damage assessment is performed from the response spectrum database at the building scale to provide enhanced damage condition information. Earthquake damage assessment for Gyeongju city and Pohang city were conducted using the proposed methodology, when an earthquake occurred on September 12, 2016, and November 15, 2017. Results confirm that the proposed earthquake damage assessment effectively represented the earthquake damage situation in the city to decide on an appropriate initial response by providing detailed information at the building scale.
The first instrumental earthquake observation in Korea was started in 1905 by installing mechanical seismometers at the Incheon Observatory. Since then, the largest earthquake with a magnitude of 5.8 has occurred in Gyeongju in 2016. The seismic data on the Gyeongju earthquake are provided in the form of Mini Seed from the Korea National Earthquake Comprehensive Information System (http://necis.kma.go.kr/).
In this study, it is aimed to understand the response characteristics of Gyeongju seismic waves. The response spectra of El Centro, Taft and the 2016 Kumamoto earthquake are compared and analyzed.
In the response spectrum analysis, the acceleration response and the energy response were mainly considered.
이 연구의 목적은 과학 탐구 기반의 융합인재교육(STEAM) 프로그램을 개발하고 적용하여 중학생의 과학 자기 효능감, 진로 인식, STEM에 대한 태도 변화를 검증하는데 있다. 과학 탐구 기반의 STEAM 교육 프로그램은 ‘지진’을 주제로 ADBA 모형에 적용하여 총 6차시 분량으로 개발하였다. 중학생을 대상으로 예비적용을 거쳐 수정·보완하여 최 종적으로 개발된 프로그램은 광역시 소재의 H 중학교 3학년 학생 105명을 대상으로 효과성을 검증하였다. 자료 분석은 단일집단 사전·사후 대응표본 t-검증을 실시하여 수업 전·후의 과학 자기효능감, 진로 인식, 과학·기술·공학·수학 에 대한 태도의 변화에 대하여 효과성을 분석하였다. 결론적으로, ‘지진’을 주제로 한 과학 탐구 기반의 융합인재교육 프로그램은 학생들의 과학 자기효능감과 과학 관련 진로 인식의 향상에 효과가 있었다. 그리고 과학, 기술, 공학, 수학 에 대한 태도의 인식, 능력, 가치, 흥미의 지속 영역에서 고르게 유의미한 효과가 나타났다. 개발된 과학 탐구 기반의 융합인재교육 프로그램은 학교 현장에서 충분하게 적용될 수 있으며, 이를 통해 과학적 탐구 능력의 향상과 창의·융합 적 사고를 지닌 인재를 기르는데 도움이 될 것이다.
This research describes the impact of vertical earthquake components on the performance of typical non-ductile bridges. To achieve this goal, this research chooses a non-seismically designed reinforced concrete bridge typically found in the California area. Particularly, their columns with inadequate design have a higher possibility of shear failure. To consider this failure, the column model reflects shear-axial interaction effect and is verified by comparing simulated results and experimental data available in literature. Two computational bridge models having column shear model subjected to constant and varying axial load are then built to conduct inelastic dynamic analyses. The responses are employed to construct probabilistic seismic demand models for two bridge models. This results indicate that the consideration of shear-axial interaction effect increases the seismic demand of all bridge components in non-ductile bridges, resulting in their increased seismic vulnerability.