검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 19

        3.
        2019.04 서비스 종료(열람 제한)
        Generally, reinforced concrete structures are exposed to complex deterioration. It is necessary to investigate the effect of decreasing the strength of reinforced concrete structures subjected to aging more frequently. Therefore, this study aims to analyze the resistance to freezing and thawing during complex deterioration. After the beam specimens were prepared, the freezing and thawing tests were carried out and the strength of the specimens subjected to freezing and thawing decreased as a result of 4 - point bending test.
        4.
        2019.04 서비스 종료(열람 제한)
        The purpose of this study is to investigate the freeze - thaw behavior of FRP reinforced concrete structures. Under the same conditions, two FRP reinforced beam specimens were made, and one speciemen was subjected to freezing and thawing. Then a four-point bending experiment was conducted. As a result, it was analyzed that the load values of reinforced specimens after freezing and thawing appear less at the same displacement in displacement-load behavior.
        5.
        2019.03 KCI 등재 서비스 종료(열람 제한)
        콘크리트의 낮은 인장강도 및 균열제어 능력 등의 약한 재료성질을 개선하기 위하여 수년간 하이브리드 섬유보강 콘크리트에 관한 많은 연구가 진행되어 왔다. 그러나 비정질 강섬유와 유기섬유를 이용한 하이브리드 섬유보강 콘크리트에 관한 연구는 이루어지지 않은 실정이다. 따라서, 본 연구의 목적은 비정질 강섬유와 유기섬유로서 폴리아미드 섬유를 이용한 하이브리드 섬유보강 콘크리트의 압축강도, 장기 건조수축 및 내동해성을 평가하는 것이다. 이를 위하여 목표 압축강도 40 및 60 MPa 각각에 대해서 하이브리드 섬유 혼입률을 전체 체적비로 1.0%로 설정하여 비정질 강섬유와 폴리아미드 섬유를 이용한 하이브리드 섬유보강 콘크리트를 제작하였다. 제작된 하이브리드 섬유보강 콘크리트의 장기 건조수축 및 내동해성을 평가한 결과, 재령 365일 및 730일에서의 장기 길이변화율은 플레인 콘크리트보다 각각 30%, 25% 이상 감소된 것으로 나타났으며, 동결융해 300 사이클 후의 내구성 지수는 90% 이상으로, 내동해성이 있는 것으로 나타났다.
        6.
        2017.04 서비스 종료(열람 제한)
        In this study, To evaluate the durability of concrete by freezing-thawing, relative dynamic modulus of elasticity and surface roughness were measured. The results showed that the surface roughness can be used to understand the damage tendency of freezing-thawing and the durability of concrete.
        7.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        In this study, To evaluate the durability of concrete by freezing-thawing, relative dynamic modulus of elasticity and surface roughness were measured. The results showed that the surface roughness can be used to understand the damage tendency of freezing-thawing and the durability of concrete.
        9.
        2016.04 서비스 종료(열람 제한)
        Recently, the concern on the deterioration of concrete pavement due to de-icing salts and its counter measurements has been increased. Especially, a scaling phenomenon of concrete is defined as a general loss of surface mortar or mortar surrounding the coarse aggregate particles on a concrete surface. This problem is typically caused by the expansion of water due to freezing and thawing cycles and the use of de-icing chemicals. This paper discusses the testing conditions of freezing-thawing and scaling resistance.
        10.
        2015.10 서비스 종료(열람 제한)
        In this study, freezing and thawing test of secondary product was performed using the Fiber Reinforced polymer Cement composites. From the test result, it was found that fiber reinforced polymer cement composites resistance of freezing and thawing were better than that of conventional products.
        11.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 슬래그를 다량 치환한 콘크리트의 동결융해 저항성능에 미치는 미세공극의 영향을 검토하였다. 콘크리트는 용선예비처리슬래그가 포함된 고로슬래그 미분말을 0, 40, 70 % 치환하여 제조하였으며 압축강도 특성 및 동결융해 저항성능과 미세공극을 검토하였다. 또한 설계기준강도와 목표공기량을 설정하고, 동결융해 작용에 따른 열화를 확인하기 위하여 재령 14일의 낮은 압축강도로 인한 내력저하를 유도하였다. 실험결과, 설계기준강도를 유사하게 설정하고 목표공기량을 확보하였음에도 불구하고 콘크리트의 미세공극 분포가 상이한 결과를 나타내었다. GGBS70 시험체는 동결융해를 받지 않은 초기 0사이클에서 10~100 nm 크기의 공극량이 가장 적어 공극 내 동결할 수 있는 물의 양이 적을 것으로 판단된다. 이러한 이유로 다른 시험체에 비해 동결팽창압력이 상대적으로 작기 때문에 동결융해 저항성능이 우수한 것으로 판단된다.
        12.
        2015.04 서비스 종료(열람 제한)
        In this study, deterioration degrees of concrete was investigated at a lab under cycling freeze-thaw, which is major durability performance deterioration factors of concrete. After 300 cycles of freeze-thaw, relative dynamic modulus of elasticity and compressive strength of concrete mixed with normal Portland, SF, and Ny over 90 to 93% showed relatively low resistance of approximately 78 to 87% of those values of FA-PP-02. The SF-01 specimen showed the most excellent freeze-thaw resistance among the tested high performance concrete.
        13.
        2014.04 서비스 종료(열람 제한)
        Recently, scaling of pavement concrete is becoming problem by excessive use of deicer. The current study measured durability of concrete not considering multi-deterioration using design and construction mixing used general concrete pavement.
        14.
        2013.04 서비스 종료(열람 제한)
        Ground granulated blast furnace slag is known to be much less quality variation compared to the fly ash can be substituted. Have high salt damage resistance, and chemical resistance of concrete with ground granulated blast furnace slag substitution. The case of NPP concrete using fly ash in concrete, and is defined as less than 20% fly ash utilization. In this paper, consider a resistance to freezing-thawing of currently used to concrete in NPP structures and substitutes for ground granulated blast furnace slag
        15.
        2012.11 KCI 등재 서비스 종료(열람 제한)
        콘크리트 구조물은 일반적으로 동결융해 작용을 받는 조건에 노출되고, 이러한 동결융해작용은 콘크리트의 공극구조를 변화시키고, 콘크리트의 내구성을 저하시킬 우려가 있다. 따라서 본 연구에서는 동결융해작용에 의한 콘크리트 내부공극구조 변화와 동결융해작용을 받은 콘크리트의 내구특성을 평가하고자 하였다. 실험결과, 기존의 동결융해 평가기법에 따르면 모든 배합에서 우수한 내구성능을 나타내었으나, 동결융해 작용에 노출됨에 따라 50~100nm 크기의 공극이 크게 증가하며, 콘크리트 염화물침투저항성이 저하하였다. 수중양생 콘크리트의 공극구조와 염화물 침투저항성은 선형관계를 보이지만, 동결융해작용을 받으면 내부공극구조의 변화로 선형관계가 저하하였다. 동결융해작용과 염화물침투를 동시에 받는 구조물의 내구성 평가기준에 대한 재검토가 필요할 것으로 판단된다.
        16.
        2012.02 서비스 종료(열람 제한)
        2002년에 백두산 지역을 중심으로 강진에 의한 지표면 팽창현상이 관찰되면서, 백두산의 화산폭발 가능성이 높아지고 있다. 이에 따라, 그동안 국내에서 재난유형으로 별도의 분류가 없던 화산폭발에 대한 대책이 정부차원에서 논의되기 시작하였다. 화산폭발이 발생하면 무수한 화산재가 각종 사회기반시설을 덮게 되며, 비산에 의해 항공, 물류, 정밀기계산업 등에 타격이 발생하게 된다. 본 연구에서는 화산재를 건설재료로 활용하기 위하여 백두산, 한라산의 화산재 및 다공성의 제올라이트에 시멘트 및 메타카올린을 첨가한 재령 7일의 공시체에 대한 배합비별 동결융해 저항성을 분석하였다. 실험 결과, 재령 7일에 대하여 혼합재(화산재 및 제오라이트), 시멘트 및 메타카올린의 비율을 3.5:1:0.1로 배합한 경우 동결융해 저항성이 가장 우수한 것으로 나타나, 재령 및 단위시멘트량의 증가, 메타카올린의 첨가가 동결융해 저항성에 큰 영향을 미치는 것으로 나타났다.
        17.
        2010.01 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 FRP 복합체로 보강된 콘크리트 구조물의 동결융해 저항성을 평가하기 위하여 동결융해 진행에 따른 FRP 복합체의 인장강도 및 콘크리트에 대한 인발접착강도의 변화를 측정하였다. 주 실험변수는 동결융해 조건, FRP 복합체의 종류, 동결융해 싸이클로 설정하였다. KS F 2456의 동결융해 시험규격에 따라 실시된 탄소섬유복합체의 인장강도는 최종 싸이클까지 변화가 없었으며, 또한 접착성능의 저하도 관측되지 않아 CFRP의 동결융해 저항성은 매우 우수한 것으로 나타났다. 이에 대하여 유리섬유복합체의 경우는 최종 싸이클에서의 인장강도 및 인발접착강도가 각각 10%, 15% 저하된 것으로 나타나 부분적으로 성능이 저하되는 것으로 나타났다. 그러나 접착강도 평가시 지속적인 동결수가 공급되는 상황에서는 상이한 결과가 나타날 수 있으므로 이에 대한 주의가 필요할 것으로 판단된다.
        18.
        2007.11 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 염화물이 함유된 동결수에 의한 콘크리트의 내동해성을 검토하기 위하여 동결융해 및 표면스케일링 저항성을 평가하고자 하였으며, 이를 위한 배합으로서 물결합재비는 0.37, 0.42, 0.47의 3수준, 결합재 방식은 일반 OPC 콘크리트, 고로슬래그 미분말 50%의 2성분계 콘크리트 및 플라이애시 15%와 고로슬래그 미분말 35%의 3성분계 콘크리트로 설정하였다. 그 결과, 고로슬래그 미분말 50% 및 플라이애시 15%와 고로슬래그 미분말 35%의 혼합 시멘트계 콘크리트의 경우 일반 OPC 콘크리트에 비하여 동결융해 및 표면스케일링 저항성이 상대적으로 우수하게 나타났으며, 이를 통해 내구성 저하가 우려되는 해양 환경 하에서 비래염분 및 비말 등의 해수의 작용에 의한 콘크리트의 내구성 저하현상을 억제하기 위한 방안으로서 슬래그의 활용이 유효함을 확인할 수 있었다.