검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 26

        1.
        2023.01 KCI 등재 구독 인증기관·개인회원 무료
        생물환경조절학회지 31권 4호에 게재된 논문의 사사가 잘못 기재되어 있어 바로 잡습니다.
        2.
        2023.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The external weather conditions including temperature and wind speed in the Saemangeum reclaimed land is different from that of the inland, affecting the internal environment of the greenhouse. Therefore, it is important to select an appropriate covering material considering the insulation effect according to the type and characteristics of the covering material considering the weather condition in the Saemangeum reclaimed land. A hexahedral insulation chamber was designed to evaluate the insulation efficiency of each glass-clad material in the outside weather condition in reclaimed land. In order to evaluate the insulation effect of each covering material, a radiator was installed and real-time power consumption was monitored. 16-mm PC (polycarbonate), 16-mm PMMA (polymethyl methacrylate), 4-mm greenhouse glass, and 16-mm double-layered glass were used as the covering materials of the chamber. In order to understand the effect of the external wind directions, the windward and downwind insulation properties were evaluated. As a result of comparing the thermal insulation effect of each greenhouse cover material to single-layer glass, the thermal insulation effect of double-layer glass was 16.9% higher, while PMMA and PC were 62.5% and 131.2% higher respectively. On average the wind speed on the windward side was 53.1% higher than that on the lee-wind side, and the temperature difference between the inside and outside of the chamber at the wind ward side was found to be 52.0% larger than that on the lee ward side. During the experiment period, the overall heating operation time for PC was 39.2% lower compared to other insulation materials. Showing highest energy efficiency, and compared to PC, single-layer glass power consumption was 37.4% higher.
        4,000원
        3.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내외로 첨단 ICT 융합기술이 농업 분야에 적용되기 시작 하면서, 시설원예 설비들이 고도화되고, 스마트팜 구축 기술 및 인력이 축적되기 시작하였다. 그러나 우리나라 농촌의 경 우, 농업생산 연령의 고령화, 국내 농촌 인구의 지속적인 유출, 저출산 등으로 인하여 스마트팜 확대 및 적용에 어려움이 많 은 실정이다. 따라서 공간 및 시간에 구속을 받지 않는 간편한 농업인 교육 프로그램이 필요하며, 최근 부상하고 있는 시뮬 레이션 기술을 활용한다면 농업 교육용 시뮬레이션 툴 개발도 가능할 것으로 판단된다. 온실 환경 제어 모델을 이용한 시뮬 레이션은 다양한 지역과 기상 조건 하에서 대상 온실의 열과 물질에너지의 상호작용을 합리적으로 예측할 수 있게 해준다. 본 연구에서는 온실 환경 제어 모델을 활용하여 외부 기상 데 이터를 통해 온실의 환경 변화를 예측하고 가상의 환경 제어시스템을 통해 환경 제어 시 필요한 에너지값들을 시뮬레이션 할 수 있었다. 이러한 결과를 통해 이용자가 직접 맞춤형 환경 제어를 할 수 있도록 편의성을 고려한 사용자 인터페이스를 구축할 것이며, 실제 파프리카 재배 온실의 제어 요소들을 반 영할 수 있도록 설계될 것이다. 농업용 교육 시뮬레이션 툴을 최근 활발하게 연구가 이루어지고 있는 작물 생육 모델링 기 술 및 전산유체역학 기술과 융합하면 더욱 타당한 결과를 보 일 것이다.
        4,300원
        4.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        스마트팜 요소들 중에서 중요한 요인 중 하나는 환경 계측이 다. 본 연구에서는 오픈 소스 프로그램인 아두이노, 앱 인벤터 와 노드 레드를 이용하여 로라와 블루투스 무선 통신을 통한 환 경 계측 모니터링 시스템을 설계하였다. 이 시스템은 아두이 노, 로라 쉴드, 온습도 센서(SHT10), 이산화탄소 센서(K30) 로 구성되었다. 아두이노(Arduino) 프로그램에서 사용된 라 이브러리로는 LoRa.h, Sensirion.h, LiquidCrystal_I2C.h와 K30_I2C.h를 사용하였다. 일정한 주기로 센서에서 환경 데 이터를 받을 때, 데이터의 안정화를 위해 평균값을 사용한 코 딩을 사용하였다. 사용자 인터페이스로 노드 레드와 앱 인벤 터 프로그램을 이용하여 안드로이드 기반의 앱을 개발하였다. 아두이노의 시리얼 화면과 스마트 폰의 화면 및 노드 레드의 사용자 인터페이스에 출력되는 화면으로 센서에 위한 환경 자 료가 잘 수집되어 디스플레이되는 것을 볼 수 있었다. 이러한 오픈소스 기반의 플랫폼과 프로그램들은 다양한 농업 응용 분 야에 적용될 것이다.
        4,000원
        5.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.
        4,000원
        6.
        2019.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to provide basic data for setting environmental design standards for domestic greenhouses. We conducted experiments on thermal environment measurement at two commercial greenhouses where hot water heating system is adopted. We analyzed heat transfer characteristics of hot water heating pipes and heat emission per unit length of heating pipes was presented. The average air temperature in two greenhouses was controlled to 16.3oC and 14.6oC during the experiment, respectively. The average water temperature in heating pipes was 52.3oC and 45.0oC, respectively. Experimental results showed that natural convection heat transfer coefficient of heating pipe surface was in the range of 5.71~7.49W/m2 oC. When the flow rate in heating pipe was 0.5m/s or more, temperature difference between hot water and pipe surface was not large. Based on this, overall heat transfer coefficient of heating pipe was derived as form of laminar natural convection heat transfer coefficient in the horizontal cylinder. By modifying the equation of overall heat transfer coefficient, a formula for calculating the heat emission per unit length of hot water heating pipe was developed, which uses pipe size and temperature difference between hot water and indoor air as input variables. The results of this study were compared with domestic and foreign data, and it was found to be closest to JGHA data. The data of NAAS, BALLS and ASHRAE were judged to be too large. Therefore, in order to set up environmental design standards for domestic greenhouses, it is necessary to fully examine those data through further experiments.
        4,000원
        7.
        2018.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 농업 및 정보 통신 기술의 융합을 기반으로 국내외 스마트 농장 서비스 모델을 검토하고 한국의 스마트 온실을 개선하기 위해 필요한 다양한 요인을 조사 하기 위해 수행되었다. 국내 스마트 온실의 작물 생육모델 및 환경모델에 관한 연구는 제한적이었고, 연구를 위한 인프라를 구축하는 데는 많은 시간이 필요하다. 이러한 문제의 대안으로 클라우드 기반 연구 플랫폼이 필요하다. 제안된 클라우드 기반 연구 플랫폼은 통합 데이터, 생육 환경모델, 구동기 제어 모델, 스마트 온실 관리, 지식 기반 전문가 시스템 및 농가 대시보드 모듈을 통해 통합적 데이터 저장 및 분석을 위한 연구 인프라를 제공한다. 또한 클라우드 기반 연구 플랫폼은 작물 생육환경, 생산성 및 액추에이터 제어와 같은 다양한 요인들 간의 관계를 정량화하는 기능을 제공하며, 연구자는 빅데이터, 기계 학습 및 인공지능을 활용하여 작물 생육 및 생장 환경 모델을 분석할 수 있다.
        4,000원
        8.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 온실의 구조설계용 작물하중을 산정하는데 필요한 기초자료를 제공하기 위하여 각국의 온실구조설계용 작물하중 기준들을 비교분석하고 여러 가지 온실작물들에 대하여 작물하중을 직접 측정하고 분석하였다. 설계 작물하중에 대한 각국의 기준들을 비교분석한 결과 나라들 마다 서로 많은 차이를 보여주고 있으며, 우리나라 기준들은 외국의 기준들을 그대로 인용하고 있는 것으로 나타나 우리나라 실정에 맞는 작물하중 기준이 제시될 필요가 있다고 판단된다. 최대 주당 작물하중이 토마토는 두 가지 온실에서 각각 3.3kgf·plant-1와 3.9kgf·plant-1로 나타났고, 오이는 0.75kgf·plant-1, 가지는 1.9kgf·plant-1, 딸기는 재배베드를 포함하여 2.1kgf·plant-1 으로 나타났다. 단위면적당 작물하중은 토마토가 평균 8.5kgf·m-2으로 나타났고, 오이와 가지는 각각 2.1kgf·m-2 과 2.4kgf·m-2으로 토마토의 하중보다 훨씬 낮게 나타났다. 우리나라 온실설계기준에 제시된 작물하중은 토마토와 오이의 경우 15kgf·m-2으로 본 연구에서 측정된 값보다 훨씬 높았다. 우리나라의 설계기준이 네덜란드의 기준을 그대로 인용한 것으로 판단되기 때문에 이러한 차이를 고려하여 우리나라의 작물하중 설계기준에 대한 재검토가 이루어져야 할 것으로 판단된다. 딸기의 작물하 중은 행잉베드를 포함한 중량이 21.0kgf·m-2로 네덜란드의 설계기준인 30kgf·m-2보다 훨씬 작았다.
        4,000원
        9.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        온실의 냉난방시스템 설계 기준에 적용하기 위한 외부 기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010 년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10 년 주기로 설계기준을 개정할 필요가 있는 것으로 생각 된다. 본 연구에서는 현재 기후평년값 기준인 1981 ~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.
        4,300원
        10.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new design concept for integrated thermal energy storage system is suggested to increase energy saving rate for heating and cooling system of the closed glass greenhouse. Heat pump of air source is installed in the mechanical room and air flows then controlled by damper system located between the greenhouse and outdoor environments. A damper control algorithm is designed to enhance the usage of excessive energy in the glass greenhouse. Since the proposed system is installed at the actual glass greenhouse site for experimental verification of energy savings, the proposed system with damper control is compared with conventional greenhouse heating and cooling system. From results, it is found that more than 10% increase of energy saving rate is achieved.
        4,000원
        11.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 BES 기법을 활용하여 온실을 대상으로 실시간 에너지교환 시뮬레이션 모델 개발 및 검증을 수행하고 냉·난방부하 산정 및 경향성을 분석하였다. 우선 BES 기법과 현장실험을 기반으로 온실의 실시간 에너지 교환 모델을 개발하였다. 광흡수율, 엽면적지수, 잎 특성 길이 등 대상작물인 애플망고의 특성 값들과 온실 내부 이산화탄소 농도, 광량, 온도 등 실시간 입력 자료를 고려하여 작물 및 토양의 에너지교환을 구현하였다. 모델의 검증은 온실 내부 기온으로 수행하였으며 실측 내부 기온과 연산된 내부 기온 간의 결정계수, 일치도로 평가 하였다. 내부 기온 비교는 결정계수 0.89, 일치도 0.93으로 높은 유사성을 확인하였으며 모델의 유의성을 판단하였다. 개발한 모델과 2005년부터 2014년까지의 기상자료, 대상작물의 생육단계별 적정생육온도를 이용하여 대상온실의 냉·난방부하 산정하였다. 연도별 냉·난방부하산정 및 경향성을 파악하였으며 최대 냉·난방부하 산정을 통하여 대상온실의 냉·난방장치 용량설계의 기초자료를 확보하였다. 최근 10년 치 기상자료를 통하여 평균 최대 난방부하 525,473 kJ·hr-1, 평균 최대냉방부하 630,870 kJ·hr-1가 산정되었으며 대상 온실에 지열, 온배수, 태양열 등 신재생에너지를 활용할 경우 유용하게 활용될 것으로 판단된다. 본 연구를 통하여 온실 내 각 구성요소 간의 실시간 에너지교환을 모의할 수 있었으며 추후 온배수 활용을 위한 저류조, 히트펌프, 축열조 등의 설비를 구현함에 따라 전반적인 냉·난방 시스템의 구현 가능성을 확인하였다. 또한 동적 해석방법을 통하여 재배작물, 생육단계 및 토양을 고려하였으며 온실 에너지교환 모델에 다양한 형태로 적용 가능할 것으로 판단된다.
        4,000원
        12.
        2016.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 MRV 규제 대응을 위해 선박 운항효율데이터 수집 및 검증 시스템을 구축하고 이를 활용하여 해운선사 업무 지원과 국가 온실가스 인벤토리 산정이 가능한 국제해운 에너지효율 포탈 시스템을 설계하였다. 시스템 요구조건을 도출하기 위하여 EU MRV 법안과 IMO MRV 논의사항, 해운선사의 선박에너지효율과 온실가스규제 대응 및 국제해운 온실가스 통계 현황에 대하여 분석 하고 선박 에너지효율과 온실가스 배출량 데이터 수집을 위하여 선내 장비, 에너지효율 측정 장비, 운항보고서를 활용한 데이터 수집 모듈과 선박에서 수집된 데이터를 육상으로 전송하기 위해 관리가 용이하고 사용량이 최소화된 데이터베이스기반 전송 모듈을 설계하 였다. 수집된 데이터의 표준보고양식 변환, 모니터링, 통계 및 분석, 검증, 보고서 자동생성과 국가 온실가스 인벤토리 지원이 가능한 국제해운 에너지 포탈시스템을 설계하였다.
        4,000원
        13.
        2015.12 구독 인증기관 무료, 개인회원 유료
        Since 2000s, proper utilization of IoT (Internet of Things) technology is a key factor for a firm to become more competitive, and this stream is not exceptional for the food and agriculture industry. Along with this stream, Korea government organization, for example MAFRA (Ministry of Agriculture, Food and Rural Affairs), elected to adopt IoT technology, such as USN and RFID technologies, in the food and agriculture industry. Based on the IoT technology, MAFARA launched six “IoT based farm” project in 2007. IoT based farm project includes IoT based greenhouse system project, and it shows drastic efficiency in terms of cost reduction. When it comes to the productivity, however, the effect of IoT based greenhouse system is still ambiguous. In this regard, this study conducted systems analysis and design for IoT based tomato greenhouse in order to help farmers’ decision making related to the productivity by establishing standardized database structure and designing output form to analyze productivity indices. Proposed systems analysis and design can be utilized as a data analysis tools by farmers. Productivity data from the proposed systems is can be used by researchers to identify the relationship among environment, plant growth and productivity. Policy makers also can refer to the data and output forms to predict the quantity of fruit during certain period and to revise production guideline more precisely.
        4,000원
        14.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: This study devotes its energies to estimate greenhouse gas emissions for types of horizontal highway designs. METHODS: This paper suggested two types of road scenarios, scenario 1 is made by the lack of road design consistency. Beside scenario 1, scenario 2 is made by good road design. For comparisons of greenhouse gas emissions, driving simulator was used. RESULTS: Emission rates of road scenario 1 are 1.4 times higher than scenario 2 in the driving simulator. CONCLUSIONS : This study may have important implications for contributing to the application of road alignment technology for reduction of greenhouse gases as quantifying the correlations between greenhouse emissions and various road alignments. Consequently, this study will help road designers determine which roads are best alternatives in the process of choosing the roads in the future in terms of environmental benefits.
        4,000원
        15.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기상청에서 제공하는 전체 기상자료와 평년값 자료 및 태양에너지학회에서 제공하는 표준기상데이터를 이용하여 위험률별 난방설계용 외기온과 상대습도, 냉방설계용 건구온도, 습구온도 및 일사량 자료를 분석하였다. 표준 기상데이터는 평균에 가장 가까운 대표성을 갖는 1개년의 데이터로 가공 처리한 매시간별 기상자료이고, 평년 값 자료는 30년(1981~2010년) 평균 일별 기상자료이며, 전체 기상자료는 평년값과 동일기간의 매시간별 기상자료이다. 일부 분석방법은 평년값 자료를 이용하는 경우도 있지만 대부분 매시간별 기상자료가 필요하고 대표성을 갖기 위해서는 표준기상데이터를 이용하는 것이 가장 적합하다. 그러나 현재 표준기상데이터는 서울과 6대 광역시 등 7개 지역만 제공되고 있기 때문에 전국을 커버 할 수 있는 지역별 온실 환경설계용 기상자료의 구축에는 전체 기상자료를 이용할 수밖에 없다. 따라서 본 연구에서는 표준기상데이터가 제공되고 있는 7개 지역을 대상으로 전체 기상자료 및 평년값 자료를 이용한 방법으로 분석하여 표준기상데이터로 구한 값과 비교 검토하였다. 위험률별 설계 기상자료는 전체 기상자료를 이용하여 구한 평균값이 표준기상데이터로 구한 결과와 잘 일치하였다. 따라서 표준기상데이터가 없는 지역의 위험률별 설계용 기상자료는 전체 기상자료를 이용하여 구하고, 전체자료 기간의 평균값을 온실의 환경설계 기준으로 사용하며, 최대값과 최소값을 제공함으로써 참고자료로 활용할 수 있도록 하는 것이 합리적인 방법으로 판단된다. 최근의 기후변화 문제로 냉난방 설계기온의 지 속적인 변화가 예상되므로 이에 대응하기 위해서는 전문 가들로 구성된 온실설계위원회와 같은 기구의 설치가 절실히 요청된다. 위원회에서는 자료기간 및 분석방법에 대한 기준을 설정하고, 최소한 10년 간격의 정기적인 검토를 통하여 기상자료를 분석하고 온실설계기준 및 가이드라인을 제공할 필요가 있다.
        4,000원
        16.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존의 온실설계와 관련된 기준들은 1990년대 까지의 기상자료를 이용하여 산정된 설계풍속 및 적설심으로 최근 급변하는 우리나라 기상특성을 반영하기에는 어려움이 있다. 본 연구에서는 온실 설계에 있어서 기존의 기준들에 대한 문제점을 개선하고 활용도가 높은 설계풍속 및 적설심 자료를 제공하기 위해 1961년부터 최근 2011년까지 각 지역별 총 72개 지점의 기상관측소에서 측정한 기상자료를 이용하여 우리나라 전국 170개의 시·군별 설계풍속 및 적설심을 산정하였다. 그 결과, 재현기간 100년을 기준으로 풍속의 경우, 22.5~65.0 m․s-1 범위로 홍천이 22.5 m․s-1 로 가장 낮았고, 흑산도가 65.0 m․ s-1 으로 가장 높게 나타났다. 이때 기상자료의 수가 20년 미만인 흑산도를 제외하면 고산이 63.0 m․s-1 으로 가장 높은 것으로 나타났다. 적설심의 경우, 5.4~259.7 cm 범위로 고산이 5.4 cm로 가장 낮았고, 울릉도가 259.7 cm 로 가장 높게 나타났다. 전형적으로 다설지역인 울릉도(259.7 cm)와 대관령 (225.4 cm)을 제외하면 동해가 123.3 cm 으로 가장 높았다. 그리고 각 지역별 설계풍속 및 적설심에 대하여 본 연구와 기존의 기준을 비교해 보면, 설계풍속 및 적설심의 차이가 크게 발생한 지역들은 기존의 기준이 본 연구보다 비교적 높게 산정된 경향을 보였다. 따라서 최신 기상자료를 이용한 본 연구의 결과를 이용한다면 원예시설의 설계 및 시공 시 온실의 안전성뿐만 아니라 경제성에도 상당히 유리 할 것으로 판단되었다.
        5,400원
        17.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 시설재배에서 참외를 수확할 수 있는 로봇의 엔드이펙터를 개발하기 위한 전단계로서, 참외의 엔드이펙트 중에서 소프트 핸드링이 가능한 그립퍼와 참외 줄기를 절단하는 커터를 설계하기 위해 참외의 기하학, 압축, 절단, 마찰 특성 등을 분석하였다. 그 결과 참외의 길이는 평균 108mm, 직경은 중간지점에서 평균 70mm, 중량은 평균 188g, 부피는 평균 333mL, 진원도는 평균 3.8mm로 나타났다. 참외의 중량(W)에 대하여 길이(L)와 직경(D2)을 변수로 하는 식 W = La × D2 b로부터 비선형 회귀분석을 실시한 결과 a는 2.0279, b는 −0.9998의 상 수값을 가지는 상관관계가 있는 것으로 나타났다. 참외 줄기의 지름은 평균 3.8mm이며, 참외 줄기는 중심으로 부터 반경 5mm 범위 내에서 대부분 분포하였다. 참외의 항복치와 압축강도, 경도의 평균값은 각각 36.5N/cm2, 185.7N/cm2, 636.7N/cm2이며, 참외 줄기의 절단력과 절단강도는 각각 2.87 × 10−2N와 5.60N/cm2로 나타났다. 참외의 마찰계수는 고무가 0.609으로 가장 높게 나타났고, 그 다음으로 알루미늄이 0.393, 스테인레스강이 0.177, 테프론이 0.079로 나타났다. 분석된 자료를 토대로 엔드 이펙터 설계시 동작에 따른 위치 오차와 안전율을 감안 하여, 그립퍼의 및 커터의 크기, 선회반경, 설치위치, 구 동모터의 동력, 재료 및 재질의 선정 등에 적용할 수 있을 것으로 판단되었다.
        4,000원
        18.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 온실 설계의 기초자료로 이용할 목적으로 온실에서 재배되고 있는 작물 중에 작물하중이 상대적으로 큰 토마토와 파프리카를 대상으로 작물하중을 측정하였다. 재배기간 중 동절기의 기온은 평년대비 최저 및 평균기온의 최대 차이는 각각 −5.6oC 및 −4.9oC로 나타났고, 하절기의 최대 온도 차이는 각각 3.0oC 및 1.5oC를 나타났다. 푸쉬풀 게이지의 측도 설정한 결과, 결정계수가 0.99 정도로서 상관관계가 아주 높은 것으로 나타났다. 파프리카의 재식밀도는 각각 3.43 및 3.56plant · m−2이었고, 토마토는 2.13plant · m−2이었다. 그리고 생산량은 각각 4.1, 4.3kg · plant−1 및 16.2kg · plant−1 정도로 서 단위면적당 생산량으로 보면, 14.1, 15.2kg · m−2 및 34.5kg · m−2 정도인 것으로 파악되었다. 파프리카 및 토마토의 경우, 최대하중은 약 1.3, 1.5kg · plant−1 및 3.3kg · plant−1 정도이었다. 파프리카 재배에서 작물을 중방에 매달 경우, 중방에 작용하는 총 작물하중은 15.3~15.9kg · m−2 정도로 예측되고, 재배베드를 지지하는 거터의 무게를 고려하면 총 무게는 26.0~26.9kg · m−2 정도이었다.
        4,000원
        19.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 간척지 내 온실의 설계에 합리적으로 적용할 수 있는 설계 풍속 및 적설심을 제공하기 위해, 최근 2011년 까지 각 지역별 총 72개 지점의 기상관측소에서 측정한 기상자료를 이용하여 우리나라 간척지 대부분이 분포하고 있는 안산시, 화성시, 당진시, 태안군, 보령시, 군산시, 해남군, 진도군, 장흥군 및 고흥군 등에 대하여 재현기간별 설계 풍속 및 적설심을 산정하였다. 그 결과, 본 연구와 기존의 관련기준과 비교해 보면 설계 풍속 및 적설심의 차이가 크게 발생한 지역 대부분은 기존의 관련 기준이 과도하게 높게 산정된 경우가 많은 것으로 나타났다. 간척지의 경우는 재현기간 30년을 기준으로 대부분 설계풍속이 30 m․s-1 이상을 초과하는 것으로 나타났으며, 그 이하의 지역들도 거의 30 m․ s-1와 유사한 값을 보였다. 그리고 간척지역들 중 군산시는 설계적설심 또한 33.7 cm로 72개 지역들 중에서 비교적 높은 순위(11위)의 값을 나타내었다. 따라서 간척지 내 온실은 바람에 강한 구조로 설계하는 것이 적절할 것으로 판단되었으며, 군산지역은 적설의 영향도 함께 고려해야하기 때문에 다른 간척지에 비해 시설원예 대상지역으로는 다소 불리할 것으로 판단되었다.
        4,000원
        20.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 화력발전소에서 온배수의 형태로 배출되는 폐열을 히트펌프의 열원으로 이용하여 온실의 난방에 활용할 수 있는 히트펌프 시스템을 설계 제작하였으며, 난방 성능을 분석하여 PE 파이프 열교환기의 설계기준을 제시하고자 하였다. PE 파이프 열교환기의 내경은 20mm, 두께는 2mm였으며, Roll의 직경은 1,000mm로 하였다. 연구결과 PE파이프 열교환기의 적정 길이는 1.0RT당 75m로 설계하는 것이 바람직할 것으로 판단되었으며, 이때 히트펌프시스템의 난방성능계수(COPh)는 3.8로 나타났다.
        4,000원
        1 2