Recently, in newly constructed apartment buildings, the exterior wall structures have been characterized by thinness, having various openings, and a significantly low reinforcement ratio. In this study, a nonlinear finite element analysis was performed to investigate the crack damage characteristics of the exterior wall structure. The limited analysis models for a 10-story exterior wall were constructed based on the prototype apartment building, and nonlinear static analysis (push-over analysis) was performed. Based on the finite element (FE) analysis model, the parametric study was conducted to investigate the effects of various design parameters on the strength and crack width of the exterior walls. As the parameters, the vertical reinforcement ratio and horizontal reinforcement ratio of the wall, as well as the uniformly distributed longitudinal reinforcement ratio and shear reinforcement ratio of the connection beam, were addressed. The analysis results showed that the strength and deformation capacity of the prototype exterior walls were limited by the failure of the connection beam prior to the flexural yielding of the walls. Thus, the increase of wall reinforcement limitedly affected the failure modes, peak strengths, and crack damages. On the other hand, when the reinforcement ratio of the connection beams was increased, the peak strength was increased due to the increase in the load-carrying capacity of the connection beams. Further, the crack damage index decreased as the reinforcement ratio of the connection beam increased. In particular, it was more effective to increase the uniformly distributed longitudinal reinforcement ratio in the connection beams to decrease the crack damage of the coupling beams, regardless of the type of the prototype exterior walls.
초고층 건물에서 수평변위 제어와 수직부재에서 발생하는 부등축소에 대한 검토가 필수적이다. 이러한 부등축소는 비구조요소의 사용성과 구조요소의 안전성에 대해 문제를 야기할 수 있다. 따라서 이 연구에서는 120층 규모의 철근콘크리트 주거용 초고층 건물에 대해 시공단계해석을 수행하여 각 수직부재의 부등축소량을 비교하고 콘크리트의 장기거동의 영향을 분석하였다. 이를 위해 영향요 인에 따라 축소량을 탄성축소량, 크리프축소량, 건조수축축소량으로 구분하여 검토하였으며 최대 절대축소량에 대한 지배적 요인을 분석하였다. 또한, 입주완료 후 30년에서 발생한 부등축소량에 대해 사용성 검토를 진행하였으며, 구조요소에 대해 설계단계와 시공 단계의 부재력을 비교하여 분석하였다.
초고층 건물에서 수평변위 제어와 수직부재에서 발생하는 부등축소에 대한 검토가 필수적이다. 수평변위 제어를 위해 근래에 아웃 리거 구조시스템과 메가 구조시스템을 횡력저항시스템으로 사용한 초고층 건물이 증가하고 있다. 또한, 부등축소로 인한 구조적 문 제를 해결하기 위해 부등축소량 예측과 예측결과를 통한 시공단계에서의 보정방법이 연구되어 왔으나 부등축소에 대한 횡력저항시 스템의 영향 비교는 드문 편이다. 따라서, 본 논문에서는 수평변위 제어를 위해 아웃리거 구조시스템과 메가 구조시스템을 사용한 60 층 규모의 철근콘크리트 주거용 초고층 건물에 대해 시공단계해석을 통한 부등축소를 비교하고 그 영향을 분석하고자 한다. 또한, 부 등축소는 비구조요소의 파손 및 구조요소에 부가하중을 유발하기도 하며 부등축소가 야기한 문제는 초고층 건물에서 중요한 부재를 손상시킬 수 있으므로 각 횡력저항시스템별로 수직부재의 부등축소에 대한 영향을 분석하였다.
Seismic fragility was assessed for non-seismic reinforced concrete shear walls in Korean high-rise apartment buildings in order to implement an earthquake damage prediction system. Seismic hazard was defined with an earthquake scenario, in which ground motion intensity was varied with respect to prescribed seismic center distances given an earthquake magnitude. Ground motion response spectra were computed using Korean ground motion attenuation equations to match accelerograms. Seismic fragility functions were developed using nonlinear static and dynamic analysis for comparison. Differences in seismic fragility between damage state criteria including inter-story drifts and the performance of individual structural members were investigated. The analyzed building had an exceptionally long period for the fundamental mode in the longitudinal direction and corresponding contribution of higher modes because of a prominently insufficient wall quantity in such direction. The results showed that nonlinear static analyses based on a single mode tend to underestimate structural damage. Moreover, detailed assessments of structural members are recommended for seismic fragility assessment of a relatively low performance level such as collapse prevention. On the other hand, inter-story drift is a more appropriate criterion for a relatively high performance level such as immediate occupancy.
최근 일본의 건축구조기준(AIJ 2015)에서는 CFD 해석을 통한 풍하중 산정을 허용한 바 있다. 이는 컴퓨터의 연산 능력 향상 및 CFD 해석 이론의 발전으로 인해 해석의 결과가 풍동실험의 결과와 유사한 수준에 도달하였음을 뜻한다. 본 연구에서는 먼저 CFD 해석의 이론적 배경을 살펴보고, 일본의 건축구조기준 및 유럽의 과학기술연구 프로그램인 COST에서 권장한 CFD 해석 절차를 토대 로 해석을 진행하였다. 해석 결과의 신뢰성을 검증하기 위해 Tokyo Polytechnic University에서 제공하는 풍동실험 데이터를 사용하였 고, 해석과 실험의 유사성을 평가하기 위하여 형상비가 3, 4, 5일 때의 풍방향하중을 비교하였다.
In this paper, the displacement response to seismic loads was analyzed after installing TMD in spatial structures and high-rise buildings. In the case of a spatial structures, since it exhibits complex dynamic behavior under the influence of various vibration modes, it is not possible to effectively control the seismic response by installing only one TMD, unlike ordinary structures. Therefore, after installing eight TMDs in the structure, the correlation between displacement response and mass ratio was examined while changing the mass. The TMD must be designed to have the same frequency as the structure frequency so that the maximum response reduction effect can be exhibited. It can be confirmed that the most important variable is to select the optimal TMD mass in order to install the TMD on the structure and secure excellent control performance against the earthquake load. As a result of analyzing the TMD mass ratio, in the case of high-rise buildings, a mass ratio of 0.4% to 0.6% is preferable. In spatial structures, it is desirable to select a mass ratio of 0.1% to 0.2%. Because this study is based on the theoretical study based on numerical analysis, in order to design a TMD for a real structure, it is necessary to select within a range that does not affect the safety of the structure.
필로티는 현대건축에서 주차공간의 활용, 보행자의 통로 등 여러 가지 이점을 가지고 있기 때문에 아파트와 오피스텔과 같은 고층건축물에 많이 사용되고 있다. 이러한 고층건축물의 필로티 형태 특성상 강풍이 불 때 바람이 집중되기 때문에 필로티 천장과 벽 면에 위치하고 있는 외장재 및 주골조가 파손되기 쉽다. 그리고 이러한 외장재 및 주골조의 탈락으로 인해 2차 피해가 발생할 우려가 있다. 하지만 건축구조기준(KBC-2016)에서는 고층건축물에 대한 천장 및 벽면의 풍압계수만을 제시할 뿐 필로티에 대한 기준이 명시 되어 있지 않다. 본 논문은 고층건축물에서 사용되는 필로티의 종류로서 관통형, 개방형 필로티를 선정하였고, 필로티의 폭과 깊이를 변수로 하여 풍동실험을 진행하였다. 그리고 변수에 따른 풍압계수의 특성을 파악하였고 비교 및 분석하였고 본 논문의 실험결과를 통 하여 필로티 설계 시 활용할 수 있는 주골조 및 외장재 설계용 풍압계수를 제시하였다.
이 연구에서는 국내 설계기준인 KBC 2016, 미국 기준 ASCE 7-16, 국제 표준 ISO 4354:2012의 고층건물 설계를 위한 풍방향 풍하중을 비교 분석하였다. 각 기준에서 사용하는 기본풍속, 풍방향 풍하중의 가스트영향계수 산정 과정과 이를 구성하는 평균 성분, 비공진 성분, 공진 성분의 차이를 비교 분석하였다. ISO에서는 10분 평균 풍속과 3초 가스트 풍속에 의한 두 가지 하중 산정법을 사용하며, 고층건물에서는 10분 평균 풍속에 의한 산정법이 하중을 6% 더 크게 산정한다. 10분 평균 풍속을 사용하는 KBC 풍하중은 ISO 평균과 거의 일치하였으며. 3초 가스트 풍속을 사용하는 ASCE 7-16은 ISO 피크보다 6% 작게 나타났다. 이 연구에서는 이러한 차이를 줄이기 위한 개선사항들을 제시하였다.
이 연구에서는 KBC 2016 풍하중의 산정 배경을 구체적으로 설명하고, 콘크리트 이중골조 고층건물에서의 풍하중과 지진하중을 비교하였다. 풍하중은 평균성분, 비공진성분, 공진성분으로 구성되며, 건물이 고층화될수록 공진성분이 우세해진다. 구조물의 형 상비가 3보다 큰 경우 풍직각방향 및 비틀림 하중을 고려하며, 풍방향하중과 설계지진하중보다 풍직각방향 풍하중이 지배적이게 된다.
Recently, the concept of an outrigger damper system with a damper added to the existing outrigger system has been developed and applied for dynamic response control of high-rise buildings. However, the study on the structural characteristics and design method of Outrigger damper system is in the early stages. In this study, a 50 story high - rise building was designed and an outrigger damper system with viscoelastic damper was applied for wind response control. The time history analysis was performed by using the kaimal spectrum to create an artificial wind load for a total of 1,000 seconds at 0.1 second intervals. Analysis of the top horizontal maximum displacement response and acceleration response shows that outrigger damper systems are up to 28.33% and 49.26% more effective than conventional outrigger systems, respectively. Also, it is confirmed that the increase of damping ratio of dampers is effective for dynamic response control. However, since increasing the damping capacity increases the economic burden, it is necessary to select the appropriate stiffness and damping value of the outrigger damper system.
Base isolation system is generally used for low-rise buildings. For high-rise buildings subjected to earthquake loads, a mid-story isolation system was proposed and applied to practical engineering. In this study, seismic responses of high-rise buildings considering the installation story of the mid-story isolation system were evaluated. To do this, the 20-story and 30-story building were used as example structures. Historical earthquakes such as Kobe (1995), Northridge (1994) and Loma Prieta (1989) earthquakes were employed applied as earthquake excitations. The installation location of the mid-story isolation system was changed from the bottom of the 1st floor to the bottom of the top floor. The seismic responses of the example building were investigated by changing the location of the isolation layer. Based on the analytical results, when the seismic isolation system is applied, story drift ratio and acceleration response are reduced compared to the case without the isolation system. When the isolation layer is located on the lower part of the building, it is most effective. However, in that case, the possibility that the structure is unstable increases. Therefore, an engineer should consider both structural efficiency and safety when a mid-story isolation system for a high-rise building is designed.
Recently, the trend is emerging a variety of irregular tall buildings. It is important to design the building for lateral load according to this trend. Fluid Structure Interaction(FSI) simulation can be performed to understand the vibrations of the structure against dynamic wind loads. In order to make the physical characteristics of the actual structure and the analytical model the same, we studied core inserting equivalent stiffness modeling method. As a result of this analysis, the stiffness of the structure can be set similar to that of the two axes of the structure, and turbulence can be reproduced through the acceleration tendency.
The objective of this study is to apply performance-based seismic design to high-rise apartment buildings in Korean considering collapse prevention level. The possible issues during its application were studied and the suggestions were made based on the findings from the performance-based seismic design of a building with typical residential multi-unit layout. The lateral-force-resisting system of the building is ordinary shear walls system with a code exception of height limit. In order to allow the exception, the serviceability and the stability of the ordinary shear wall structure need to be evaluated to confirm that it has the equivalent performance as the one designed under the Korean Building Code 2009. The structure was evaluated whether it satisfied its performance objectives to withstand Service Level and Maximum Considered Earthquake.
Since the 1980s, the number of large space buildings in Korea has consistently been increasing due to large scale international competitions such as the Olympics and the World Cup, demands for environmental improvement, and development of structural systems. Due to these reasons, this paper conducted a comparative analysis on terrorism risk factors of large space structure and skyscrapers in Korea. The results suggest that the total risk level of high-rise and large space structure was "medium level risk" and that the terrorism risk level for large space structure was as high as that for high-rise buildings. As it relates to the risk levels depending on scenarios, terrorism risks to large space structure were higher than high-rise buildings in the "internal explosion" and "internal intrusion" categories. And the results of analyzing explosion-related scenarios except for CBR suggest that terrorism risks to large space structure were highest when it comes to Internal-Explosive followed by Internal-Intrusion and Explosive-Zone I; and the results showed a regular pattern. On the other hand, in the case of high-rise buildings, terrorism risks were highest in Internal-Explosive followed by Explosive-Zone I and Explosive-Zone II; and the results showed an irregular pattern.
Response spectra of a building are made with a SDOF system taking into account a first mode shape, even though higher modes may affect on the dynamic responses of a high-rise building. A soft soil layer under a building also affects on the responses of a building. In this study, seismic responses of a MDOF system were investigated to examine the effects of higher modes on the response of a tall building by comparing them with those of a SDOF system including the kinematic interaction effect. Study was performed using a pseudo 3D finite element program with seven bedrock earthquake records downloaded from the PEER database. Effects of higher modes on the seismic responses of a tall building were investigated for base shear force and base moment of a MDOF system including story shear forces and story moments. Study results show that higher modes of a MDOF system contribute to a reduction of base shear force up to 1/4-1/5 of KBC and base moment. The effect of higher modes is more significant on the base shear force than on the base moment. Maximum story shear force and moment occurred at the top part of a building rather than at a base in the cases of tall buildings differently from short buildings, and higher modes of a tall building affected on the base forces making them almost constant at the base. A soft soil layer also affects some on the base shear force of a high-rise building independently on the soft soil type, but a soft soil effect is prominent on the base moment.
Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.
Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.