The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
본 연구에서는 철근콘크리트 모멘트골조의 보-힌지 붕괴 기구를 유도하기 위한 유전자알고리즘 기반의 최적내진설계기법을 제시 한다. 제안하는 기법은 두 가지의 목적함수을 사용한다. 첫 번째는 구조물의 비용을 최소화하는 것이고, 두 번째는 구조물의 에너지소 산능력을 최대화하는 것이다. 제약조건은 기둥과 보의 강도조건, 기둥-보 휨강도비 최소 조건, 기둥의 소성힌지 발생 방지조건 등이 사용된다. 부재의 강도 평가를 위해 선형정적해석이 수행되고, 에너지소산능력과 소성힌지 발생여부를 평가하기 위해 비선형정적해 석이 수행된다. 제안하는 기법은 4층 예제 구조물에 적용되었으며, 보-힌지 붕괴 기구를 유도하는 설계안이 얻어지는 것을 확인하였 다. 획득된 설계안의 기둥-보 휨강도비를 분석한 결과, 그 값은 기존 내진 기준에서 제시하는 값보다 큰 것으로 나타났다. 보-힌지 붕괴 모드를 유도하기 위해서는 보다 더 강화된 전략이 필요하다.
본 연구에서는 철근콘크리트 모멘트골조의 보-힌지 붕괴 기구를 유도하기 위한 유전자알고리즘 기반의 최적내진설계기법을 제시 한다. 제안하는 기법은 두 가지의 목적함수을 사용한다. 첫 번째는 구조물의 비용을 최소화하는 것이고, 두 번째는 구조물의 에너지소 산능력을 최대화하는 것이다. 제약조건은 기둥과 보의 강도조건, 기둥-보 휨강도비 최소 조건, 기둥의 소성힌지 발생 방지조건 등이 사용된다. 부재의 강도 평가를 위해 선형정적해석이 수행되고, 에너지소산능력과 소성힌지 발생여부를 평가하기 위해 비선형정적해 석이 수행된다. 제안하는 기법은 4층 예제 구조물에 적용되었으며, 보-힌지 붕괴 기구를 유도하는 설계안이 얻어지는 것을 확인하였 다. 획득된 설계안의 기둥-보 휨강도비를 분석한 결과, 그 값은 기존 내진 기준에서 제시하는 값보다 큰 것으로 나타났다. 보-힌지 붕괴 모드를 유도하기 위해서는 보다 더 강화된 전략이 필요하다.
이 연구는 다방향성 바잘트 섬유 시트로 보강한 철근콘크리트 보의 보강방법에 따른 전단거동을 실험을 통해 확인하 였다. 실험변수는 보강방법(무보강, 45도 90도 U형)과 보강겹수(0, 1 2겹)를 변수로 두었으며 전단강도실험결과 바잘트섬유시트 를 90도로 1겹 보강하였을 때 최대 11% 이상의 보강성능을 확인하였다. 또한, 유효변형률을 검토한 결과 섬유양이 증가함에 따 라 유효변형률이 감소함을 확인하였다.
본 논문은 FRP 그리드로 보강된 콘크리트 보의 휨 성능을 예측하기 위한 해석적 연구결과를 제시한다. FRP 그리드 로 보강된 콘크리트 보의 휨 성능 예측을 위해 상용구조해석 프로그램인 LS-DYNA를 이용하여 유한요소해석이 수행되었다. 유 한요소해석 시 콘크리트와 FRP 그리드 간의 본드-슬립을 고려하였으며, 콘크리트와 FRP 그리드의 구속조건은 BEAM_IN_SOLID 모델이 적용되었다. 이후, 국내 여러 연구자들에 의해 수행된 실험 결과의 재현해석을 통해 제안된 유한요소해석 모델의 정확성 이 검증되었다. 최대하중, 최대하중 시의 변위 실험값에 대한 해석값의 비는 각각 0.990, 0.924, 표준편차 각각 0.056, 0.087로 제 안된 해석모델은 FRP 그리드로 보강된 콘크리트 보의 휨 성능을 잘 예측할 수 있는 것으로 나타났다. 제안된 유한해석모델을 이용하여 콘크리트 보의 인장재로 철근이 아닌 CFRP그리드를 적용하기 위한 매개변수해석이 수행되었으며, 콘크리트 압축강도, FRP그리드의 겹 수, FRP그리드의 유효깊이는 CFRP그리드로 보강된 콘크리트 부재의 휨성능에 중요한 인자임을 확인하였다.
본 연구는 콘크리트구조기준(2012)을 적용한 RC보와 ACI 440.1R-15 (2015)를 적용한 FRP 콘크리트를 비교, 분석하였다. 파라미터 변수로 콘크리트의 폭과 높이, FRP의 탄성계수 그리고 보강량 4가지로 설정하여 연구를 수행하였다. 파라미터 연구 결과 보강량비가 상대적으로 적을수록, FRP의 탄성계수가 클수록 RC 대비 FRP 콘크리트의 휨성능이 우수하게 나타났다. 탄성계수가 40GPa이하인 유리섬유는 보강으로 효과가 없으며, 120GPa이상인 탄소섬유는 보강으로 효과가 있는 것으로 분석되었다. 따라서, 보강량이 상대적으로 적을 경우에 탄소 보강재(CFRP) 콘크리트는 RC 대비 경쟁력이 있을 것으로 판단된다.
현재 우리나라에서 설계 및 시공되는 대부분의 철근콘크리트 벽식구조 공동주택은 상부벽체-하부골조 시스템으로 구성되어 있으며 서로 다른 상하부 구조시스템의 결합을 위해 전이보를 이용한다. 상부의 하중을 하부의 기둥 부재에 효율적으로 전달하기 위해 전 이보가 큰 강성을 지녀야하고 이로 인해 부재의 춤이 커져 많은 물량의 투입되고 전반적인 경제성이 떨어지게 된다. 이러한 문제점을 해결하기 위해 기둥을 벽체요소로 대체하고 일반적인 콘크리트 전이보에 비해 규모가 작은 경계보를 수평 구조요소로 활용한 새로운 경계보-벽체 시스템을 제안한다. 제안된 시스템의 축하중에 대한 성능 평가를 위해 3차원 비선형 유한요소해석을 수행하였다. 주요 설계변수로 상하부벽체 길이비, 경계보 부재의 전단보강근 간격, 하부벽체로 연속되는 상부벽체 수직근의 꺾임 비율, 슬래브 길이를 설정하고 제안된 시스템의 성능에 얼마나 기여하는지 분석하였다.
FRP 시트(Sheet)를 활용한 보강 공법은 제작 과정에서의 간편함과 시공의 용이성으로 현장에서 다수 적용되고 있으며, 기존 연구자들은 FRP 시트로 보강한 철근콘크리트의 휨강도를 예측하기 위한 연구를 진행하였다. 그러나 이는 주로 탄소 섬유와 유리 섬유에 한정되어 있었다. 이 연구에서는 바잘트 섬유시트의 역학적 성질을 파악하기 위하여 물성 시험을 수행하였으며, 바잘트 섬유시트로 보강한 철근콘크리트 보의 휨실험을 수행하였다. 또한 그 결과 값을 비교 분석하여 기존 연구를 바탕 으로 바잘트 섬유 시트로 보강한 철근콘크리트 보의 휨모멘트 예측식을 제안하였다. 강도설계법, ACI440.2R (2017) 그리고 Park et al. (2005)의 예측값을 검토한 결과, 강도설계법은 실험값과 예측값의 비가 0.88로 나타났으며, ACI440.2R (2017) 설계식은 0.92, Park et al. (2005)은 0.97로 나타나 기존의 해석 방법은 휨모멘트를 과대평가하는 것으로 나타났다. 본 연구의 제안식은 실험값과 예측값의 비가 1.00으로 나타나 휨모멘트를 안전측으로 예측하는 것으로 나타났다.
한본 연구에서는, 철근콘크리트 보 구조물의 동결융해에 따른 장기거동특성 및 최종 파괴형태를 비교 분석하고자 하였다. 철근콘크리트 보 시험체와 재료 시험체를 제작하여, 동결융해 챔버를 이용하여 동결과 융해를 반복적으로 수행하였다. 동결융해를 위하여 기존의 시험법을 참고하여 철근콘크리트 구조물에 대한 시험을 수행 하였다. 동결융해에 따른 콘크리트의 재 료특성 변화와 철근콘크리트 보 구조물의 거동특성 변화를 통하여 동결융해에 대한 영향을 평가하였다. 제안된 동결융해 시험법을 통하여 콘크리트 공시체의 압축강도가 약 19%감소하였다. 철근콘크리트 보 시험체의 경우, 콘크리트의 표면 강도가 동결 융해에 의하여 감소되어 사인장 균열이 발생하여, 재료적 강도 감소에 의한 구조물의 성능이 감소함을 확인하였다. 또한, 사인장 균열이 발생한 동결융해 시험체의 에너지 소산능력이 동결융해를 거치지 않은 시험체와 비교하여 적게 발생하였다.
This paper discusses the influence of transverse reinforcement spacing and support width of concrete wide beam on shear performance. In order to evaluate the shear performance, a total of thirteen specimens were constructed and tested. The transverse reinforcement spacing, the number of legs and support width were considered as variables. From the test results, the shear strength equation of concrete wide beam is proposed for prediction of shear strength of concrete wide beam to consider the transverse reinforcement spacing and support width. It is shown that the proposed equation is able to predict shear strength reasonably well for concrete wide beam.
When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically.
Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T
he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
최근에 요소망의 재구성이 불필요하고 균열의 가시화에 강점을 가지는 확장유한요소법(XFEM)을 이용한 균열 해석이 많이 연구되고 있지만 주로 단일재료로 이루어진 부재의 해석에 집중되어 있다. 본 논문에서는 복합재료 부재인 철근콘크리트보의 다중균열 해석에 확장유한요소법을 적용하며 그 적용성과 타당성을 살펴보았다. 확장유한요소해석 기능이 탑재된 상용해석프로그램인 ABAQUS를 사용하여 균열해석을 수행하였으며 그 결과를 실험결과와 비교하였다. 확장유한요소법에서 인접요소에 동시에 균열이 발생할 경우 균열의 불연속성이 나타나지 않은 부가자유도 잠김 현상을 발견하였고 이에 대한 원인과 그 해결방안을 제시하였다. 또한 실험결과와 유사한 다중균열 발생을 위한 모델링 기법도 제시하였다. 확장유한요소법을 이용한 해석결과는 실험결과와 유사한 균열 양상 및 균열 간격을 보여 주었으며 하중-변위 관계에 있어서도 실험에 근접한 결과를 보여 주었다.
This study proposed proposes a retrofitting method using an H‐beam frame to improve the seismic performance of non‐seismic designed reinforced concrete frames. To evaluate the seismic performance with the H‐beam frames, a cyclic lateral load test was performed and the experimental result was compared with the bared frame, and a masonry infilled RC frame. The results was were analyzed regarding aspects of the load‐displacement hysteresis behavior, effective stiffness, displacement ductility, and cumulative energy dissipation. AlsoIn addition, it was possible to prove both an increase of in the maximum load capacity, effective stiffness, and energy dissipation capacity using the H‐beam frame.
본 연구는 아라미드 섬유 보강 폴리머(Aramid Fiber Reinforced Polymers, 이하 AFRP)rebar로 보강된 콘크리트 깊은보의 전단강도를 평가하기 위하여 전단경간비, 보강비, 유효깊이, 주근을 변수로 총 8본의 시험체에 대한 전단 실험을 수행하였다. ACI 318-08의 스트럿-타이 모델(이하 STM)을 이용한 전단강도와 아치작용을 고려한 제안식에 의한 전단강도를 비교-평가하였으며, 그 결과 AFRP rebar로 보강한 경우, Steel rebar로 보강한 경우보다 전단강도가 증가하는 것으로 나타났다. 전단강도 산정에 있어 ACI 318-08 STM을 이용한 해석이 상대적으로 정확했으며, 실험결과를 토대로 스트럿의 크기효과를 고려한 유효압축강도 산정 모델을 제안하였다. 이를 본 실험에 적용시킨 결과 기존 기준 및 제안식을 이용한 전단강도 산정방법보다 합리적인 결과를 얻을 수 있었다.
본 연구는 철근콘크리트 내부 보-기둥 접합부의 전단거동 예측에 관한 비선형 모델을 제안한 것이다. 보-기둥 접합부 패널존에서의 전단거동 모델을 위하여 면내전단 예측을 위한 연화트러스모델 이론을 수정한 이론을 적용하였다. 이로부터 접합부에서의 평형조건에 의한 등가 모멘트 및 회전 관계를 이용하여 접합부에서의 전단변형 관계를 접합부의 회전스프링의 특성관계로 변환하여 고려토록 하였다. 소개된 해석모델을 축력 및 전단을 받는 내부 철근콘크리트 보-기둥 접합부의 실험과 비교하였으며, 제시된 모델은 접합부에서의 전단력 뿐만 아니라 전단변형의 예측에도 유효한 것으로 판단되었다.
본 논문에서는 철근콘크리트 모멘트 골조의 보-기둥 접합부에 대한 비탄성 회전 능력의 성능을 조사한 연구 결과를 하고 있다. 총 91개의 보-기둥 접합부 실험체에 대해 상세히 조사되었으며, 그 중 28개의 실험체는 ACI 318-02의 상세 요구에 기초하여 특수 모멘트 골조 접합부로서 분류되었다. AISC-97 내진 기준에서 철골 모멘트 골조 접합부를 위해 정의된 허용기준이 분류된 철근콘크리트 모멘트 골조의 접합부에 대해 평가하기 위해서 사용되었다. 특수 모멘트 골조 접합부에 대한 설계 상세를 만족하는 28개의 실험체 중 27개의 특수 모멘트 골조 접합부가 충분한 강도를 가지고 있었으며, 급격한 강도 감소 없이 0.03 rad.의 소성 회전에 대해 연성 거동을 발휘할 수 있음을 보여 주었다. 접합부의 전단 강도, 기둥과 보에 대한 휨 강도 비율, 접합부내에서의 횡방향 철근비 등에 대한 제한이 보-기둥 접합부의 만족스런 내진 성능을 보여주는데 중요한 역할을 하였다.
본 논문에서는 지진하중을 받는 내부 및 외부 철근콘크리트 보-기둥 접합부의 강도 및 연성능력을 평가하였다. 접합부에 인접한 보에 소성힌지가 발생한 이후 접합부가 파괴할 경우 접합부 내력은 보의 소성힌지의 영향을 받아 감소하게 된다. 보에 소성힌지가 발생하면 보의 부재축방향 변형률은 급격하게 증가하게 되며, 증가된 부재축방향 변형률은 접합부의 변형에 영향을 주어 접합부의 강도를 저감시킨다. 이 논문에서는 보에 소성힌지가 발생하기 이전에 파괴하는 접합부의 내력과 보에 소성힌지가 발생한 이후에 파괴하는 접합부의 연성능력을 접합부의 변형능력 및 스트럿의 강도저감을 이용하여 평가하였다. 제시한 평가법은 52개의 접합부 실험체를 이용하여 검증하였다.
본 논문에서는 강도를 향상시키기 위하여 탄소섬유쉬트를 압축하여 제작된 탄소섬유 판재을 이용하여 철근 콘크리트 보의 휨내력 향상과 이력거동에 미치는 영향을 규명하기 위하여 실험을 수행하였다. 실험의 주된 변수는 탄소섬유판재의 단면의 크기, 보강전에 철근콘크리트 보의 손상정도이다. 특히 보의 손상정도는 보가 과하중에 의해 손상을 받은 경우를 대상으로 하고 있으며 손상정도는 보의 최대 휨 내력의 30%, 60%, 100%로 하고 있으며 비교를 위하여 손상받지 않은 보도 실험하였다. 얻어진 결론은 탄소섬유판으로 보강한 경우는 보강하지 않은 보에 비해 강도는 상승하나 최대하중점에서의 변형은 감소하고 있으며, 연성에 있어서는 대등한 값을 나타내고 있다.