The operating parameters considered in this study include evaporating and condensing temperature, degree of subcooling and degree of superheating. in R744-R717 cascade refrigeration system and R744 two-stage compression refrigeration system with the range of low temperature -50℃∼-30℃. The coefficient of performance(COP) of R744-R717 cascade refrigeration system is about 16∼20% greater than that of R744 two-stage compression refrigeration system in the range of evaporation temperature of -50℃∼-30℃. R744 two-stage compression refrigeration system is unstable because its coefficient of performance changes significantly depending on the evaporating temperature and total compression work, and compression efficiency decreases. In this case, not efficient for long-term use. Whereas R744-R717 R744-R717 is a cascade refrigeration system using eco-friendly refrigerants. And this system is a high-efficiency refrigeration system that performs well even under various operating conditions. This is why it can be configured by selecting a refrigerant suitable for the high temperature side and the low temperature side.
PURPOSES : In this study, heating concrete is developed using heating artificial binder, which is more conductive and less expensive than ordinary Portland cement, and the heating effect is verified through laboratory tests and numerical analysis. METHODS : Based on the test results, the range of heat influence of the Heating concrete is calculated through numerical analysis. As a result of the laboratory test, the temperature rises to 58℃ after 10 minutes when heat generation started at the outdoor temperature of 12℃ and the initial temperature of the concrete specimen of 19.1℃. RESULTS : The heating effect is up to 50 cm in width and 90 cm in height centered on the heating concrete through numerical analysis to analyze the influence range of the Heating concrete based on the laboratory test results. However, when the distance from the heating concrete is greater than about 20 cm, the influence becomes very small, and the rate of temperature decrease drops significantly. CONCLUSIONS : From the test and numerical analysis, it can be used as an eco-friendly heating material suitable for concrete pavements.
In this paper, cycle performance analysis of two-stage compression two-stage expansion refrigeration system using eco-friendly refrigerants is presented to offer the basic design data for the operating parameters of the system. Eco-friendly refrigerant R600a(Isobutane) for freon refrigerant R22 were used working fluids in this study. The coefficient of performance(COP) of R600a is about 5% greater than that of R22 two-stage compression refrigeration system in the range of evaporation temperature –30℃∼-60℃. The coefficient of performance of two-stage compression and two-stage expansion refrigeration system decreases with the increasing condensation temperature and superheating degree but increases with the increasing evaporation temperature, subcooling degree and mass flow rate ration of intercooler.
본 연구는 고속 스핀에코 기법의 T2 강조영상 획득에 있어 온도 상승을 최적화하기 위한 에코 개수(echo train length, ETL) 25를 기반으로 재자화 펄스의 범위에 따른 온도 변화와 이에 따른 신호대잡음비(signal to noise ratio, SNR) 분석을 통한 합리적인 영상 파라미터를 제시하고자 하였다. 온도 변화측정은 수소원자 공명주파수(proton resonance frequency shift. PRF) 기법을 활용했으며, 재자화 펄스의 각도(flip angle, FA)에 따른 온도 상승을 측정하였다. 온도 변화는 재자화 펄스 90도 인가 시에 약 0.202±0.023°C로 증가했으며, 이는 최소 FA인 60도(약 0.196±0.024°C)와 가장 유사하게 나타났다. 또한, 그 영상의 SNR은 FA 120도과 150도에 비해 FA 90도에서 약간 감소하는 경향이 나타났지만(약 12.5%), FA 180도와 비교하여 큰 차이는 발생하지 않았다 (FA 90도=349.66±3.68; FA 180도=357.68±3.21). 이 결과들은 고속스핀에코 기법에서 ETL 25를 사용한 빠른 영상획득 시간을 기반으로 합리적인 영상신호와 재자화 펄스에 의한 최소 온도 상승을 나타내며, 이는 인체 MR 안전기준을 충분히 보장하는데 기여할 수 있다. 특히, ETL 25와 결합된 90도 FA 사용은 가속화된 영상획득 시간, 합당한 T2 영상의 SNR, 그리고 최적의 인체 온도 증가를 위한 고속스핀에코 기법에서의 최적화된 영상 파라미터가 될 수 있을 것으로 사료된다.
Background: There have been many studies on self-myofascial release (SMR) stretching, but there are few comparative studies on the effects of massages using a release ball, which is a type of the SMR method.
Objective: To investigate the immediate effects of release ball massage and self- stretching on proprioceptive sensory, hamstring’s temperature, range of motion (ROM) muscle strength,.
Design: Crossover study.
Methods: Thirty women in 20’s at S University in Busan voluntarily participated in the study. Participants were random to release ball group (n=15) or selfstretching group (n=15). Both groups performed 3 sets of exercises, stretching for 30 seconds and resting for 15 seconds in each position. The proprioceptive sensory, temperature of the hamstring muscle, ROM, and strength were measured before exercise, 5 minutes after exercise, and 30 minutes after exercise.
Results: Release ball group showed significant differences in muscle length and temperature over time (p<.05). The comparison between two group over time showed significant differences in muscle length, temperature, and muscle strength (p<.05).
Conclusions: These results demonstrate that release ball massage and selfstretching are beneficial for improving hamstring's temperature, ROM and muscle strength.
This study is a development of measuring instrument capable of measuring the temperature measurement at a temperature of between 0 ℃ and 1600 ℃ at a high temperature of the high temperature. This development technique develops a measuring device capable of measuring two different temperature measurements by combining two different temperature measurements ranging from one measurement module to the hot temperature to the high temperature. Also, it develops in a vacuum or high pressure state.
2011-2015년 동안 한국 중부 태안과 청주 강내의 배경 관측지점에서 측정한 PM10, PM2.5 질량 농도를 분석하 였다. 황사 사례를 제외한 PM10 질량 농도의 계절변동에서 겨울-봄 동안 높은 농도는 서풍 기류에 의한 영향이 반영 되고 있으며, 여름에는 북태평양 기단과 잦은 강수로 낮은 수준을 보이고 있었다. 따라서, 일평균 PM10 질량 농도 81μg m-3 (미세먼지 예보 ‘약간 나쁨’ 이상) 이상의 사례도 겨울-봄 동안에 발생이 많으며, 특히 중국 동부 배출원에 가까 운 태안에서 더 많은 사례가 발생하고 있었다. 인위적으로 발생한 연무는 입경 2.5 μm 미만 입자의 구성 비율이 높다. 천리안 위성의 밝기온도차 분석에서 대기와 입자가 작은 연무는 −0.5 o K 이상에서 관측된다. 2011-2015년 동안 태안과 청주 강내에서 관측한 연무 사례일의 PM10 질량 농도와 NOAA 19 위성 밝기온도차를 분석하였다. PM10 질량 농도 는 200 μg m−3 보다 낮지만, PM2.5/PM10 질량 농도비는 0.4보다 높고 밝기온도차는 −0.3-0.5 o K 범위에 분포하고 있었 다. 그러나, PM10 질량 농도 190 μg m−3 이상인 황사 사례의 밝기온도차는 PM2.5/PM10 질량 농도비가 0.4보다 낮고, 밝기온도차는 −0.7 o K 이하의 범위에 분포하고 있었다. 이러한 연무의 밝기온도차 경계값 범위를 적용한 결과는 MODIS AOD, OMI AI의 에어로졸 분포 범위와 일치하였다.
The measuring equipment capable of thermo measuring of wide range thermo range(0℃ ~ 160 0℃) will be developed in a high temperature and high pressure state. The developed technology is a combination of one measuring two different temperatures measured in the measuring to a high temperature as possible at a low temperature from thermocouple module(thermocouple) to develop an integrated measuring device capable of measuring the broadband. Also, to develop two or more guard module to ensure the water-tightness and durability of the device to develop in a vacuum or high pressure is applied to the one-piece measuring device.
In this study, changes in daily temperature range were investigated using daily maximum and minimum temperatures of Busan and Daegu for last 81 years (1934-2014), and also characteristics of daily temperature range and seasonal fluctuations by urbanization were examined. First, elapsing changes showed a lower decreasing trend in Busan (0.32℃) than Daegu (1.2 8℃) for last 81 years. Daily temperature range showed the highest rise in winter in both Busan and Daegu. Second, daily temperature range due to urbanization showed that Busan had a pronounced decreasing trend before urbanization meanwhile Daegu showed the same trend after urbanization. On seasonal changes, the results of Busan showed a decreasing trend in summer before urbanization, and in autumn after urbanization. For Daegu, the results showed a decreasing trend in spring before urbanization, and in winter after urbanization. Seasonal fluctuations of Busan showed little difference in the pre and post-urbanization, except in winter and summer. There was large difference in daily temperature range in winter after urbanization, and in summer before the urbanization. The results in Daegu showed that there was decreasing trend of daily temperature range in all seasons after urbanization.
터널에서 외기에 접촉되는 부분은 입, 출구부와 환기구가 있으며 이러한 부위의 열화와 그 진행속도는 외기의 영향을 받지 않는 구간과는 다른 차이를 보여준다. 실제로 터널에서 외기에 접촉되는 부분뿐만 아니라 외기의 영향을 받는 구간은 일반적인 구간과는 다른 관점에서 접근해야 할 필요가 있고 보수나 보강공법 적용시에도 우선 고려가 되어야 한다. 그럼에도 불구하고 터널의 유지관리시, 점검 및 정밀안전진단시 외부온도의 영향을 받는 구간의 결함 및 열화는 그 범위가 광범위함에도 불구하고 구조체의 안전성에 미치는 영향이 미소하다는 이유로 소홀히 되고 있는 실정이며 일시적인 계절영향, 온도 변화요인에 의한 것으로 판단하여 특별한 관리가 되지 않고 있는 실정이다.
이에 본 논문은 외부온도, 기온의 터널내 영향범위를 산출하기 위해 2개소의 도심지 터널에 대해서 적외선 열화상카메라를 활용하여 터널내의 외부온도 영향범위를 결정하고 그 영향범위에서 발생되는 콘크리트라이닝 또는 콘크리트 구조체의 결함 및 열화원인을 분석하고 유지관리시 중점을 두고 시행해야 할 사항을 제시하였다.