Composites of carbon fiber-reinforced silicon carbide (Cf/SiC) with ultra-high temperature ceramics (UHTCs) exhibit superior resistance to oxidation and ablation under high temperatures. Components in large-scale applications often have complex geometries, making it crucial to understand the oxidation and ablation behaviors of curved and non-uniform surfaces. In this study, a Cf/SiC-ZrB2 composite was fabricated into a 300 mm cylindrical shape using filament winding and liquid silicon infiltration processes. The resulting specimens exhibited a uniform microstructure, with SiC and ZrB2 crystals evenly distributed across the top and bottom surfaces, demonstrating the feasibility of producing large-scale composites. The specimens underwent an oxyacetylene torch test at 2,100 K for 5 min to assess their ablation and oxidation performance. The results revealed significant variation in the oxide layer due to the non-flat surface, with the layer thickness gradually decreasing as the oblique angle was reduced. Additionally, the presence of high-melting-point ZrO2 in the oxide layer near the torch center was attributed to the migration and solidification of molten SiO2. This suggests that large and complex Cf/SiC incorporating UHTCs can effectively form a protective oxide layer, even under conditions where SiO2 displacement occurs. The findings underscore the importance of integrating geometric considerations into the design of ultra-high temperature ceramic composites to achieve the thermal and ablation resistance required for advanced high-temperature applications.
In this study, we evaluated wound healing following the use of 3% topical povidone ointment in dogs with minor wounds and evaluated it as a new wound treatment applicable to veterinary medicine. Twenty-six dogs that had suffered minor wounds such as abrasions, punctures, and incised wound within 8 hours were recruited, and all treatments were performed with the consent of their owners. Vitality, behavioral symptoms, and dermal symptoms due to wounds were evaluated between the povidone ointment group (n=18) and the control group (chlorhexidine group, n=8). As a result of evaluating changes in vitality and behavior, the povidone ointment group showed improvement to 1.94 (±2.53), 0.61 (±1.34), and 0.39 (±1.24) while the chlorhexidine group showed improvement to 2.00 (±1.6), 0.87 (±0.99), and 0.86 (±0.99) on days 0, 3, and 7 respectively, showing similar improvement in symptoms between the two groups (p>0.05). When observing wound symptoms, most of the swelling and inflammation improved within 3 days. The averages for the chlorhexidine group on days 0, 3, and 7 were 4.88 (±2.85), 2.88 (±2.64), and 2.38 (±2.39), and for the povidone ointment group, 5.55 (±3.22), 3.83 (±3.07), and 1.38 (±1.61), respectively. The wound healing effect of the povidone ointment group was similar to that of the chlorhexidine group (p>0.05). Through this study, we believe that topical povidone ointment can be applied to various wounds by replacing chlorhexidine.
Roridin E, a constituent of Podostroma cornu-damae, has excellent medicinal properties and exhibits powerful anticancer effects. However, being a poisonous mushroom, P. cornu-damae is difficult to find in its natural environment. Therefore, only a limited amount of roridin E is isolated from P. cornu-damae. We isolated roridin E from mycelial culture medium of P. cornu-damae and examined its effects on five breast cancer cell lines. The purity of the isolated roridin E was 96%. It exhibited anticancer effects on all five breast cancer cell lines, with an IC50 of at least 0.0006 mg/L. To the best of our knowledge, this is the first report on the investigation of effects of roridin E isolated from the mycelium of P. cornu-damae mushrooms on five breast cancer cell lines. However, safety issues should be investigated and addressed in future studies before roridin E is used in clinical settings.
This case report describes satisfactory correction of deep and large canine corneal ulcerations by application of bidirectional corneo-conjunctival transposition (CCT). A 12-year-old spayed female Maltese dog with a large corneal descemetocele, perforation, and blepharospasm of the right eye was referred to Chungbuk National University Veterinary Teaching Hospital. More than half of the thickness of the cornea was damaged, and the ulcer was progressive. On ophthalmic examination, menace response and dazzle reflex were absent. No corneal melting was observed. As the patient had large and deep corneal ulcers, traditional one-sided CCT was not sufficient to cover the wound lesion. To increase corneal transparency after recovery, we decided to perform bidirectional CCT from 12 o’ clock on the dorsal side to 7 o’ clock on the ventral side. The dog was medicated with topical eye drops, ofloxacin, atropine, and moxifloxacin before surgery. Debridement with a diamond burr was then performed around the descemetocele. Five weeks after surgery, the dazzle reflex was restored as the blood vessel receded from the cornea to the conjunctiva. Eight weeks after surgery, corneal transparency and corneal stability were gradually restored, but not completely. Bidirectional CCT provides structural support and helps corneal wound healing in large canine corneal ulceration.
본 연구에서는 폴리비닐알콜(PVA)와 폴리프로필렌글리콜(PPG)기반의 창상피복용 수분산 폴리우레탄수지를 합성하였으며, 시료의 물리적 특성을 필름 시료와 피혁(Full-Grain) 표면에 코팅을 하여 물리적 특성 변화를 연구하였다. 인장강도의 경우 PVA가장 적게 반응된 PUD-PA1 2.00 kgf/㎟ 으로 가장 높은 저항성을 보였으며. 마찬가지로 연실율은 PVA가장 적게 반응된 PUD-PA1가 554%로 높게 측정되었다. 내마모성 측정 결과 PVA 반응이 증가함에 따라 표면의 강도나 낮게 36.77 ㎎.loss로 감소 됨을 알수 있었다.
In this study, the polyurethane resin was synthesized by applying PTMG and DMBA of different composition ratios for the synthesis of water-dispersible polyurethane used in wound coating resin. The varying properties of the synthesized water-dispersible polyurethane were measured through tensile strength, elongation, and abrasion resistance analysis. As for the tensile strength measurement result according to the PTMG content, the sample with the highest reaction molar ratio was measured as 1.08 kgf/mm2 and the elongation was measured as 520%. As for the tensile strength result according to the DMBA content, the sample with the highest reaction molar ratio was measured as 0.51 kgf/mm2, and the elongation was measured as 435%. The degree of surface destruction by the abrasion resistance measurement was visually confirmed through SEM.
This study investigated the regenerative and healing effect of spirulina on corneal epithelial injury by acid burn in zebrafish. Corneal epithelium of adult zebrafish was evaluated at 0, 12, 24, 48 h after acid burn injury with or without immersion with 0.02 and 0.04 mg/mL of spirulina water extract. The pathological changes of corneal epithelium were assessed by light microscopy. Gene and protein expressions of proliferating cell nuclear antigen (PCNA), matrix metalloproteinase (MMP) 9 and MMP13 were determined by immunohistochemistry or real-time PCR. Corneal epithelium was denuded totally after acid burn and gradually regenerated. PCNA-positive cells significantly increased in spirulina treated group. MMP9 and MMP13 mRNA transcripts were significantly decreased in spirulina treated groups. In conclusion, spirulina has regenerative and healing properties by increased keratocyte proliferation, and inhibited extracellular matrix degradation during the regeneration process of corneal epithelial injury by acid burn in zebrafish.
주입구멍의 크기와 수관 상태에 따른 약액의 수간주입 속도를 알아보고자 주입구멍의 지름을 5mm와 10mm로 하고 수관을 온전, 절반 제거, 1/4씩 두 곳 제거 등 세 수준으로 구분하여 식용색소 적색3호 수용액을 수간주입하고 일정 시간별로 주입량을 측정하였다. 수간주입 4시간 뒤에 대부분의 느티나무에서 약액이 30% 이상 흡수된 상태였으며, 7시간 후에서는 7그루에서 모든 약액이 흡수된 것을 확인하였다. 48시간 후에는 처리 조건과 방법에 관계없이 한 그루를 제외한 모든 개체에서 주입액이 완전흡수되었다. 주입구멍의 크기나 수관의 상태 등은 수간주입 속도와 통계적 유의성이 없었다. 주간에서 움트는 잔가지의 잎들은 수간주입 후 24시간에 붉은색을 나타내기 시작하였으며, 48시간 후에는 수관의 잎들도 엽육조직이 붉게 변하여 수관도 붉은 색을 보였다. 수관이 변색된 나무의 수도 처리 내용 간에 통계적 유의차가 없었다. 줄기 단면 관찰에서도 주입구멍의 크기나 수관 상태 간에 적색주입액의 분포 차이가 없었다. 본 연구의 결과로부터 주입구멍의 크기나 수관의 엽량은 수간주입의 효율에 영향을 미치지 않음이 확인되었다. 따라서 큰 상처를 남기는 지름 10mm 주입구멍보다는 지름 5mm 주입구멍을 사용 하는 것이 나무의 자가치유를 도와주는 올바른 수간주입법이라고 할 수 있다.
폴리사카이드 기반 나노파이버는 신체 독성이 없고 수분 흡수성이 우수하다. 폴리사카이드 소재를 나노파이버로 적층시키면 표면적의 증가로 인하여 혈액흡습량이 증가하고 피부 알러지를 최소화 할 수 있으며 공기 투과성이 증가하여 상처 치료 소재로 적합하다. 폴리사카이드 나노파이버의 약한 물리적 성질을 보완하기 위하여 흡습성과 기계적 성질이 우수한 폴리아마이드 계열의 나노파이버를 지지층으로 사용하여 국소 상처 치료용 혈액지혈 패치를 개발하였다.
Astaxanthin(Ast) is considered a powerful antioxidant. However, the efficacy of Ast is limited due to its poor water solubility and stability. To enhance the properties of Ast, 2-hydroxypropyl-γ-cyclodextrin(HPγ-CyD) can be used through complexation. In this study, we investigated the wound healing ability of Ast/HP-γCyD(Ast/HP-γ-CyD) complex in sacran-based hydrogel. HP-γ-CyD played an important role to increase the elastic modulus of the sacran-based hydrogel with high swelling ability. Unusually, the Ast/HP-γ-CyD complex in sacran-based hydrogel provided the highest wound healing ability in mice. These results suggest that the Ast/HP-γ-CyD complex in sacran-based hydrogel has the potential for use as a new transdermal therapeutic system to promote the wound-healing process
본 논문은 윌리엄 켄트리지(William Kentridge, 1955- )의 ≪프로젝션을 위한 드로잉 Drawings for Projection≫ 연작 (1989-2003)에 관한 연구이다.
켄트리지가 태어난 남아프리카 공화국은 과거에 ‘아파르트헤이트(apartheid)’라는 극단적인 인종차별정책을 시행했던 나라로, 켄트리지의 작업의 주제에는 이로 인한 인한 트라우마가 각인되어 있다. 트라우마는 반복강박을 수반하고, 이러한 반복강박은 현대 예술가들에게 있어서는 아카이브(archive) 형태로 나타나게 된다. 켄트리지 역시 자신의 ≪프로젝션을 위한 드로잉≫ 연작에서 아파르트헤이트라는 트라우마를 팰림프세스트라는 표현 방식을 빌어 ‘아카이브 열병’으로 표현하였다. 켄트리지는 자신의 연작인 ≪프 로젝션을 위한 드로잉≫에서 여러 겹의 흔적들이 쌓여 이루어진 팰림프세스트를 통해 과거의 기억들이 중첩된 장면들을 보여준다. 이러한 중첩은 기억과 망각 사이에 놓여 있는 여전히 현재형인 작업으로, 이는 우리가 어떻게 트라우마를 기억해야 하는지를 제시해주고 있다.
또한 켄트리지의 ≪프로젝션을 위한 드로잉≫ 연작에 나타나는 주된 기법인 팰림프세스트는 이전의 흔적들을 오버래핑(overlapping)시키며 기억을 가시화한다. 그렇기에 그 작업은 과거에도 현재에도 속하지 않으며, 동시에 과거에도 현재에도 속하게 된다. 이는 공간적 몽타주(spatial montage)의 속성으로, 공간적 몽타주는 하나의 시공간 안에 존재론적으로 조화 불가능한 것을 공존하게 하는 것이다. 과거의 흔적들을 간직하고 있 는 켄트리지의 팰림프세스트는 각기 다른 형태들의 공존을 허락하고 과거와 현재의 공존처럼 존재론적으로 가능하지 않은 장면들을 결합시킨다. 켄트리지는 존재론적으로 불가능하고 하나의 주제에 대해 각기 다른 관점을 유지하는 공간적 몽타주를 통해 과거의 역사로 편입되는 완결된 내러티브로서의 트라우마가 아닌 지금 이 순간의 트라우마를 보여주고 있는 것이다.
그러므로 결국, 팰림프세스트라는 매체 표현 방식을 통하여 아카이브 열병과 함께 공간적 몽타주를 보여주고 있는 켄트리지의 ≪프로젝션을 위한 드로잉≫ 연작은 남아프리카 공화국의 아파르트헤이트라는 트라우마를 치유하기 위한 과정이었다고 볼 수 있다.
고강도, 내약품성, 무독성, 내연소성의 장점을 가지고 있는 PVdF (polyvinylidene fluoride) 나노섬유로 기공이 0.4 μm 평막을 제조한 후, 부직포와 평막으로 나권형 모듈을 제작하였다. 용존유기물의 흡착 제거를 위한 입상 활성탄(GAC, granular activated carbon) 흡착 컬럼과 자체 제작한 나권형 모듈로 혼성 수처리 공정을 구성하였다. 카올린과 휴믹산으로 조 제한 모사 용액을 대상으로, 처리수를 재순환하는 경우와 배출하는 경우 각각 GAC 충진량의 영향을 알아보았다. 여과실험 후 물 역세를 하여 회복률과 여과저항을 계산하였다. 또한, 탁도와 UV254 흡광도를 측정하여 GAC의 흡착 효과를 고찰하였 다. 그 결과, 처리수를 재순환하는 경우와 배출하는 경우 모두 탁도 처리율에는 GAC 충진량의 영향이 없었다, 하지만 GAC 의 UV254 흡광도 처리율이 처리수를 순환하는 경우 0.7~3.6%이었는데, 처리수를 배출하는 경우 3.2-5.7%로 증가하였다. 처리 수를 순환하는 경우 GAC의 충진량이 증가함에 따라, 가역적 여과저항(Rr)과 비가역적 여과저항(Rir)은 감소하는 경향을 보였 다. 그러나 총여과저항(Rt)은 거의 일정하였고, 물 역세 회복률(Rb)은 다소 증가하는 경향을 보였다.
The objective of the present study was to examine the effects of β-glucan originating from Aureobasidium on full-thickness skin wound healing in diabetic C57BL/KsJ-db/db mouse models. In the diabetic C57BL/KsJ-db/db model, test articles were topically applied twice a day for 20 days starting from 1 day after wounding. The results were compared to that of MadecassolTM ointment (madecassol; 1% Centella asiatica extracts) topically applied at a concentration of 100 mg/kg. Treatment with β-glucan resulted in significant (p<0.01 or p<0.05) and dose-dependent decreases in wound size compared with that of vehicle control showing increased wound size (WS, %). In addition, 50% contraction time (CT50) was dramatically and dose-dependently reduced, and inflammatory cells in granulation tissues of the wound area were significantly (p<0.01 or p<0.05) and dose-dependently reduced compared with that of vehicle control showing increased numbers of micro-vessels and fibroblasts as well as re-epithelialization. In the madecassol group, similar changes in inflammatory cells and fibroblasts with re-epithelialization were also observed, but madecassol did not influence angiogenesis. No meaningful changes in body weight were detected in all tested groups compared with the vehicle control. Therefore, these data suggest that β-glucan has a beneficial effect on diabetic delayed skin wound healing and may be useful to manage incurable skin wounds in diabetic animals.
기공 0.4 μm PVDF 나노섬유 정밀여과 나권형 모듈과 GAC 컬럼의 혼성공정에서 모사용액을 순환 없이 선형유속 0.013 m/s, TMP를 0.5 bar 조건으로 GAC 충진량을 변화시키면서 실험하였다. 또한 동일한 혼성공정에서 모사용액을 순환시키면서 선형유속 0.026 m/s, TMP 1.5 bar의 조건으로 GAC 충진량의 영향을 고찰하였다. 탁도와 UV254 흡광도(DOM) 처리율을 비교하였는데, 탁도 처리율에는 영향이 없었으나, GAC의 충진량이 많을수록 DOM 이 증가하였다. 하지만 TMP와 유속이 높은 조건인 순환이 있는 실험에서 GAC에 의한 DOM 처리율이 더 낮은 이유는 순환으로 인해 모사용액 농도가 낮아졌기 때문인 것으로 판단된다.