        781.
        2013.04 서비스 종료(열람 제한)
        In this study, shear assessment equation of reinforced concrete interior beam-column joints without shear reinforcement using high ductile fiber reinforced mortar based on the test results was proposed. Suggested equation was proposed to modify Hegger's seismic design equation. It was reflected the effect of high ductile fiber incorporated
        782.
        2013.04 서비스 종료(열람 제한)
        In this study, experimental research was carried out to evaluate and improve the constructability and structural performance of high strength R/C interior beam-column joints regions, with or without the shear reinforcement, using high ductile fiber-reinforced mortar. Specimens designed by retrofitting the interior beam-column joint regions of existing reinforced concrete building showed a stable mode of failure and an increase in load-carrying capacity due to the effect of enhancing dispersion of crack control at the time of initial loading and bridging of fiber from retrofitting new high ductile materials during testing.
        783.
        2013.04 서비스 종료(열람 제한)
        For coupled shear walls, coupling beams are the first line of dissipation under earthquakes. So coupling beams are important energy dissipation component. When coupling beams have little depth-to-span ratio, routine coupling beams have less capacity of energy dissipation.There are less design methods for coupling beams with depth-to-span less than 2. In this paper a specimen with steel plate reinforcement coupling beam was designed and analyzed by means of FEM software ABAQUS.
        784.
        2013.04 서비스 종료(열람 제한)
        The purpose of this study was to evaluate the seismic performance of high-performance steel. For this study, the hysteretic behavior and deformation shape of steel beam-to-column connections with SM570TMC was investigated using non-linear finite element analysis. The non-linear finite element analysis was carried out using ANSYS. The displacement analysis of steel beam-to-column connections was conducted according to the qualifying procedures of current korean building code(KBC2009).
        785.
        2013.04 서비스 종료(열람 제한)
        To evaluate the ductility of high strength steel beam-to-column connections, Cycle loading connection test was conducted targeting HSA800 steel being developed in Korea and parameter is connection details. According to the study, The non-scallop detail and improved horizontal rib reinforcement detail used in this study enhanced deformation capacity of high strength steel connections which have brittle tendency by stress relaxation.
        786.
        2013.04 서비스 종료(열람 제한)
        Connection details were developed for the composite column using high strength steel angles. Load-carrying capacity, deformation capacity, and load transfer mechanism of three beam-to-column joint specimens were evaluated under cyclic load tests. In the experiments, mega columns were used for the application in high-rise buildings
        787.
        2013.04 서비스 종료(열람 제한)
        Under cyclic loading, the shear capacity of reinforced concrete (RC) beam-column connections is significantly decreased by the joint bond-slip and shear cracking as deformation increases. In the present study, Joint shear strength model on the basis of bond-slip was developed to evaluate deformability at the joint shear failure.
        788.
        2013.04 서비스 종료(열람 제한)
        In this study, experimental research was carried out to evaluate the structural performance of the reinforced concrete beam retrofitted by strengthening methods(embedded FRP rod of hexagon, metal fittings) in existing reinforced concrete buildings. Test results showed that the maximum load carrying capacity of retrofitted specimens(BCR, BCR-AC1, BCR-AC2) were increased by 55%, 47%, and 52% respectively in comparison with the standard specimen BSS.
        789.
        2013.04 서비스 종료(열람 제한)
        In this study, experimental research was carried out to study the high strength RC exterior beam-column joints regions, without the shear reinforcement, using high ductile fiber-reinforced mortar. Test results showed that specimen BCJNSP1.0 were increased th maximum load-carrying capacity and showed stable hysteresis behavior and satisfactory crack pattern in comparison with th specimen BCJNS without shear reinforcement in the beam-column joint region.
        790.
        2013.04 서비스 종료(열람 제한)
        In this study, experimental research was carried out to study the high strength RC exterior beam-column joints regions, without the shear reinforcement, using high ductile fiber-reinforced mortar. Specimens designed by retrofitting the exterior beam-column joint regions of existing reinforced concrete building showed a stable mode of failure and an increase in shear strength capacity due to the effect of enhancing dispersion of crack control at the time of initial loading and bridging of fiber from retrofitting new high ductile materials during testing.
        791.
        2013.04 서비스 종료(열람 제한)
        FRP has higher design tensile strength than steel bar and outstanding characteristics such as light-weight, non-corrosion, and lower conductivity. And, current researchers evaluated flexural performances of flexural members using FRP and suggested the development length and splice length by using bonding failure test. This Researchers has the main purpose to examine the quality of bonding failure in the lap spliced FRP and deformed bar. Variables in this test with total 208 specimens planned are re-bar location, embedment length, covering depth, re-bar diameter. And, this study describes the result of our review on the bonding strength of the lap-spliced FRP and the deformed bar located at the bottom.
        792.
        2013.04 서비스 종료(열람 제한)
        Amorphous metal fibers can improve the brittleness of concrete and enhance the shear and tensile strength of reinforced concrete (RC) members. A series of experimental studies RC composite beams with amorphous metal fiber composites were conducted, and it was shown that the RC beam with amorphous metal fiber composites could give improved flexural responses to compare with the reinforced concrete beam.
        794.
        2013.04 서비스 종료(열람 제한)
        In this study, the flexural test were carried out on a total eighteen reinforced concrete beams with different steel connection. From the results, reinforced concrete of not spliced showed higher ultimate loads and cracking loads than other specimens. Also the ultimate load of reinforced of parallel(tapered) threaded coupler is almost equal to that of lap spliced.
        795.
        2013.04 서비스 종료(열람 제한)
        In this paper, a moment resisting precast concrete beam-to-column connection is proposed for high seismic zones using bolt type connection. An experimental study was carried out to investigate the behavior of the proposed connection subjected to cyclic loading
        796.
        2013.04 서비스 종료(열람 제한)
        This paper describes the flexural performance of concrete and strain-hardening cement based composite (SHCC) beams reinforced with normal and high-strength steel bar to evaluate the effect of reinforcing bar strength and cement composite type. The present investigation shows the potential of high-strength structure materials used of high-strength reinforcing bars with SHCC. And superior mitigation of crack-damage is observed reinforced SHCC beams than reinforced concrete beams
        797.
        2013.04 서비스 종료(열람 제한)
        The objective of this study is to investigate the influence of PVA Fiber on flexural yielding coupling beam. Test variable of this study is material type of coupling beam. Test results showed that coupling beam with PVA material experienced multiple micro craks.
        798.
        2013.04 서비스 종료(열람 제한)
        The acoustic emission technique (AE) was implemented to assess long-term performance of concrete beams (reinforced with glass fiber reinforced polymers (GFRP) and steel bars) exposed to an aggressive combination of high temperature and humidity. This study presents the results and discussions of an experimental study concerning AE characteristics of long-term behaviors of concrete beams reinforced with GFRP and steel bars after accelerated
        799.
        2013.04 서비스 종료(열람 제한)
        In this study, it was developed eco-friendly geopolymer concrete using ground granulated blast furnace slag and alkali activator(water glass, sodium hydroxides). Also, it was evaluated the flexure capacity of the RC beams using geopolymer concrete. The eco-friendly concrete using geopolymer encouraged alkali activation reaction has rapid hardening speed and showed possibility as a high strength concrete. Also, the RC beams applied this showed similar movement and destroy tendency with RC used previous cement
        800.
        2013.04 서비스 종료(열람 제한)
        Bond characteristic between lightweight concrete and helically deformed GFRP bar was investigated in this study. Three main parameters were considered in experimental investigation: type of rebar, concrete type, and compressive strength of lightweight concrete. As an experimental result, it could be known that bond strength of the helically deformed GFRP bar in the lightweight concrete was 0.49 times bond strength of steel reinforcement in normal concrete