This study is a preliminary investigation into a method for updating analytical models using actual vibration measurement data to improve the reliability of the seismic performance evaluations. The research was conducted on 26 models with various parameters, aiming to develop an optimal analytical model that closely matches the natural frequencies of the actual building. By identifying the dynamic characteristics of the target building through vibration measurements taken just before the demolition of the structure, the natural frequency analysis results of the analytical models were compared to the measured data. Based on this comparison, an optimized method for adjusting the parameters of the analytical models was derived. Throughout the analysis, various parameters were adjusted, and the eigenvalue analysis results were corrected by comparing them with vibration measurements. Among the comparative analytical models, the model with the lowest error rate was selected. The results showed that, in all cases, the analytical model with a concrete compressive strength of 16 MPa (based on actual measurements), pin boundary conditions, and an idealized strip footing cross-section had the closest match to the actual building's natural frequencies, with an average error of less than 8%.
이 연구는 해조류에서 추출된 알긴산을 혼입하여 라텍스 콘크리트의 경제성을 개선하고, X선 회절 분석(XRD)을 통해 미세구조 변화 를 분석하는 것을 목표로 한다. 기존 라텍스 콘크리트(LMC)의 높은 비용을 보완하기 위해 라텍스 혼입량을 줄이고 알긴산을 추가한 콘크리트를 제작하여 재령 4시간, 7일, 28일에 따른 미세구조 및 강도 발현 특성을 분석하였다. XRD 분석 결과, 재령 증가에 따라 Ettringite는 감소하고 일부 Monosulfate(AFm 상)로 변환되었으며, Ye’elimite는 C-S-H 및 Monosulfate로 변환되면서 초기 강도 발현이 감 소하고 장기 강도가 증가하는 경향을 나타내었다. 압축강도 실험에서는 재령 28일 기준 case 2의 강도가 기존 LMC와 유사한 수준을 나타내었다. 알긴산 혼입 라텍스 콘크리트에서 Larnite(C2S) 증가와 Hatrurite(C3S) 감소가 관찰되었다. 이는 알긴산이 C3S의 조기 수화 를 촉진하고 후반 수화 반응을 활성화시켜 장기 강도 발현에 긍정적인 영향을 미친 것으로 판단된다. 결과적으로, 알긴산 혼입 라텍스 콘크리트는 초기 강도보다는 장기 강도 발현에 유리하며, 최적 혼입량 설정과 내구성 평가를 위한 추가 연구가 필요할 것으로 판단된 다.
이 연구는 산업 부산물을 활용한 무시멘트 숏크리트의 압축강도를 분석하고, 기존 숏크리트와 비교하여 최적 배합설계를 도출하였다. KS F 2403 및 KS F 2405에 따라 시험을 진행한 결과, 일반 숏크리트 및 무시멘트 숏크리트 모두 숏크리트 품질기준에서 제시하고 있 는 압축강도 기준을 만족하였다. 무시멘트 숏크리트 W/B 0.45 변수의 경우 초기강도가 가장 높게 나타났다. 28일 강도는 W/B 0.45 및 W/B 0.50 변수가 일반 숏크리트 대비 동등하거나 우수한 성능을 나타냈다.이러한 친환경 무시멘트 숏크리트 현장 적용을 위해서는 급 결제를 혼입한 배합에 대한 추가 검토가 필요할 것으로 판단되고, 또한 내구성능에 대한 추가적인 실험적 연구가 필요할 것으로 판단 된다.
이 연구는 라텍스 콘크리트(LMC)의 대체재로 해조류에서 추출한 알긴산을 활용한 콘크리트를 개발하고, 이에 따른 압축 강도 및 미 세구조 변화를 분석하였다. LMC는 공극 구조 개선으로 내구성과 강도가 향상되지만, 높은 원자재 비용이 단점이다. 이를 보완하기 위 해 라텍스 대신 알긴산을 혼합한 콘크리트를 제작하고, 주사전자현미경(SEM) 분석 및 압축 강도 실험을 수행하였다. 재령 4시간 및 1일 후의 압축 강도와 10000배율 SEM 분석을 진행하였다. 알긴산 0.05% 혼입 시 가장 높은 강도를 보였으며, 0.2% 혼 입 시 강도가 감소하였다. SEM 분석에서는 LMC가 균일한 표면과 미세한 입자 분포를 보인 반면, 알긴산 혼합 콘크리트는 섬유 및 막대 구조가 형성되었으며, 알긴산 함량이 증가할수록 기공이 증가하여 강도발현이 저하되었다. 재령이 증가하면서 C-S-H 구조가 조 밀해지고 결합력이 향상되어 강도가 증가하는 양상이 관찰되었다. 보다 정확한 결과를 얻기 위해서는 에너지 분산형 X선 분광법 (Energy Dispersive Spectroscopy, EDS)등 추가적인 실험이 필요할 것으로 사료된다.
Salmonella enterica는 세계적으로 가장 널리 알려진 식 중독균이다. Salmonella enterica Enteritidis MFDS1022168 은 인천보건환경연구원에서 계란에서 분리된 균주로, 이 균 주가 지니고 있는 병원성에 대한 genome 수준의 메커니즘을 이해하기 위하여 whole genome sequencing을 진행 하여 유전체를 분석하였다. PacBio Sequel 장비를 이용하 여 유전체염기서열 분석을 진행한 결과 invA를 비롯한 여 러 종류의 병원성유전자를 갖고 있는 것으로 확인됐다. 이 에 따라 해당 균주의 독성을 파악하기 위해 유전체분석을 진행하였다. 유전자 총 수 예측 결과, 4,776개의 CDSs, 84 개의 tRNA, 22개의 rRNA를 보유한 것으로 나타났다.
수전해 시스템에서 제어되지 않은 수소 크로스오버(hydrogen crossover)는 효율 저하 및 폭발 위험성 등을 야기시 키는 위험 요인이다. 수전해 공정에서 양이온교환막(cation exchange membrane, CEM)은 완전히 수화된 상태로 운전되기 때 문에 이중상(two-phase) 물질로 취급하는 것이 중요하다. 본 총설에서는 수소 크로스오버의 특성 평가 중 발생할 수 있는 주 요 기술적 문제를 요약하였다. 특히, pressure decay method (PDM)는 수소 크로스오버를 정확하게 측정하기 위한 기법으로 평가되며, 막 내부 구조 분석에도 활용할 수 있다. 또한, 수소 크로스오버를 평가하는 데 있어 permeability (즉, 고유 물질 특 성) 차원의 고유한 한계를 논의하고, 공정 안전성을 위해 flux 기반(즉, 공정 파라미터)으로의 전환 필요성을 강조한다. 추가 적으로, 막-촉매 계면에서의 과포화(supersaturation) 현상이 크로스오버에 미치는 영향에 대한 연구 필요성을 강조한다.
This study sought to improve the accuracy of estimating national emissions of volatile organic compounds (VOCs) from consumer solvent products (CSPs) by updating emission factors and category-specific activity data. The classification of the CSPs, which was originally proposed by the U.S. Environmental Protection Agency, was reorganized to reflect domestic consumption patterns in Korea. VOC contents, product sales, and atmospheric evaporation rates of the CSPs were analyzed for subcategories including personal care products, household products, and automotive aftermarket products to update their emission factors. Additionally, the category-specific activity data, previously based on only population statistics, were newly applied to count the characteristics of each classification, such as the number of households and the number of registered automobiles. The updated emission factors were calculated to be 1.90 kg/capita·yr for personal care products, 4.37 kg/household·yr for household products, and 2.36 kg/car·yr for automotive products. An evaluation of uncertainties revealed the limitation in the product classification, the shortage of sales data, and the lack of information on VOC contents depending on the product forms (liquid, solid, and aerosol). This study highlighted the necessity of developing detailed classification systems and standardized VOC content measurement methods, ultimately contributing to more accurate and practical assessments of VOC emissions from the CSPs.
Tunnel fires have significant social and economic impacts, causing extensive damage to concrete and steel reinforcements at high temperatures. Despite international advancements in fire-resistant designs, the safety measures for tunnel fires in South Korea remain insufficient. This study aimed to evaluate the fire resistance of fiber-reinforced concrete incorporating fire-resistant fibers with a focus on preventing spalling and enhancing structural safety. These findings are expected to contribute to the development of fire-resistant tunnel-design standards. Concrete mixtures with compressive strengths of 27 MPa were prepared according to highway construction material standards. Fiberreinforced concrete samples were produced with fire-resistant fiber dosages of 0.0, 0.6, 0.8, and 1.0 kg per cubic meter. Fresh concrete tests, including air content (KS F 2421) and slump (KS F 2402) tests, were conducted along with compressive strength tests (KS F 2405) on the hardened concrete. The fire resistance was assessed using an electric furnace to simulate the fire curve conditions specified in the Road Tunnel Fire Safety Guidelines based on KS F 2257. Increasing the fiber content led to a slight reduction in slump, likely owing to fiber agglomeration, with minimal effect on workability within the tested range. The air content exhibited negligible variation, indicating that there was no major impact on the air-void system. The compressive strength before the fire resistance test fluctuated but consistently met the design target of 27 MPa. The compressive strength after the fire resistance test across all samples decreased to approximately 2.0 MPa. The fiber-reinforced concrete exhibited reduced internal temperatures compared to the control, which was attributed to heat transfer disruption and the formation of micropores by the fibers. In this study, fiber-reinforced concrete demonstrated improved thermal resistance under fire conditions with minimal impact on the workability and air content within the tested range. Although the compressive strength before the fire resistance test remained adequate, the sharp decline in the post-fire strength highlights the need for further optimization. These findings emphasize the potential of fiber-reinforced concrete as a cost-effective solution for enhancing tunnel fire resistance, thereby supporting the development of safer and more resilient infrastructures.
The addition of fiber sto concrete matrix has been a norm to enhance the mechanical strength of concrete. However, the use ot synthetic fibers (artificial fibers) is rampant compared to natural fibers due to a low mechanical strength of some natural fibers. The study added cellulose fiber made from jute at 0.2%, 0.25, and 0.3% of cement weight to concrete matrix to determine their influence on the early strength development. It was observed that compressive strength and flexural strength increases as the proportion of fiber added to the concrete increased. Further observation showed that the compressive strength had its optimum point at 0.3% fiber addition. However, the optimum point of the flexural strength lied at 0.25% fiber addition. It was concluded that cellulose fiber is capable of enhancing the mechanical strengths of concrete matrix.
이 연구에서는 해양폐기물인 해조류에서 추출된 알긴산을 혼입하여 모르타르의 압축강도 특성을 분석하였다. 알긴산은 해양폐기물 중 해조류의 성분 중 하나로 라텍스와 비슷한 성분을 띄고 있으며, 방수성 성질이 있어 포장용 콘크리트에 활용 시 콘크리트의 수명 을 연장하고 파손 방지에 도움이 된다. 따라서 이 연구에서는 기존에 널리 사용되고 있는 라텍스 콘크리트에 알긴산을 혼입한 라텍스 콘크리트 개발의 일환으로 알긴산 혼입 라텍스 모르타르의 역학적 특성에 대한 실험적 연구를 수행하였다. 실험결과, 알긴산 혼입량 증가에 따른 응결은 빨라지는 경향을 나타내었으며, 압축강도는 저하하는 경향을 나타내었다.
도로터널의 연장과 대형화로 인해 화재 발생 시 터널 구조물의 안전확보가 중요한 과제가 되고 있다. 터널에서 화재가 발생할 경우, 콘크리트 라이닝이 고온에 노출되면서 강도저하 및 폭렬에 의한 구조적 손상을 초래할 수 있으며, 이를 방지하기 위해 다양한 내화공 법이 연구되고 있다. 이 연구에서는 폭렬을 억제하기 위한 내화공법으로 고온 노출에 따른 섬유혼입콘크리트의 온도전이 특성에 대한 실험적 연구를 수행하였다. 온도전이 특성 실험은 200×200×200mm 크기의 큐브 형태의 시험체에 0.6, 0.8, 1.0kg/m3의 섬유를 혼입하여 시험체를 제작하였다. 섬유혼입콘크리트 내부온도를 측정하기 위하여 표면에서부터 20mm 간격으로 100mm까지 총 6개의 K타입 열전 대를 설치하였고, 전기 내화로를 사용하여 RWS 화재곡선을 모사하여 시험체를 가열하였다. 실험결과, 섬유를 혼입한 콘크리트는 섬유 를 혼입하지 않은 Control 변수에 비해 내부온도가 낮아지는 경향을 보였다. 이는 고온에서 내화섬유가 용융되면서 콘크리트 내부의 수증기압을 감소시켜 효과적으로 억제된 것으로 보인다. 특히 내화섬유 0.8kg/m3을 혼입한 경우 60mm 이상에서 효과적으로 콘크리트 내부 온도 상승을 억제한 것으로 나타났으며, 폭렬에 의한 구조적 손상을 방지하기 위한 적정 수준의 내화섬유 혼입량은 필요할 것으 로 판단된다. 그러나 많은 양의 섬유 혼입은 고온에 따른 섬유 용융으로 인해 내부에 다량의 공극이 형성되어 폭렬 억제에는 효과적 일 수 있으나, 다량으로 형성된 공극에 따른 온도 확산이 더 빠르게 진행되어 적절한 피복두께 확보가 필요할 것으로 판단된다. 따라 서 도로터널 내화 지침(국토교통부, 2021)의 콘크리트(380℃) 및 철근(250℃)의 한계온도 이내를 만족하기 위해서는 피복두께는 최소 100mm 이상을 확보해야 할 것으로 판단된다. 이는 터널 구조물의 내화성능을 개선하기 위한 기준을 제시하며, 향후 도로터널의 안전 성을 강화하기 위해 섬유혼입량과 철근 피복두께 간의 상관관계에 대한 추가적인 실험 및 해석적 검토가 필요할 것으로 판단된다.