검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 323

        282.
        2022.04 KCI 등재 서비스 종료(열람 제한)
        Electrical Conductivity (EC) or Total Dissolved Solids (TDS) has been often used to evaluate the water quality in some water education program for children and youth. This study attempted to find out whether EC (or TDS) can be used as a water pollution criteria in water education program. To clarify it, we used the water analysis data of July 2019 and January 2020 from Water Environment Information System. Data from 332 points in Han-river were used to investigate correlation between the parameters, such as BOD, COD, TN, TP vs EC. Correlation(r) for all data of BOD vs. EC was 0.347 for July 2019 and 0.483 for January 2020. No correlation was observed for BOD Ia and BOD Ib for July 2019 (r=-0.041, -0.030, respectively) and BOD Ia for January 2020 (r=0.041). Better correlation for all data of COD vs. EC was obtained (r=0.543 for July 2019 and r=0.610 for January 2020). However, no correlation was observed for COD Ia for January 2020. High vlaue of EC or TDS does not always mean water pollution, especially for clean water environment. Thus, EC (or TDS) alone can not be used as a water pollution criteria.
        283.
        2021.07 KCI 등재 서비스 종료(열람 제한)
        Moving average precipitation provides periodic precipitation patterns by solving precipitation irregularities. However, due to uncertain moving average periods, excessive data smoothing occurs, which limit the possibility to analyze groundwater levels in the short term. Nonetheless, groundwater level fluctuation can compensate these limitations as it can calculate appropriately for unit time and verify the effect of precipitation penetrated into groundwater in a short time period. In this study, the characteristics of groundwater level were evaluated using groundwater level fluctuation to compensate for limitations of groundwater level analysis using moving average precipitation. In addition, the groundwater quality was investigated using the electrical conductivity fluctuation. The study site was Hyogyo-ri, Yesan-si, Chungcheongnam-do. Four observation wells and an automated weather system were used. The correlation between groundwater level fluctuation and precipitation (Case 1) and the correlation between groundwater level and moving average precipitation (Case 3) were compared. In the analysis for 1 hour data, the correlation coefficient of Case 1 was higher than that of Case 3, and in the analysis for 1 day data, the correlation coefficient of Case 3 was higher than that of Case 1.
        284.
        2019.12 KCI 등재 서비스 종료(열람 제한)
        We used numerical models to reliably analyze the groundwater flow and hydraulic conductivity on Jeju Island. To increase reliability, improvements were made to model application factors such as hydraulic watershed classification, groundwater recharge calculation by precipitation, hydraulic conduction calculation using the pilot point method, and expansion of the observed groundwater level. Analysis of groundwater flow showed that the model-calculated water level was similar to the observed value. However, the Seogwi and West Jeju watersheds showed large differences in groundwater level. These areas need to be analyzed by segmenting the distribution of the hydraulic conductivity. Analyzing the groundwater flow in a sub watershed showed that groundwater flow was similar to values from equipotential lines; therefore, the reliability of the analysis results could be improved. Estimation of hydraulic conductivity distribution according to the results of the groundwater flow simulation for all areas of Jeju Island showed hydraulic conductivity > 100 m/d in the coastal area and 1 45 m/d in the upstream area. Notably, hydraulic conductivity was 500 m/d or above in the lowlands of the eastern area, and it was relatively high in some northern and southern areas. Such characteristics were found to be related to distribution of the equipotential lines and type of groundwater occurrence.
        285.
        2019.10 서비스 종료(열람 제한)
        탄산화가 고전도성 시멘트 복합재료의 전기전도도에 미치는 영향에 대해 실험적으로 확인 하였다. 탄소나노튜브(carbon nanotube, CNT)가 혼입된 페이스트형 및 모르타르형 시멘트 복합재료를 설계하였으며, 제조된 시편을 촉진탄산화 환경에 노출 시켰다. 반년간의 노출 후 확인한 결과 시멘트 복합재료의 전기전도도가 급격하게 감소한 것을 확인 할 수 있었다. 이 특성은, 전도성 시멘트 복합재료를 콘크리트용 센서로 사용했을 때, 탄산화에 의해 복합재료의 전기전도도가 변화할 수 있음을 고려해야 한다는 증거임과 동시에, 이 복합재료가 탄산화 센서로 사용될 수도 있다는 것을 의미한다. 본 논문은 본 연구 진의 기존논문 Lee et al.(2019)를 요약한 것이다.
        286.
        2019.10 서비스 종료(열람 제한)
        전기전도도가 높은 시멘트 복합재료에 염소가 침투했을 경우 그 자체의 전기전도도가 어떻게 바꾸었는지를 실험적으로 확인 하였다. 시멘트 복합재료의 전기전도도 확보를 위해 탄소나노튜브(carbon nanotube, CNT) 및 탄소섬유(Carbon fiber)를 사용하였다. 염소의 침투가 시멘트 복합재료에 미치는 영향을 알아보기 위해 1) 염화나트륨을 배합 시 적당량 혼입하는 방법과 2) 염화나트륨 수용액에 전도성 시멘트 복합재료를 함침시키는 두가지 방법을 활용하였다. 실험 결과 염소 침투에 의해 전기전도도가 일부 증가하는 경우와 함께 반대로 감소하는 경우도 동시에 발견되었다. 본 논문은 본 연구진의 기존 논문 Lee et al.(2019)을 요약한 것이다.
        287.
        2019.09 KCI 등재 서비스 종료(열람 제한)
        In this study, the sensitivity analysis of hydraulic conductivity and separation distance (distance between injection well and pumping well) was analyzed by establishing a conceptual model considering the hydrogeologic characteristics of facility agricultural complex in Korea. In the conceptual model, natural characteristics (topography and geology, precipitation, hydraulic conductivity, etc.) and artificial characteristics (separation distance from injection well to pumping well, injection rate and pumping rate, etc.) is entered, and sensitivity analysis was performed 12 scenarios using a combination of hydraulic conductivity (10-1 cm/sec, 10-2 cm/sec, 10-3 cm/sec, 10-4 cm/sec) and separation distance (10 m, 50 m, 100 m). Groundwater drawdown at the monitoring well was increased as the hydraulic conductivity decreased and the separation distance increased. From the regression analysis of groundwater drawdown as a hydraulic conductivity at the same separation distance, it was found that the groundwater level fluctuation of artificial recharge aquifer was dominantly influenced by hydraulic conductivity. In the condition that the hydraulic conductivity of artificial recharge aquifer was 10-2 cm/sec or more, the radius of influence of groundwater level was within 20 m, but In the condition that the hydraulic conductivity is 10-3 cm/sec or less, it is confirmed that the radius of influence of groundwater increases sharply as the separation distance increases.
        288.
        2019.03 KCI 등재 서비스 종료(열람 제한)
        이 연구는 고성능 섬유보강 복합체(HPFRCC)의 전자파 차폐성능을 향상시키기 위한 목적으로 전기전도도, 전자파 차폐능, 역학적 강도를 조사하였다. 강섬유, 제강슬래그 미분말, 카본블랙이 전도성재료소 HPFRCC 배합에 첨가되었다. 또한, MWCNT를 수 분산 시켜 제조된 2% wt. CNT 용액을 사용하였다. 실험 결과, HPFRCC의 전기전도도는 1% 카본블랙이 첨가된 시편을 제외하고는 매우 낮은 특성을 보였다. 시멘트 매트릭스의 미세구조는 시간에 따라 변하였고, 그로 인해 HPFRCC의 전기전도성 네트워크에 부정적인 영향을 끼쳤다. 0.083 S/cm의 전도도를 갖는 HC1 시편의 경우, 수분에 의한 효과를 배제하기 위하여 72시간 60도에서 건조 양생한 후에 측정한 전기전도도가 0.0003 S/cm로 상당히 감소하였다. 전자파 차폐 성능에 가장 중요한 인자는 강섬유인 것으로 나타났으며, 반면 카본블랙과 제강슬래그 미분말의 효과는 미미하였다. 전기전도도와 전자파 차폐능의 상관관계는 이 연구에서는 뚜렸한 경향성을 나타내지는 않았다.
        289.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 해석적 방법을 통하여 내화 재료의 특성을 파악하고 섬유 강화 폴리머로 보강된 철근콘크리트의 보의 적절한 내화설계 방법을 제안하는 것이다. 이를 위해, 내화재료의 가열실험을 실시하고 유한요소해석을 통해 열전도율과 비열을 구하고 또한 고온에서 FRP로 보강된 철근콘크리트 보 실험체에 대한 유한요소 해석을 통해 실험결과와 해석결과를 비교하였다. 이 과정에서 실험과 해석적 접근의 신뢰성을 확인하였다. 최종적으로 FRP로 보강된 철근콘크리트 보의 열적특성을 제안된 해석 방법으로 분석하고 고온으로 감소된 휨내력을 계산하였다. 최종적으로 제안된 방법을 이용하여 FRP로 보강된 부재에서 고온 노출시 열특성을 반영한 부재의 열전도를 파악하고 이를 이용하여 내력을 산정할 수 있는 것으로 나타났다.
        290.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        In a sex offender ecosystem, it is necessary to ensure that rape is applied only to violent breaches of at least sexual self-determination. However, it is doubtful that the Supreme Court may have too broad a range of rape cases in this case. On the contrary, The first and second trial courts seem to be wary of further rape charges. On the basis of this case, it is likely to be the type that corresponds to the sexual compel in the German criminal law. So it would be more appropriate to introduce and punish the sexual compel in legislation if consensus was formed on the need to punish people for forcing sexual behavior. That would also eliminate the need to stretch and punish rape charges. The Supreme Court calls the degree of rape and intimidation the most serious offense and threat. But, it seems that the comprehensive judgment system applies the standards of violence and intimidation of consultation. However, such a comprehensive judgment does not provide a clear standard. Therefore, in this case, the Supreme Court made a different judgment from the first and second trials. However, the main reason why it is difficult to consistently punish sex crimes is because there is a big problem with the current sex criminal law system. As the wrong legal system is filled with diverse legal interpretations, the burden is entirely on citizens. Therefore, it is inevitable that there continue to be disturbance in the ecosystem of sex crimes. The preferred way to fix this mess is for lawmakers to fix the current sex crime system. And the court should try to help citizens form a proper consciousness of norms on sex crimes through a consistent and clear application of the law.
        291.
        2017.09 서비스 종료(열람 제한)
        In this study, it evaluate the electrical conductivity of fiber reinforced cement composite by Fiber type. Hooked-ended steel fiber, Smooth steel fiber and Amorphous metallic fiber were reinforced 2.0 vol.% in cement composites respectively. The electrical conductivity was evaluated by calculating the electrical resistivity of each specimen after measuring the electrical resistance.
        292.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        In this study, groundwater flow was analyzed targeting Dae-jeong watershed, which exhibited the largest variations of groundwater levels at the identical elevation points among the 16 watersheds of Jeju Island. The issues of the methods applied in practice were identified and improvement plans were suggested. This groundwater-flow estimates derived by applying hydraulic conductivity values onto zones of equal topographic ground level were found to be quite different from actual measured groundwater flow. Conversely, groundwater-flow estimates that utilized hydraulic conductivity values applied onto groundwater-level equipotential lines indicated relatively lesser divergences from actual measured groundwater flow. The reliabilities of the two approaches were assessed for 60 randomly selected points on DEM (digital elevation model) maps, The method using hydraulic conductivity values applied onto groundwater-level contours turned out to be the more reliable approach for the Dae-jeong watershed in Jeju Island.
        293.
        2016.12 KCI 등재 서비스 종료(열람 제한)
        본 논문은 한국의 전통적인 커뮤니케이션 장소였던 장시(market)가 구한 말 초기 선교사들의 전도활동의 중요한 토대가 되었음을 밝히고, 장시가 복음의 장소로 변화하는 과정을 탐색하려는 목적에서 집필되었다. 선교사 윌리엄 블레어(William Blair)는 복음 전도지로서 “장터는 사람들을 만나기 좋은 장소이며, 복음을 전하기 안성맞춤인 곳이다”라고 말한 바 있다. 15세 기 중엽에 설치되기 시작하여 17세기에 조선 전역에 확산된 서울 뿐 아니 라 지방 포구를 중심으로 상품 유통의 중요한 발달을 가져왔다. 장시는 조 선 사회의 경제적 활성화를 견인하였을 뿐 아니라 신문물, 신문화의 전파 통로이기도 하였고, 이를 통해 사회 변혁을 이끄는 기능도 하였다. 초기 입국 선교사들은 이러한 장시의 특성을 파악하고 복음 전파의 중 심지로 적극 활용하였다. 로스는 국제 무역 장시였던 만주의 ‘고려문’에서 조선의 상인들을 만나 기독교를 전하고 성경을 번역하였으며, 국경 무역장 시인 의주를 통해 한반도에 복음이 들어오는 데에 큰 역할을 수행하였다. 이후 1885년 언더우드, 아펜젤러 등의 선교사들도 한국의 풍토와 민정을 파악하기 위하여 장시를 방문하였고, 19세기 말에는 개항지의 확대와 더불 어 전국 장터에 속속들이 선교 거점이 마련되었다.이처럼 장시는 조선에서의 선교 활동의 중요한 거점이었다. 기독교가 이 땅에 들어와 우리 민족과 만나 어우러져 숨쉬기 시작한 토대는 바로 조선 시대 소통의 장이었던 장시였던 것이다.
        294.
        2016.04 KCI 등재 서비스 종료(열람 제한)
        An insulating brick was developed and evaluated as a potential recycling Waste Limestone (WL) with Melting Slag (MS). We aimed at analyzing the parameters affecting the insulating brick manufacture to enhance the recyclability of WL. In this study, The thermal conductivity, compressive strength and apparent porosity of prepared brick were measured with the addition of aluminum dross and the molar ratio of the alkali activator. The thermal conductivity, compressive strength and apparent porosity were 0.28 W/mK, 2.41 MPa and 44.72% respectively at a mixing ratio of 9.5 : 0.5wt%, 1.5 M SiO2/Na2O, 3wt% aluminum dross. Thus, it met the standards of insulating fire bricks (KS L 3301).
        295.
        2015.11 서비스 종료(열람 제한)
        용해성 무기전자수용체를 이용하여 호흡하는 황산염환원박테리아는 지반환경에서 다양한 물질의 생화학적 순환에 중요한 역할을 담당한다. 하지만 용해되지 않는 고형전자수용체를 이용하여 전자를 전달하는 황산염환원균은 현재까지 보고된 바 없다. 따라서 본 연구에서는 혐기성미생물로서 대표적인 황산염환원균주 Desulfovibrio desulfuricans 가 고형전자수용체로의 직접적인 전자전달을 위해 나노크기의 필라멘트를 생성하는 것을 확인하였다. 이러한 나노필라멘트는 전기전도도가 높게 나타나(5.81 S·m-1) 이를 이용하여 황산염환원균이 고형전자수용체로 전자를 전달할 수 있음이 입증되었다. 이 같은 기작을 이용하여 황산염환원균은 미생물연료전지(Microbial fuel cell)에서 전기생산을 위한 고체전극으로의 직접적 전자전달을 수행함을 확인하였다. 이러한 결과는 황산염환원균에 의해 용해성 전자수용체의 유효성이 제한될 때, D. desulfuricans 와 같은 황산염환원균이 용해되지 않는 고형전자수용체로의 전자전달을 위한 대체방안으로 전도성 나노규모의 박테리아 부속물생산을 개시함을 의미한다. 따라서 황산염환원균 중 일부는 전자 매개체없이 직접적으로 고형전자수용체로의 전자전달을 수행할 수 있으며, 황산염환원균주에 의한 효과적인 전기생산을 증진시키는 기법으로 MFC 연구에 유용할 것으로 판단된다.
        296.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        Hydraulic conductivity is an important parameter in the analytical model of groundwater. This study analyzed the groundwater movement characteristics by estimating optimal parameters according to hydraulic conductivity input methods with the MODFLOW model which is widely used. It first estimated the optimal parameters by dividing hydraulic conductivity zones by attitude. Next, it estimated optimal parameters by geological characteristic. It analyzed the groundwater movement characteristics by applying the recharge quantity and amount of evapotranspiration of drought periods and flood years with the estimated parameters. As the result was analyzed that there are differences of observation water level values according to hydraulic conductivity input methods but there is no big differences of overall groundwater movement characteristics by hydraulic conductivity input method, the two methods have found to be applicability in analyses of groundwater. So, it is judged that studies on more exact application of hydraulic conductivity and the application methods are needed.
        297.
        2015.02 서비스 종료(열람 제한)
        화재로 인한 건축물 구조부재의 파괴는 추가적인 경제적 손실과 인명피해를 가져오기 때문에 화재에 대한 구조부재의 안전성은 매우 중요하다. 화재에 노출된 철근콘크리트 구조부재의 경우, 부재의 열전도도에 따라 내부 온도가 상승하고 부재의 하중저항강도와 강성이 저하된다. 철근콘크리트 부재의 화재에 대한 구조성능 확보 여부는 일반적으로 표준화재실험을 통하여 입증한다. 콘크리트의 열전도도는 온도에 따라 변하기 때문에 20℃, 100℃, 200℃, 300℃, 400℃, 500℃, 600℃ 700℃, 800℃ 열적 정상상태의 콘크리트 블록을 이용하여 측정한다. 본 연구에서는 철근콘크리트 기둥의 화재에 대한 구조성능 확보 여부를 확인하기 위한 표준화재실험으로부터 얻어지는 열적 비정상상태의 일차원 온도분포 시간이력으로부터 콘크리트의 열전도도를 추출하는 방법을 제안하였다. 표준화재실험으로부터, 기둥의 표면에서 중심까지의 온도분포 시간이력을 얻었다. 콘크리트의 온도에 따른 열전도도 k(T)=α{(T/120)²-T/60+200}에 대하여 다양한 α값으로 온도분포 시간이력을 수치해석 하였고, 실험결과와 가장 오차가 작게 발생하는 α값을 결정하였다. 결정된 콘크리트의 온도에 따른 열전도도는 20℃, 100℃, 200℃, 300℃, 400℃, 500℃, 600℃ 700℃, 800℃ 열적 정상상태의 콘크리트 블록에서 측정된 콘크리트의 열전도도와 비교하였고, 제안된 수치해석에 의한 열전도도 산출방법이 유효함을 입증하였다.
        298.
        2014.10 서비스 종료(열람 제한)
        In this study, an analysis model with circular arc on the plane is chosen as a representative section of the steel box girder. The steel box girder has thin-walled cross section. When working load is increased in the outer sector, the behavior of the negative reaction and overturning moment are shown up. Curved bridge has a central angle from about 4 to 26 degree. Negative reaction and overturning moment are analyzed according to increase of a central angle from 4 to 26 degree as well as shape factor.
        299.
        2014.04 서비스 종료(열람 제한)
        This study is for development of high thermal conductive concrete and its mechanical and thermal properties are evaluated. Magnetite aggregates with volume ratio of 42.9%(max.) and steel powder of 1.5% are replaced with normal aggregate and their are evaluated. Several models for thermal conduction like ACI, DEMM, and MEM are compared with the test results and they are verified to reasonably predict the thermal conductivity with increasing addition of magnetite aggregates and steel powder.
        300.
        2014.04 서비스 종료(열람 제한)
        This paper presents a finite element analysis to evaluate thermal conductivity of FRP (Fiber Reinforced Polymer) retrofit system in reinforced concrete structure. Especially, this paper focused on near-surface-mounted retrofit method; FRP is mounted into the groove after making a groove in concrete. Midias-FEA program was used to analyze the case that the epoxy was covered by various board to resist fire such as, calcium silicate or alumino silicate board. Analysis results give that the prediction of temperature transition from surface is possible by FE analysis and the result can be used to evaluate fire resistance of certain fire proof materials in FRP retrofit system.