검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 419

        321.
        2016.04 서비스 종료(열람 제한)
        The development and verification of seismic performance possible role as moment resisting frames connection is needed because rigidly-connected and assembled lightweight steel frame system is not easy to obtain the seismic performance at the same time.
        322.
        2016.04 서비스 종료(열람 제한)
        In this study, existing wall-type apartment in 1990s is evaluated by KBC2009. Based on structural calculation, seismic performance evaluation is performed with dynamic nonlinear analysis. After that, this building is extended up to three stories in vertical direction. In this study, the seismic performance evaluation results of wall-type apartment can be used in performance-based design of the vertical extension remodeling.
        323.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        횡방향철근은 기둥의 소성힌지구간에 충분한 구속효과, 축방향철근의 좌굴방지와 연성거동을 확보하기 위해 적용된다. 기둥에서 사각형 후프 띠철근과 보강 띠철근의 조립 및 배근방법은 시공이 까다롭고 많은 횡방향철근량이 요구된다. 본 논문에서, 이러한 문제점들을 해 결하기 위하여 장방형 단면과 플레어 기둥의 횡구속을 위한 장방형 후프 띠철근을 사용한 새로운 횡구속 방법이 제안되었다. 개발된 장방형 후 프 띠철근 상세는 장방형 단면과 플레어 기둥의 시공성과 경제성을 향상시켜줄 수 있는 하나의 대안으로서 적용 가능한 것으로 판단된다. 본 연 구의 최종목적은 철근콘크리트 교각의 시공성 향상을 위한 장방형 후프 띠철근 상세의 제시와 실험적 기초자료의 제공과 함께 하중단계별 성 능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠 비, 잔류변형지수, 유효강성 등의 주요 내진성능평가 변수들에 대한 분석결과를 나타내었다.
        324.
        2015.10 서비스 종료(열람 제한)
        This paper describes the effect of steel frame on seismic performance of non-ductile reinforced concrete (RC) frame. To achieve the this objective, RC frames were made based on existing school building constructed in 1980s. Test results indicated that RC frame retrofitted with steel frame was improved the seismic performance than conventional RC frame.
        325.
        2015.10 서비스 종료(열람 제한)
        This paper indicated the seismic performance evaluation of coupling beam designed by ACI 318 11 and SFRC(Steel fiber reinforced concrete). In this study, SFRC coupling beam added steel fiber of 1.5 %. Teste results indicated that coupling beam reinforced by SFRC shown outstanding absorb energy capacity and stiffness degradation than concrete coupling beam by bridge effect of steel fiber.
        327.
        2015.04 서비스 종료(열람 제한)
        Generally, Seismic design has not been applied for the existing('now-using' means) railway tunnel. therefore, In this case study, We introduce a case of seismic performance evaluation for tunnels. It is evaluated by comparing capacity with demand for tunnel linings.
        328.
        2015.04 서비스 종료(열람 제한)
        A seismic performance assessment based on risk assessment is proposed considering risk factors and scenario, and thus the technique provides more practical and reasonable seismic performance assessment and reinforcement for the existing buildings more than ever before.
        329.
        2015.04 서비스 종료(열람 제한)
        In this study, seismic isolation technology to the stainless steel warm integrated water tank structure is suggested and isolation effects on response reduction are studied for the proposed seismic isolation technology. A seismic isolation system is installed on the base of the stainless steel warm integrated water tank. Analysis result, the earthquake loading is greatly reduced and the accelerations of superstructure are greatly reduced.
        330.
        2015.04 서비스 종료(열람 제한)
        The concrete frames are deteriorated by the corrosion of reinforcement bars. To consider the corrosion effect on the seismic performance of concrete frames, the probabilistic approach method such as the Monte Carlo simulation (MCS) is utilized. However, MCS has a weakness that a lot of computation time is required. In this study, the evaluation method for the seismic performance of chloride-corroded reinforced concrete moment frames using multi-cores is presented to reduce the computation time.
        331.
        2015.04 서비스 종료(열람 제한)
        With the increase in the frequency of the seismic activity in the territory of Korean Peninsula, the demand for seismic performance evaluation of existing buildings has appeared as well. In this research, a public building built in 1970s is evaluated by the Korea Infrastructure Safety Corporation guideline. As a result, this existing public building is evaluated to satisfy the life safety (LS) and the collapse prevention(CP) performance level that the KBC2009 demands for.
        332.
        2015.04 서비스 종료(열람 제한)
        The purpose of this study is to apply performance-based seismic design guideline to high-rise shear wall building. According to PEER TBI Guideline, the building is evaluated whether it satisfies the performance objectives which is to be capable of elastic response under Service Level shaking having a return period of 43years and to withstand Maximum Considered Earthquake shaking with prevention collapse.
        333.
        2015.04 서비스 종료(열람 제한)
        In this stydy, experimental research was carried out the hysteretic behavior of reinforced concrete haunched beams such as application with or without haunched. Test results showed that test specimens(FTH) was increased respectively the maximum load carrying capacity by positive 18%, negative 29% in comparison with the specimens(FTG). And the specimens(FTH) showed stable hysteretic behavior compared to the specimen(FTG)
        334.
        2015.04 서비스 종료(열람 제한)
        In this study, four reinforced concrete beam-column joints, replacing recycled materials with hybrid fiber were constructed and tested under monotonic loading. Experimental programs were carried out to improve and evaluate the seismic performance of such test specimens, such as the load-displacement, the failure mode, and the maximum load carrying capacity. All the specimens were modeled in 1/2 scale-down size.
        335.
        2015.04 서비스 종료(열람 제한)
        Connection details for RC column-steel beam (RCS) moment frames were developed to improve the productivity and constructability. To strengthen the beam-column joint, transverse beams, studs, and U-cross ties were used. Four 2/3 scale interior RCS connections were tested under cyclic lateral loading. The specimens generally exhibited good deformation capacity exceeding 4.0% story drift ratio. Ultimately, the specimens failed due to bearing failure of concrete and shear failure of the joint panel.
        336.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve the seismic performance of reinforced concrete exterior beam-column joint regions using replacing recycled coarse aggregate with hybrid fiber (steel fiber+PVA fiber) in existing reinforced concrete building. Therefore it was constructed and tested seven specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of reinforced concrete building, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and bridge of retrofitting hybrid fiber during testing. Specimens BCJGPSR series, designed by the retrofitting of replacing recycled coarse aggregate with hybrid fiber in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.01~1.04 times and its energy dissipation capacity by 1.06~1.29 times in comparison with standard specimen BCJS. Also, specimen BCJGPSR1 were increased its energy dissipation capacity by 1.33~1.65 times in comparison with specimens BCJS, BCJP and BCJGPR series for a displacement ductility of 9.
        337.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        In this study, experimental research was carried out to evaluate and improve the seismic performance of reinforced concrete beam-column joint regions using strengthening materials (CFRP sheet, AFRP sheet, embedded CFRP rod) in existing reinforced concrete structure. Therefore it was constructed and tested seven specimens retrofitting the beam-column joint regions using such retrofitting materials. Specimens, designed by retrofitting the beam-column joint regions of existing reinforced concrete structure, were showed the stable failure mode and increase of load-carrying capacity due to the effect of crack control at the times of initial loading and confinement of retrofitting materials during testing. Specimens LBCJ-CRUS, designed by the retrofitting of CFRP Rod and CFRP Sheet in reinforecd beam-column joint regions were increased its maximum load carrying capacity by 1.54 times and its energy dissipation capacity by 2.36 times in comparison with standard specimen LBCJ for a displacement ductility of 4 and 7. And Specimens LBCJ-CS, LBCJ-AF series were increased its energy dissipation capacity each by 2.04~2.34, 1.63~3.02 times in comparison with standard specimen LBCJ for a displacement ductility of 7.
        338.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        Recently a new damper system with Kogome truss structure was developed and its mechanical properties were verified based on the laboratory test. This paper presents a Kagome truss damper external connection method for seismic strengthening of RC frame structural system. The Kagome external connection method, proposed in this study, consisted of building structure, Kagome damper and support system. The method is capable of reducing earthquake energy on the basis of the dynamic interaction between external support and building structures using Kagome damper. The pseudo-dynamic test, designed using a existing RC frame apartment for pilot application of LH corporation, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and response ductility. Test results revealed that the proposed Kagome damper method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.
        339.
        2015.01 KCI 등재 서비스 종료(열람 제한)
        In this study, a new RCSF (Reinforced Concrete Steel Frame) external connection method is proposed for seismic strengthening of medium-and low-rise reinforced concrete buildings. The RCSF method, proposed in this study, is capable of carrying out the seismic retrofitting construction while residents can live inside structures. The method is one of the strength design approach by retrofit which can easily increase the ultimate lateral load capacity of concrete buildings controlled by shear. The pseudo-dynamic test, designed using a existing school building in Korea, was carried out in order to verify the seismic strengthening effects of the proposed method in terms of the maximum load carrying capacity and ductility. Test results revealed that the proposed RCSF strengthening method installed in RC frame enhanced conspicuously the strength and displacement capacities, and the method can resist markedly under the large scaled earthquake intensity level.
        340.
        2014.10 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the seismic performance of RC frame building which was retrofitted by wing walls. At fitst, the seismic performance evaluation was performed on the deteriorated RC frame building by using capacity spectrum method. And the efficiency of the retrofit by using wing walls was checked from the evaluation of its seismic capacity for various layout. As a results, it was found that the wing wall increased the stiffness and strength of the building.