검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 82

        21.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Soil-foundation-structure interaction (SFSI) is one of the important issues in the seismic design for evaluating the exact behavior of the system. A seismic design of a structure can be more precise and economical, provided that the effect of SFSI is properly taken into account. In this study, a series of the dynamic centrifuge tests were performed to compare the seismic response of the single degree of freedom(SDOF) structure on the various types of the foundation. The shallow and pile foundations were made up of diverse mass and different conjunctive condition, respectively. The test specimen consisted of dry sand deposit, foundation, and SDOF structure in a centrifuge box. Several types of earthquake motions were sequentially applied to the test specimen from weak to strong intensity of them, which is known as a stage test. Results from the centrifuge tests showed that the seismic responses of the SDOF structure on the shallow foundation and disconnected pile foundation decreased by the foundation rocking. On the other hand, those on the connected pile foundation gradually increased with intensity of input motion. The allowable displacement of the foundation under the strong earthquake, the shallow and the disconnected pile foundation, have an advantage in dissipating the earthquake energy for the seismic design.
        4,000원
        22.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 2차원 나노 물질을 응용하여 수처리 막의 성능을 향상시킬 수 있는가에 대한 연구가 활발하다. 그 노력의 한 가운데에 원자 두께를 가지고 있으면서 손쉽게 구할 수 있고 층으로 쌓을 수도 있는 2차원 물질인 그래핀이 자리하고 있다. 이 총설에서 우리는 그래핀으로부터 만들 수 있는 두 가지 막 구조에 관한 기초 물질 전달 현상을 최근 연구 성과를 중심으 로 다룬다. 그 물질 자체로 이미 물질 전달 차단성을 갖는 그래핀에 정확히 제어된 크기의 구멍을 뚫을 수 있다면 아마도 원 자 크기 수준으로 얇은 두께 때문에 그래핀 막은 같은 기공 크기의 어느 막보다도 빠른 궁극적 투과도를 나타낼 것이며, 이 로부터 선택도를 담보할 수 있다면 다양한 막 분리 공정에 적용할 수 있을 것이다. 그 한 예로, 나노미터 이하의 기공을 가정 한 초박막 침투성 그래핀 막에 대한 분자동역학 연구와 몇몇 초기 실험 결과들이 해수담수화 막으로서의 가능성을 보인 점은 주목할 만하다. 그래핀 물질로부터 다른 구성을 가진 막을 설계할 수 있는데, 이 막은 적당히 산화된 그래핀 마이크로 판들을 무작위로 적층함으로써 구현할 수 있다. 그래핀 판 적층 간격을 나노미터 이하로 쉽게 제어할 수 있기 때문에 이 구조 역시 수처리 및 해수담수화 막으로서의 가능성을 시사한다. 기존 막기술에 존재하지 않던 구조와 물질 전달 성질을 가짐으로써 두 종류의 그래핀 막은 앞으로 수처리 기술을 비롯한 다양한 막 기술의 응용분야에서 효과적으로 기여할 가능성이 충분하다.
        4,600원
        23.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 Goal-Driven Optimization(GDO)을 바탕으로 한 양방향 차도선의 차량갑판의 구조설계에 대하여 최적화를 수행하였다. 차량갑판의 강도와 변형에 대한 영향을 검토하여 경제적 비용을 절약할 수 있는 최적점을 결정하였다. 실험계획법(DOE)과 반응표면법을 바탕으로 한 갑판두께를 110% 증가시켜 차량갑판의 강도와 강성을 높일 수 있었다. 이 결과에 대한 회귀분석을 수행하여 3차 다항식 모형인 최적 회귀모형식으로 제안하며 결정계수 R² 0.98정도로 나타내어 신뢰성을 확보할 수 있었다.
        4,000원
        24.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.
        4,000원
        25.
        2015.10 구독 인증기관·개인회원 무료
        폐유리는 화학성분 중 70% 이상이 실리카(SiO2) 성분으로 시멘트와의 반응시 포졸란 작용 및 기타 충전 재의 역할이 기대되기 때문에 폐유리를 콘크리트 품질개선을 위한 환경 친화적 혼화재로서 활용할 수 있는 방안에 대한 연구가 학계에서 일부 발표다. 따라서 본 연구에서는 자동차 폐부품인 폐유리의 재활용 방안을 모색하기 위하여 폐유리 미분말을 콘크리트 결합재의 20%까지 치환하여 대체율에 따른 모르타르와 콘크리 트의 기초물성 실험을 통해 도로 소구조물 및 콘크리트포장 활용성에 대한 기초자료를 제시하고자 한다. 본 연구에서는 폐유리 미분말 대체율에 따른 콘크리트의 기초 물성 실험으로 슬럼프, 공기량, 압축강도 를 수행하였고 역학적 특성 평가를 위해 탄성계수와 길이변화 시험을 수행하였다. 또한 내구성 평가를 위 해 탄산화, 염소이온침투저항성, 동결융해 저항성 시험을 수행하였다. 폐유리 미분말 활용을 위한 물성 시험결과, 대체율 10%까지는 슬럼프와 공기량은 증가하는 것으로 나타 났으며 폐유리 미분말 대체율에 따라 압축강도와 탄성계수가 저하하는 경향을 나타냈으나 탄성계수는 저하 폭이 상대적으로 작은 것으로 분석되었다. 또한 수축 특성은 폐유리미분말 대체율 변화에 따른 차이가 크지 않은 것으로 분석되었다. 압축강도 값은 대체율이 증가할수록 저하하는 경향을 나타내었다. 탄산화와 염소 이온침투저항 특성은 대체율이 증가함에 따라 감소 경향을 나타내었다. 동결융해저항성은 대체율 20%의 경 우에도 상대동탄성계수가 90%를 상회하므로 동결융해저항성에 미치는 영향은 크지 않을 것으로 판단된다. 폐유리 미분말 대체율에 따른 시험 결과를 종합할 때 폐유리미분말 5~10%를 치환할 경우 일반 시멘트를 사 용하는 경우와 유사한 성능을 나타내어 도로구조물 활용시 적용이 가능할 것으로 판단된다.
        26.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Generally, the Load of upper structures is transferred to concrete foundations through columns supporting them. So, the anchor connection system is usually adopted in order to connect the columns and the concrete foundations. To apply this system, the column-foundation connections need to be designed with enough stiffness. This study was experimentally conducted to effectively improve the structural detail of circular CFT column-foundation connections, to which axial and lateral load simultaneously apply. For this study, the test specimen with a general anchor and an anchor frame, and the specimens with the high-tension bolt and inner reinforcement were fabricated. In addition, double base plates were adopted to have the enough stiffness of connections. The behavioral characteristics and the failure mode were investigated and compared, and the improvement of structural detail of circular CFT column-foundation connections was suggested.
        3,000원
        27.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: An conventional method for electric power generation is converting thermal energy into mechanical energy then to electrical energy. Due to environmental issues such as global warming related with CO2 emission etc., were the limiting factor for the energy resources which resulting in extensive research and novel technologies are required to generate electric power. Thermal energy harvesting using thermoelectric generator is one of energy harvesting technologies due to diverse advantages for new green technology. This paper presents a possibility of application of the thermoelectric generator、s application in the direct exchange of waste solar energy into electrical power in road space. METHODS : To measure generated electric power of the thermoelectric generator, data logger was adopted as function of experimental factors such as using cooling sink, connection methods etc. Also, the thermoelectric generator、s behavior at low ambient temperature was investigated as measurement of output voltage vs. elapsed times. RESULTS: A few temperature difference between top an bottom of the thermoelectric generator is generated electric voltage. Components of an electrical circuit can be connected in various ways. The two simplest of these are called series and parallel and occur so open. Series shows slightly better performance in this study. An installation of cooling sink in the thermoelectric generator system was enhanced the output of power voltage. CONCLUSIONS : In this paper, a basic concepts of thermoelectric power generation is presented and applications of the thermoelectric generator to waste solar energy in road is estimated for green energy harvesting technology. The possibility of usage of thermoelectric technology for road facilities was found under the ambient thermal gradient between two surfaces of the thermoelectric module. An experiment results provide a testimony of the feasibility of the proposed environmental energy harvesting technology on the road facilities.
        4,000원
        28.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고정기초, 기초면진, 및 최상층에 TMD가 설치된 기초면진 구조물에 풍하중이 작용하는 경우에 구조물의 동적 거동을 해석하는 프로그램을 개발하여 면진장치가 풍하중이 작용하는 구조물의 동적거동에 미치는 영향을 파악하고자 한다. 난기류 스펙트럼을 이용하여 구조물에 작용하는 바람을 실제와 유사하도록 생성한 풍하중을 해석에 적용한다. 기초면진 장치가 구조물의 동적 거동에 미치는 영향을 분석하고, 풍하중이 작용하는 경우 기초면진이 설치된 구조물에서 TMD의 동적 제어 효과에 대하여 분석하고자 한다.
        4,000원
        29.
        2014.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a series of dynamic centrifuge tests were performed for a soil-foundation-structural interaction system in dry sand with various embedded depths and superstructure conditions. Sinusoidal wave, sweep wave and real earthquake were used as input motion with various input acceleration and frequencies. Based on the results, a natural period and an earthquake load for soil-structure interaction system were evaluated by comparing the free-field and foundation accelerations . The natural period of free field is longer than that of the soil-foundation-structure system. In addition, it is confirmed that the earthquake load for soil-foundation-structure system is smaller than that of free-field in short period region. In contrast, the earthquake load for soil-foundation-structure interaction system is larger than that of free-field in long period region. Therefore, the current seismic design method, applying seismic loading of free-field to foundation, could overly underestimate seismic load and cause unsafe design for long period structures, such as high-rise buildings.
        4,000원
        30.
        2013.12 구독 인증기관 무료, 개인회원 유료
        AC PDP의 Vt 폐곡선 측정에 의하여 개방형 유전체 구조에서 방전 전압과 내부 벽전압 등의 방전 특성이 종래의 구조와 비교되어 조사되었다. 개방형 유전체 구조는 상판 전극사이의 유전체를 없애서 유지 전극간의 방전이 더욱 쉽게 발생하도록 하는 구조이다. 개방형 유전체 구조에서 상판의 두 전극인 주사와 유지전극 간 방전 개시전압이 종래의 구조와 다르기 때문에 종래의 기입파형을 포함한 초기화 파형도 수정되어져야 한다. Vt 폐곡선 분석에 기초하여 개방형 유전체 구조에 적합한 수정된 구동파형이 제안되었고 42인치 AC PDP에서 실험되었다.
        4,000원
        31.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지반-구조물의 상호작용은 구조물의 동적 해석 및 기초 설계에 있어 지대한 영향을 미침에도 불구하고 그 중요성이 간과되어 왔다. 이는 모델링 과정의 복잡성으로 인해 실무자를 위한 적절한 절차가 미비 하다는 점에서 상당부분 그 이유를 찾을 수 있을것이다. 본 연구에서는 먼저 구조물의 동적 해석이 필수적으로 요구되는 강진지역인 미국 캘리포니아에 위치한 Cal(IT)2 건물을 대상으로지반 경계조건을 달리했을 시 해석상의 차이가 어느 정도 나는지를 검토해 보았다. 기초 모델링 기법의 하나인 Beam on NonlinearWinkler Foundation Model을 Linear Matrix Inequalities Model Reduction 기법을 활용하여 보다 간략하게 사용할 수 있도록 하였다.이렇게 하여 만들어진 대상 건물의 유한요소 모델과 실재 얻어진 가속도 데이터를 비교하여 제시된 방식을 통해 매우 우수한 해석 결과를얻을 수 있음을 보였다.
        4,000원
        32.
        2011.04 구독 인증기관·개인회원 무료
        We evaluated structural performance of Frame for uniformly distributed load to micro piles which was arranged in a line. We predicted behavior and load distribution with Abaqus which is general finite analysis program. And Structrual experiment was conducted using full scale test model.
        33.
        2010.04 구독 인증기관·개인회원 무료
        해안 지역은 해수의 운동에너지의 대부분은 해안에서 소산되며 이 과정에서 해안의 토사 등이 유실된다. 수면에 돌출된 방 파제에 비해 수중구조물은 해수의 유통을 가능하게 하고 해안선을 따라 해수순환을 가능케 한다. 이 연구에서는 해안 침식을 방지 기 능을 갖는 수중구조물을 수중장애물로 형상화 하고 후방의 흐름특성을 입자영상유속계를 이용하여 규명하였다. 그 결과 유선의 곡률 효과가 현저히 나타났으며 전단층 주위 유체의 유입 등의 영향으로 박리 전단층 내에서 커다란 와구조가 연속적으로 발생하였다.
        35.
        2008.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to investigate and analyze the plan and structural system of 4 kan(間) by 4 kan(間) square church built in early 20th century. At that time, three kinds of traditional wooden structure church had been built under the circumstances of transitional era : Basilica style such as Ganghwa Anglican Church, ‘ㄱ’ shaped style such as Keumsan Church and 4×4 Square style such as Bukok Church and Jacheon Church that are concerned in this study. Traditional plans and structural system were mixed with new religious function and transformed into korean peculiar style. 4×4 Square style is a residual product in that process. Despite of it, little concerns on it till now. The results of this study are described as follows. 1. The plan of these 4×4 square churches is divided into three areas : cathedra(1×1), attendance(4×2), and intermediation(4×2). The location of cathedra is commonly the opposition part of main gate and projected out of the building. Attendance area was also divided into two, man and woman, because of keeping a distance with each other. 2. The structural system of these 4×4 square churches are somewhat different because of their size and roof style. In the case of Bukok church, 4×4 square fall off 3×3 and 2×2 gradually and turn into paljak(八作) roof, which enable us to get in traditional entering methods. On the contrary, Jacheon church use hipped roof but almost alike pyramidal roof, which could make us not to recognize entering in the aspect of gable part.
        4,800원
        36.
        2008.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교량, 항만 및 각종 구조물과 산업설비에 대한 설계는 주로 결정론적 해석방법(Deterministic Analysis)에 의해 수행되고 있다. 그러나 구조물에 내재된 확률변수의 불확실성에 대한 영향을 보다 명확하게 평가할 뿐만 아니라 경제적인 설계를 위해서는 보다 개선된 평가방안이 요구된다. 이 연구에서는 터빈발전기 기초를 대상으로 합리적인 설계를 위해 확률유한요소법을 이용한 구조신뢰성해석을 수행하였다. 이를 위해 확률유한요소법을 신뢰성이론에 적합하도록 정식화하였으며, 대상 구조물의 부재강성 및 지진하중 등을 확률변수로 고려하여 동적응답해석 및 구조신뢰성해석을 효율적으로 수행할 수 있는 개선된 해석프로그램을 작성하였다. 작성된 해석프로그램을 이용하여 주요부재의 변위 및 부재력 응답에 대한 분산특성을 검토하였다. 아울러, 구조신뢰성해석에 따른 신뢰성지수 및 파괴확률을 제시함으로써, 대상 구조물의 구조 안전성을 정량적으로 평가하였다. 이 연구결과는 향후, 터빈발전기 기초의 개선된 설계방안을 설정함에 있어 기초자료를 제공할 것으로 기대된다.
        4,300원
        37.
        2007.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공간구조물의 성능기초 내진설계를 위한 기초연구의 하나로 강구조 골조막 구조의 탄소성 지진응답 특성을 분석하였다. 하부 골조의 가새의 선행좌굴을 유도하여 상부에의 지진 에너지 전달을 저감할 수 있음을 보여주고 있다.
        4,000원
        39.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        응답면기법, 유한요소법, 일차신뢰도법 그리고 반복 선형보간기법을 합리적으로 결합한 정교한 신뢰성해석 기법이 지진하중을 포함하는 단기 동적하중을 받는 복잡한 실제 비선형 동적구조계의 신뢰성 평가를 위하여 제안되었다. 기법은 하중 및 저항과 관련된 랜덤변수의 비선형성과 불확실성의 모든 중요 원천을 명시적으로 고려한다. 본 기법의 특징은 전통적 랜덤진동방법의 대안으로서 지진하중을 시간영역에서 적용하는 것이다. 실제 강프레임의 연결부에 대한 유연성을 표현하기 위하여 4-매개변수 리차드 모델을 사용하였다. 리차드 매개변수의 불확실성에 대한 고려도 알고리즘에 포함하였다. 다음으로 횡방향으로 유연한 강프레임을 철근콘크리트 전단벽으로 보강하였다. 균열 발생 후 전단벽에서의 강도저감 또한 고려되었다. 강절 연결부를 갖는 횡방향으로 유연한 강프레임, 각기 다른 강성의 부분강절 연결부를 갖는 강프레임, 그리고 콘크리트 전단벽으로 보강된 강프레임의 세 구조물을 고려함으로써 실제 구조물의 신뢰성평가를 위한 기법의 적용성을 검증하였다.
        4,800원
        40.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 지진하중을 받는 탄성구조물을 대상으로 층전단력 분포에 기초한 마찰감쇠기의 설계방법을 제시하였다. 먼저 마찰감쇠기의 슬립하중(slip-load)을 정규화하는 방법 별로 단자유도 시스템의 수치해석을 수행하고 비교하였다. 이를 통해 슬립하중과 가새 강성의 영향을 파악하였으며, 설치용 가새와 원구조물의 최적강성비를 찾았다. 다음으로는 다양한 고유주기와 층수를 갖는 구조물을 대상으로 수치해석을 통해 마찰감쇠기의 설치 층수와 위치의 결정방법 및 슬립하중의 분배 방법을 도출하였다. 이 과정에서 설치 층수가 포함된 성능지수를 사용하여 슬립하중의 총합으로부터 최적의 설치 층수를 도출하는 경험식을 제시하였다. 마지막으로 실제 지진하중을 사용한 수치해석을 통해 기존의 최적설계 방법과 비교하여 제안된 방법의 우수성을 입증하였다.
        4,000원
        1 2 3 4 5