검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 17

        1.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. Fire safety for the practical application of the composite beam has also been verified through the fire resistance tests and the heat transfer analyses. In this study 2-points bending tests were performed on the four specimens already tested for fire resistance to evaluate the residual bending strength of AU composite beam after fire accident. The same bending test was performed on the one fresh specimen having the same section and span of the specimens for practically comparative study.
        4,000원
        3.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The use of reclaimed aggregate has been recently increasing with the increase in the amount of waste asphalt concrete. The application of these materials can reduce the properties of the asphalt pavement when compared with the case when recycled aggregate is not used. The objective of this study is to evaluate the performance of the asphalt mixtures with various mix ratios of reclaimed aggregate. METHODS : To measure the performance, the following tests using the mixtures prepared in accordance with the Korea Standards were conducted: Hamburg wheel-tracking test, third-scale model mobile loading simulator test, and dynamic modulus test. RESULTS : The test results of the Hamburg wheel-tracking test indicate that the water resistance was similar in each mixture and the plastic deformation resistance was good in the high-ratio reclaimed aggregate mixture. In the case of the third-scale model mobile loading simulator test, the plastic deformation demonstrated a high resistance in the high-ratio reclaimed aggregate mixture. The results were similar to those of the Hamburg wheel-tracking test; however, the cracking resistance was poor with a high recycled aggregate incorporation ratio. The dynamic modulus test results demonstrated excellent resistance to plastic deformation at a relatively high ratio of reclaimed aggregate admixture. The crack resistance was weakened when a high ratio of reclaimed aggregate mixture was used. CONCLUSIONS: As the reclaimed aggregate content increased, the plastic deformation resistance increased and the crack resistance decreased.
        4,000원
        4.
        2017.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the effects of 27.12 MHz radio frequency (RF) heating on heat transfer phenomena during the thawing process of frozen food. To determine the velocity of the RF thawing machine, samples were frozen at -80oC and subjected to different power treatments. The phase change times (-5 to 0oC) of frozen radish were 30, 26, 13, and 8 min; those of pork sirloin were 38, 25, 11, and 5 min; those of rump were 23, 17, 11, and 6 min; those of chicken breast were 42, 29, 13, and 9 min; and those of tuna were 25, 23, 10, and 5 min at 50, 100, 200, and 400 W, respectively. The heating limit temperatures of the radish, pork sirloin, rump, chicken breast, and tuna samples were 19.5, 9.2, 21.8, 8.8, and 16.8oC at 50 W; 23.5, 15.5, 27.3, 12.3, and 19oC at 100 W; 42, 26.9, 45.7, 22.1, and 39.4oC at 200 W; and 48.5, 54.7, 63.6, 57.3, and 44.9oC at 400 W. These results suggest that high-power RF improves thawing velocity and heating limit temperatures, and that an improvement on the operation of the RF thawing machine, according to food temperatures, is needed.
        4,000원
        5.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES: A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS: The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS: The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS: The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.
        4,500원
        6.
        2014.09 구독 인증기관·개인회원 무료
        최근 교통량의 증가와 중차량 하중의 증가로 인한 아스팔트 콘크리트 포장의 파손이 증가하고 있고, 동 시에 포장의 파괴속도 또한 빨라지고 있다. 아스팔트 콘크리트 포장의 균열은 소성변형과 함께 포장의 주 요 파손형태 중 하나이다. 발생된 균열 내부로 물과 같은 수분의 침투가 있을 경우 포장에 치명적인 손상 을 입히게 된다(Yetkin Yildirim, P.E. 외 2명, 2006). 이러한 균열을 초기에 신속히 유지·보수하지 않으 면 포장의 파괴속도가 빨라지고 공용수명 또한 줄어들어 보수비용의 증가로 이어지게 된다. 따라서 초기에 균열을 제어하여 비용 및 시간을 절약하고 포장의 공용수명을 증가시키기 위한 예방적 유지·보수공법 중 하나가 균열보수제의 사용이다. 균열보수제는 균열 사이에 발생한 틈에 고성능 개질 아스팔트 바인더 또는 고성능 개질 유화아스팔트를 이용하여 채워줌으로써 균열이 더 이상 진전되지 않고, 포장의 공용수명을 연 장해 주는 기능을 한다. 또한 타 보수방법에 비하여 경제적이며, 기층 지지력이 양호하고 비교적 포장상태 가 양호한 경우 보수 방법으로 많이 사용한다(Yetkin Yildirim, P.E. 외 2명, 2006). 균열보수제의 종류로 는 가열식과 상온식으로 나뉘는데 현재 가열식 균열보수제만이 국내에서 상용화 되어 있으나, ASTM D6690을 참고하여 도로공사 시방으로 사용할 뿐 국내 규정은 없는 실정이다. 본 연구에서는 현재 국내 상용화 되고 있는 가열식 균열보수제 3종(A,B,C)과 현재 연구중인 2종(D,E)에 대하여 가열식 균열보수제 성능 평가의 중요한 요소인 콘 침입도 및 탄성회복률의 물성을 비교해 보았다.
        11.
        2002.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        폼드 아스팔트 공법은 가열 아스팔트 혼합물공법과 비교했을 때 골재와 아스팔트 가열에 필요한 다량의 에너지 소모가 없으며 가열로 인한 이산화탄소가 발생하지 않기 때문에 환경적으로 안정한 공법으로 평가되고 있다. 특히, 아스팔트 재활용 측면에서는 전체 혼합물량의 60~70% 까지 많은량의 폐 아스팔트를 사용할 수 있기 때문에 폐 아스팔트 재활용에 매우 효과적인 방법이다. 그러나, 폼드 아스팔트 공법은 항상 일정한 양질의 혼합물을 얻기가 어렵고 중(重)교통의 도로에 적용하기에는 문제점이 있다. 본 연구는 골재와 폐 아스팔트를 100°C 미만으로 가열하는 새로운 방식인 반 가열공법을 사용했을 때 얻어지는 반 가열 재생 폼드 아스팔트 혼합물의 성능과 반 가열 방식의 타당성에 대한 연구결과이다. 반 가열 방식으로 제조된 재생 폼드 흔합물을 실내에서 코팅율, 크리프시험, 회복탄성시험, 간접인장강도 및 마샬 안정도시험을 실시한 결과 혼합물의 현저한 개선 효과를 나타내었다.
        4,500원
        12.
        2002.03 구독 인증기관 무료, 개인회원 유료
        폼드 아스팔트 공법은 가열 아스팔트 혼합물공법과 비교했을 때 골재와 아스팔트 가열에 필요한 다량의 에너지 소모가 없으며 가열로 인한 이산화탄소가 발생하지 않기 때문에 환경적으로 안정한 공법으로 평가되고 있다. 특히, 아스팔트 재활용 측면에서는 전체 혼합물량의 60~70% 까지 많은량의 폐 아스팔트를 사용할 수 있기 때문에 폐 아스팔트 재활용에 매우 효과적인 방법이다. 그러나, 폼드 아스팔트 공법은 항상 일정한 양질의 혼합물을 얻기가 어렵고 중(重)교통의 도로에 적용하기에는 문제점이 있다. 본 연구는 골재와 폐 아스팔트를 100℃ 미만으로 가열하는 새로운 방식인 반 가열공법을 사용했을 때 얻어지는 반 가열 재생 폼드 아스팔트 혼합물의 성능과 반 가열 방식의 타당성에 대한 연구결과이다. 반 가열 방식으로 제조된 재생 폼드 흔합물을 실내에서 코팅율, 크리프시험, 회복탄성시험, 간접인장강도 및 마샬 안정도시험을 실시한 결과 혼합물의 현저한 개선 효과를 나타내었다.
        4,500원
        13.
        1989.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국산 소형어선용 예연소실식 디젤기관의 연료유를 가열할 경우, 연소특성 및 기관성능에 미치는 영향에 관하여 실험한 결과를 요약하면 다음과 같다. 1) 연료유 분사시작점은 연료유 가열온도의 증가에 따라 늦어지는 경향을 나타냈으며, 특히 저부하 운전시 늦어지는 경향이 현저했다. 2) 연소최고압력점은 연료유 가열온도의 증가에 따라 늦어졌으며, 연소최고압력은 연료유 가열온도 증가에 따라 감소하였으나 부하의 증가에 따라 증가하는 경향을 나타내었다. 3) 연료소비율은 부하의 증가에 따라 감소하였으며, 연료소비율이 가장 작은 연료유의 최적가열온도는 150℃부근임을 나타내고 있다. 4) 그을음농도는 부하와 연료유 가열온도의 증가에 따라 증가하는 경향을 나타냈다.
        4,000원
        14.
        2015.11 KCI 등재 서비스 종료(열람 제한)
        본 연구는 섬유를 혼입한 고강도 콘크리트의 온도 변화에 따른 내화특성 분석에 관한 연구로 고강도 콘크리트에 고온이 가해질 경 우 발생되는 폭렬현상에 대하여 방지효과가 있는 것으로 알려져 있는 하이브리드섬유와 강섬유를 함께 혼입하여 만든 복합섬유를 사용하여 온도 변화(100∼800°C)에 따른 고강도 콘크리트의 내화특성 및 역학적 메커니즘을 분석하였다. 또한 본 논문에서는 고강도 콘크리트 구조물 에서 가장 문제가 되는 폭렬현상을 막는 대책 중의 하나인 섬유 혼입을 통한 방법을 사용하여 SEM 및 XRD 분석 등의 방법으로 고온을 받은 고 강도 콘크리트의 열적 특성 및 역학적 특성을 규명하고자 하였다.
        15.
        2015.04 서비스 종료(열람 제한)
        Recently, the use of high strength concrete is increasing in order to increase of high-rise building. High strength concrete has properties that are weak in fire. In severe case, buildings have risk of collapse owing to occur spalling. For these reasons, the authors think it is required to conduct various study about thermal and mechanical properties of high strength concrete in fire. This study analyze thermal and mechanical properties of high strength concrete at elevated temperature to use composite fibers mixed method which is one of method to prevent spalling.
        16.
        2009.06 KCI 등재 서비스 종료(열람 제한)
        최근 열 치료법은 종양을 효율적으로 제거하는 방법으로 높은 해부학적 영상 대조도와 온도영상이 가능한 MRI와 결합하여 사용되고 있다. 본 연구는 2.45GHz에서 동작하도록 개발된 MR 호환 가능한 초고주파 평판 가열 안테나를 개발 및 성능평가에 대한 연구이다. 컴퓨터 모의실험을 통하여 평판 가열 안테나의 특성 및 전자파 인체 흡수율(SAR) 을 확인하고, 가열실험을 수행함으로써 제작된 안테나의 열 치료 적용 가능성을 확인할 수 있었다.