검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 89

        1.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.
        4,000원
        2.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
        4,000원
        3.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Restraints of Branch Lines are used as earthquake-resistant support devices for fire-fighting pipes along with sway brace devices. The central types are aligned and fixed in a straight line with center of the pipe, but the eccentric types are fixed to on side of the pipe, so a bending moment occurs. In this study, three specimens each of central type and eccentric type were installed at an angle of 45° from the vertical and a monotonic compression load of 1340N was applied. All central type samples satisfied 17.8mm of the allowable displacement, but all eccentric type samples failed to meet the target load and buckled. Therefore, when considering the performance of eccentric type restraints, both compressive load and bending moment must be considered. Even through material mechanics calculations, the yield stress of eccentric type - 3/8 inch all threaded steel bolt - exceeds 320Mpa of the allowable stress. A experiment standards need to be established for eccentric type restraints.
        4,000원
        4.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to experimentally analyze the seismic performance of column with RSB (Replaceable Steel Brace), a steel brace system with slot length as a variable. To evaluate the seismic performance of the RSB, three specimens were manufactured and subjected to cyclic loading tests. The length of the sliding slots were considered to be 5 mm and 10mm to enable the brace to resist the load from the initiation of flexural crack and shear crack. As a result of the test, the specimen reinforced with the RSB showed improved maximun load and effective stiffness, and energy dissipation capacity compared to the non-reinforced specimens. The specimens with 5mm sliding slot showed little difference in test result compared to the specimen with a 10mm sliding slot, indicating that the length of sliding slot has little influence on the effectiveness of RSB.
        4,000원
        5.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In piping systems, trapeze hangers are subjected to vertical and horizontal seismic loads and stiffeners are used. In this study, monotonic compression tests were conducted with the removable stiffeners using three variables: stiffener clamp fixing position, section length, and installation direction. The maximum load reinforced with stiffeners could withstand a compressive load of 11kN by applying a safety factor of 10%. It could be estimated that the fixing clamp spacing or the length of shape and load had a proportional relationship. And the stiffener must be fixed in the direction of the strong axis on hinge parts. Also the stiffener buckiling load design proposes to use a method of calculate the flexural buckling compressive strength of and unreinforced full threaded bolt.
        4,000원
        6.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, seismic performance evaluation was carried out for eight circular reinforced concrete columns designed seismically by KRTA[1]and KCI[8]. Primary design parameters for such columns included many longitudinal reinforcements, yield strength of reinforcements, the vertical spacing of spirals, aspect ratio, and axial force ratio. The test results showed that all the columns exhibited stable hysteretic and inelastic responses. Based on the test results, drift ratios corresponding to each damage state, such as initial yielding, initial cover spalling, initial core concrete crushing, buckling, and fracture of longitudinal reinforcement and final spalled region, were evaluated. Then, those ratios were compared with widely accepted damage limit states. The comparison revealed that the existing damage states were considerably conservative. This implies that additional research is required for the damage limit states of such columns designed seismically by current Korean design codes.
        4,000원
        7.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 형상기억합금을 이용한 능동구속기법의 콘크리트 기둥 내진보강효과를 실험적으로 평가하였다. 이를 위해 기존 니켈-티타늄계 형상기억합금보다 저렴한 철계 형상기억합금(Fe SMA)을 선정하여 능동구속기법에 적용하였다. 비내진 상세 를 가진 네 개의 동일한 원형 콘크리트 기둥을 제작한 후 기둥 하단부에 각기 다른 외부구속(무구속, CFRP 구속, Fe SMA 구속) 을 적용하였다. 정적수평반복가력실험 결과, 구속이 적용된 모든 기둥은 콘크리트 기둥의 연성적 휨거동을 이끌어내는데 효과 적인 것으로 밝혀졌다. 특히 Fe SMA 구속은 CFRP 구속에 비해 기둥 하단부 소성힌지에서 콘크리트의 박락 및 손상을 줄이는데 더욱 효과적이었다.
        4,000원
        8.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대표적인 비구조요소인 배관의 지진에 의한 손상은 관성력과 두 지지점 사이의 위상차에 의해 작용하는 반복하중 그 리고 허용변형량을 초과하는 상대변위 등에 의해 발생할 수 있다. 특히 주요 손상모드는 큰 반복하중에 의한 저주기피로임이 많은 실험적 연구를 통하여 알려졌다. 따라서 과도한 지진변위에 의한 배관의 손상을 방지하기 위하여 지진상대변위가 발생할 수 있는 위치에 지진분리이음 또는 지진분리장치의 적용이 요구된다. 신축관이음 중 하나인 벨로우즈는 지진분리이음으로 적용 할 수 있다. 본 논문에서는 3ply 금속 벨로우즈 신축관이음의 온도차에 의한 내진성능의 변화를 분석하기 위한 실험적 연구를 수행하였다. 상온환경에서 점진증폭 반복하중재하실험을 수행하였으며, -20°C의 저온조건에서 동일한 실험을 수행하고 그 결과 를 비교하였다. 실험 결과로부터, -20°C의 저온환경에서 금속벨로우즈의 변위성능은 약 10% 저하될 수 있음을 확인하였다.
        4,000원
        9.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
        4,000원
        10.
        2022.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is conducted to verify the seismic reinforcement effects of internally inserted buckling-restrained braces supported laterally by buckling-restrained rings for the seismic reinforcement of existing reinforced concrete buildings with non-seismic details. First, to evaluate the performance of KDS, the hysteretic characteristics of buckling-restrained braces are verified, and it is discovered that they satisfy the conformance criteria of the displacement-dependent damping device. Three full-scale, two-story reinforced concrete framework specimens are prepared to verify the seismic reinforcement effects, and the proposed buckling-restrained braces are bolstered with single diagonal and V-shaped braces to be compared with non-reinforced specimens. By performing a comparison with non-reinforced specimens that present intensive shear cracks at the bottom of first-floor columns, it is revealed that the maximum load and energy dissipation of specimens reinforced with the proposed buckling restrained braces, in which the structural damage extends evenly throughout the system, are approximately 4 and 6.2 times higher, respectively, which proves the effectiveness of the proposed seismic reinforcement method.
        4,000원
        11.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 경주, 포항에 연이은 지진 발생으로 인하여 내진설계에 관심이 높아지고 있다. 다가구주택 필로티기둥은 수직 비정형 시스템으로 상,하부층의 강성 차이로 인하여 지진 발생 시 막대한 피해가 예상되기 때문에 다가구주택 필로티기둥의 내 진보강이 필요하다. 그러나 민간 소유인 다가구주택의 경우 막대한 비용과 시간으로 인하여 보강이 어려운 실정이다. 이에 따 라, 복합섬유패널로 에폭시 접착제 미사용으로 건식시공이 가능한 전단보강공법을 제안하고자 한다. 본 연구에서는 복합섬유패 널 보강 유무에 따른 내진보강공법의 전단내력을 실험을 통하여 검증하였고, 에폭시를 사용하지 않아 일체화 거동을 하지는 않 지만 복합섬유패널의 영향으로 전단내력은 1.46∼1.49배 증가하는 것으로 평가되었다. 따라서 다가구주택 필로티기둥의 내진보 강효과가 있을 것으로 판단된다.
        4,000원
        12.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, to verify the structural performance of the Composite Joint System (CJS) hybrid structural model, a cyclic load test was performed and evaluated and verified through the test. To verify the structural performance of the CJS hybrid structural systems’ joint and evaluate the seismic performance, four three-dimensional real-size specimens were developed with three internal beam-column specimens and one external beam-column specimen. The three interior column specimens were classified by different methods of joining the upper column and lower column, and the same bonding method as the primary specimen was used for the exterior column. The structural performances in terms of drift, strength, and energy dissipation capacity were analyzed and compared based on the experimental results. From the displacement-based loading experiment, all specimens showed a lateral drift of 4.0% without any significant strength drop and stable energy dissipation capacity.
        4,200원
        13.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        철근콘크리트 기둥에서 후프철근의 내진갈고리 시공성을 개선하기 위하여 기존 연구에서 “띠철근 갈고리 뽑힘 방지 장치”인 RCC장치(Rebar Confinement Clip)를 제안하여 인발실험을 통한 부착 및 정착성능 실험을 실시하였다. 그러나, 기존 연구의 실험에서는 콘크리트 구조기준에서 제시하는 피복두께를 준수하지 않았다. 그러므로, 보다 신뢰성 있는 실험 결과를 도출하 기 위하여 기준에서 제시하는 피복두께를 준수한 실험체로 실험을 실시할 필요가 있다. 이를 위하여 총 6개 실험체를 제작하여 실험을 실시하였으며 실험결과, 부착 및 정착의 합성강도는 RCC장치로 체결된 띠철근의 갈고리가 내진갈고리가 발휘하는 강도 보다 높게 나타났다. 또한, 내진갈고리의 실험체 균열 진전 및 파괴 양상과 RCC장치로 체결된 띠철근의 실험체는 유사하게 나타났다. 그러므로, 콘크리트 피복두께를 준수한 실험체에서 RCC장치로 띠철근에 체결할 경우 내진갈고리가 발휘하는 동등한 성능을 보유하고 있는 것으로 평가된다.
        4,300원
        15.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        16.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The performance enhancement of various damping systems from natural hazards has become an highly important issue in engineering field. In this paper, ENTA hysteretic dampers were tested under cyclic loadings to evaluate their performance in terms of ductility and energy dissipation. The test results showed that the hysteretic dampers are effective damping systems to enhance the buildings performance for remodeling and retrofit of buildings. Also, the hysteretic dampers were modeled in FEM(Finite Element Method) structural analysis program. As comparing the computer modeling and the experiment, this study model reflects the nonlinear behavior of steel and derives the hysteresis loop.
        4,000원
        17.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        내진설계기준이 개정됨에 따라 기 시공된 철근콘크리트 건축구조물의 내진보강에 대한 관심이 높아지고 있다. 특히 내진철근상세가 적용되지 않은 철근콘크리트 기둥의 경우 지진이 발생할 경우 취성적인 전단파괴가 발생할 가능성이 크다. 본 연구에서는 아라미드 FRP를 이용하여 비내진상세 철근콘크리트 기둥의 휨 및 전단내력 보강 후, 실험체를 반복횡하중 가력하여 아라미드 FRP의 내력 상승효과 및 연성능력의 증가를 확인하였다. 무보강 및 아라미드 FRP 보강 실험체를 비교 한 결과 아라 미드 FRP 보강이 비내진상세 철근콘크리트 기둥의 내력을 증가시키고 연성능력 또한 증가시킴을 확인하였다. 또한 비내진상세 철근콘크리트 기둥의 아라미드 FRP 보강 시 기둥 뿐만 아니라 접합부의 보강 또한 필요함을 확인하였다.
        4,000원
        18.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the out-of-plane seismic resistance of lightly-reinforced existing walls strengthened with thick RC jacket was investigated. The thick RC jacket with a thickness of 500 mm was placed at one side of the thin existing wall with a thickness of 150 mm. At the interface between the wall and RC jacket, a tee-shaped steel section with a number of anchor bolts and dowel bars was used as the shear connector. To investigate the connection performance and strengthening effects, the cyclic loading tests of four jacketed wall specimens were performed. The tests showed that the flexural strength of the jacketed walls under out-of-plane loading was significantly increased. During the initial behavior, the tee shear connector transferred forces successfully at the interface without slip. However, as the cracking, spalling, and crushing of the concrete increased in the exiting walls, the connection performance at the interface was significantly degraded and, consequently, the strength of the jacketed walls was significantly decreased. The flexural strength of the jacketed walls with tee shear connector was estimated considering the full and partial composite actions of the tee shear connector.
        4,000원
        19.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라는 지진으로부터 안전한 국가라는 인식이 형성되었으나 최근 경주와 포항 지진에 의해 발생된 구조물 피해로 구조물 안전성 확보를 위한 관심이 증가하고 있다. 국내 중저층 건축물에 다수 적용되고 있는 철골 모멘트 골조는 기본적인 내진성능을 보유하고 있지만 보-기둥 접합부의 소성변형으로 인한 취성파괴로 다양한 문제를 발생시킨다. 최근에는 이러한 문제를 해결하기 위해 구조물에 상온에서 잔류변형으로부터 원형복원이 가능한 초탄성 형상기억합금의 활용에 관한 연구가 진행되고 있다. 따라서 본 연구에서는 소성변형이 집중되는 보 플랜지 부재에 초탄성 형상기억합금 보강판을 활용한 보–기둥 접합부에 대하여 실험을 통한 실질적인 내진성능을 평가하고자 한다.
        4,000원
        20.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존 내진보강시스템의 문제점을 개선하기 위한 듀얼프레임형 내진보강시스템은 기존구조체, 외부보강체, 댐퍼로 구성된다. 듀얼시스템은 지진발생시 주기차이로 인하여 기존구조체와 외부보강체 사이에서 상대변형이 발생되고 이를 댐퍼가 대응하여 안정적으로 지진에너지를 흡수하여 내진성능을 확보한다. 본 논문에서는 듀얼시스템의 구조성능을 분석하기 위하여 정적반복가력실험을 수행한다. 실험결과, 듀얼시스템 실험체는 비보강 실험체와 유사한 손상상태를 나타내었다. 이와 같이 나타난 이유는 정적실험 시 기존구조체를 강제 이력 시켰기 때문이다. 하지만 하중-변형관계곡선에서 핀칭현상이 완화되는 것으로 나타났고, 안정적인 이력거동을 통하여 비보강 실험체에 비해 5.3배 더 많은 에너지를 흡수하였다. 또한 동일한 층간변형각 및 누적 변형에 대해서도 더 많은 에너지를 흡수할 수 있음에 따라 듀얼시스템을 적용할 경우 내진성능을 향상시킬 것으로 판단된다. 또한 듀얼시스템을 실무에 적용하기 위해서는 설계프로세스 등에 대한 연구가 필요하며, 본 논문을 추후 연구의 기초자료로 제시하고자 한다.
        4,000원
        1 2 3 4 5