In order to experimentally investigate the operation characteristics of the multi-heat pump with 3 indoor units, the dynamic characteristics of the cooling cycle is studied using the psychrometric multi-calorimeter. The compressor of the heat pump is the scroll inverter type, and since 3 indoor units operate cooling at the same time, it is operated at 100% full load. In particular, 3 types of indoor unit temperatures (20, 24, 26°C) are selected to understand the operation process of the multi-heat pump by the setting temperature. From this experiment, the compressor controls the EEV opening for each indoor unit while varying the frequency according to the initial start, transient, and steady operation. In addition, as the setting temperature increases in the steady range, the frequency of the compressor and the average opening degree of the EEV decrease.
본 연구는 다중벽 탄소나노튜브(MWCNT)로 보강된 복합재 구조의 동적 해석을 다루었다. Mori-Tanaka 모델을 기반으 로 MWCNT 중량 비율, 패널의 곡률, 그리고 CNT의 임의 배열이 복합재의 동적거동에 미치는 상호작용을 연구하였다. 본 연구 결과는 CNT의 부피함유비율의 변화에 따른 복합재의 유효탄성계수를 예측하는 기존 문헌결과와 비교하여 검증하였다. 수치해 석 예제는 복합재의 동적 특성을 평가함에 있어서 MWCNT 보강의 불규칙한 배열 또는 기울어진 방향으로 배치된 효과에 대한 중요성을 제시하였다.
본 연구에서는 차량-교량 상호작용 시스템의 고유진동수 변화를 분석하였다. 차량이 주행하는 교량의 동특성은 차량의 질량 및 진 동을 무시하지 않는 경우 상호작용을 반영해야 하는데, 이때 시스템은 시간가변적이므로 고유진동수 또한 시간가변적인 특성을 보인 다. 따라서 본 연구에서는 차량과 교량을 각각 2자유도를 갖는 시스템으로 모델링하여 차량의 위치와 질량비 그리고 시스템 강성비에 따른 시간가변적 고유진동수를 산출하였다. 분석 결과 일반적으로 초기 고유진동수가 작은 시스템은 상호작용으로 인하여 증폭비가 낮아지는 추세를 보이나 상호작용이 발생할 경우 증폭비는 분기점을 보이며 비선형적 추세를 보이는것을 알 수 있다. 따라서 상호작 용이 발생하는 시스템차수에 대한 이해가 필요함을 알 수 있다.
The Gyeongju and Pohang earthquakes caused damages to many cultural properties; particularly, stone pagoda structures were significantly damaged among masonry cultural properties. To preserve these structures, it is necessary to understand their dynamic behavior characteristics under earthquakes. Analyses on such areas as deformation, frequency, maximum acceleration, permanent displacement, sliding, and rocking have to be performed. Although many analytical studies have already been conducted, dynamic behavior studies based on experiments are insufficient. Therefore, this study analyzed dynamic behavior characteristics by performing a shaking table experiment on a three-story stone pagoda structure at the Cheollongsa temple site damaged by the Gyeongju earthquake. As a result of the experiment, the displacements of stylobates did not occur significantly, but the tower body parts rotated. In particular, the rotation of the 1F main body stone was relatively larger than that of the other chief body stones because the 1F main body stone is relatively more slender than the other parts. In addition, the decorative top was identified as the component most vulnerable to sliding. This study found that the 1F main body stone is vulnerable to rocking, and the parts located on the upper part are more vulnerable to sliding.
The dynamic characterization of a three-story auxiliary building in a nuclear power plant (NPP) constructed with a monolithic reinforced concrete shear wall is investigated in this study. The shear wall is subjected to a joint-research, round-robin analysis organized by the Korea Atomic Energy Research Institute, South Korea, to predict seismic responses of that auxiliary building in NPP through a shake table test. Five different intensity measures of the base excitation are applied to the shaking table test to get the acceleration responses from the different building locations for one horizontal direction (front-back). Simultaneously to understand the global damage scenario of the structure, a frequency search test is conducted after each excitation. The primary motivation of this study is to develop a nonlinear numerical model considering the multi-layered shell element and compare it with the test result to validate through the modal parameter identification and floor responses. In addition, the acceleration amplification factor is evaluated to judge the dynamic behavior of the shear wall with the existing standard, thus providing theoretical support for engineering practice.
This study evaluates safety assessment before and after repair of Seonamsa temple seungseon bridge, which refer to the representative Hongye bridge in Korea. In this approach natural frequency of the structure were considered in the modeling procedure. Trial & error method is applied to obtain the approximate natural frequency before and after retrofit construction. Stiffness of the actual structure was examined to account for the dynamic characteristics of Hongye bridge measured in the field and adjusting parameters in computer modeling. The safety and usability of the stone structure in terms of load bearing capacity and displacement were examined.
The governing equation for a dome-type shallow spatial truss subjected to a transverse load is expressed in the form of the Duffing equation, and it can be derived by considering geometrical non-linearity. When this model under constant load exceeds the critical level, unstable behavior is appeared. This phenomenon changes sensitively as the number of free-nodes increases or depends on the imperfection of the system. When the load is a periodic function, more complex behavior and low critical levels can be expected. Thus, the dynamic unstable behavior and the change in the critical point of the 3-free-nodes space truss system were analyzed in this work. The 4-th order Runge-Kutta method was used in the system analysis, while the change in the frequency domain was analyzed through FFT. The sinusoidal wave and the beating wave were utilized as the periodic load function. This unstable situation was observed by the case when all nodes had same load vector as well as by the case that the load vector had slight difference. The results showed the critical buckling level of the periodic load was lower than that of the constant load. The value is greatly influenced by the period of the load, while a lower critical point was observed when it was closer to the natural frequency in the case of a linear system. The beating wave, which is attributed to the interference of the two frequencies, exhibits slightly more behavior than the sinusoidal wave. And the changing of critical level could be observed even with slight changes in the load vector.
In this paper, the dynamic snapping of the 3-free-nodes spatial truss model was studied. A governing equation was derived considering geometric nonlinearity, and a model with various conditions was analyzed using the fourth order Runge-Kutta method. The dynamic buckling phenomenon was observed in consideration of sensitive changes to the force mode and the initial condition. In addition, the critical load level was analyzed. According to the results of the study, the level of critical buckling load elevated when the shape parameter was high. Parallelly, the same result was caused by the damping term. The sensitive asymmetrical changes showed complex orbits in the phase space, and the critical load level was also becoming lowly. In addition, as the value of damping constant was high, the level of critical load also increases. In particular, the larger the damping constant, the faster it converges to the equilibrium point, and the occurrence of snapping was suppressed.
The purpose of this study is to investigate the distribution patterns of displacement and acceleration fields in a nonlinear soil ground based on the interaction of high-speed train, wheel, rail, and ground. For this purpose, a high-speed train in motion was modeled as the actual wheel, and the vertical contact of wheel and rail and the lateral contact, caused by meandering motion, were simulated; this simulation was based on the moving mass analysis. The soil ground part was given the nonlinear behavior of the upper ground part by using the modified the Drucker– Prager model, and the changes in displacement and acceleration were compared with the behavior of the elastic and inelastic grounds. Using this analysis, the displacement and acceleration ranges close to the actual ground behavior were addressed. Additionally, the von-Mises stress and equivalent plastic strain at the ground were examined. Further, the equivalent plastic and total volumetric strains at each failure surface were examined. The variation in stresses, such as vertical stress, transverse pressure, and longitudinal restraint pressure of wheel-rail contact, with the time history was investigated using moving mass. In the case of nonlinear ground model, the displacement difference obtained based on the train travel is not large when compared to that of the elastic ground model, while the acceleration is caused to generate a large decrease.
Recently, the occurrence frequency of earthquake has increased in Korea, and many cultural assets have been damaged. Cheomseongdae is a valuable cultural assets that must be preserved historically and culturally. But, the masonry structure such as Chemseongdae is vulnerable to lateral forces. Therefore, in this study, structural modeling and dynamic analysis are performed to reflect the ground state and structural form of Cheomseongdae. Also, discrete element analysis technique is applied and dynamic behavior characteristics are analyzed according to earthquake load. For this purpose, displacements and stresses according to locations are reviewed and then swelling and distortion are analyzed.
2017년 발생한 포항 지진으로 인하여 천장재, 외장재, 커튼월 등 비구조재의 파괴에 의한 피해가 다수 보고되었으며 비구조재의 내진설계가 중요해지고 있다. 본 연구에서는 임팩트해머 테스트를 통해 행어볼트 길이에 따른 천장재의 고유진동수와 감쇠비를 식별하였다. 또한 천장재가 벽 또는 다른 구조체에 충돌하는 경우 발생하는 충격효과를 정확히 고려하기 위해 충돌실험을 수행하였다. 식별된 천장재의 동특성과 충격지속시간을 바탕으로 실제로 천장재가 지진하중으로 인하여 주변 구조물과 충돌이 발생하는 경우에 대한 천장재 응답특성을 수치해석을 통하여 분석하였다. 수치해석 시뮬레이션 결과, 충격하중은 이격거리에 따라 선형적으로 증가하는 경향을 보였으며, 달대길이와는 무관한 것으로 나타났다.
Yangjindang house, which is located in Sang-ju province of South Korea, is one of the special Hanok structures dated back to Joseon dynasty. This study aims to examine structural safety of the Yangjindang wood frame building considering dynamic parameters such as the natural frequency and damping ratio. The numerical model of the wood frame building is implemented using Midas Gen, especially the wood joint where column and beam were connected. The behavior of the actual frame building was compared with the modeling results. In addition, structure responses such as shear force, axial force, flexural moment and deflections were calculated and compared with the allowable limits. Numerical results show that, generally, despite of some local members shear failure, Yangjindang’s structural response does not exceed the limitation according to current standards.
The arched stone bridge has been continuously deteriorated and damaged by the weathering and corrosion over time, and also natural disaster such as earthquake has added the damage. However, masonry stone bridge has the behavior characteristics as discontinuum structure and is very vulnerable to lateral load such as earthquake. So, it is necessary to analyze the dynamic behavior characteristics according to various design variables of arched stone bridge under seismic loads. To this end, the arched stone bridge can be classified according to arch types, and then the discrete element method is applied for the structural modelling and analysis. In addition, seismic loads according to return periods are generated and the dynamic analysis considering the discontinuity characteristics is carried out. Finally, the dynamic behavior characteristics are evaluated through the structural safety estimation for slip condition.
구조물의 감쇠비는 내풍성능을 평가하는 가장 중요한 요소 중의 하나이다. 구조물의 실제 감쇠비는 대부분 계측된 응답을 기반으로 시스템 식별기술에 의하여 이루어진다. 그러나 예측된 감쇠비는 계측조건, 계측시간 및 시스템 식별기술에 따라 오차를 보이는 등 불확실성을 가지고 있다. 본 연구에서는 기 개발된 가상 동적진동기(Virtual Dynamic shaker)에 주요 개념으로 사용되었던 외부하중 스펙트럼의 전체 평탄성을 국부 평탄성으로 개념을 확대하여 감쇠비 추정을 보다 정교하게 하는 기법을 개발하였다. 국부 평탄성을 개념을 사용하여 감쇠비를 구하고자 하는 대상 모드의 고유진동수 부근에 적용함으로서 보다 정확하게 감쇠비 추정하는 기법을 다루었다. 본 개발된 기법을 검증하기 위하여 고층건물의 상시진동에 대하여 적용하였으며, 기존 시스템 식별법, 자유진동실험에 의한 결과와 비교 평가하였다. 그 결과 전체 평탄성을 가지는 개념에 비하여 국부평탄성을 가지는 VDS가 보다 정확하게 감쇠비를 추정하는 것을 보였다.
계면동전위(electrokinetic potential)로 불리는 제타전위(zeta potential)란 표면 전하적 특성을 정량화한 값으로, 전기동역학적 현상으로 인하여 발생하는 전기적 유동층을 통과하는 전위차를 말한다. 이러한 제타전위는 표면화학분야의 기초, 응용적인 연구에서 중요하다. 제타전위는 용액 내에서 표면 전하 특성 정보를 얻을 수 있다. 이를 측정하는 방법으로는 계면동전위효과(electrokinetic effects)를 이용한다. 현재 위 효과를 이용하여 제타전위 측정 기기로 측정이 쉽게 가능하고, 많은 연구가 진행되어왔다. 본 연구에서는 계면동전위의 원리, 측 정, 결과 등을 제시하면서 분리막 표면 특성평가에 관한 내용을 제시하였다.
관측된 지반진동은 지진원, 지각감쇠 및 지반의 증폭특성 등 3가지 주요 인자로 구성되어 있고 특히 지반증폭 특성은 지진원 및 감쇠특성을 평가할 때 필요하다. 또한 지진재해도를 분석하기 위해 지반의 증폭 특성에 정보가 내진 공학 뿐만 아니라 암반공학적 특성 분석에서 필수적이다. 지반의 증폭특성 분석을 위해 분석대상 관측소와 기준 관측소 지반진동의 수평/수직 비를 이용하는 방법을 적용하였다. 기존의 기준관측소의 수직성분 방법에 더하여 새로이 기준관 측소의 수평성분 방법을 새로이 시도하였다. 본 연구는 예당저수지 인근에 설치한 4개의 관측소에서 관측된 6개의 가 속도 지반진동을 이용하여 각 지반진동의 S파, Coda파 및 배경잡음 각각을 분석한 지반증폭 특성을 상호 비교하였다. 4개 관측소 공통적으로 S파와 Coda파를 이용한 결과는 상호 유사한 지반증폭 특성을 보였다. 다만 배경잡음은 다른 2 개 지진 에너지와 비교할 때 전혀 다른 지반증폭 특성을 보였고 이는 배경잡음의 발생 원인이 관측소 마다 서로 다르 기 때문으로 입증되었다. 4개 각각의 지진 관측소마다 저주파수 및 고주파수 증폭특성과 관측소 고유의 우월주파수가 서로 상이하여 관측소 고유의 증폭특성을 보여주었다. 또한 본 연구의 결과와 다른 방법의 결과와 비교하면 지반의 동 적특성 및 지반분류 연구에 많은 정보를 제시할 수 있다.