검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 11

        1.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study quantitatively evaluated size selectivity for three netting shapes (T0; regular, T45, T90) and hanging ratio (35%, 70%) of T0 netting used for trawl codend. The size selectivity experiment was performed in a tank using a cube experimental model with a length of 50 cm on one side and 389 experimental individuals, jack mackerel (Trachurus japonicus). In the selectivity analysis, a selectivity curve was created based on the selection ratio using a logistic function, and the 25%, 50%, and 70% selection length and selection range  were obtained. The T0 netting was 19.54 cm when the 50% selective length, which is a selectivity evaluation index, had a hanging ratio of 35%, a selection range of 0.51 cm, and 22.70 cm and 3.08 cm for the hanging ratio of 70%. The T45 netting was 24.34 cm and 2.13 cm, and the T90 netting was 23.51 cm and 2.84 cm. The results of the T45 netting and the T90 netting are similar, and the 50% selection length and selection range were relatively larger than the T0 netting. There was a significant difference in the correlation between the circumference of the inner circle of the mesh by the shape of the netting and the body girth of the experimental individual (Pearson test,      ). There was no significant difference in the correlation between the selection ratio by the T0 netting, T45 netting, and T90 netting with a 70% hanging ratio (one-way ANOVA,   ). The results of this study showed that selectivity such as T45 netting and T90 netting appeared when the hanging ratio, which maximizes the area of T0 netting, was maintained at 70%.
        4,000원
        2.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라 사과 재배에 가장 널리 이용되는 수형은 세장방추형으로 수령이 증가함에 따라 수관 내부의 광환경이 불량해진다. 전정을 통한 부분적인 수관 변경은 이러한 문제점 개선의 효율적인 대안이라고 할 수 있다. 본 연구는 이와 관련하여 나무 중간의 수관 변경에 따른 수관 내 광환경의 변화를 살펴보고, 과실 품질 향상을 위한 적절한 측지 관리 방법을 모색하고자 4.0 × 1.5m로 재식된 ‘감홍’/M.9을 대상으로 2년간 시험을 수행하였다. 처리 1은 측지를 짧게 단축하여 수관 폭을 좁게 만드는 것이었고, 처리 2는 측지를 유인하는 것이었으며, 처리 3은 대조구로 기존 세장방 추형의 수관을 유지했다. 1. 처리 1은 수관 하부로의 광투과율이 가장 높았고 기존 세장방추형에 비해 과중과 착색도가 높은 과실의 생산이 가능 했으며 높은 꽃눈 분화를 나타냈다. 2. 처리 2는 유인에 따라 가지의 중첩에 의한 음영 발생 증 가로 광투과율이 오히려 감소하였고 이에 따라 과실 착색의 저하를 초래하였다. 3. 따라서 광환경 개선과 하부의 과실 품질 향상을 위한 가 장 효율적인 측지 관리 방법은 중간에 위치한 측지를 길이 50 cm 내로 단축 전정하여 수관 폭을 좁게 유지하는 것으로 판단되었다.
        4,000원
        3.
        2016.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Carbon nanofiber (CNF) composites coated with spindle-shaped Fe2O3 nanoparticles (NPs) are fabricated by a combination of an electrospinning method and a hydrothermal method, and their morphological, structural, and chemical properties are measured by field-emission scanning electron microscopy, transmission electron microscopy, Xray diffraction, and X-ray photoelectron spectroscopy. For comparison, CNFs and spindle-shaped Fe2O3 NPs are prepared by either an electrospinning method or a hydrothermal method, respectively. Dye-sensitized solar cells (DSSCs) fabricated with the composites exhibit enhanced open circuit voltage (0.70 V), short-circuit current density (12.82 mA/cm2), fill factor (61.30%), and power conversion efficiency (5.52%) compared to those of the CNFs (0.66 V, 11.61 mA/cm2, 51.96%, and 3.97%) and spindle-shaped Fe2O3 NPs (0.67 V, 11.45 mA/cm2, 50.17%, and 3.86%). This performance improvement can be attributed to a synergistic effect of a superb catalytic reaction of spindle-shaped Fe2O3 NPs and efficient charge transfer relative to the one-dimensional nanostructure of the CNFs. Therefore, spindle-shaped Fe2O3-NPcoated CNF composites may be proposed as a potential alternative material for low-cost counter electrodes in DSSCs.
        4,000원
        4.
        2009.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        재식거리 3.2×1.2m로 심어 수고 2.5m의 세장방추형으로 관리해 오던 '후지'/M.9 사과나무를 재식 6년차부터 2년 동안 수고 4.0m로 관리하였다. 이후 재식 8년차에 수고를 2.5m(대조구), 3.0m, 3.5m, 4.0m로 조절하고 수고에 따른 2년간의 생산성 및 노동력을 비교하였다. 대조구인 수고 2.5m를 기준으로 하여 처리에 따른 10a당 생산량을 비교해 보면 첫해에는 수고 4.0m, 3.5m, 3.0m에서 각각 46%, 25%, 4%, 2년차에는 17%, 12%, 10% 증가하였다. 수고에 따른 과실 품질에 있어서는 가용성 고형물 함량은 2개년 모두 수고 2.5m가 가장 높았으나, 착색정도는 수고에 따른 뚜렷한 차이가 없었다. 노동력은 수고가 높아질수록 증가하였으나, 노동력에 따른 과실생산량은 수고가 낮을수록 증가하였다. 조수입과 순수입은 2005년의 경우 수고가 높아질수록 증가하였으나, 2006년은 수고 2.5m가 가장 높았지만 통계적 유의차는 없었다. 따라서 수고에 따른 생산성, 노동력, 경제성을 고려해 볼때 적정수고는 3.0~3.5m인 것으로 판단되었다.
        4,000원
        5.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        '후지'/M.9에 대한 세장방추형에 적합한 하단측지수 구성을 위하여 하단측지수를 달리하여 수체생육, 광환경, 수량 및 과실품질을 조사하였다. 하단측지수준별 생육은 하단측지수를 5개로 유지했을 때 수폭은 넓었고, 신초장 및 정단신초장은 증가하였다. 수관위치별 수광률은 하단측지수가 5개인 처리구에서 수관상부(지상 150cm)와 수관중부(지상 100cm)에서는 높은 경향을 보였다. 총 단과지 화아수는 측지수에 따라 차이가 없었으나, 수관위치별로 보면 수관하부(지상 120cm 이하)에서 하단측지수가 5개 처리에서 가장 많았으며, 화아의 횡경도 커지는 경향이었다. 과실수량은 하단측지수가 5개에서 가장 많았고, 과중은 하단측지수가 5개와 8개에서 증가하는 경향이었다. 과실특성은 과형지수, 경도, 산함량, Hunter L, b값은 수관위치와 측지수준에 따라 차이가 없었으나, 가용성고형물 함량은 하단측지수가 5개일 때 높았다. 과실의 착색도를 나타내는 Hunter a값은 수광률이 가장 높은 하단측지수를 5개로 유지한 처리구에서 가장 높게 나타났다.
        4,000원
        6.
        2004.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동결 과정 중 필수적인 단계중 하나인 냉각(cooling)과 냉각 후 배양시간이 생쥐 난자의 방추체의 형태와 염색체의 배열에 미치는 영향을 알아봄으로서 냉각 후 손상되었던 난자의 방추체와 염색체가 정상적으로 회복하는데 필요한 최적의 배양시간을 알아보기 위해 본 실험을 실시하였다. 생후 4-6주령의 암컷 B6C3Fl 생쥐를 과배란 처리하여 metaphase II상태의 난자를 회수하여 다음과 같이 처리하였다. 대조군은 난자를 냉각처리하지 않았으며 실험군은
        4,000원
        9.
        2000.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        충북 보은군 임곡리의 시추 표품(90-B-1)에서 Pseudoschwagerina paraborealis 와 Quasifusulina sp.를 기재하였으며, 이에 근거하여 Pseudoschwagerina대를 설정하였다. Pseudoschwagerina paraborealis는 영월 탄전의 밤치층에서 보고되었고 유라시아 대륙의 아셀리안과 사크마리안 지층에서 다수 기재된 바 있다. 보은 탄전에서 Pseudoschwagerina paraborealis 가 산출되는 것은 영월탄전의 밤치층과 대비되는 지층이 보은 탄전에서도 존재한다는 증거이다. 이 방추충과 함께 같은 층준에서 Quasifusulina sp.가 산출된다. 보은 탄전에서 전기 고생대의 방추충 종을 동정하여 발표하는 것은 이번이 처음이다.
        4,000원
        11.
        1986.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        영월탄전 요봉계곡에 분포하는 석탄기 석회암에서 소형 방추충의 일종인 SCHUBERTELLIDAE가 발견된다. 이 곳에서 기재된 SCHUBERTELLIDAE는 2속 6종으로 Schubertella gracilis znensis, S. lata elliptica, S. obscura, Fusiella praecusor, F. praecusor paraventricosa, F. praelancetiformis이다. 이 방추충은 중국과 쏘련에서 기재된 것과 일치하며, 벽구조의 변화없이 모스코비아계 하부로부터 상부까지 산출된다.
        4,000원