검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 36

        3.
        2023.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        프리캐스트 코핑의 중공부 주철근 단절로 인한 단점을 보완하고, 거치대 삽입 없이 주철근을 거치대로 활용할 수 있 도록 철근-콘크리트 접촉부의 응력집중을 완화할 수 있는 하중분산세트의 성능을 검토하였다. 유한요소해석 및 축소모형실험을 통해 검토한 결과 하중분산세트는 철근-콘크리트 접촉부의 응력집중을 효과적으로 완화시켜 거치 시 콘크리트 파손을 방지할 수 있을 것으로 판단된다.
        4,000원
        4.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Tuned mass damper (TMD) is widely used to reduce dynamic responses of structures subjected to earthquake loads. A smart tuned mass damper (STMD) was proposed to increase control performance of a traditional passive TMD. A lot of research was conducted to investigate the control performance of a STMD based on analytical method. Experimental study of evaluation of control performance of a STMD was not widely conducted to date. Therefore, seismic response reduction capacity of a STMD was experimentally investigated in this study. For this purpose, a STMD was manufactured using an MR (magnetorheological) damper. A simple structure presenting dynamic characteristics of spacial roof structure was made as a test structure. A STMD was made to control vertical responses of the test structure. Two artificial ground motions and a resonance harmonic load were selected as experimental seismic excitations. Shaking table test was conducted to evaluate control performance of a STMD. Control algorithms are one of main factors affect control performance of a STMD. In this study, a groundhook algorithm that is a traditional semi-active control algorithm was selected. And fuzzy logic controller (FLC) was used to control a STMD. The FLC was optimized by multi-objective genetic algorithm. The experimental results presented that the TMD can effectively reduce seismic responses of the example structures subjected to various excitations. It was also experimentally shown that the STMD can more effectively reduce seismic responses of the example structures conpared to the passive TMD.
        4,000원
        6.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A smart tuned mass damper (TMD) is widely studied for seismic response reduction of various structures. Control algorithm is the most important factor for control performance of a smart TMD. This study used a Deep Deterministic Policy Gradient (DDPG) among reinforcement learning techniques to develop a control algorithm for a smart TMD. A magnetorheological (MR) damper was used to make the smart TMD. A single mass model with the smart TMD was employed to make a reinforcement learning environment. Time history analysis simulations of the example structure subject to artificial seismic load were performed in the reinforcement learning process. Critic of policy network and actor of value network for DDPG agent were constructed. The action of DDPG agent was selected as the command voltage sent to the MR damper. Reward for the DDPG action was calculated by using displacement and velocity responses of the main mass. Groundhook control algorithm was used as a comparative control algorithm. After 10,000 episode training of the DDPG agent model with proper hyper-parameters, the semi-active control algorithm for control of seismic responses of the example structure with the smart TMD was developed. The simulation results presented that the developed DDPG model can provide effective control algorithms for smart TMD for reduction of seismic responses.
        4,000원
        11.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.
        4,000원
        12.
        2018.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of aged water supply pipes have been replaced by the open cut method. However, this method has some limitations because water pipes, in many cases, are buried together with other underground facilities or are buried in the middle of high-traffic roads or in narrow alleyways where boring machines cannot be used. This research developed a pipe bursting device for small diameter pipes that enables pipe replacement without excavating the ground, by the busting of existing buried pipes followed by the traction and insertion of new pipes. As a results of examining the field applicability of the developed device, PE pipes and PVC pipes required the tractive force of 413.65~665.69 kgf and 457.43~791.35 kgf respectively, plus an additional 30 % tractive force per elbow. The proper number of bursting head was demonstrated that the connection of more than 2 heads could secure a stable bending radius of 15D. The developed device can be improved through field experiments involving various pipe types and pipe diameters, as well as presence/absence of elbow, so as to be utilized regardless of diverse variables according to the conditions of the soils surrounding existing pipes.
        4,000원
        13.
        2018.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The guarantee of the performance of the engineered barriers in a geological repository is very important for the long-term safety of disposal as well as the efficient design of the repository. Therefore, the performance of the engineered barriers under repository condition should be demonstrated by in-situ experiments conducted in an underground research laboratory. This article provides a review of the major in-situ experiments that have been carried out over the past several decades at underground research laboratories around the world to validate the performance of engineered barriers of a repository, as well as their results. In-situ experiments to study the coupled thermal-hydraulicmechanical behavior of the engineered barrier system used to simulate the post-closure performance of the repository are analyzed as a priority. In addition, in-situ experiments to investigate the performance of the buffer material under a real repository environment have been reviewed. State-of-the art in-situ validations of the buffer-concrete interaction, and the installation of the buffer, backfill and plug, as well as characterization of the near-field rock and the corrosion of the canister materials are, also performed.
        6,700원
        15.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper investigates seismic performance of a small-sized single story building in Korea. Nonlinear pushover anlaysis is performed to verify shear failure of RC short columns eventually led to performance degradation. Also, nonlinear time history analysis is performed using the same earthquakes from Gyeongju. Similar failure mode was obtained as in the report where a sudden rupture of the RC columns happened.
        4,000원
        16.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        동조액체감쇠기(TLD)는 에너지 소산장치로써 구조물의 동적응답을 제어하기 위해 개발되었다. TLD는 풍하중에 의한 구조물의 응답을 제어에 매우 효과적임을 보여줬다. 그러나 TLD가 설치된 구조물의 지진응답의 제어에 대해서는 충분한 연구가 이뤄지지 않았다. 이 연구의 목적은 TLD가 설치된 구조물에 여러 동조비와 질량비를 대입하여 지진에 대한 TLD의 성능을 도출하는 것이다. 이러한 목적을 위해, 수치해석 연구가 실시되며, 다른 토양 조건 또한 고려되었다. 그 결과 지진하중에 대한 TLD의 성능은 구조물의 고유주기, 감쇠비에 따라 다르게 나타났다. 또한 TLD의 동조비 다르게 나타남을 알 수 있었다.
        4,000원
        17.
        2015.10 구독 인증기관·개인회원 무료
        도로조명은 야간 운전자에게 시각정보를 제공하고 장애물이 보일 수 있게 하는 것이 설치 목적이다. 즉, 도로조명의 궁극적 설치 목적은 야간 운전자에게 전방 장애물 등 위험요소 출현 시 이를 확인하고 회피할 수 있도록 시각정보를 제공하는 것이다. 운전자는 도로 주행 중 필요한 정보의 90% 이상을 시각을 통해 획 득하며, 따라서 야간 도로의 시인성은 교통사고와 밀접한 관련이 있다. 이러한 관점에서 보았을 때 도로 조 명의 설치 및 이를 통한 야간 운전자의 시인성 확보는 야간 교통사고 감소를 위한 가장 이상적인 대안이다. 야간 도로를 주행하는 운전자가 전방의 장애물 확인을 위해서는 일정 수준이상의 노면과 장애물의 밝기, 즉 휘도 차이가 필요하며, 현 도로 조명 기준은 노면 휘도가 높아질수록 장애물과의 휘도차가 커진다는 가정하에 도로 조명의 질적 수준을 규정하고 있다. 이에 본 연구는 운전자의 시야 내 휘도 분포 변화를 묘사한 실내 축 소모형 실험을 통해 정지거리 110m(설계속도 80kph)에서 표준장애물(15×15 cm2)의 확인(perception)이 가능한 노면 휘도와 장애물 휘도의 관계를 규명하고 이를 다양한 조명 조 건의 도로에서 측정된 노면 휘도 및 장애물 휘도와 비교, 분 석하여 도로 조명 기준에서 정의하고 있는 조명의 질적 수준 (노면 휘도)과 시인성의 관계를 검토하였다. 도로에서의 노 면 휘도 및 장애물 휘도는 표준장애물로부터 75m, 110m, 155m(설계속도 60, 80, 100kph에 해당) 거리에서 휘도 측 정 장비(LMK5)를 이용하여 측정되었다(그림 1 참조). 본 실험을 통해 도출된 결과는 그림 2와 같다. X축은 노면 휘도(road surface luminance), Y축은 장애물 휘도(object luminance)이며, 음영으로 표시된 영역은 실내 축소모형에서 도출된 장애물 확인 불가능 영역(시인 불가 영역, invisible area), 이외의 영역은 각각 노면 휘도보다 더 밝은 장애물 휘 도 조건 및 더 어두운 조건에서의 장애물 확인 가능 영역(시 인 가능 영역, visible area)이다. 표시된 점은 도로에서 노면 휘도 조건별로 측정된 노면 휘도와 장애물 휘도의 관계이다. 분석결과 도로에서 측정된 노면 휘도와 장애물 휘도의 관계는 대부분 시인 불가 영역 내에 존재하며, 해당 도로 조명이 현 도로 조명 기준에서 제시하고 있는 최고의 시인성 확보 수준 에 해당하는 M1~M2임을 고려 시 현재 도로 조명 기준에서 가정하고 있는 노면 휘도와 시인성의 관계는 재검토 되어야 할 필요가 있을 것으로 판단된다.
        18.
        2013.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재 분리막 여과 공정은 정수처리에서 많은 관심을 받고 있다. 하지만, 분리막의 효율적인 운영을 위하여 '혼화/응집(/침전)' 등의 전처리 시설 설치로 인한 부지면적 및 비용증가와 5~10%의 배출수 문제가 추가적으로 발생한다. 그래서 본 연구에서는 전처리 공정 없이 지표수(한강)에 대하여 가압식 PVDF 분리막[(주)에코니티]으로 운전하여 성능을 검토하였으며 그 결과 1년 동안 화학적 세정 없이 여과 flux가 1~2.4 m/d (at 25℃)로 운전되었고, 유입원수의 탁도와 상관없이 분리막 처리수의 탁도는 0.05 NTU 이하로 안정되게 유지되었다. 또한, 회수율 제고를 위하여 1개월 동안 가압식 배출수(역세수 + 배수)를 침지식 PE 분리막[(주)에코니티]으로 연계하여 2단 막여과 운영을 한 결과 전체 공정 회수율을 99.5%까지 증가시킬 수 있었다.
        4,000원
        1 2