        1.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The heat transfer characteristics of double-pipe spiral heat exchanger were investigated by various curvature sizes, experimentally. The three different sizes of heat exchanger were made and tested with water as a working fluid to analyze the heat transfer characteristics. The heat transfer rates, overall heat transfer coefficient and pressure drop were analyzed with various heat exchanger sizes (i.e., curvature ratios). As result, the heat transfer rate increased with increasing the size of the heat exchanger as the flow rate increased due to increasing the area size of heat transfer. However, the overall heat transfer coefficient and pressure drop increased with decreasing the heat exchanger size (i.e., increased curvature ratio) due to the enhanced centrifugal force and inertia.
        4,000원
        2.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The shell & tube-type heat exchanger has been frequently used because it shows simple structure, easy manufacturing and wide operation conditions among many heat exchangers. This study aims to investigate the characteristics for thermal flow of coolant and the possibility of damage for tube equipped with shell due to thermal stress. For these purposes, The thermal flow of coolant in tube was simulated using ANSYS-CFX program and thus the behaviors of coolant were evaluated with standard k-ε turbulence model. As the results, as the flow rate of coolant in tube was increased, the mean relative pressure was also increased with quadratic curve, however, as the surface temperature of tube was increased, mean temperature difference was linearly increased. Finally it showed that the damage of tube could be predicted, that is, which tube was the most weak due to thermal stress.
        4,000원
        3.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Test of the operating characteristics and energy saving performance of a container cooling system that reduces the operating energy of a refrigeration system using a loop thermosyphon heat exchanger that removes heat by temperature difference between outdoor and indoor was performed. As a result of the experiments, when the loop thermosyphon and the refrigeration system were operated simultaneously, the refrigeration system operated intermittently by reducing the heat load. As the temperature difference between indoor and outdoor increased, the operating time of the refrigeration system decreased and the energy efficiency rate increased. Energy efficiency rate showed a tendency to increase with increasing temperature difference, and the predicted correlation of energy efficiency rate using the performance of the loop thermosyphon heat exchanger and the refrigeration system was relatively consistent with the experimental value.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a heat exchange system using cooling dehumidification and mixing process was proposed as an experimental study for a white smoke reduction heat exchanger system under winter condition. The white smoke reduction heat exchange system is divided into an EA part, SA part, W part and mixing zone. For the operating conditions, three types (Cases 1, 2, and 3) were selected depending on whether EA fan, SA fan, and A-W heat exchanger were operated. In addition, in order to visualize the white smoke exhausted from the mixing zone, it was photographed using CCTV. In order to investigate the performance of the white smoke reduction heat exchange system, the temperature reduction rate and absolute humidity reduction rate of EA and the heat recovery rate of W were calculated. The temperature change of EA and SA according to operating conditions was most effective in Case 3, and the temperature and absolute humidity at the outlet of the mixing zone were greatly reduced. From the results of the white smoke visualization, it was confirmed that the white smoke generation mechanism was different depending on the operating conditions, and the amount of white smoke generation was greatly reduced.
        4,000원
        5.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 단면설계 및 열 교환 장치 위치 변경을 통해 온실의 구조 변경을 진행하였으며, 선행연구를 통해 개발된 모델을 근간으로 하여 개선 여부에 따른 온실 내부 환경을 예측하였다. 단면형상과 열 교환 장치의 개선 후 유속 변화에 따른 시뮬레이션 분석을 진행하였으며, 이 때 온도와 균일도는 각각 평균 0.65°C, 0.75%p 상승함을 확인하였다. 해석대상 온실과 같은 소규모 온실의 경우 방열관의 난방성능 개선보다 FCU에 의해 형성되는 공기 유동이 균일한 환경 조성에 더 큰 영향을 미치는 것으로 판단된다. 개선 전 ‧ 후 온실에 환기시스템 적용 시 공기 유동 특성 분석을 위해 시뮬레이션 분석을 진행하였다. 공기 유동과 공기령은 유사한 분포를 보였으며, 개선 후 온실의 공기령이 개선 전 온실 대비 18초 낮게 나타났다. 개선 전 ‧ 후 온실 시뮬레이션 분석 결과 전체적으로 개선된 온실에서의 평균온도 및 온도 균일도 상승, 최대편차 감소 등 내부 환경의 균일성이 향상됨을 확인하였다. 선행연구로 개발 된 모델은 형상 변경, 열 교환 장치 위치 변경 등에 따라 변화하는 온실 내부 환경을 예측할 수 있음을 확인하였으며, 온실 설계, 온실 내 난방시스템 설계 등의 분야에 적용 가능할 것으로 판단된다.
        4,000원
        6.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experiments were conducted to evaluate the performance factors such as type of working fluid, flow direction, arrangement and stage of loop thermosyphon heat exchanger for ESS battery container cooling. Pentane showed slightly better performance of the heat exchanger than R-134a as a working fluid. Driving the fan in the suction direction showed improved performance compared to the blowing direction. The two-stage heat exchanger increased the heat transfer rate by more than 30% at the same temperature difference compared to the single-stage heat exchanger. Also, the counterflow flow showed better performance than the parallel flow in the two-stage heat exchanger.
        4,000원
        7.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Experiments were conducted on the operating characteristics and performance of various types of working fluid, filling amount and heat flow rate of a loop thermosyphon for cooling ESS battery container. As results of performance test on various working fluids, HFE-7100 and R-134a as a working fluids showed unstable operating and low performance due to vapor pressure drop, and performance was improved by increasing the number of vapor lines for reducing a pressure drop. In this study, n-pentane was more stable and showed better thermal performance among various working fluids.
        4,000원
        8.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a white smoke reduction simple prediction model of white smoke reduction heat exchange system was developed by using EES. In order to verify the reliability of the EES model, it was compared with the computational results. The developed EES predictive model was used to calculate the temperature and absolute humidity of the mixed SA and EA according to the change of cooling water capacity, flow rate ratio of SA/EA, and SA inlet temperature. The difference between final temperature and absolute humidity at the outlet of the mixer calculated by computational analysis and EES was within 1.4% and 3.6%. As the cooling water capacity and the inlet flow rate ratio increased, and as the inlet air temperature decreased, the temperature and absolute humidity of the mixer decreased. The most influential factor in the white smoke reduction effect among the design variables of the white smoke reduction heat exchange system was the flow rate ratio of SA/EA.
        4,000원
        9.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Heat transfer and pressure drop of horizontal heat exchangers with different configurations and installations numerically characterized. Three different heat exchangers were used and shaped as linear, wavy, and horizontal slinky, respectively. Installation depth was set from 0.5m to 3.0m and pipe spacing was ranged from 0.3m to 2.1m. The results showed that heat transfer rate and pressure drop were increased with the increase in the installation depth and the pipe spacing. The horizontal slinky heat exchanger carried more heat compared to others due to the greater effective heat transfer surface area per installation area. In terms of a ratio of heat transfer rate to pressure drop indicating the system efficiency, the linear heat exchanger performed better than others. On the other hand, the horizontal slinky heat exchanger was the most effective with respect to a ratio of heat transfer rate to installation cost.
        4,000원
        10.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the temperature, the absolute humidity, and the turbulent flow characteristics of exhaust air and supply air in the mixer were studied while changing the shape of the mixer of the white smoke reducing heat exchange system. Using Solidworks, the mixer of the white smoke reduction heat exchange system was created by 3-D model. Also, the mixed flow of supply air and exhaust air inside the mixer under the uniform inlet conditions was computed, using the solidworks flow simulation. Two types of improvement models were selected by using a perforated plate and a guide vane as a turbulent mixing flow control method of the mixer. The mean temperature and mean absolute humidity of the mixture were greatly decreased according to the internal shapes of Case 1, 2, and 3. The temperature difference between the inlet and outlet of the mixer Case 3 was 26℃. The exit temperature and absolute humidity reduction rates of Case 3 were 26.2% and 48.1%, respectively, compared with Case 1.
        4,000원
        11.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        An enthalpy exchange element (EEE) is frequently made of papers, and a concern exists on growth of fungus or bacteria. This concern may be eliminated if polymer membrane is used instead of paper. Furthermore, most existing enthalpy exchangers have cross-flow configuration, which yields lower performance than counter-flow one. In this study, a counter-flow enthalpy exchange element was made using PVDF and cellulose composite. Heat and moisture transfer tests were conducted changing the frontal air flow rate from 150 m 3 /h to 350 m 3 /h at both the heating and the cooling condition. Results showed that the temperature efficiencies were approximately the same independent of the weather condition. Humidity efficiencies at the heating condition, however, were higher than those at the cooling condition. Furthermore, the heat transfer coefficients approached the theoretical value as the flow rate increased. In addition, the vapor transmission rates at the heating condition were higher than those at the cooling condition, probably due to the higher humidity efficiency at the heating condition. Future research will be focused on moisture diffusion characteristics of the composite membrane, which requires further measurements of water holdup, equilibrium adsorption curve, etc.
        4,000원
        12.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the characteristics of the heat flow on SA(supply air) side of the white smoke reducing heat exchange system according to the change of SA velocity were analyzed in the winter condition (outside temperature 0℃). Also, the mixing process of SA and the EA(exhaust air) is presented in the psychrometric chart to confirm the possibility of reducing white smoke. Solidworks flow simulation was used to analyze the heat flow on the heat exchange system under uniform conditions. As the inflow velocity of SA increased, the temperature of SA decreased due to the convective heat transfer improvement due to the active flow in SA system. And the outlet temperature and absolute humidity of the mixing zone decreased significantly. At SA velocity 7 m/s, the outlet temperature and absolute humidity decreased to about 58% and 82%, respectively.
        4,000원
        13.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, effects of reducing white smoke at a heat exchange system for white smoke reduction were studied in the winter season. For this purpose, the heat transfer processes on the exhaust air were investigated by Solidworks. Five wave heat exchangers of air-to-air and air-to-water type were applied for the exhaust air heat recovery. The analytical condition of the exhaust air was fixed and the computational analysis was performed according to the change of SA(supply air) inlet velocities. In order to evaluate the performance of the heat exchange system for white smoke reduction, W(water)/SA recovered capacities and the temperature/ absolute humidity reduction rate were calculated. As SA inlet velocity increased, the exit temperature and absolute humidity of the mixing zone were reduced by up to about 40℃ and 0.12kg/kg respectively. Also, W/SA recovered capacities increased linearly up to about 35%.
        4,000원
        17.
        2018.11 구독 인증기관·개인회원 무료
        중공사 MD 모듈은 DCMD(Direct Contact Membrane Distillation) 방식으로 운전하는 경우 효율저하가 발생하는 이유로 주로 VMD(Vacuum Membrane Distillation) 방식으로 운전되었다. DCMD의 경우 고장을 줄일 수 있으며, 진공 펌프와 TVC 등을 필요로 하지 않아 경제적으로 열효율을 높일 수 있다면 선호되는 방식이다. 열효율을 향상시키기 위한 기초적인 방법으로 멀티모듈의 다양한 배열을 고려하기 위한 모듈 분석을 선행하였다. 이전연구를 통해 개발한 중공사막을 이용하여 모듈을 CFD 분석을 하여 운전방식(내외압, 병류 및 향류)에 따라 온도 및 유량조건별로 분석하였다. 이후 최적 운전방식을 기반으로 열교환효율에 적합한 모듈 배치를 모의하였다. 본 연구는 국토교통부 플랜트연구개발사업의 연구비지원(과제번호 18IFIPC146666-01)에 의해 수행되었습니다.
        18.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently, the cutting oil supply device is not equipped to cool the cutting oil. Therefore, additional cooling device should be connected to cool the cutting oil. This has the disadvantage of increasing the size of the device and reducing its cooling capability. To overcome these shortcomings, cooling coils are applied to the outside of the cutting oil filtering device to develop a heat exchanger filter for simultaneous coolant filtering and cooling to improve the compactness of the cutting oil supply device and cooling capability of the cutting oil. For the development of heat exchanger filter, flow and heat transfer analysis were performed. Due to the small heat transfer area of 10 cooling coils, less heat exchange occurred. In the 20 cooling coils, the coolant cooling coils prevented smooth flow of the cooling oil in the heat exchanger filter. The cooling efficiency of the 15 cooling coils were best, and the cooling temperature decreased non-linearly as the supply flow rate of the cutting oil increased.
        4,000원
        19.
        2018.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the demand for high-speed and high-precision machining increases, the need for cooling and filtering of cutting oil is high. A new concept of coolant heat exchange filter is developed by installing cooling coil through which refrigerant(R410-a) passes through the coolant filtering device. For structural safety evaluation of the heat exchanger filter for cutting oil suppling device of machine tool, thermal stress and vibration analysis were performed using ANSYS program. The results of structural and thermal stress analyses have led to the conclusion that the cooling system has structural stability. From modal analysis, first natural frequency is 12.37 hz and deformation is 22.041 mm. Sixth natural frequency is 26.887 hz and deformation is 25.563 mm.
        4,000원
        20.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, the white reduction system was designed and manufactured to evaluate the performance of a heat exchange system using a wave heat exchanger. The reducing effect of white smoke and the amount of heat recovered from cooling water were investigated experimentally using the cooling and dehumidifying method. The white smoke reduction system consists of two parts; the generating part and the reducing part of white smoke. Experimental conditions on EA(exhaust air) and SW(supply water) were fixed. And the outlet temperature and absolute humidity of EA were measured according to inlet velocity of SA(supply air). The outlet temperatures and absolute humidities of EA gradually decreased as inlet velocities of SA increased. From the experimental results, we can see that the absolute humidity reduction rate of EA was max. 84%, and the heat recovery rate of SW was max. 42%.
        4,000원