        검색결과 19

        1.
        2024.03 구독 인증기관·개인회원 무료
        In recent years the tunnel construction is increasing worldwide because of development of science and technology and increasing of transportation demand. Tunnels are complex structures normally rectangular cross section or semicircular and constructed to connect between different sections of roads. Because of the importance, the construction and extension of road tunnels are also continuously increasing along with the development. According to data from the Korea Expressway Corporation, the number of road tunnels, which was 1,332 in 2010, increased rapidly by about 2.1 times over 10 years to a total of 2,742 in 2020. The extension of road tunnels is also on the trend of increasing, with a total of 945 km in 2010 reaching 2,157 km in 2020. The benefits of a double-deck tunnel are emphasized, particularly in terms of construction cost and convenience. This tunnel design incorporates a central slab, dividing the tunnel into upper and lower spaces. The versatility of a double-decker tunnel is evident in its ability to accommodate various uses for both levels. For instance, the upper level can function as vehicle roads, while the lower level can be designated for train tracks. In this study, the effect of RWS and modified hydrocarbon fire curve was applied to the concrete tunnel bracket through simulation to analyze the temperature after the fire occurrence.
        4.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교량에서의 화재는 최근까지도 빈번하게 발생되고 있으며, 특히 케이블교량에서 화재가 발생될 시 케이블에 높은 온도상승으로 인해 케이블에 손상 및 파단이 발생될 수 있다. 본 연구에서는 케이블교량에서 발생될 수 있는 화재 시나리오를 설정하였다. 또한 실물차량 화재실험 결과를 토대로 화재강도모델을 제안하여 대상교량 케이블의 열전달 해석을 수행하였다. 해석 결과 단면적이 작은 케이블에서 더 높은 온도상승이 발생되며, 유조차를 제외한 차종의 경우 내화 성능 기준을 초과하지 않는 결과를 나타내었다. 유조차 화재의 경우 갓길에서 발생될 때 최소 단면적 케이블에서 내화 성능 기준을 초과하는 결과 를 보이며, 기준을 초과하는 케이블의 높이는 약 14m로 나타나 이에 따른 대책 및 내화 보강의 필요성을 확인하였다. 본 연구결과를 통해 케이블교량에서 화재가 발생될 때 케이블의 온도변화에 대한 간접적인 평가가 가능한 것을 확인하였으며, 향후 화재 발생 시 바람에 영향을 고려한 열전달 해석과 케이블의 온도상승 시 교량의 사용성에 대한 추가적인 연구가 필요할 것으로 판단된다.
        4,000원
        5.
        2018.04 구독 인증기관 무료, 개인회원 유료
        In the event of an outbreak of fire in an underground subway station, the speed of movement slows down as many people try to evacuate at once and bottlenecks might begin to occur in some locations, potentially resulting in catastrophic accidents. This study aims to analyze egress routes depending on, among other factors that influence evacuation in the event of an outbreak of fire, the characteristics of occupants and the initial points of fire using the GongEgress simulation program. The simulation result shows that the evacuation time of the vulnerable users is found to take 18% longer than that of ordinary people, and the transfer passageways have lower survival probability compared to that of the platforms. Through the analysis of the results, the structural features of the underground subway station and the points of fire are proved to be the major factors that determine the survival probability of the occupants. Therefore, safety training for passengers through conducting fire drills at the station or fire accident simulations can be established in the evacuation route and plan for reaction at the station or fire accident simulations. Key Words : Underground subway station, Fire accident simulations, Evacuation route, Vulnerable users, Transfer station
        4,600원
        6.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 화재에 노출된 구조물의 역학적 거동을 평가하기 위한 기반연구로서 화재 유동해석과 열응력해석의 통합 프레 임워크를 확립하고 이를 강재와 콘크리트로 이루어진 대표체적에 적용한 결과를 제시하였다. 먼저 Fire Dynamics Simulator(FDS)를 이용해 임의의 화재곡선으로 모델링되는 화원으로부터 구조물 표면까지 유동해석을 실시하였다. 이를 통 해 구조물 표면에서 시간에 따른 온도 분포를 계산하였고, 이 결과를 비선형 열응력해석에 경계조건으로 적용하였다. 이후의 과정은 화재의 성장 또는 감소에 따라 구조물 표면온도의 변화를 반영하는 열전달해석과 구조해석으로 이루어진다. 제시한 통합 프레임워크에 의해 화재 구조해석을 수행한 결과, 강재와 콘크리트의 대표체적 모두 동일한 하중이 작용할 때 상온 조 건에서는 탄성 거동을 보였지만 화재로 인한 온도 조건을 고려할 경우 소성 거동을 보였다. 이는 구조물이 화재에 노출되는 경우 설계하중보다 작은 하중에서도 한계상태에 이를 수 있다는 것을 의미하며, 따라서 원전구조물이나 교량과 같은 중요 사회기반구조물의 설계 시 구조물의 화재거동 평가가 고려되어야 한다고 할 수 있다.
        4,000원
        7.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 화재에 노출된 구조물의 역학적 거동을 평가하기 위한 기반연구로서 화재 유동해석과 열응력해석의 통합 프레임워크를 확립하고 이를 강재와 콘크리트로 이루어진 대표체적에 적용한 결과를 제시하였다. 먼저 Fire Dynamics Simulator(FDS)를 이용해 임의의 화재곡선으로 모델링되는 화원으로부터 구조물 표면까지 유동해석을 실시하였다. 이를 통해 구조물 표면에서 시간에 따른 온도 분포를 계산하였고, 이 결과를 비선형 열응력해석에 경계조건으로 적용하였다. 이후의 과정은 화재의 성장 또는 감소에 따라 구조물 표면온도의 변화를 반영하는 열전달해석과 구조해석으로 이루어진다. 제시한 통합 프레임워크에 의해 화재 구조해석을 수행한 결과, 강재와 콘크리트의 대표체적 모두 동일한 하중이 작용할 때 상온 조건에서는 탄성 거동을 보였지만 화재로 인한 온도 조건을 고려할 경우 소성 거동을 보였다. 이는 구조물이 화재에 노출되는 경우 설계하중보다 작은 하중에서도 한계상태에 이를 수 있다는 것을 의미하며, 따라서 원전구조물이나 교량과 같은 중요 사회기반구조물의 설계 시 구조물의 화재거동 평가가 고려되어야 한다고 할 수 있다.
        4,000원
        8.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 화재에 노출된 철근콘크리트 구조에 대한 수치해석 모델을 제시하고, 기존의 자료 및 설계 규준과의 비교를 통해 구조물의 설계 시 고려 사항에 대해 제안하고 있다. 수치해석은 비정상 열전달 해석과 비선형 구조해석의 두 단계로 수행되며, 비정상 열전달 해석을 통해서 얻어진 화재시간에 따른 단면 온도분포를 바탕으로 비선형 구조해석하여 부재의 상태에 대한 정보를 얻게 된다. 이때, 철근콘크리트의 재료모델을 화재진행상태(Under-Fire)와 화재종료 후 냉각상태(After-Cooling)로 나뉘어 해석수행하여 각각의 재료상태에 따른 거동의 변화를 살펴본다. 해석된 결과는 여러 구조물에 대해 기존의 실험결과와 비교하여 검증하고, 설계 규준과의 비교를 통해 화재 시 구조물의 안전성에 대해 고찰하였다.
        4,500원
        9.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 교량 하부에서 발생된 화재에 대한 강-콘크리트 합성구조의 전반적·국부적 손상평가를 위한 수치해석적 연구이다. 수치해석의 정확성 및 효율성을 높이기 위해 구성재료의 과도 비선형 열적·열역학적 특성이 고려된 열-구조 연성병렬 화재해석 기법이 제안되고, ANSYS solver와 연결되어 해석이 수행되며, 표준화재시험과 비교·검증된다. 검증된 해석기법을 통해 국내에서 발생된 부천고가교 합성구조에 대한 화재손상해석이 수행된다. 해석결과 강박스 거더의 하부 플랜지 및 복부의 경우 임계온도를 초과하였고 구조적 처짐과 변형 형상이 화재사고 결과와 비교적 잘 일치하였다.
        4,000원
        10.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fire disasters have frequently happened in concrete structures, which resulted in severe structural damages and unsafety. In this case, the method which had evaluated the safety of damaged structures was often unaccepted from most of stakeholders and engineers. The objective of this study is to develope the procedure and method to be able to determine the safety. Numerical simulation was applied to produce the maximum temperature and temperature distribution. Nextly, temperature propagation analysis was performed to plot temperature gradients at each depth and location. The material strength curve versus temperature was applied to determine the safety of concrete structures damaged by fire. The maximum temperature should be calibrated considering real fire records ; magnitude, intensity, situation etc. The results shows that the selected procedure and method was applicable and practical.
        4,000원
        12.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 1편에서 얻어진 온도분포와 박리시간이력을 이용하여 지하박스구조물의 열응력을 산정하고 이에 기반한 열모멘트를 산청하였다. 또한 이때의 온도분포를 바탕으로 구조물의 열적비선형성을 고려한 극한모멘트를 산정하여 구조물의 내하력을 산정하였다. 그 결과 상부슬래브의 부모멘트 구간은 단면의 온도경사에 의해서 발생하는 열모멘트에 의해 지배받는 것으로 나타났다. 반면 정모멘트 구간은 박리에 의해 화염에 노출된 철근의 항복응력에 의해 지배받는 것으로 나타났다.
        4,000원
        13.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 전력구나 공동구와 같은 지하 콘크리트박스구조물의 화재발생시 온도분포와 박리거동에 대한 수치해석을 수행하였다. 해석에 사용된 온도장은 터널화재에 사용하는 화재곡선을 기본으로 하고 화재시 내부공간에 대한 열유체해석을 수행하여 온도분포를 결정하였다. 박리거동은 탈수화도를 따라 콘크리트의 온도가 기준값에 도달하였을때 발생하는 것으로 하였다. 이때 박리가 일어난 요소를 제거하고 경계조건과 요소망을 재생성하여 해석을 반복수행하였다. 3개의 화재 시나리오에 따라 해석을 수행하였고, 해석결과는 각 시나리오별로 타당한 박리거동을 보여주었다. 각 시나리오에 따른 구조물의 내하력은 본 논문의 2편에서 산정되었다.
        4,000원
        14.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 화재시 매입형 합성기둥의 높은 축력비에 따른 내화성능을 알아보기 위해 유한요소해석 프로그램(ANSYS)을 통한 해석을 실시하였다. 온도에 따른 응력-변형률 곡선을 적용하여 ASTM E 119 가열곡선과 축력비 0.7, 0.6, 0.5에 따른 과도상태 열전달해석 및 정적구조해석을 실시하였으며, 해석조건과 동일한 조건에서의 재하가열실험을 실시하였다. 또한, 기준식(Eurocode 4)에 따라 가열시간에 따 른 합성기둥의 공칭압축강도를 산정하고, 축력비로 나타내어 해석값 및 실험값과 비교하였다. 해석 및 실험과 기준(Eurocode 4)을 통해 가열시 간에 따른 단면별 온도분포를 확인하고, 이에 따른 내화성능을 측정해 비교분석하였다. 유한요소해석 결과 축력비 0.5에서는 내화시간 180분 으로 실험값과 유사한 값이 도출된 반면, 축력비 0.6, 0.7에서 내화시간 150분과 60분이 도출되어 실험결과에 비해 다소 높은 결과가 도출된 것을 알 수 있었다. 그리고 기준식(Eurocode 4)에 따라 산정한 축력비에 따른 내화시간이 실제 실험값에 비해 다소 낮게 평가하고 있다는 것을 확인하였다. 그러나 축력비 0.7에서는 기준(Eurocode 4)이 실험값에 비해 다소 높게 평가하는 것을 확인하였다. 이에 따라 고축력에서의 매입형 합성기둥의 내화특성(시간-축력비 관계)을 확인하고, 도출된 매입형 합성기둥의 실험 및 해석데이터를 Eurocode기준의 검증의 자료로 활용할 수 있을 것으로 보인다.
        15.
        2014.02 서비스 종료(열람 제한)
        화재 안전 설계의 주요 목적 중 하나는 화재 발생시 안전하게 대피하는데 있다. 화재 안전 요건에서는 대피 경로 및 탈출구에 관한 양적인 조건을 요구하고 있으나, 실제 대피 시스템의 활용에 있어서는 평가가 어렵다. 쇼핑센터, 경기장, 혹은 학교와 같이 인구가 밀집되는 대형 건물에서는, 요건을 준수하는 것만으로는 안전을 확보할 수 없다. 인구가 과잉 밀집된 곳에서는 수없이 많은 사고가 발생한다. 컴퓨터 대피 시뮬레이션을 통해 이런 재난을 야기하는 가능한 상황을 예측할 수 있다. 기존 대부분의 대피 시뮬레이션 방법은 화재 진행 및, 화재-사람간 상호작용을 고려하지 않는다. 그러나, 대피자의 대피 경로 선택에 있어서 화재 상태는 가장 중요한 요인 중 하나이다. 화재의 확산 또한 대피자가 위험 상황을 감지하고 이에 대응하는데 영향을 미친다. 반면에, 대피자가 화재 확산에 영향을 미칠 수도 있다. 대피자가 방화 문을 닫는지 여부는 화재 확산에 중대한 변수가 될 것이다. 또한 수동 소화기를 사용함으로써 다양한 위험 상황을 제거할 수 있다.본 연구에서는, 대피자간 및 화재-대피자간 상호작용을 고려한 FDS+Evac 라는 NIST (미 국립 표준 기술 연구소)가 개발한 화재 역학 시뮬레이터를 기반으로 FDS의 화재 관련 자료를 이용하여 화재-대피자간 상호작용을 모형화하였다
        16.
        2014.02 서비스 종료(열람 제한)
        FDS(Fire Dynamics Simulation)은 미국의 NIST가 연소 및 건축불의 화재를 수치해석적으로 해석하기 위해 1980년대부터 개발을 시작해 현재까지 version 6 까지 발표하면서 성능과 기능을 개선해 오고 있는 공개용 코드이다. 하지만 version 5 까지 FDS 코드가 사용한 LES난류모델은 가장 고전적인 형태의 LES모델을 사용하였기 때문에 대형 건축물의 화재해석에 많은 오차가 발생하고 있음이 꾸준히 지적되어왔다. 이로 인해 최근에 발표된 version 6에는 기존의 LES모델을 포함하여 3개의 LES모델이 추가되어 정량적 신뢰성을 강화한 것으로 평가되고 있다. 본 연구에서는 FDS에서 제공하고 있는 4개의 LES 난류모델에 대하여 평판유동 및 평판위의 입방체 주위의 압력분포를 분석하고 비교하여 각 난류모델의 특성과 신뢰성을 검증하고자 하였다.
        17.
        2014.02 서비스 종료(열람 제한)
        본 연구는 다중이용시설 중에서 노래방과 같이 재실자 밀도가 높이며 무창층 실들로 구성된 복잡한 구조의 내부를 가진 곳에서의 화재 및 연기의 확산이 재실자의 피난에 미치는 영향에 관하여 연구하였다. 실물 실험을 통한 실험 데이터를 수치해석 결과와 비교 검토하여 재실자 피난의 여러 상황들을 수치 해석적 방법으로 검토하였다. 수치 해석적 접근을 통하여 화재 시 다중이용시설에서 인명 피해를 줄일 수 있는 방법에 대하여 기초적인 연구를 수행하였다.
        18.
        2013.04 서비스 종료(열람 제한)
        Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the dense building and suitability of fire risk assessment were reviewed
        19.
        2012.05 서비스 종료(열람 제한)
        In this study, warehouse under bridge was analysed for evaluating the effects of the fire source using FDS code. As a results, most of the bridges were vulnerable to spalling of concrete and it is confirmed that strength of concrete and steel rebars reduced differently according to the type of fire source. The book combustion has the strongest intensity, and the bridge higher than 30m can ensure thesafety for the fire in the case of the rubber combustion.