검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 89

        41.
        2018.04 서비스 종료(열람 제한)
        This paper presents a study on the adhesive strength testing of self-adhesive waterproofing/anti-corrosion sheet used for waterproofing of the large diameter steel pipe interior of water treatment facilities. After the sheet has been applied, similar physical and chemical immersion conditions are simulated in the testing to determine the effects of deterioration through adhesion strength testing.
        42.
        2017.09 서비스 종료(열람 제한)
        In this paper, the slope adhesion force of the developed green slope soil was evaluated by simulating rainfall intensity. From the results, the slope failure didn't occur at all conditions. As the slope angle increases, however, the damage decreased. The developed green slope soil is considered to have sufficient adhesion capacity to the slope.
        43.
        2017.04 서비스 종료(열람 제한)
        This research developed the fiber pullout impact test machine to investigate interfacial bond strength between fiber and cement based matrix under high velocity. To achieve the goal, firstly the existing pullout test machines were investigated. And then, these drawback were comprehended. Finally, Fiber pullout impact test machine base on strain energy frame impact machine was proposed.
        44.
        2017.04 서비스 종료(열람 제한)
        The maximum bond strength of PCS-coated rebar with ultra high-early strength cement and EVA at polymer-cement ratio of 80%, curing ages of 7-day, and coating thickness of 100㎛ is about 1.32 and 1.38 times respectively, the strength of uncoated rebar and epoxy-coated rebar. It is also high bond strength at coating thicknesses of 75㎛ and 100㎛ compared with 150㎛ and 250㎛. It is apparent in this study that the coating thickness is very important factors to improve the bond strength of PCS-coated rebar to cement concrete.
        45.
        2017.04 서비스 종료(열람 제한)
        In this study, cement mortar (KS F 4042) used for repairing concrete structures was evaluated for compressive strength and bond strength according to the mixing ratio of polymer. From the experimental results, it was confirmed that as the polymer content increases, the bond strength properties increase, but the compressive strength decreases slightly at a certain rate.
        46.
        2017.04 서비스 종료(열람 제한)
        This study examined the safety and reliability of code equations for the bond strength of FRP bars with concrete using test data compiled from the different sources. ACI equations have a better agreement with test results, whereas high overestimation is observed in JSCE equations.
        47.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This research developed the fiber pullout impact test machine to investigate interfacial bond strength between fiber and cement based matrix under high velocity. To achieve the goal, firstly the existing pullout test machines were investigated. And then, these drawback were comprehended. Finally, Fiber pullout impact test machine base on strain energy frame impact machine was proposed.
        48.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        The maximum bond strength of PCS-coated rebar with ultra high-early strength cement and EVA at polymer-cement ratio of 80%, curing ages of 7-day, and coating thickness of 100㎛ is about 1.32 and 1.38 times respectively, the strength of uncoated rebar and epoxy-coated rebar. It is also high bond strength at coating thicknesses of 75㎛ and 100㎛ compared with 150㎛ and 250㎛. It is apparent in this study that the coating thickness is very important factors to improve the bond strength of PCS-coated rebar to cement concrete.
        49.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        In this study, cement mortar (KS F 4042) used for repairing concrete structures was evaluated for compressive strength and bond strength according to the mixing ratio of polymer. From the experimental results, it was confirmed that as the polymer content increases, the bond strength properties increase, but the compressive strength decreases slightly at a certain rate.
        50.
        2016.10 서비스 종료(열람 제한)
        Change in the adhesion strength between AR-glass textile and concrete was performed through pull-out test with longitudinal (load direction) and transverse development length. In case of longitudinal development length, adhesion performance was not shown. But in case of transverse, adhesion performance was increased according to the increasing transverse textile length.
        51.
        2016.10 서비스 종료(열람 제한)
        Recently, Advanced water treatment facilities with Ozone are being introduced domestically. However, waterproofing/corrosion prevention construction method of concrete structure for existing advanced water treatment makes waterproofing/corrosion prevention materials and concrete deteriorated because of strong oxidation of ozone. Therefore, in this study, It was evaluated in ozone resistance and bond strength of metal spraying coating.
        52.
        2016.10 서비스 종료(열람 제한)
        Result of test, adhesive strength improved 7% in 4℃ when test object used vibrating roller than unused vibrating roller. In case of 20℃, it improved 16.9%. Therefore, using vibrating roller is useful in construction of waterproofing layer because the test showed that using vibrating roller has excellent adhesive strength han unused it.
        53.
        2016.04 서비스 종료(열람 제한)
        This study is the adhesion strength of the sprayed metal in accordance with a proportion ratio of the Zn-Al. Results showed the most excellent adhesion strength for metal spraying Al100 For the metal spraying Zn100, ZnAl85, ZnAl95 exhibited a similar level of adhesion strength results.
        54.
        2016.04 서비스 종료(열람 제한)
        Concrete and bar of bond performance used in the most RC structure. So Through recent studies and experiments for the attachment behavior of concrete and steel issues and evaluate their characteristics. Bar are two was used as the D13 and D16. The Bond stress was increased result of experiment by placing a variable length according to the Bond stress formulation according to the diameter and reinforced.
        55.
        2015.10 서비스 종료(열람 제한)
        Because significant difference between normal concrete and fiber reinforced ultra-high strength concrete under tension and compression, bond behavior also have significant difference. Bond behavior may affect to the flexural behavior and shear behavior of reinforced concrete beams. Especially, because ultra high strength concrete usually be used as precast members, bond between concrete and steel rebar should be safely and accurately evaluated for design. In this study, bond test results about ultra high strength fiber reinforced concrete were investigated and evaluated with various types of prediction methods, especially for empirical equations.
        56.
        2015.10 서비스 종료(열람 제한)
        Bond strength of PCS-coated rebar is better than that of uncoated rebar and epoxy-coated rebar. It is also high bond strength at curing ages of 7-day or less, and coating thicknesses of 75 μm and 100 μm. The maximum bond strength of PCS-coated rebar at curing age of 3-hour is almost same as that of curing age of 1-day and 7-day. The maximum bond strength of PCS-coated rebar with EVA at polymer-cement ratio of 100%, and coating thickness of 100 μm is about 1.23 and 1.29 times respectively, the strength of uncoated rebar and epoxy-coated rebar. It is apparent that the curing age, coating thickness and polymer cement ratio are very important factors to improve the bond strength of PCS-coated rebar to cement concrete. We can havebasic information that it can replace epoxy coated rebar by the PCS-coated rebar with curing age at 3-hour and coating thickness of 100 μm.
        57.
        2015.07 KCI 등재 서비스 종료(열람 제한)
        용융아연도금(galvanizing)은 콘크리트 구조물의 철근 부식 문제를 해결하기 위해 사용된다. 용융아연도금 철근 콘크리트 보의 부착강도 영향에 대한 자료는 거의 없는 실정이다. 따라서, 이 연구의 목적은 용융아연도금철근이 콘크리트 보의 부착강도에 미치는 영향을 파악하는 데 있다. 용융아연도금철근을 사용한 부재와 일반철근을 사용한 부재의 구조실험을 통하여 겹침이음 거동과 부착강도 특성을 비교하였다. 실험변수로써 철근의 용융아연코팅 유무, 철근 직경과 겹침이음 길이를 고려하였다. 용융아연도금 철근콘크리트 보의 균열 및 파괴 특성을 파악하였다. 용융아연도금철근 콘크리트 보의 겹침이음부 휨 거동특성은 일반철근 콘크리트 보의 겹침이음부 휨거동과 유사한 것으로 나타난다. 또한, 용융아연도금철근의 사용은 일반철근을 사용할 때에 비해 콘크리트 보의 부착강도에 불리한 영향을 미치지는 않는 것으로 나타났다.
        58.
        2015.05 KCI 등재 서비스 종료(열람 제한)
        이 연구에서는 초고성능 콘크리트 (UHPC)와 보통 콘크리트 (NSC)간 계면부착강도에 관한 연구를 수행하였다. UHPC를 보수⋅보강재 로 활용하기 위한 기존의 부착강도에 관한 연구와 달리, UHPC를 프리캐스트 합성부재로 활용하기 위한 연구에 초점을 맞추었으며, 여기 에 영향을 미칠 수 있는 다양한 요인에 대하여 검토하였다. 기존 연구들을 분석한 결과, UHPC-NSC 계면 부착강도에 영향을 미칠 수 있는 요인으로는 계면의 형상, 합성 전 UHPC의 경화 진행상태, 합성 전 UHPC의 수분 흡수상태, 그리고 합성 후 양생장소와 같이 크게 4가지 로 구분되었다. 계면의 형상을 변수로 한 실험에서는 형상에 따라 각기 다른 파괴모드가 나타났으며, 기존 연구에서 확인되지 않았던 거칠 게 처리한 UHPC 계면 일부가 파괴되는 새로운 파괴모드가 발견되었다. 합성 전 UHPC의 경화진행 상태가 부착강도에 영향을 미치는 것 으로 나타났으며, 이러한 영향은 부착 파괴모드에 따라 다르게 나타났다. 또한, 합성 전 UHPC의 수분상태가 부착강도에 영향을 주었으며, UHPC의 양생방법에 따라 서로 상반되는 결과를 보였다. 마지막으로, 합성한 시편의 양생조건 역시 계면 부착강도에 영향을 미친다는 것 을 확인하였다.
        59.
        2015.04 서비스 종료(열람 제한)
        Because significant difference between normal concrete and fiber reinforced ultra-high strength concrete under tension and compression, bond behavior also have significant difference. Based on the finite element analysis of bond test specimens, crack initiation and propagation process were investigated. Analysis results have been validated with test results and crack initiation stress was investigated.
        60.
        2015.04 서비스 종료(열람 제한)
        The volume expansion of corroded steel reinforcement produces tensile stress on the surrounding concrete, which causes splitting cracking of concrete cover, and deteriorates the service ability and durability of reinforced concrete(RC) members. In addition, since the steel corrosion induces bond strength degradation between steel bar and concrete, the structural performance of RC members can be deteriorated significantly. In this study, the theoretical study was performed to probe the mechanism of the bond strength reduction due to steel corrosion. The bond strength between corroded steel bar and concrete was calculated by mathematically formulating the expansion pressure of corroded steel reinforcement. The proposed model was verified by comparing with the existing test results, and it showed that the proposed model estimate the bond strength reduction of corroded RC elements very closely.
        1 2 3 4 5