        1.
        2024.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the performance evaluation of steel dampers was conducted based on existing research results. The test variables are cross-sectional shape and lateral deformation prevention details. As a result of performance tests according to cross-sectional shape, the circular cross-section was evaluated to be superior than the rectangular cross-section in terms of envelope, stiffness reduction, and energy dissipation capacity. In addition, it was evaluated that the rectangular cross-section where lateral deformation occurs can be restrained by lateral deformation prevention details, thereby improving strength and deformation capacity.
        4,000원
        2.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.
        4,000원
        3.
        2023.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study presents a dry precast concrete (PC) beam-column connection, and its target seismic performance level is set to be emulative to the reinforced concrete (RC) intermediate moment resisting frame system specified in ACI 318 and ASCE 7. The key features include self-sustaining ability during construction with the dry mechanical splicing method, enabling emulative connection performances and better constructability. Test specimens with code-compliant seismic details were fabricated and tested under reversed cyclic loading, which included a PC beam-column connection specimen with dry connections and an RC control specimen. The test results showed that all the specimens failed in a similar failure mode due to plastic deformations in beam members, while the hysteretic response curve of the PC specimen showed comparable and emulative performances compared to the RC specimen. Seismic performance evaluation was quantitatively addressed, and on this basis, it confirmed that the presented system can fully satisfy all the required performance for the intermediate RC moment resisting frame.
        4,000원
        4.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The collapse of reinforced concrete (RC) frame buildings is mainly caused by the failure of columns. To prevent brittle failure of RC column, numerous studies have been conducted on the seismic performance of strengthened RC columns. Concrete jacketing method, which is one of the retrofitting method of RC members, can enhance strength and stiffness of original RC column with enlarged section and provide uniformly distributed lateral load capacity throughout the structure. The experimental studies have been conducted by many researchers to analyze seismic performance of seismic strengthened RC column. However, structures which have plan and vertical irregularities shows torsional behavior, and therefore it causes large deformation on RC column when subjected to seismic load. Thus, test results from concentric cyclic loading can be overestimated comparing to eccentric cyclic test results, In this paper, two kinds of eccentric loading pattern was suggested to analyze structural performance of RC columns, which are strengthened by concrete jacketing method with new details in jacketed section. Based on the results, it is concluded that specimens strengthened with new concrete jacketing method increased 830% of maximum load, 150% of maximum displacement and changed the failure modes of non-strengthened RC columns.
        4,000원
        5.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the case of columns in buildings with soft story, the concentration of stress due to the difference in stiffness can damage the columns. The irregularity of buildings including soft story requires retrofit because combined load of compression, bending, shear, and torsion acts on the structure. Concrete jacketing is advantageous in securing the strength and stiffness of existing members. However, the brittleness of concrete make it difficult to secure ductility to resist the large deformation, and the complicated construction process for integrity between the existing member and extended section reduces the constructability. In this study, two types of Steel Grid Reinforcement (SGR), which are Steel Wire Mesh (SWM) for integrity and Steel Fiber Non-Shrinkage Mortar (SFNM) for crack resistance are proposed. One reinforced concrete (RC) column with non-seismic details and two columns retrofitted with each different types of proposed method were manufactured. Seismic performance was analyzed for cyclic loading test in which a combined load of compression, bending, shear, and torsion was applied. As a result of the experiment, specimens retrofitted with proposed concrete jacketing method showed 862% of maximum load, 188% of maximum displacement and 1,324% of stiffness compared to non-retrofitted specimen.
        4,000원
        6.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 직관적인 적용 및 응용이 가능한 FRP 구속 콘크리트의 재료모형을 반영하는 단면해석 기법을 적용하여 FRP 보강 RC 교각의 성능 증진효과 분석을 수행하였다. 분석 대상 교각은 국내 시설물 내진성능평가 지침인 「기존 시설물 (교량)의 내진성능 평가요령 해설 및 예제집(국토해양부, 2015)」에서 제시하고 있는 예제 모델을 대상으로 하였으며, Lam and Teng. (2003)의 FRP 구속 콘크리트 재료 모델을 활용하여 단면해석을 수행하였다. 미국 콘크리트 학회(ACI, American Concrete Institute)의 구조물 FRP 보강 매뉴얼인 ACI440.2R-17에서 제시하고 있는 구조물 보강용 FRP 소재 물성 제원을 활용하였으며, 구조물 FRP 보강 설계 세부 조항을 따랐다. 국내 내진성능 평가요령에 제시된 교각의 축방향 철근 겹침이음을 조항을 고려하여 기존 교각의 콘크리트 재료 물성을 가정하여 매개변수 연구를 수행하였으며, FRP 보강재 소재별 보강 겹수를 고려하여 FRP 보강 RC 교각의 휨 성능 증진 효과 분석을 수행하였다.
        4,000원
        7.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, interest in OSC(Off Site Construction) is increasing due to the trend of a decrease in skilled workers and an increase in labor costs. In this regard, PC(Precast Concrete) is being reviewed for apartments, the most common type of housing in Korea. As the biggest concern for PC apartment houses, civil complaints such as inter-floor noise and leakage were presented. In this study, the details of the joints were reviewed based on the past cases of PC apartments, and the details of the recently constructed or planned PC apartments were investigated. Through this, the leakage path in the past was analyzed through the existing research literature and data. And wall type RC and PC apartment joint leakage test was performed and we found the needs for a detail of waterproof steps, sealant. Also, joint details were investigated for a rahmen type apartment housing under construction. At last, A discussion was conducted on the direction for a detailed proposal of an improved joint in the future.
        4,000원
        8.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study classifies the compositional methods of power shoulder jackets from 1980 to the present. It analyzes the relevance of jacket details according to how the power shoulder changes and its compositional methods by era. The research subdivides shoulder compositional techniques into seven, based on shoulder variation, sleeve variation, and the body and sleeve combination. The researcher investigates the frequency and trends of composing shoulders and analyzes details pertaining to the silhouette, jacket length, collar shape, and front closure. The most common method of shoulder composition is an angular shoulder variation. The others are a rounded shoulder variation, puffed sleeve, sleeve variation using pattern incision, raglan and kimono sleeves, and a shoulder variation that expanded the angle and width. The frequency differs slightly for each era. The relationship between shoulder compositional methods and details of power shoulder jackets is statistically significant, showing period-related differences. The homogeneity analysis results reveal that the shoulder composition of power shoulder jackets, the times, and details fall into distinct groups. This analysis shows that the silhouette, length, collar, and front closure of the power shoulder jacket differ depending on the power shoulder’s compositional methods. Moreover, the shape of the power shoulder jacket is distinctly different. One can use this data to help develop the power shoulder jacket design by reflecting the details of shoulder compositional methods and changing trends over time.
        5,200원
        9.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진 하중에 의해 피해를 받는 교각의 보강을 위한 방법론과 다양성에 대한 연구가 활발히 진행되었지만, 단자유도에 대한 비선형 정적 분석에 대한 연구가 주로 수행되었으며, 교각을 구성하는 재료적 특성만이 변수로 간주되었다. 그러나, 교 각의 기하학적 요소와 보강 수단의 관계성에 관한 연구는 수행되지 않았다. 이에 본 연구에서는 CFRP 재킷을 사용하여 캘리포 니아에 존재하는 비 내진 상세 콘크리트 교량 교각을 보강하고 형상 변화에 따라 (교각 직경, 전단 경간 비, 보강 재킷의 길이) 교량 교각의 지진 취약성 곡선 도출하고 내진 성능을 평가하였다. 상기의 목표를 달성하기 위해 Opensees 프로그램를 사용하여 문헌에서 인용할 수 있는 실험체를 모델링하고 반복 하중을 가하여 결과 비교를 통해 해석방법의 적절성을 결정하였다.
        4,000원
        10.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The detailed names and meanings of Korean stone pagodas have not yet been properly studied or clearly defined. Therefore, an aim of this report is to compare the detailed names of Korean, Chinese, and Japanese stone pagodas by focusing on content used previously by Ko and his students and content that is currently in use (i.e., since the Japanese colonial era). Additional objectives are to assess the significance of these names and propose an appropriate detailed draft regarding names of stone pagodas. The discussion will proceed by dividing the stone pagoda into three parts: the podium, main structure, and finial. First, the content in Luo Zhewen(羅哲文)’s “Ancient pagodas in China(中國古塔)” (1985) is considered; then, “朝鮮の石塔” (1943)—published by during the Japanese colonial era—is explored. The thesis written by Yu-Seop Ko regarding Korea’s first stone pagoda and the content in “A Study of Korean Pagodas(朝鮮塔婆의 硏究)” (1948), which contains Yu-Seop Ko’s posthumous works published in book form by his student Su-Yeong Hwang, Heu-Kyoung Kim are examined. to pagodas that are used today, are compared and reviewed. Since Korea, China, and Japan influence each other, pagoda-related terms are shared to some extent. In this study, these were applied to stone pagodas, and names used thus far that have not drawn criticism were studied and proposed as suitable alternatives.
        4,600원
        11.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 테러에 대한 위험성의 증가로 대중들의 폭발 피해에 대한 인식이 증가하였다. 우리나라에 방폭 설계에 대한 기준이 미흡하며, 현재 적용하고 있는 방폭 설계도 정적해석으로 건물의 안정성 및 경제성을 위해 방폭 설계를 개발해야 하는 상황 이다. 또한 지진 발생 증가로 내진 설계 의무화가 확대된 가운데 방폭 설계를 하지 않고 내진 설계를 적용한 부재의 방폭 성능을 판단을 연구한다. 현재 보편적인 폭발 하중의 해석 방법은 UFC 3-340-02 매뉴얼을 참고하는 것이다. UFC 3-340-02 매뉴얼을 통한 폭발 하중의 특성을 적용하고 KBC 2016의 내진 상세를 적용한 보를 등가 단자유도 시스템으로 변환하여 폭발 저항 성능을 연구하였다. 보통, 중간, 특수 모멘트 골조의 연성 능력에 대한 최대 처짐을 고려하여 폭발물의 이격 거리를 통해 평가하여 내진 상세 적용 시 폭발 저항 성능이 향상된다는 것을 입증하였다.
        4,000원
        12.
        2017.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the seismic performance of solid reinforced concrete columns with triangular reinforcement details using nonlinear seismic analysis. The developed reinforcement details are economically feasible and rational, and facilitate shorter construction periods. By using a sophisticated nonlinear finite element analysis program, the accuracy and objectivity of the assessment process can be enhanced. Solution of the equations of motion is obtained by numerical integration using Hilber-Hughes-Taylor (HHT) algorithm. The proposed numerical method gives a realistic prediction of seismic performance throughout the input ground motions for several column specimens. As a result, developed triangular reinforcement details were designed to be superior to the existing reinforcement details in terms of required performance.
        4,000원
        13.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, the fiber reinforced polymers (FRP) materials have been recognized as advanced materials for bridge construction. The FRP bridge deck system has advantages to construct rapidly, its durability. The FRP bridge decks have accepted as a method of deteriorated reinforced concrete bridge deck replacement. For application, design method details and connections for FRP bridge decks will be provided. In this paper, the design method, deck design and connections details on FRP decked precast, prestressed concrete girder bridges is presented. In this study, the design method of efficient connection between FRP deck and concrete girder is proposed with composite action. The schematic of proposed modular FRP panel deck-to-concrete girder connection is also presented, which is the flexible hybrid shear connection included steel reinforcements and FRP tubes. The FRP deck-to-concrete girder hybrid connection system should be improved with further refinement and experimental program. Finally, it is hoped that this paper will be guideline for research and development on this subject field for researchers and engineers
        4,000원
        14.
        2016.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In regions of low-to-moderate seismicity, various types of lap splices are used for longitudinal reinforcement of columns at the plastic hinge zones. The seismic performance of such lap spliced columns, such as strength, deformation capacity, and energy dissipation, is affected by material strengths, longitudinal re-bar size, confinement of hoops, lap splice location, and lap splice length. In the present study, cyclic loading tests were performed for columns using three types of lap splices (bottom offset bar splice, top offset bar splice, and splice without offset bend). Lap splice length(40db and 50db) was also considered as test parameters. Ties with 90-degree end hooks were provided in the lap splice length. The test results showed that strength, deformation capacity, and energy dissipation of columns significantly differed depending on the details and the length of lap splices. The bottom offset bar splice showed high ductility and energy dissipation but low strength; on the other hand, the top offset bar splice and the splice without offset bend showed high strength but moderate ductility and energy dissipation.
        4,000원
        15.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reinforced concrete shear walls with deficient reinforcement details are tested under cyclic loading. The deficiency of reinforcement details includes insufficient splice length in U-stirrups at the ends of horizontal reinforcement and boundary column dowel bars found in existing low- to mid-rise Korean buildings designed non-seismically. Three test specimens have rectangular, babel and flanged sections, respectively. Flexure- and shear-controlled models for reinforced concrete shear walls specified in ASCE/SEI 41-13 are compared with the flexural and shear components of force-displacement relation extracted separately from the top displacement of the specimen based on the displacement data measured at diverse locations. Modification of the shear wall models in ASCE/SEI 41-13 is proposed in order to account for the effect of bar slip, cracking loads in flexure and shear. The proposed modification shows better approximation of the test results compared to the original models.
        4,300원
        16.
        2016.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the performance of hollow precast segmental bridge columns with reinforcement details for material quantity reduction. The proposed triangular reinforcement details are economically feasible and rational, and facilitate shorter construction periods. The precast segmental bridge columns provides an alternative to current cast-in-place systems. We tested a model of hollow precast segmental bridge columns under a constant axial load and a quasi-static, cyclically reversed horizontal load. We used a computer program, Reinforced Concrete Analysis in Higher Evaluation System Technology (RCAHEST), for analysis of reinforced concrete structures. The used numerical method gives a realistic prediction of performance throughout the loading cycles for hollow precast segmental bridge column specimens investigated. As a result, proposed reinforcement details for material quantity reduction was equal to existing reinforcement details in terms of required performance.
        4,200원
        17.
        2016.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the seismic performance of new hollow reinforced concrete (RC) bridge piers with triangular reinforcement details. The developed triangular reinforcement details are economically feasible and rational, and facilitate shorter construction periods. We tested a model of new hollow RC bridge piers with triangular reinforcement details under a constant axial load and a quasi-static, cyclically reversed horizontal load. We used a computer program, Reinforced Concrete Analysis in Higher Evaluation System Technology (RCAHEST), for analysis of RC structures. The used numerical method gives a realistic prediction of seismic performance throughout the loading cycles for several hollow pier specimens investigated. As a result, developed triangular reinforcement details for material quantity reduction was equal to existing reinforcement details in terms of required performance.
        4,200원
        18.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various non-seismic tie details are frequently used for one- and two-story small buildings because the seismic demand on their deformation capacities is not relatively significant. To evaluate the effects of the non-seismic tie details on the seismic performance of reinforced concrete columns, six square columns with a cross section of 400 × 400 mm and six rectangular columns with a cross section of 250 × 640 mm were tested. The anchorage details at both ends and spacing of tie hoops, along with the cross-sectional shape and the magnitude of axial load, were considered as the primary test parameters. Test results showed that square columns had higher stiffness and lower lateral deformation rather than rectangular columns. Both lap spliced tie and U-shaped tie provided comparable or improved seismic performance to 90° hook tie in terms of maximum strength, ductility, and energy dissipation. The predicted curves with modeling parameters in ASCE41-13 were conservative for test results of lap spliced tie and U-shaped tie specimens since plastic behavior after flexural yielding could not be considered. For economical design, ASCE41-13 should be revised with various test results of tie details.
        4,200원
        19.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate the behavior characteristics of new hollow reinforced concrete (RC) bridge pier sections with triangular reinforcement details and to provide the details and reference data. Among the numerous parameters, this study concentrates on the shape of the section, the reinforcement details and the spacing of the transverse reinforcement. Additional eight column section specimens were tested under quasi-static monotonic loading. In this study, the computer program, named RCAHEST (Reinforced Concrete Analysis in Higher Evaluation System Technology), was used. A innovative confining effect model was adopted for new hollow bridge pier sections. This study documents the testing of new hollow RC bridge pier sections with triangular reinforcement details and presents conclusions based on the experimental and analytical findings.
        4,300원
        20.
        2015.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the performance of new hollow reinforced concrete (RC) bridge pier sections with triangular reinforcement details. The proposed triangular reinforcement details are economically feasible and rational and facilitate shorter construction periods. A model of pier sections with triangular reinforcement details was tested under quasi-static monotonic loading. As a result, proposed triangular reinforcement details was equal to existing reinforcement details in terms of required performance. In the companion paper, the parametric study for the performance assessment of new hollow RC bridge pier sections with triangular reinforcement details is performed.
        4,300원