검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 23

        1.
        2022.10 구독 인증기관·개인회원 무료
        The reliable information on the hydraulic characteristics of rock mass is one of the key site factors for design and construction of deep subsurface structures such as geological radioactive nuclear waste disposal repository, underground energy storage facility, underground research laboratory, etc. In order to avoid relying on foreign field test technology in future projects, we have independently designed and made integrated type main frame, 120 bar waterproof downhole sonde, and 1,200 m wireline cable winch through a series of R&D activities. They are core apparatuses of the Deep borehole Hydraulic Test System (DHTS). Integration of individual test equipment into a single main frame allows safe and efficient work in the harsh field condition. The DHTS was developed aiming primarily for constant pressure (head) injection test and pulse test in deep impermeable rock mass. The maximum testing depth of the DHTS is about 1,050 m from the surface. Using this system, it is possible to make precise stepwise control of downhole net injection pressure in less than 2.0 kgf/cm2 with dual hydraulic volume controller and also to inject and measure the very low flow rate below 0.01 l/min with micro flow rate injection/control module. Over the past two years, we have successfully completed more than 50 in situ hydraulic tests at 5 deep boreholes located in the Mesozoic granite and sedimentary rock regions in Korea. Among them, the deepest testing depth was more than 920 m. In this paper, the major characteristics of the DHTS are introduced and also some results obtained from the high precision field tests in the deep and low permeable rock mass environment are briefly discussed.
        2.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 20,000 톤급 해양플랜트 상부구조물(Topside)의 플로트오버 설치작업을 위해 개발된 수동형 갑판 지지 프레임 (Deck support frame)의 구조설계에 대해 다양한 실험계획법을 이용한 최소중량설계와 민감도 평가의 비교연구를 수행하였다. 수동형 갑판 지지 프레임의 주요 구조부재의 두께 치수 변수는 설계인자로 고려하였고, 응답치는 중량과 강도성능으로 선정하였다. 최소중량설계와 민감도 평가의 비교연구에 사용한 실험계획법은 직교배열설계법, Box-Behnken 설계법, 그리고 Latin hypercube 설계법이다. 실험계획법의 설계공간 탐색의 근사화 성능을 평가하기 위해 반응표면법을 각 실험계획법 별로 생성하여 근사화 정확도 특성을 검토하였다. 또한 최소 중량설계를 위해 최상 설계안의 결과로 부터 실험계획법의 특성에 따른 수치계산 비용, 중량감소 효과 등을 평가하였다. 수동형 갑판 지지 프레임의 구조설계에 대해 Box-Behnken 설계법이 가장 적합한 설계 결과를 나타내었다.
        4,200원
        4.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존 내진보강시스템의 문제점을 개선하기 위한 듀얼프레임형 내진보강시스템은 기존구조체, 외부보강체, 댐퍼로 구성된다. 듀얼시스템은 지진발생시 주기차이로 인하여 기존구조체와 외부보강체 사이에서 상대변형이 발생되고 이를 댐퍼가 대응하여 안정적으로 지진에너지를 흡수하여 내진성능을 확보한다. 본 논문에서는 듀얼시스템의 구조성능을 분석하기 위하여 정적반복가력실험을 수행한다. 실험결과, 듀얼시스템 실험체는 비보강 실험체와 유사한 손상상태를 나타내었다. 이와 같이 나타난 이유는 정적실험 시 기존구조체를 강제 이력 시켰기 때문이다. 하지만 하중-변형관계곡선에서 핀칭현상이 완화되는 것으로 나타났고, 안정적인 이력거동을 통하여 비보강 실험체에 비해 5.3배 더 많은 에너지를 흡수하였다. 또한 동일한 층간변형각 및 누적 변형에 대해서도 더 많은 에너지를 흡수할 수 있음에 따라 듀얼시스템을 적용할 경우 내진성능을 향상시킬 것으로 판단된다. 또한 듀얼시스템을 실무에 적용하기 위해서는 설계프로세스 등에 대한 연구가 필요하며, 본 논문을 추후 연구의 기초자료로 제시하고자 한다.
        4,000원
        6.
        2018.04 구독 인증기관 무료, 개인회원 유료
        In this study, to develop the basis of damage prediction system for abutment type rigid-frame bridge, measurement data is generated by artificially expressing damage by Abaqus, a commercial structural analysis program, and applied to machine-learning. The rigid-rame bridge structural analysis model is expressed as closely as possible to the actual bridge condition considering the specification, damage expression, analysis method, boundary condition, and load. CNN(Convolutional Neural Network), one of the neural network algorithm, is used for machine-learning and accuracy is confirmed when there was no measurement error as a result of machine learning.
        3,000원
        7.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to make a generalized analytical based on the proposed experiments on reinforced concrete(RC) partially infilled frames by U-type precast concrete(PC) wall panels with openings. RC frame and PC wall panels were connected with different strengths. Therefore, we developed modified strut-tie model(STM) with two seismic retrofitting specimens and conducted a nonlinear analysis by using a computer analysis program. Based on the test results, truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix- A. As a result, the modified STM analysis results were very similar to the experimental results. As a result of the load-displacement curve comparison, the failure load were similar within 5∼17% of error range. In particular, the experimental results and the results of modified STM analysis show that the failure behavior almost matched.
        4,200원
        8.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cyclic loading test was performed on the partially infilled reinforced concrete(RC) frames by L-type precast concrete(PC) wall panels with the connections of two different strength. Based on the results of experimental test, the nonlinear analysis was practiced with modified strut-tie model(STM) method by using a computer program. Truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix-A. Modified STM was designed with two ways according to the test result. PC wall panel and RC frame were assumed to composite when push loading applied. The PC and RC structures were also assumed to behave non-composite and those two structures connected with link(top connector) when pull loading applied. The connection was designed by using elastic link of program. The results of analytical modified STM process generally conform to the experimental results. The failure load and the failure mode of the specimens could be predicted using modified STM. The ratio of failure load measured in specimens to analytical values were between 0.83∼1.16. The member or connection which was failed in experiment yield in the results of modified STM. The failure mode perfectly matched.
        4,500원
        9.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
        4,500원
        10.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
        4,200원
        11.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대공간 스페이스 프레임 구조물은 구조물의 목적 및 설계자의 의도와 함께 다양한 형상으로 구성될 수 있으며, 다양한 구조물 형식에 적용될 수 있다. 그러나 이러한 대공간 스페이스 프레임 구조물의 최적의 부재크기나 형상은 구조 엔지니어의 경험과 반복적인 해석 그리고 시행착오적인 방법 때문에 그 결정이 쉽지 않다. 따라서 본 논문에서는 설계자가 구조물의 최적 형상을 선택할 수 있는 방안을 제시하기 위해 먼저 타원형 및 볼트복합형과 같은 다양한 유형의 스페이스 프레임 구조물이 선정되며, 절점, 좌표 및 부재 생성을 위한 형상생성방법이 고려된다. 또한 스페이스 프레임 구조의 최적설계 절차에서 각 절점 좌표는 높이 변화나 링의 개수에 따라 변하게 되므로 최적설계 과정에서 절점파 부재의 자동생성기법이 적용된다. 다음으로 형상생성방법을 기반으로 한 형상생성모듈은 구조물의 최적화 단계에 앞서 설계자가 원하는 형상을 생성해주는 모듈이며, 최적화 단계에서는 해석 모듈과 최적화모듈이 연계된다. 마지막으로 예제 모델을 통해 형상생성방안 및 최적설계 방안의 효율성을 검토한다.
        4,000원
        12.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 큰느타리버섯 재배사의 환경조절을 최적화하고 시스템 설계에 대한 기초자료를 얻기 위하여 진주인근에 위치한 샌드위치패널을 이용한 영구형 재배사 2동을 대상으로 2003년 11월부터 2005년 10월까지 재배사 내부에서 측정한 환경인자들을 중심으로 검토하였다. 실험지역의 외기온은 평년의 것과 대체로 비슷한 경향을 보였다. 시스템 변경전의 경우, 동절기에는 전체적으로 설정온도보다 낮게 유지되었고, 또 최상부와 최하부의 최대온도 편차도 5.1℃ 정도로 상층이 가장 높게 나타났다. 그러나 시스템의 변경 후의 경우, 난방시 대체로 설정온도 범위에서 조절되는 경향을 보였고, 공기정체나 온도층의 역전현상이 나타나지 않았다. 상대습도는 시스템 변경 후, 80~100% 정도의 범위로서 권장상대습도 범위에 있었다. 전체 재배기간동안 탄산가스 농도는 400~3,300mg·L-1 정도의 범위에 있었다. 조도는 권장조도보다 전반적으로 낮게 유지되고 있음을 알 수 있었고, 산도는 대체로 일정하게 유지되었다. 수확량은 전체적으로 일정하지 않았고, 포기재배의 경우가 상대적으로 등외품이 적었으며, 증수 효과도 있었다. 전력소비량은 계절별로 일정한 경향이 있음을 알 수 있었고, 하절기보다 동절기에 전력소비량이 현저히 많은 것을 확인 할 수 있었다.
        4,500원
        13.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : T_{L}=(0.20H_{h}+0.05H_{i})/sqrt{B}-0.42 단변 방향 :T_{S}=(0.07H_{h}+0.12H_{i})/sqrt{B}-0.40
        4,500원
        14.
        2000.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공급수가 원판틀형 모듈에 잘 분포될 수 있는 역삼투형 하우징(HY)을 개발하여 설계 제작하였으며 상용화된 Rochem(RC)시스템과 투과성능을 비교하였다. 자체 개발한 HY시스템은 RC시스템에 비하여 투과유속이 약간 떨어지는 반면, NaCl 배제율은 전반적으로 높았다 원판틀형 모듈인 type A, B, C에 대한 투과유속 및 배제율을 NaCl, sucrose 및 butanol 수용액으로 측정하였다. NaCl 및 sucrose의 경우, type C, A, B의 순으로 투과성능이 우수하였으나 butanol의 경우는 type B, C, A 순이었다. Type A에 대한 type C의 butanol 투과유속은 농도가 감소할수록 그리고 28 bar 범위내에서 운전압력이 증가할수록 향상되었다.
        4,000원
        15.
        1997.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        직선형(Type 1), 곡선형(Type 2) 및 병렬형 (Type 3) baffle을 설치한 역삼투용 판틀형 모듈을 설계 제작하였으며 NaCl과 sucrose 용액을 각각의 모듈에 공급하여 용액농도 및 운전압력등이 분리특성에 미치는 효과를 측정하고 각 모듈의 특성치를 비교하였다. 운전압력 35bar, 원료 공급유량 6 l/min 이내의 운전조건에서 Type 3가 투과선속 및 배제율 측면에서 가장 우수하였다. NaCl 수용액의 경우, Type 1에 대한 Type 2 및 3의 투과선속 향상율은 운전압력이 증가함에 따라서 감소하였다: 1wt% NaCl 수용액에 대한 Type 3 투과선속 향상율은 10bar 근처에서 약 100%이었으나 35bar에서는 약 10%로 감소하였다. 그러나 sucrose 수용액에 대한 Type 2 및 3의 투과선속 향상율은 농도 및 운전압력에 따라서 크게 변화하였다. 또한 Type 3의 경우, 원료용액의 공급속도 변화에 따른 투과선속의 의존성은 거의 선형적으로 나타났으며 이는 baffle이 존재하지 않는 난류영역에서 보다 큰 값이었다.
        20,000원
        16.
        1996.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        평판형 모듈 설계의 최적화를 목적으로 feed 흐름 조건에 따른 feed 온도 및 유속분포를 예측할 수 있는 모델식을 확립하였고 모델 모사를 통해 흐름 조건들이 온도 분포에 끼치는 영향들을 조사하였다. 모델내의 유체의 Re 크기가 커지면 채널 두께방향으로의 유속 구배가 커질 뿐 아니라 투과물 증발을 위한 에너지원인 feed 흐름 속도가 커져 물질 및 열흐름이 증가하여 투과물 증발로 인한 feed 온도 강하가 증어든다. 반면에 채널 간격이 작아지면 feed 흐름량이 상대적으로 작아져 급격한 온도 강하를 야기시킨다. Re 크기에 따른 feed 온도 변화는 실험결과와 일치함이 관찰되었다.
        4,000원
        17.
        1995.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        NaCl과 sucrose 용액을 역삼투용 워난틀형 모듈에 공겁하여 투과실험하였으며 Kimura-Sourirajan[8]이 제안한 방법으로 분리성능을 분석하였다. 사용한 분리막의 순수투과계수는 압력에 무관하게 2.17 × 10-6 (gmol/cm2 -sec-bar)로 일정하게 유지되었다. Sucrose 용액의 농도분극화 현상은 NaCl 용액보다 심각하였으며 40bar 이상에서는 압력이 증가함에 따라서 오히려 투과선속이 감소하였다. 용질 배제율은 NaCl 수용액의 경우 압력이 증가함에 따라서 감소하였으나 sucrose 수용액의 경우는 압력에 따라서 배제율도 증가하였다.
        4,000원
        18.
        2019.10 서비스 종료(열람 제한)
        본 연구에서는 비내진상세를 가지는 중⦁저층 R/C 건물의 1층 골조를 제작하여 무보강 실험체에 대한 구조실험을 실시하였다. 실험결과 실험체는 부재각 1.33%에서 전단파괴를 나타내어, 비내진상세를 가지는 R/C 건물의 내진성능에 관한 중요한 자료를 획득하였다. 본 연구에서는 간주형 좌굴방지 강재 슬릿댐퍼 시스템을 개발하였으며 내진보강효과를 검증하기 위하여 구조실험에 선행하여 상기 국내 비내진상세 RC 골조 실험결과를 기반으로 비선형해석을 실시하였다.
        20.
        2016.04 서비스 종료(열람 제한)
        The development and verification of seismic performance possible role as moment resisting frames connection is needed because rigidly-connected and assembled lightweight steel frame system is not easy to obtain the seismic performance at the same time.
        1 2