본 논문에서는 충격파 형태의 폭발 하중을 받는 부재의 소성 범위를 고려한 SDOF 해석의 수정계수를 개발하였다. SDOF 해석의 수 정계수는 MDOF 해석 결과 값을 비교하여 도출하였다. SDOF 해석에 영향을 미치는 매개변수로 부재의 경계조건, 폭발 하중 지속시 간과 고유주기 비를 선정하였다. 수정계수는 탄성 하중-질량 변환 계수를 기준으로 산정하였다. 수정계수 곡선은 상한, 하한 매개변수 경계 사이에 있도록 타원 방정식을 이용하여 도출하였다. 서로 다른 단면과 경계조건을 가지는 예제에 수정계수를 적용한 결과 SDOF 해석의 오차율이 15%에서 3%로 감소하였다. 본 연구의 결과는 수정계수를 적용하여 SDOF 해석의 정확도를 높임에 따라 폭발 해석 에 널리 활용될 수 있다.
In this study, theoretical analyses are performed to investigate the characteristics of the static and dynamic stiffness of a nonlinear vibration isolator system. The vibration isolator system is modeled as an equivalent nonlinear oscillator. Based on the model, the static equilibrium and frequency response solutions are obtained with the variations of external static load and/or system parameters. It is shown that the static stiffness of the nonlinear vibration isolator tends to be hardened with the increase of external static load, which prevents the occurrence of excessively large deflection. This static stiffness-hardening effect is more remarkable with a larger spring constant ratio. The dynamic stiffness is also strengthened when the spring constant ratio increases, which enlarges the force transmissibility and reduces the isolation frequency bandwidth. Thus, the static stiffness- hardening improves the robustness of the nonlinear vibration isolator, whereas the dynamic stiffness-hardening rather degrades its performance. Thus, the opposite tendency of the static and dynamic stiffness-hardening effects should be considered in the design process of the nonlinear vibration isolator.
본 연구는 딥러닝을 위한 비선형 변환 접근법을 사용하여 Single-lap joint의 접착 영역을 조사하기 위한 진동 응답 기반 탐지 시스템 을 제시한다. 산업 혹은 공학 분야에서 분해가 쉽지 않은 구조 내에 보이지 않는 부분의 상태와 접착된 구조의 접착 부위 상태를 알기 어려운 문제가 있다. 이러한 문제를 해결하기 위해 본 연구는 비선형 변환을 이용하여 기준 시편의 진동 응답으로 다양한 시편의 접착 면적을 조사하는 탐지 방법을 제안한다. 이 연구에서는 CNN 기반 딥러닝으로 진동 특성을 파악하기 위해 비선형 변환을 적용한 주파 수 응답 함수를 사용했고 분류를 위해 가상의 스펙트로그램을 사용했다. 또한, 제시된 방법을 검증하기 위해 알루미늄, 탄소섬유복합 재 그리고 초고분자량 폴리에틸렌 시편에 대한 진동 실험, 분석적 해, 유한요소해석을 수행했다.
In this paper, the effect of a dynamic vibration absorber to suppress the response of a base excitation vibration system composed of a cubic nonlinear spring and a friction damper is investigated. And the dynamic absorber consists of a linear spring and a viscose damper. The mathematical models of these systems are governed by second order nonlinear ordinary differential equations. The response characteristics of the system are analyzed using the slowly changing phase and amplitude(SCPA) method, which is one of the averaging methods. As a function of the friction force ratio, It was obtained the locking frequency at which the relative motion starts was obtained, and the regions where the locking occurred. The displacement transmissibility was investigated according to the change of the design parameter, and the optimal design parameters could be found to minimize the displacement transmissibility.
The connection of the steel structure serves to transmit external forces to the main components. The same is true for the behavior of modular systems composed mainly of steel or composite members. In this study, the joint performance of the composite and steel modules proposed was evaluated. The analytical models of the two joint types were constructed and were subjected to cyclic loading to assess the safety and the energy dissipation capacity of the joint types. The analysis results of the joints showed that the joints of the modular systems remain stable when the joint rotation reached the seismic performance limit state of the 0.02 rad required for steel intermediate moment frame. It was also observed that the joint of the composite modular system showed higher energy dissipation capacity compared with the steel modular system.
Recently, the incidence and magnitude of earthquakes have been continuously increasing. NFPA 13 requires that hydroponics fire extinguishing system pipelines apply seismic isolation. Stainless steel joints have been newly developed to replace these seismic isolation joints. Therefore, in this study, a nonlinear finite element model of a pipeline with Stainless Power Joint was developed based on experimental data, and finite element analysis was performed by applying hydrostatic pressure and cyclic loading.
This paper is a study on the nonlinear behavior of polyhedron curved space roof as building structures of quasicrystal system. The quasicrystal is made up of two kinds of parallel hexahedrons, and all the line elements of the parallelepiped have the same length. The quasicrystal design grid dome has a pentagonal symmetry and all members have the same length. This paper described form of design gird dome, and showed the analysis conditions. Also, The displacement-load curve is shown through the analysis and we grasped the flow of the load and forces through analysis of design grid dome applied quasicrystal system.
이 연구에서는 3축 방향 지반운동이 작용하는 지반-구조물 상호작용계의 비선형 지진응답 해석을 수행한다. 비선형 거동이 예상되는 구조물과 지반의 근역은 비선형 유한요소에 의해 모형을 구성한다. 기하학적 형상과 재료 성질이 균일하고 선형 거동을 가정하는 원역지반은 무한 영역으로의 에너지 방사를 정확히 고려할 수 있는 3차원 perfectly matched discrete layer에 의해 수치 모형을 구성한다. 이와 같은 지반-구조물 상호작용계의 수치모형을 사용하여 3축 방향 지반운동이 작용하는 비선형 지진-구조물 상호작용계의 지진응답해석을 수행한다. 3축 방향 지반운동이 작용하는 경우에는 입력 지반운동의 특성에 따라 시스템의 응답이 우세하게 발현되는 방향이 존재하고 그 수준 또한 정밀한 지진응답해석을 통해 산정하여야 한다. 이 연구의 해석기법은 구조물과 지반의 재료 비선형 거동, 기초와 지반 경계면에서의 경계 비선형 거동 등 다양한 비선형 지반-구조물 상호작용 해석에 확장 적용할 수 있을 것이다.
이 연구에서는 3축 방향 지반운동이 작용하는 지반-구조물 상호작용계의 비선형 지진응답 해석을 수행한다. 비선형 거동 이 예상되는 구조물과 지반의 근역은 비선형 유한요소에 의해 모형을 구성한다. 기하학적 형상과 재료 성질이 균일하고 선 형 거동을 가정하는 원역지반은 무한 영역으로의 에너지 방사를 정확히 고려할 수 있는 3차원 perfectly matched discrete layer에 의해 수치 모형을 구성한다. 이와 같은 지반-구조물 상호작용계의 수치모형을 사용하여 3축 방향 지반운동이 작용 하는 비선형 지진-구조물 상호작용계의 지진응답해석을 수행한다. 3축 방향 지반운동이 작용하는 경우에는 입력 지반운동의 특성에 따라 시스템의 응답이 우세하게 발현되는 방향이 존재하고 그 수준 또한 정밀한 지진응답해석을 통해 산정하여야 한 다. 이 연구의 해석기법은 구조물과 지반의 재료 비선형 거동, 기초와 지반 경계면에서의 경계 비선형 거동 등 다양한 비선 형 지반-구조물 상호작용 해석에 확장 적용할 수 있을 것이다.
본 연구에서는 에너지 소산형 감쇠기가 설치된 철근콘크리트 구조물의 지진응답 저감효과를 확률적으로 평가하기 위하여 지진취약도 함수를 도출하였다. 가속도민감 영역과 속도민감 영역에 속하는 대표 고유주기를 갖는 비선형 단자유도 시스템으로 모델링된 철근콘크리트 구조물을 대상으로 강도와 강성의 불확실성을 고려하였다. 원구조물에 다양한 강성과 감쇠를 갖는 변위의존형 감쇠기를부가하여 비선형시간이력해석을 수행하였으며, 해석결과의 통계를 바탕으로 로그정규분포 형태의 지진취약도 함수를 도출하였다. 원구조물의 종류별로 감쇠기의 설계변수에 따른 지진취약도 함수의 변화를 검토하고 이를 통해 손상확률의 저감효과를 분석하였다.
A vehicle suspension system performs two functions, the ride quality and the stability, which conflict with each other. Among the various suspension systems, an active suspension system has an external energy source, from which energy is always supplied to the system for continuous control of vehicle motion. In the process of the linearization for the nonlinear active suspension system, the frequency dependent damping method is used for the exact modelling to the real model. The pressure control valve which is controlled by proportional solenoid is the most important component in the active suspension system. The pressure control valve has the dynamic characteristics with 1st order delay. Therefore, It's necessary to adopt the lead compensator to compensate the dynamics of the pressure control valve. The sampling time is also important factor for the control performances. The sampling time value is proposed to satisfy the system performances. After the modelling and simulation for the pressure control valve and vehicle dynamic, the performances of the vehicle ride quality and the stability are enhanced.
본 논문에서는 비선형 지진격리교량의 최적 설계 방법을 제시하였다. 최적설계를 위한 목적함수로는 교각과 지진격리장치의 파괴확률을 고려하였으며, 상충하는 두 목적함수를 동시에 최적화하는 다수의 해를 효율적으로 검색하고자 유전자 알고리즘에 기반한 다목적 최적화기법을 도입하였다. 또한, 최적화 과정에서 요구되는 다수의 비선형 시간이력해석을 수행하지 않고도 교량의 확률적 응답을 효율적으로 예측할 수 있는 추계학적 선형화 방법을 접목하였다. 제시하는 방법의 효율성을 검증하기 위한 수치 예로서 실제 교량인 남한강교를 고려하였고, 제안하는 방법과 기존 비선형 시간이력해석을 이용한 생애주기비용 기반 설계법을 각각 적용하여 내진성능을 비교하였다. 내진성능을 비교한 결과, 제시하는 방법이 기존의 비용에 기반한 최적설계보다 우수한 성능 및 경제성을 보임을 검증하였다. 또한, 다양한 지진하중에 대해서도 제안된 방법이 보다 개선된 성능을 보임을 확인하였다.
본 논문은 Total Lagrangian(TL)과 Updated Lagrangian(UL)을 사용하여 구조물 하부에 케이블을 연결하고, 그 케이블에 인장력을 가하여 구조물의 처짐을 제어하는 언더텐션 시스템에 있어서 케이블의 인장력에 따른 구조물의 처짐 거동의 변화와 각 부재력을 비교함으로서 언더텐션 시스템의 효율성을 검증하는데 있다. 일반적인 빔과 거더로 이루어진 구조와는 달리 언더텐션 시스템에서는 상부에서는 하중을 하부 케이블의 인장력을 이용하여 그 하중을 양 단부로 전달하게 된다. 언더텐션 시스템은 스트럿의 개수와 길이, 케이블의 초기 인장력의 크기에 따라서 그 효과가 다르게 나타날 수 있다. 또한 케이블이 설치된 장스팬 구조의 경우, 그 거동에 있어서 비선형성적 거동이 크게 나타나게 된다. 따라서 본 논문에서는 선형과 비선형해석 결과를 비교함으로써 비선형해석의 필요성에 대하여 논의하고자 한다.
비선형 구조계의 확률론적 지진해석 방법 중 대표적인 것은 지진 재해도 수준에 해당하는 입력지반운동 모델을 사용한 시간이력을 수행하여 그 응답의 확률분포를 예측하는 것이다. 이 연구에서는 널리 사용되고 있는 두 가지 입력지반운동 모델에 따른 구조계 응답의 분포특성 및 파손확률의 차이와 그 원인을 분석한다 입력지반운동 모델로는 실제 지진기록을 배율 조정하여 사용하는 배율조정 입력지반운동과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용하는 스펙트럼 맞춤 입력지반운동 두 가지를 고려한다. 동일한 지진재해도 수준을 고려한 해석결과 설계 응답스펙트럼에 상응하는 인공 지진기록을 사용한 입력지반운동 모델은 실제 지진기록을 배율 조정한 입력지반운동 모델보다 평균적으로 응답을 크게 평가하였고 이로 인해 파손확률 또한 더 큰 것으로 나타났다 이러한 경향은 연약한 지반에서 더욱 현저한 것으로 나타났다. 이러한 입력지반운동 모델에 따른 파손확률의 차이는 스펙트럼 맞춤 입력지반운동의 목표로 사용된 도로교 설계기준의 설계 응답스펙트럼이 실제 지진기록의 응답스펙트럼보다 장주기로 갈수록 응답을 크게 평가하도록 보수적으로 만들어졌기 때문인 것으로 나타났다.
인접 구조물의 지진응답 제어를 위한 비선형 감쇠시스템의 최적 설계 방법에 관하여 연구하였다. 최적 설계를 위한 목적 함수로는 구조물의 응답과 감쇠기의 총 사용량을 고려하였으며, 상충하는 두 목적함수를 합리적인 수준에서 동시에 최소화하는 해를 구하기 위하여 유전자 알고리즘에 기반한 다목적 최적화 방법을 도입하였다. 또한, 최적화 과정에서 요구되는 비선형 시간이력해석을 수행하지 않고도, 비선형 이력감쇠기로 연결된 구조물의 지진응답을 효율적으로 평가하기 위하여 추계학적 선형화 방법을 접목하였다. 제시하는 방법의 효율성을 검증하기 위한 수치 예로서 20층과 10층의 인접 빌딩을 고려하였으며, 두 빌딩을 연결하는 비선형 감쇠시스템으로는 입력전압의 크기에 따라 변화하는 감쇠성능을 보이는 MR 감쇠기를 도입하였다. 제시하는 방법을 통하여 MR 감쇠기의 각 층별 최적 개수 및 감쇠용량을 결정할 수 있었으며, 이는 일반적인 균등분포 시스템에 비해 유사한 제어성능을 보이면서도 훨씬 경제적이었다. 또한, 인접구조물간 충돌에 대하여도 확률적으로 안정적인 거동을 보임을 검증하였으며, 제시하는 방법이 준능동 제어시스템의 최적 배치를 결정하기 위한 설계문제에도 적용할 수 있음을 보였다.
횡저항 시스템의 설계는 구조 엔지니어의 경험과 노하우에 의존하는 경향이 크다. 또한 건물의 보유성능을 평가하여 설계과정에 적절히 반영할 수 있는 방법이 제시되어있지 않다. 따라서 본 연구에서는 구조물이 실제 보유하고 있는 유효보유성능(available full capacity, R_{ac})과 설계기준에서 제시하고 있는 요구보유성능(minimum required capacity, R_{code})에 의해 건물의 횡저항 시스템을 합리적으로 설계하는 방안을 제시하고자 한다. 제안 방법은 기존 구조 설계과정에 비선형 해석에 의한 횡저항 성능 평가가 추가된 것으로, 우선 기본 설계를 마친 후, 푸쉬오버(pushover)해석을 통해 구조물의 실제 횡저항 성능을 평가한다. 비선형 평가단계에서는 푸쉬오버(pushover) 해석을 수행하고 이선형화를 통해 항복밑면전단력(V_Y)을 결정한다. 그리고 설계풍밑면전단력(V_{wind})이 설계지진밑면전단력(V_D)보다 큰 경우 항복밑면전단력보다 설계풍밑면전단력이 작은 값임을 확인한 후에, 구조물이 보유한 R_{ac}를 산정한다. 설계지진밑면전단력이 큰 경우에는 바로 유효보유성능을 산정하고 이 유효 보유성능(R_{ac})이 요구보유성능(R_{code})에 근접하도록 피드백 과정을 통하여 부재를 재설계한다. 본 논문에서는 간단한 2차원 철골 가새가 설치된 철근콘크리트 구조를 이용하여 두 가지 경우에 대하여 제안한 합리적인 횡저항 시스템의 설계를 적용하였다. 그 결과 기본설계와 비선형 정적해석의 피드백 과정의 반복을 통하여 요구보유 성능에 근접한 유효보유성능을 갖는 횡저항 시스템을 설계하는 것이 가능하였다.적(最適) 온도(溫度)는 30^{\circ}C, avicelase와 {\beta}-glucosidase의 최적(最適) pH는 5.0, CMCase는 pH 5.5 이었으며, 균사(菌絲) 생육(生育)은 pH 5.0에서 양호(良好)하였다. 배양(培養) 기간(期間)은 avicelase가 8일(日), CMCase가 10일(日), {\beta}-glucosidase는 16 일간(日間) 배양(培養)하였을 때 최대치(最大値)를 보였고, 균사(菌絲) 생육(生育)은 12일(日) 배양(培養)했을 때 가장 양호(良好)하였다.가한 반면, 중국인들은 고소한 향의 강도, 고소한 향의 기호도, 전체적인 맛에서 뚜렷하게 일본참기름을 우수하게 평가하였다.s의 항체(抗體)로 반응(反應)시킨 후 protein-A gold(15 nm)로 표식(標識)시킨 바 제일 바깥 상층(上層)의 keratinocyte에 있어서 세포막표면(細胞膜表面)을 따라 표식(標識)되어 세포막항원(細胞膜抗元)을 나타내었으며, 이와 같은 소견(所見)으로 미루어 정상피부(正常皮膚) 중층편평상피세포(重層扁平上皮細胞)에서도 동일(同一)한 소견(所見)을 관찰(觀察)할 수 있다고 본다.al remnants, Resorption of fetus로 관찰된 것이다. Fetal death는 수정후 14{\sim}18일까지의 사망으로써 Maceration of fetus로 관찰되는 것이다. 통계학적 분석은 각 Group의 착상 을과 자궁 내 사망 율을 산출할 때에는 각 임신마우스에 따라 발생빈도가 크게 다르기 때문에 통계처리에는 Non parametric 검정인 Kluskal Wallis 검정을 사용하여 분석하였다. 또한 개체 Level 영향인 착상을, 태아사망, 기형의 threshold dose의 산정에 대해서는 SAS
After studying the composition about the torsional shafting of main engine for fishing vessel with Power Take Off (PTO) System, the authors made a computer program using the transfer stiffness coefficient method (TSCM) for analyzing torsional vibration about the shafting with PTO system and nonlinear elastic coupling. The torsional shafting of main engine was separated by 3 types according to the connecting. The torsional shafting of main engine was separated by 3 types according to the connecting condition of main engine with propeller or the PTO system or both of them. In this paper, the change of natural frequencies and natural modes according to connecting condition of torsional shafting and nonlinear elastic coupling were analyzed. The accuracy of the TSCM was confirmed by comparing with the computational results of the Finite Element Method.
건축구조물의 내진성능을 효율적으로 평가하기 위해서는 다자유도계 구조물을 등가 1자유도계로 표현하는 것이 필요하다. 본 연구는 다층 철근콘크리트 골조구조를 등가 1자유도계로 치환하는 방법을 제시하였다. 다층 철근콘크리트 모멘트 골조를 등가 1자유도계로 치환하여 모델화에 따른 비선형 시간이력해석을 통하여 다자유도계 구조물의 축약 방법의 타당성을 검토하는 것이 목적이다. 다층 골조구조의 정적 비선형 해석을 수행하여, 등가 1자유도계의 복원력 모델을 설정하였다. 다층 골조 구조의 비선형 시간이력해석 응답치와 등가 1자유도계의 시간이력해석 응답치를 비교하여, 등가 1자유도계 모델의 타당성을 검증하였다. 다층 철근콘크리트 골조구조를 등가 1자유도계로 치환하여 비선형 지진응답을 구하는 방법은 충분히 그 타당성이 있다는 것이 확인되었다. 다층 철근콘크리트 골조구조의 대표변위로서 1차모드참여 yector_1,\beta{_1\mu}= 1인 높이가 등가 1자유도계의 응답을 가장 근사하게 나타내는 것을 알 수 있었다. 등가 1자유도계의 지진응답해석에 사용하는 복원력 모델의 이력곡선에 따라 응답파형에 차이가 생기므로, 실제 frame 구조의 복원력 특성을 반영한 이력모델을 선정하는 것이 중요하다.