        21.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A single-stage electrostatic precipitator (ESP) was evaluated in terms of its performance in removing dust in subway tunnels. A wire-to-plate type ESP was tested in a small-scale wind tunnel. The effects of wire-to-wire spacing (2040 mm) and the material connecting wire-to-wire on the performance of ESP were investigated, with varying applied voltage and airflow velocity. A narrower wire-to-wire spacing showed higher collection efficiency at the same applied voltage. Lower electrical resistivity of material connecting wire to wire was more effective. Ozone generation in subway tunnel applications was insignificant.
        4,000원
        22.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to investigate the response characteristics and performance of a biofilter in the removal of ammonia, as a malodor compound. A trickle-bed type biofilter was applied for this study, and operated at the ammonia loading rate of 0.97-15.52 g/m3·h. The results of the experiment indicate that the critical loading rate of ammonia to the biofilter was 10.7 g/m3·h and the elimination capacity was 11.6 g/m3·h. The analysis of nitrogen mass balance in the reactor indicates that inlet nitrogen as gas phase was converted through the biofilter into NH4 + (41.5% by mass), NO2 - (43%), and NO3 - (15%) as the available form of nitrogen in the effluent liquid. Free ammonia concentration in the effluent liquid was estimated as being in the range from 0.14 to 2.93 mg/L (average 1.7 mg/L) during the experimental period.
        4,000원
        23.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main object of this study is to investigate the collection characteristics of an electro-static multi-staged impaction system, experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as the inlet velocity, stage number, applied voltage and shape of discharge electrode, etc. In results, the pressure drop is shown below 148 mmH2O lower than that of the conventional bag filter at inlet velocity 3.46 m/s and 5 stage. For 5 stage , the collection efficiencies are to be 97.4, 99.0% with the applied voltage 0 kV at the inlet velocity 2.07, 3.46 m/s, while 98.4, 99.9% with 40 kV of a sharp edge discharge electrode. Additionally, the present system is to be considered as an effective compact system for a removal of particulate pollutants from marine diesel engines due to much higher collection efficiency and appropriate pressure drop.
        4,000원
        24.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        25.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study has implemented an experiment in which hydrogen sulfide was removed by establishing a two-stage packed tower effector filled with nutritious medium and also filling a tower that was immobilized in ceramic media after isolating and identifying the sulfur oxidizing bacteria from a sewage treatment plant. As a result, strains isolated from the sewage treatment plant were found to be similar, including Bacillus fusiformis, Bacillus anthracis sp., Paenibacillus sp., Serratia marcescens sp., Bacillus thuringiensis. The effector that immobilized isolated strains in the ceramic media achieved an approximately 90% removal rate of hydrogen sulfide, while the sterilized ceramic media not immobilized with isolated strains showed a removal rate of about 65%. In addition, the removal rate of hydrogen sulfide in the primary media packing effector immobilized with sulfur oxidizing bacteria was about 92%, while the secondary effector filled with medium had a hydrogen sulfide removal rate near 100%. In addition, 90% efficiency of removal was shown in conditions of EBCT 60s in the experiment that investigated removal rate of hydrogen sulfide according to residence-time, while the efficiency was rapidly reduced up to 45% in conditions of EBCT 30s. On the other hand, when operating for an extended period time while increasing the concentration of injected hydrogen sulfide, the amount of sulfate was increased from 2 mg/L to 12.7 mg/L, and pH was rapidly reduced to 2.7.
        4,000원
        26.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The volume of fluid method is applied to study the effects of the gas channel wall contact angle on the removal characteristics of a water slug in a right angle PEMFC gas channel. While maintaining the same GDL surface contact angle, two different contact angle distributions on the control area in the corner region are compared via the water coverage ratio and water volume fraction. The water coverage ratios of the hydrophobic channel corner case mainly show smaller values than that of the hydrophilic case except around 27 ms. The water volume fraction of the hydrophobic corner case is supposed to drop down quickly around 27 ms due to the dynamic movement of the liquid water compared to the hydrophilic case. In overall, the hydrophobic corner case shows better water slug removal characteristics.
        4,000원
        27.
        2015.11 구독 인증기관 무료, 개인회원 유료
        The volume of fluid (VOF) method is applied to study the effects of the gas channel cross-section shape on the removal characteristics of a water slug in a trapezoidal PEMFC gas channel. Two different open angles 50 and 60 degrees are selected to investigate the effect of cross-section shape on the behavior of a liquid water slug. In comparison to the 50 degrees case, the water slug is removed slightly faster for the 60 degrees case.
        3,000원
        28.
        2015.11 구독 인증기관 무료, 개인회원 유료
        To study the effects of the gas channel wall contact angle on the behavior of a liquid water slug, numerical simulations are performed with the volume of fluid (VOF) method. Two different contact angle combinations on the side and top channel walls are selected. In comparison to the reference case, the water slug is removed faster when the hydrophobic contact angle is applied selectively in the corner section.
        3,000원
        29.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the porous ceramic filter was developed to be able to remove both dust and hazardous gas contained in fuel gas at high temperature. The porous ceramic filters were fabricated and used as a catalyst support. And the effects have been investigated such as the mean particle size, organic content and addition of foaming agent on the porosity, compressive strength and pressure drop of ceramic filters. With the increase of mean powder size and the organic content for the cordierite filter, the porosity was increased, but the compressive strength and pressure drop were decreased. From the results of the research, the optimum condition for the fabrication of ceramic filters could be acquired and they had the porosity of 58%, the compressive strength of 13.4 MPa and the pressure drop of 250 Pa. It was expected that this ceramic filter was able to be applied to the glass melting furnace, combustor, and dust/toxic gas removal filter.
        4,000원
        30.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and UV254 in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.
        4,000원
        31.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main object of this study is to investigate the collection characteristics of wet-type rotating porous disk system experimentally. The experiment is carried out to analyze the pressure drop and collection efficiency for the present system with the experimental parameters such as system inlet velocity, stage number, tube diameter, inlet concentration, etc. In results, for the present system, at 5 stage and υin=1.8 m/s, the pressure drop becomes significantly lower as 64 mmH2O in comparison with that of the conventional wet type scrubber (Venturi scrubber, over 250 mmH2O). The collection efficiencies increase with higher inlet velocity showing 92, 95.7, 98.4%, while SO2 removal efficiencies decrease with increment of inlet velocity as 80, 65, 50% at υin=1.08, 1.44, 1.8 m/s and tube diameter Dt=10 mm, respectively. The present system is to be considered as an effective compact system for a simultaneous removal of particle/gas phase pollutants from marine diesel engines.
        4,000원
        32.
        2014.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The main object of this study was to investigate the collection characteristics of wet-type cyclone with wall cavity. The experiment was executed to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, water spray type, inlet velocity etc. In results, for the present system of wet-type, the pressure drop represented 35 mmH2O, while in dry-type 33 mmH2O showing lower 6% at vin=21 m/s. In case of vin=21 m/s and water spray 200 mL/min, the collection efficiency of the present system became significantly higher as 96.8% comparing to that of the conventional wet-type scrubber. Additionally, for 200 mL/min, SO2 removal efficiencies decreased with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at vin=6, 9, 12 m/s, respectively.
        4,000원
        33.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Capacitive deionization(CDI) has many advantages over other desalination technologies due to its low energy consumption, less environmental pollution and relative low fouling potential. The objectives of this study are evaluate the performance of CDI which can be used for dissolved salts removal from sewage. To identify ion selectivity of nitrate and phosphate in multi-ionic solutions and adsorption/desorption performance related to applied potential, a series of laboratory scale experiments were conducted using a CDI unit cell with activated carbon electrodes. The CDI process was able to achieve more than 75 % TDS and NO3-, NH4+ removals, while phosphate removal was 60.8 % and is inversely related in initial TDS and H3- concentration. In continuous operation, increasing the inner cell pressure and reduction of TDS removal ability were investigated which are caused by inorganic scaling and biofouling. However a relative mild cleaning solution(5 % of citric acid for calcium scaling and 500 mg/L of NaOCl for organic fouling) restored the electrochemical adsorption capacity of the CDI unit to its initial level.
        4,000원
        34.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        0.4μm의 세공크기를 갖고 있는 평막이 침지된 연속회분식 반응기에서 유입 유기물 농도가 영양염류 제거에 미치는 영향을 조사하였다. 분리막의 여과성능과 영양염류 제거효과를 규명하기 위하여 유입 유기물의 농도를 200 mg/L (Run-1), 400 mg/L (Run-2) 및 800 mg/L (Run-3)로 연속적으로 변화시키면서 실험하였다. COD/N 및 COD/P의 비가 증가할수록 T-N 및 T-P의 제거율은 모두 증가하였다. Run-1, Run-2 및 Run-3에서 T-N의 평균 제거율은 각각 28.1, 32.6 및 90.4%이었으며, 투과수의 T-N 평균 농도는 각각 32.0, 30.0 및 4.3 mg/L 이었다. 또한 Run-1, Run-2 및 Run-3에서 T-P의 평균 제거율은 각각 13.6, 35.3 및 93.1%이었으며, 투과수의 T-P 평균 농도는 각각 3.11, 2.33 및 0.25 mg/L이었다.
        4,000원
        35.
        2008.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Characteristics of commercial antimicrobial filter media for bioaerosol removal were estimated. A chitoasn/ medium filter, a catechin/HEPA filter, a silver/HEPA filter, a copper/pre filter, a electret cabin filter and a non-electret cabin filter were used for estimation. Filtration efficiency and antimicrobial efficiency was tested using Escherichia coli and Staphylococcus epidermidis. The electret cabin filter and the chitosan/medium filter showed the highest filtration and antimicrobial efficiency, respectively.
        4,000원
        36.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        터널 내 축적된 다양한 오염원들은 간헐적으로 수행되는 세척과정 중에 폐수로 배출되게 되며, 서울 시내 3개 터널 지점에서 수행된 수질분석결과 SS, CODCr, T-N, NH3-N, NO3-N, Zn, Cu, Cr(+6). Mn, Mg, Phenol. CN-, E-Coli 등이 고농도 형태로 배출되는 것으로 나타났다. 한편, 이러한 오염수질의 배출농도 특성은 터널 세척 폐수의 채취 방법, 세척횟수, 세척수량, 터널내벽 특성, 통행량, 배수 특성 등에 따라 다양한 농도범위를 보여주는 것으로 나타났다. 한편, 수집된 터널 세척폐수를 단순 중력침전을 이용하여 저감실험을 수행한 결과, CODCr는 80%, T-N, T-P는 각각 30, 90% 제거됨을 확인하였고, 중력침전 분리를 통하여 제거되지 않은 잔여 오염물질에 대하여 GAC 소재를 통한 흡착실험(터널 세척폐수 1l에 대하여 GAC를 50g을 투입) 결과, CODCr, T-N, Zn, Cu, Mn, Phenol, CN 항목에서 80% 이상 제거됨을 확인하였다.
        4,000원
        37.
        2006.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        중수로 원전내 여러 계통으로 부터 발생된 폐수지내에는 핵종이 다량 함유되어 있으며, Class A 및 C 폐기물로 분류되는 폐수지의 적정 처리 기술 개발을 위한 기초연구를 수행하였다. IRN-150 혼상 이온교환수지를 이용하여 비방사성 이온과 양이온의 흡착 특성 및 탈차용액을 이용한 이온의 제거 특성을 고찰하였다. IRN-150 수지의 이온의 흡착능은 이론값에 근접한 11 mg-C/g-IRN-150을 나타내었고, 양이온의 흡착 친화도를 단일성분 및 복합성분 시스템을 이용하여 분석하였다. 여러 가지 탈착용액을 이용한 폐수지로부터 이온의 제거 특성을 평가한 결과, 핵종을 전량 효과적으로 제거하기 위해서는 보다도 용액이 유리한 것으로 나타났다.
        4,300원
        38.
        2006.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        최근 미국 ANL연구소가 개발한 다이포실 수지는 우라늄의 선택특성이 우수하나 수지의 형태가 분말형이므로 입상의 비드형으로 제조하기 위하여 다이포실 분말을 알기네이트상에 고정화하는 방법을 적용하였다. 생성된 비드의 우라늄에 대한 흡착특성을 측정한 결과, 소디움 알기네이트 자체도 우라늄 흡착특성을 최대 68%까지 나타낸 후 30% 수준으로 감소하였으며, 이는 흡착후 탈착하는 과정을 거쳐 평형에 이르는 것으로 사료된다. 또한 비드내 다이포실의 양이 증가할수록 우라늄의 흡착이 증가하며 최대 85 %정도의 흡착율을 나타내고 있다. 다이포실 수지만의 경우 반응초기에 급격한 흡착을 보이고 있으나 3일정도 이후에는 비드의 흡착율과 유사한 결과를 나타내고 있으며 비드내 함유된 순 다이포실량을 고려할 경우 알기네이트 자체의 흡착효과로 인해 비드의 흡착효율이 크게 상승되는 것으로 해석된다. 우라늄 농도의 영향은 농도의 증가에 따라 우라늄의 제거효율이 감소하였으며, 비드의 양을 2배로 증가시킨 결과 최대 90%이상의 제거효율을 얻었다. 결론적으로 다이포실 수지를 소디움 알기네이트상에 고정화하여 입자형의 비드로 제조하므로서 적은 양의 수지로 우라늄 제거특성이 우수한 비드를 얻을 수 있었으며 나아가서 연속공정에의 적용도 가능한 것으로 사료된다.
        4,000원
        39.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Bioaerosols are airborne particles of biological origins including viruses, bacteria, fungi, and all varieties of living materials. In suitable hosts, bioaerosols are capable of causing acute or chornic diseases that may be infectious, allergenic, or toxigenic. Bioaerosols from outdoor air accumulate on filters of heating, ventilating and air conditioning (HVAC) system in large quantities and are able to multiply there under certain conditions. In this study, silver was coated on activated carbon fiber (ACF) filters by an electroless plating method, and their efficacy for bioaerosols removal was tested. Physical filtration and biological antimicrobial test were performed. SEM and XRD analyses were used to characterize the morphology and components of ACF filters. Electroless silver-plated ACF filters showed antimicrobial efficiency, whereas pure ACF filters did not. It was found that electroless silver plating did not influence the physical filtration efficiency of ACF filters.
        4,000원
        40.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In recent models of semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as NH3, SOx and organic gases introduced from outdoor air into clean room. Meanwhile, there is a large quantity of exhaust air produced from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate heat recovery, particle collection, and gas removal in a heat recovery type air washer system for semiconductor manufacturing clean rooms.
        4,000원