검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 52

        1.
        2024.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study explored effects of a sludge-based biochar addition on nitrogen removal of membrane bioreactor (MBR) for wastewater treatment. The membrane fouling reduction by the biochar addition was also investigated. A dose of 3 g/L of the biochar was applied to an MBR (i.e., BC-MBR) and treatment efficiencies of organic matter and nutrient were analyzed. The MBRs with powdered activated carbon (i.e., AC-MBR) and without any additives were also operated in parallel. The average removals of COD and TN were improved with the biochar addition compared to those with the control MBR. Interestingly, operational duration was also increased with biochar addition. The CLSM analysis revealed that biomass amounts of BC-MBR and AC-MBR were reduced by more than 40%, and thickness of the biofilm attached to the membrane surface also was decreased. The physical properties of biochar surfaces were compared with a commercial powdered activated carbon. The specific surface area with 38 m2/g and pore volume with 0.13 cm3/g of the biochar were much smaller than those of the powdered activated carbon, which were 1100 m2/g and 0.67 cm3/g, respectively. Manufacturing conditions for the biochar production needs to be further investigated for enhancing physical properties for adsorption and biological improvement.
        4,500원
        2.
        2024.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The intensive development of the petrochemical industry globally reflects the necessity of an efficient approach for oily sludge and wastewater. Hence, for the first time, the current study utilized magnetic waxy diesel sludge (MWOPS) to synthesize activated carbon coated with TiO2 particles for the removal of total petroleum hydrocarbons (TPH) and COD from oily petroleum wastewater (OPW). The photocatalyst was characterized using CHNOS, elemental analysis was performed using X-ray fluorescence spectroscopy (XRF), field emission scanning electron microscope (FESEM), high-resolution transmission electron microscope (HR-TEM), X-ray diffraction analysis (XRD), Fourier transform infrared spectrometer (FTIR), Raman, energy dispersive X-ray spectroscopy (EDX), X-ray photoelectron spectroscopy (XPS), MAP thermo-gravimetric analysis/ differential thermo-gravimetric (TGA–DTG), Brunauer–Emmett–Teller (BET), diffuse reflectance spectroscopy (DRS), and vibrating sample magnetometer (VSM). The optimization of synthesized highly porous AC/Fe3O4/TiO2 photocatalyst was conducted considering the impacts of pH, temperature, photocatalyst dosage, and UVA6W exposure time. The results demonstrated the high capacity of the MWOPS with inherent magnetic potential and desired carbon content for the removal of 91% and 93% of TPH and COD, respectively. The optimum conditions for the OPW treatment were obtained at pH 6.5, photocatalyst dosage of 250 mg, temperature of 35 °C, and UVA6W exposure time of 67.5 min. Moreover, the isotherm/kinetic modeling illustrated simultaneous physisorption and chemisorption on heterogeneous and multilayer surfaces. Notably, the adsorption efficiency of the AC/Fe3O4/TiO2 decreased by 4% after five adsorption/desorption cycles. Accordingly, the application of a well-designed pioneering photocatalyst from the MWOPS provides a cost-effective approach for industry manufacturers for oily wastewater treatment.
        5,400원
        3.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There are two primary sludge drying methods such as the direct heating microwave method and the indirect heating steam one. In this study, the drying treatment facility at sewage treatment plant A applied both of these drying methods. The research aimed to investigate the optimal operation approach for the drying facility, considering the input sludge and the moisture content data after the drying process. Moisture content and removal rate data were executed at the research facility from January 2016 to December 2018. First, the microwave, a direct heating drying method, performed intensive drying only on the outer surface of the sludge by directly applying heat to the sludge using far infrared rays, so effective sludge drying was not achieved. On the other hand, the steam method of the indirect heating method used steam from a gas boiler to maximize the utilization of the heat transfer area and reduce energy of the dryer, resulting in an effective sludge drying efficiency. The sludge moisture content brought into the sludge drying facility was about 80%, but the moisture content of the sludge that went through the drying facility was less than 10% of the design standard. Therefore, the steam method of the indirect heating method is more effective than the microwave method of the previous direct heating method and is more effective for maintenance It has proven that it is an efficient method of operating construction facilities.
        4,000원
        4.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The object of this study is to feasibility assesment for co-digestion efficiency of food waste recycling wastewater(FWR) with thermal hydrolysis process dehydration cake (THP Sludge). As a result of THP pre-treatment experimental conditions to 160oC and 30 minutes, the solubility rate(conversion rate of TCOD to SCOD) of the THP sludge increased by 34%. And the bio-methane potential in the THP sludge increased by about 1.42 times from 0.230 to 0.328 m3 CH4/kg VS compared to the non-pre-treatment. The substrates of the co-digestion reactor were FWR and THP sludge at a 1:1 ratio. Whereas, only FWR was used as a substrate in the digestion reactor as a control group. The experimental conditions are 28.5 days of hydraulic retention time(HRT) and 3.5 kg VS/m3-day of organic loading rate(OLR). During the 120 days operation period, the co-digestion reactor was able to operate stably in terms of water quality and methane production, but the FWR digestion reactor deteriorated after 90 days, and methane production decreased to 0.233 m3 CH4/kg VS, which is 67% of normal condition. After 120 days of the experiment, organic loading rate(OLR) of co-digestion reactor was gradually increased to 4.5 kg VS/m3-day and operated for 80 days. Methane production during 80 days was evaluated to be good at the level of 0.349 m3 CH4/kg VS. As a result of evaluating the dehydration efficiency of the sludge before/after 150-180oC THP using a filter press, it was confirmed that the moisture content of the sludge treated before THP at 180oC was 75% and improved by 8% from 83-85% level. Therefore, it is expected that the co-digestion reactor of FWR and THP sludge will ensure stable treatment water quality and increase bio-methane production and reduction effect of dehydration sludge volume.
        4,500원
        5.
        2018.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 막결합생물반응조(MBR)공법을 비롯한 하수고도처리공법에서 유입하수량의 변화에 따른 슬러지 특성 변화를 파악하고자 하였다. 일 1.5톤을 처리하는 모형실험시설에서 설계유량 대비 유입하수량을 100, 70, 40, 10%로 변 화시켜가며 이에 따른 비탈질속도(specific denitrification rate)와 비질산화속도(specific ammonia oxidation rate)의 변화를 측 정하였다. 각 공법의 폭기조에서 채취한 슬러지의 비질산화속도는 유입하수량 100% 조건에서 세 가지 공법 모두 유사한 값 (0.10 gNH4/gMLVSS/day)으로 측정되었다. 유입하수량이 70%에서 40%로 감소함에 따라 비질산화속도가 크게 감소하는 경향을 나타냈다. 비탈질속도 역시 유입하수량이 감소함에 따라 최대 50%가량 감소하였다. 유입하수량이 감소할수록 비탈질속 도와 비질산화속도가 감소하는 경향을 나타냈으나 원수의 총질소 농도와 반응조 내 미생물 농도를 고려하면 질소제거율에 영향을 미칠 정도는 아니었다. 따라서 유입하수량이 감소하는 경우에도 반응조 내 미생물 농도를 높게 유지할 수 있다면 안정적인 질소 제거가 가능할 것으로 판단된다.
        4,000원
        6.
        2017.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        하⋅폐수 처리 기술은 종래 단순 오염물질 처리에서 에너지 및 자원 절약형의 고도처리 기술로 발전되고 있으며, 공공 수역으로의 오염 물질과 유독 물질 배출을 최소화하고 설치⋅운영의 효율성을 높이기 위해 IT 및 BT와 같은 다양한 기 술을 접목한 융합형 기술로 진화하고 있다. 국내 하⋅폐수 처리기술의 발전 추이를 살펴보기 위해 등록된 특허기술을 수집⋅ 조사하여 연도별⋅부문별로 분류하여 분석하였다. 본고에서 2010년~2017년 5월 간의 관련된 특허 등록 내용을 생물학적⋅ 물리화학적 처리공정, 장치 및 기기, 소재⋅제재, 슬러지처리, 분리막, 공정제어기술 등 10개 분야의 42개 세부 영역으로 나누 어 추세를 분석했다. 총 3,356건의 특허가 등록되었으며 2013년에 638건으로 최고치를 기록한 이후 다소 감소하여 연간 3~400여 건을 유지하고 있다. 등록된 특허 총 건수는 아직 다른 국가에 비해 적지는 않으나 공정 제어 및 기기 분야, 신개념 처리 기술과 같이 세계 시장을 선도할 수 있는 첨단 기술의 특허는 타 분야에 비해 미흡한 것으로 나타났다.
        4,600원
        7.
        2016.02 구독 인증기관 무료, 개인회원 유료
        정수슬러지를 탄화 및 활성처리하여 흡착제를 제조하였으며, 이를 이용한 황화수소 흡착특성을 고찰하였다. 제조 된 흡착제에 대한 BET측정 및 SEM 등 물성분석을 실시하였으며, 황화수소를 대상으로 회분식의 흡착평형실험 을 실시하였다. 실험변수로는 활성처리시 적용되는 약품종류 및 농도 등이 적용되었다. 실험결과, 정수슬러지는 탄화나 약품첨착과정을 통해 커다란 성능 향상이 이뤄짐을 알 수 있었다.
        4,000원
        8.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.
        4,000원
        9.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.
        4,500원
        10.
        2013.02 구독 인증기관 무료, 개인회원 유료
        Ocean discharge of sewage sludge, which started in the year of 1993 in Korea, was stopped in the beginning of 2012, Landfill of sewage sludge was also prohibited in 2003 owing to public acceptance of the lanfill sites, and partially reopened in 2007 due to the necessity of organic component in sludge to produce methane gas. Sludge recycle ratio will increase in sewage sludge treatment by volume reduction and drying, and then recycle of the thermal energy as fuel in power plant and also material as raw material of cement. Several drying processes are compared with reasoning and an appropriate drying sequence is suggested.
        4,000원
        11.
        2012.02 구독 인증기관 무료, 개인회원 유료
        H2S adsorption characteristics of adsorbent made by drinking water treatment sludge were investigated. For analyses of the manufactured adsorbent, various methods such as scanning electron microscope(SEM), measurements of BET surface area were adopted. As the major adsorption characteristic, breakthrough curve was measured by using a continuous fixed bed adsorption column for operating variables such as aspect ratio(L/D, 3∼9), gas flow rate(0.2∼1.0 liter/min) and type of samples. The experimental results showed that the breakthrough pint decreased with increasing gas flow rate, but increased with increasing aspect ratio. It was also found that the physical and chemical treatments of drinking water treatment sludge are very important for the improvement in H2S adsorption capacity due to property changes of the sludge.
        4,000원
        12.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        수수(Sorghum bicolor(L.) Moench) 잡종의 미량(微量) 광물질(鑛物質) 함량에 미치는 정수장(淨水場) 슬러지의 영향에 관해 조사를 했는데, 이번 보고는 니켈 성분의 분석에 관한 것이다. 대조구(對照區), 부숙(腐熟)시킨 정수장 슬러지, 정수장 슬러지+질소-인산-칼륨 비료, 부숙시킨 슬러지+질소, 인산, 칼륨 비료의 4가지를 처리로 하였고, 1, 3, 5시간 예열(豫熱) 시간이 실험 조건이었다. 5시간 이후의 조건에서 백그라운드의 값이
        4,000원
        13.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A wastewater treatment plant consists of unit processes designed to achieve specific waste reduction goals. However, offensive odors associated with the treatment processes are a constant source of public complaints. The purpose of this study was to statistically determine the process parameters that influence the formation of volatile sulfur conpounds (VSCs) in the secondary treatment system. A statistical model was developed to relate the process parameters to the formation of VSCs in this system. The model established that F{M ratio, sludge blanket depth and SSV60 were the dominant process parameters that would influence the formation of VSCs in the secondary sedimentation basin. This model provides a useful tool for plant engineers to predict and control the VSCs formation in an secondary activated sludge system.
        4,000원
        14.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        정수장 슬러지는 수 처리 역 세척 과정에서 발생되는데, 기계적인 방법 또는 자연건조방법으로 탈수된 후 주로 해양투기, 매립등의 방법으로 처리한다. 최근에는 런던협약에 의해 해양투기가 상당히 제약을 받고 있다. 탈수된 정수장 슬러지를 위생매립장의 복토재로서의 활용가능성을 파악하기 위하여 실내실험을 통하여 정수장슬러지의 물리 화학적 특성과 지반공학적 특성을 파악하였다. 슬러지의 지반공학적 특성을 향상시키기 위하여 슬러지에 일반토사를 혼합한 시료에 비중계실험, 액 소성한계실험 비중실험, 다짐실험. 일축압측 실험등을 실시하였다. 슬러지에 일반토사를 혼합한 혼합토는 정수장슬러지와 비교하여 최대건조단위증량은 증가하고, 최적함수비는 감소하였고, 최대압축응력과 마찰각을 증가한 반면 점착력은 감소하였다. 미국환경청의 복토재 기준을 확보하기 위해서 슬러지와 일반토사를 3:7로 혼합하여야 하며, 혼합토의 압축강도는 3.6kg/cm2이다.
        4,000원
        15.
        2006.02 구독 인증기관 무료, 개인회원 유료
        The characteristics of fluidized bed catalytic combustion for sludge treatment have been studied in a pilot scale of fluidized bed combustor. 1.0wt% Pt of catalyst supported on the spherical alumina was mixed with the spherical pure alumina as a bed material. Sewage sludge, heating value of which is 3,440 kcal/kg, was used as a waste sample in the experiment. Through the experiments, the various characteristics such as a bed temperature profile and flue gas(CO, SO2) concentration profile were investigated and the catalyst mixing ratio and sample feed rate were applied as experimental parameters. The experimental results showed that bed temperature was maintained more highly and flue gas concentration decreased with the increase of the catalyst mixing ratio, and bed temperature was maintained more highly also and flue gas concentration increased with the increase of the sample feed rate. The combustion efficiency of fluidized bed catalytic combustion of the sludge increased with the increase of the catalyst mixing ratio and sample feed rate and reached more than 96%.
        4,600원
        16.
        2005.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In general, water treatment sludge (WTS) had high concentration of heavy metal, thus it made the reuse or recycling of WTS difficult. The optimal solidification conditions for maximum suppression of heavy metal elution from WTS were decided in this study. Under the optimal solidification conditions (i.e., temperature, 320℃; ratio of WTS and MgO, 9:1; solidification time, 1hr), all of heavy metal including aluminum were not detected. Therefore there are no problems for reuse or recycling of WTS which was solidified under the optimal solidification conditions found in the study.
        4,000원
        18.
        2000.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        All crude oil carries a little of water, sand, and mineral sediment molecules tightly bounded with hydrocarbons. The result is the gradual precipitation of these heavier elements into thick, granular petroleum by products known as crude oil sludge. The oily sludges in ship tanks and in storage facilities have to be treated efficiently in order to keep the security and the capacity of storage facilities, to protect a serious environmental pollution, and to retrieve lost resource. The oily sludge treatment system should be designed to satisfy requirements mentioned in safe work condition. As a basic study, in this paper, an oily sludge treatment system by ultrasonic waves was proposed. Then, the features of ultrasonic energy and recovery of sludge with ultrasonic waves are investigated by experiments. As results, we found that ultrasonic waves are a new energy to flow oil sludge environment-friendly in safe work condition. In addition, it was shown that ultrasonic energy is more efficient than thermal energy in treating oil sludge, and that the volume of wastes for disposal is reduced remarkably.
        4,200원
        19.
        1999.12 구독 인증기관 무료, 개인회원 유료
        하수슬러지의 퇴비화를 촉진할 수 있는 방안을 검토하기 위하여 2월 및 8월에 하수슬러지를 채취하여 생균수를 측정한 결과 하수종말처리장에서의 폐수처리시 유입수량 변동, 양이온성 polyacrylamide의 사용량 및 기후 변동을 포함하는 여러 조건의 변화에 따라 미생물 종과 미생물수의 변동이 많았으며, 미소후생동물의 종류 및 활동성도 계절에 따른 차이가 있었다. 양이온성 polyacrylamide가 미생물 생육에 미치는 영향을 조사한 결과 양이온성 polyacrylamide의 농도가 0.8% 이상일 때는 모든 균주의 생육이 저해되었으나 0.2% 이하에서는 균 생육에 지장을 초래하지 않았다. 하수슬러지의 퇴비화 과정중에 관여하는 미생물의 균종과 균수를 조사하고자 하였으나 미생물의 생태적 생리적 특성과 퇴비화의 일정한 상관관계를 도출할 수는 없었다. 그러나 유기물 함량과 bulking agent로 톱밥을 투여하였을 경우 미생물의 균종과 균수의 증가가 관찰되었다. 하수종말처리장의 폭기조 투입직전 활성슬러지, 폭기조내 활성슬러지, 하수슬러지와 bulking agent로 톱밥을 혼합처리하여 관찰한 결과 Fragilaria sp., Proales sp., Vorticella sp., Schizothrix sp., Anabaena sp., Zoothaminium sp., Epstylis sp., Arcella sp., Balantidium sp., Actinophrys sp., Synedra sp., Euglypha sp., Ulothrix sp., Anacystis sp., 및 Clostium sp. 등의 다양한 미소 후생동물이 관찰되었다. 특히 전기간에 걸쳐 Fragilaria sp., Proales sp., Vorticella sp. 몇 Schizothrix sp.가 관찰되었다. 슬러지 내에 존재하는 세균, 효모, 방선균, 곰팡이, 미세조류, 원생동물 및 하등동물은 하수슬러지의 퇴비화 또는 감량화 과정 중에 존재하여 공극의 확보와 같은 물리적인 퇴비화 촉진과 생물학적 분해작용에 의한 퇴비화 촉진 효과를 얻을 수 있을 것이다.
        4,000원
        20.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to recover the aluminum from water treatment plant sludge containing alumina. The optimum reaction conditions about chlorination of sludge with NH4Cl are as follows: the weight ratio of sludge to NH4Cl is 4, the reaction time is 60min, and the temperature is 300℃. And the result of leaching time test showed that the highest yield of alumina at 160℃ was 96% but the result of leaching test at 160℃ was little better than that of leaching test at 100℃ while the leaching concentration of HCl was 4N. The optimum reaction conditions of chlorinated sludge with NH4Cl, gave the highest yield of 95.41% based on aluminum.
        4,000원
        1 2 3