검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 98

        1.
        2024.03 KCI 등재 구독 인증기관·개인회원 무료
        시설 고추 주요 해충인 꽃노랑총채벌레(Frankliniella occidentalis)의 방제를 위해 유기농업자재들의 단독 처리 및 종합 투입시 방제 효과를 검정 하였다. 황색끈끈이롤트랩은 지제부에 설치하고, 포식성 천적(Hypoaspis miles)은 지제부에 접종하며, 식물추출물(커스터드애플시드 오일 50% + 계 피 추출물 10%)은 경엽살포하는 방식으로써 각각의 단독 처리시 방제 효과는 45.3, 36.6, 50.2%였다. 한편, 3종의 유기농업자재들을 종합 투입했을 경우 고추 수확기 방제 효과가 무처리 대비 62.4~80.9%로 유지되어, 시설 고추 꽃노랑총채벌레 친환경 방제용으로 활용이 가능할 것으로 생각된다.
        2.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In 2006, Cambodian Agriculture Research and Development Institute (CARDI) bred a high-quality tomato ‘Neang Pich’ variety. Since ‘Neang Pich’ is susceptible to Sclerotium rolfsii (S. rolfsii), it is severely affected the production major tomato growing regions. This study was conducted to evaluate the effect of seven S. rolfsii tolerant rootstocks on growth and yield in graft cultivation of ‘Neang Pich’ tomato. ‘Neang Pich’ seedlings were used as scion and non-grafted control. Six eggplant genotypes (‘2017053’, ‘2017062’, ‘17CJVC2’, ‘No. 80’, ‘VI041979A’, ‘VI041996’) and a commercial tomato variety (‘Hulk’) were used as rootstock. The grafted and non-grafted tomatoes were grown in a plastic greenhouse and open field. The survival rate of plants did not differ between plastic greenhouse (80.2%) and open field (79.5%). The top and root fresh weight of plants grown in a plastic greenhouse increased by 77% and 11% compared to the open field and the dry weight increased by 48% and 10%, respectively. The top (309 g) and root (18.9 g) fresh weight, and the top (90.5 g) and root (6.39 g) dry weight depending on rootstock were the highest in plants grafted onto ‘2017062’. The yield of tomatoes in a plastic greenhouse (19.5 MT/ha) was 65% higher than that of open field (11.8 MT/ha). The yield of tomatoes depending on rootstock were the highest in ‘2017062’ (17.8 MT/ha). The effect of cultivation practice and grafting on pH and sugar content (oBrix) of the fruit was non-significant difference (p0.05). The scion diameter, top fresh weight, fruit weight and yield (MT/ha) were significant difference (p0.05) in the interaction effect between tomato cultivation practices (plastic greenhouse and open field) and rootstock.
        4,000원
        3.
        2023.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        총채벌레는 우리나라에 60여 종이 알려져 있으며 다양한 시설작물에서 직접적인 섭식 피해 이외에 토마토반점위조바이러스(TSWV)를 매 개하는 간접적인 피해도 유발한다. 그동안 총채벌레 방제는 살충제에 의존해 왔는데, 이는 농업환경에 많은 부작용을 유발하고 해충의 저항성을 유발시켜 더욱 방제를 어렵게 하고 있다. 이러한 문제를 해결할 수 있는 대안으로 내성 회피를 위한 물질을 탐색하였다. 실내검정으로 약용작물 67종의 추출물을 꽃노랑총채벌레 성충에 처리하여 가장 효과가 우수한 목단피를 선발하였다. 목단피 추출물을 처리 후 1일차에 100%의 살충효 과를 보였다. 또한, 목화진딧물은 3일차 83%, 복숭아혹진딧물 3일차 97%, 점박이응애 1일차 100%의 살충효과를 보였다. 고추 포트 검정에서 꽃노랑총채벌레 방제가는 1일차 77.6%, 2일차 40%의 효과가 나타났다. 현재 추가적으로 효과를 증대시킬 수 있는 물질을 탐색하고 있으며, 총 채벌레 방제에 본 추출물을 활용한다면 효과적일 것으로 기대된다.
        4,000원
        4.
        2023.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        하절기의 높은 일사량은 작물의 과도한 호흡을 유발하여 광 합성을 감소시킨다. 또한 주로 하절기에 발생하는 장마는 온실 내부에 저일조 환경을 유발한다. 저일조 환경은 작물의 생 육과 생산량을 감소시키는 원인이 될 수 있다. 본 연구는 하절 기 차광과 보광이 오이의 생육과 생산량에 미치는 영향에 대 해서 조사하기 위해 수행되었다. 오이 접목묘는 2022년 8월 30일에 플라스틱 온실 2동에 정식하였다. 온실 내부의 광량을 감소시키기 위해 온실 1동에 차광 스크린을 설치하였다. 보광 처리는 2022년 9월 7일부터 2022년 10월 20일까지 수행되 었다. 고압나트륨등(high-pressure sodium lamp), 백색 LED (white LED, red:green:blue = 5:3:2), RB LED(combined red and blue LED, red:blue = 7:3)를 보광 광원으로 사용하였 고, 무처리를 대조구로 설정하였다. 보광 처리는 일출 전과 일 몰 후 2시간씩 수행하였고, 보광 광도는 150±20 μmol·m-2·s-1 로 설정하였다. 식물 초장, 엽장, 엽폭, SPAD는 차광 처리에 의해 증가하는 경향을 보였다. RB LED에서는 차광 처리와 관계없이 경경이 유의성 있게 증가되었다. 과실의 생체중과 건물중은 차광과 보광 처리에서 유의미한 차이가 없었다. 과실의 평균 과중은 수확일이 지날수록 보광처리 간의 유의한 차이는 없었다. 결론적으로, 본 연구에서 하절기 오이 재배 시 50% 수준의 차광 처리는 오이의 생육을 유의하게 향상시켰 다. 또한, 보광 대조구에서 생육과 과실 특성이 좋았다. 본 연 구는 오이 재배 시 보광 기술을 적용하기 위한 기초 연구 자료 로 활용될 수 있다.
        4,000원
        8.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        시설 재배지에 음식물류폐기물 혼합 가축분 퇴비 사용이 늘어나고 있다. 이에 본 연구는 음식물류폐기물 혼합 가축분 퇴비(Food Waste Compost with manure, FWC) 연용 시 시설 토마토(Solanum lycopersicum L.)의 생육과 수량에 미치는 영향을 구명하기 위해 3년간 수행하였다. 퇴비 처리는 사용량에 따른 효과를 알아보기 위하여 농촌진흥청 시설 토마토 표준 시비량(N-P2O5-K2O=20.4-10.3-12.2 kg 10a-1)의 총 질소량 기준 100%로 하여 무기질 비료 반량 + FWC 정량(NPKFWC1), 무기질 비료 반량 + FWC 2배량(NPKFWC2), 무기질 비료 반량 + FWC 3배량 (NPKFWC3)을 처리하였다. 또한, 무기질 비료 사용량에 따른 변화를 퇴비와 비교하기 위해 무기질 비료 반량(NPK 50%) 및 무기질 비료 정량 (NPK 100%, Control) 처리하였다. 초장은 FWC 처리구가 대조구 대비 높았으며, SPAD-502 값은 NPKFWC2에서는 증가하였으나, NPKFWC3는 대조구 대비 낮아지는 경향을 보였다. 3년차 수확 후 토양 pH의 경우 NPKFWC3에서 6.5로 가장 높은 수치를 보였으며, 토양 EC는 NPKFWC1에서 9.5 dS m-1로 가장 높았고, NPKFWC3 처리구에서 6.9 dS m-1 가장 낮은 값을 보였다. 3년간 전체 처리구 간 과실의 평균 횡경, 종경, 당도는 차이가 없었다. 수량은 NPKFWC2까지는 높았으나, NPKFWC3에서는 오히려 대조구보다 낮아지는 경향을 보였다. 따라서 무기질 비료 반량에 음식물류폐기물 혼합 가축분 퇴비 처리 시 추천 시비량 대비 2배량까지는 생육 및 수량이 증가하나 3배량에서는 오히려 감소하는 것으로 판단된다.
        4,000원
        11.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 권취식 측창을 갖는 아치형 단동 플라스틱 온실 내 강제환기장치 설치 및 운용, 환기 성능 개선방안 등을 제안 하기 위해 온실 내부에 유동팬과 배기팬을 설치하여 강제환기 장치 사용에 따른 온실 내부기온 강하 특성을 정량적으로 조 사하였다. 시험은 3가지 환기 조건(측창, 측창+순환팬, 측창+ 순환팬+배기팬)에서 수행되었다. 각 조건 데이터로거를 이용 하여 환기 시작과 동시에 온실 내외부 기온 및 외부환경 변화 를 측정·기록하였고, 환기 방식별 기온차 변화의 평균값으로 부터 정규기온차를 계산하여 기온 강하 효과를 비교하였다. 오전(11:00-12:00)에는 환기 방식에 상관없이 환기 초반 정 규기온차가 일시적으로 증가했다가 감소하는 것으로 나타났 다. 강제환기장치가 더 많이 사용될수록 최대 정규기온차는 1.158에서 1.037로 감소하였고 최대 정규기온차에 도달하는 시간도 340초에서 110초로 단축되었다. 강제환기장치의 사 용은 정규기온차가 0.8까지 감소하는데 소요된 시간을 1,030 초에서 550초로, 0.6까지는 1,610초에서 915초로, 0.4까지는 2,315초에서 1,360초로, 자연환기의 약 60% 수준으로 감소 시켰다. 오후(14:00-15:00)에는 정규기온차의 증가가 관측되지 않았지만, 환기 시작과 동시에 기온차가 감소하기 시작 했다. 또한 강제환기장치가 더 많이 사용될수록 정규기온차 가 0.8까지 내려가는 시간을 560초에서 345초로, 0.6까지는 825초에서 540초로, 0.4까지는 560초에서 345초로, 약 70% 수준으로 감소시켰다. 따라서, 보다 효과적이고 경제적인 환 기를 위해 강제환기장치는 오전과 같이 열부하가 높은 환경에 서 적극적으로 사용하는 것이 바람직하다고 판단된다.
        4,000원
        12.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was carried out to investigate the effect of side vent heights on temperature and relative humidity inside and outside the single-span plastic greenhouse (W: 7 m, L: 40 m H: 3.9 m) during natural ventilation. Four different heights (120, 100, 80, 60 cm) of the side vent were used as an experimental condition. Variations of temperature and relative humidity inside and outside the greenhouse and the differences between heights were compared by using one-way ANOVA. In the daytime, the difference in temperature between inside and outside the greenhouse was dropped from 14.0°C to 7.1°C as the side vent height increased. The temperature difference in the nighttime was less than 0.2°C regardless of the height. One-way ANOVA on the temperature difference between heights presented that the statistical significance was founded between all of the combinations of height in the daytime. The difference in relative humidity between inside and outside the greenhouse was grown from –13.8% to – 22.2% with a decrease in the side vent height. The humidity difference in the nighttime was less than 1% regardless of the height. One-way ANOVA on the humidity difference revealed that most of the side vent heights showed significance in the daytime but between 100 and 80 cm was not significant. It seemed because the external air became cooler during the experiment with a height of 80 cm. Conclusively, this study empirically demonstrated that the higher side vents resulted in the decrease of differences in temperature and relative humidity between inside and outside the greenhouse, and also the effect of side vent height was statistically significant. This study may be helpful for deciding the height of the side vent effective for controlling temperature and relative humidity in a single-span greenhouse during natural ventilation.
        4,000원
        14.
        2022.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Pest control treatment was carried out using an unmanned automatic pesticide spraying system that can spray pesticides on crops while moving autonomously to control pests in vegetable greenhouse. As a result of examining the control effect on tomato and strawberry on thrips (Frankliniella occidentalis) and greenhouse whitefly (Trialeurodes vaporariorum) pests, 85.6% of yellow flower thrips were found in tomatoes and 87.5% in strawberries, and 81.7% (tomato) and 80.6% (strawberry) of greenhouse whitefly. In addition, the control effect according to the pesticide treatment method showed a control effect of 81.7% of the chemical spraying treatment by manpower and 83.9% of the automatic moving pesticide spraying treatment (F=22.1, p < 0.001). When comparing the control effect between the two treatment sections, there was no significance, but the automatic transfer spraying treatment showed a 2.2% higher effect. On the other hand, as a result of comparing the spraying time of the drug, the automatic unmanned control sprayer had a spraying time of 5 min/10a, which took about 25 min less than the conventional manpower spraying time of 25-30 min/10a. Based on these results, it was judged that the automatic transfer spraying method could be usefully used for efficient pest control in the facility greenhouse during the peak period of development.
        4,000원
        15.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 중학생들이 온실 효과와 지구 온난화를 이해하고, 이를 지구 복사 평형 관점에서 설명할 수 있는지 심층적으로 살펴보고자 하였다. 이를 위해 ‘대기권과 날씨’ 대단원 수업을 완료한 중학교 3학년 118명의 학생을 대상으로, 복사 평형, 온실 효과, 지구 온난화에 대한 선택형 및 서답형으로 구성된 학생 이해 온라인 평가를 2021년 7월 13 일부터 7월 24일까지 실시하였다. 최종적으로 97명의 학생 응답을 수집하여 분석한 결과, 과반수(61.9%)가 넘는 학생들이 복사 평형의 의미를 옳게 기술하였으나 제시된 자료와 무관하게 사전 지식이나 구체적 사례를 들어 설명하는 경우가 많았다. 대부분의 학생들(92.8%)은 대기가 있는 지구에서 온실 효과가 나타나는 것을 알고 있었지만, 온실 효과를 복사 평형이 깨진 상태로 생각하는 경향이 높았으며(32.0%), 달과 지구 모두 복사 평형이 일어난다고 응답한 학생 (47.4%)은 절반에 미치지 못했다. 온실 효과의 원인으로 대기의 재복사를 찾아낸 학생은 다수(69.1%)였으나, 지구로 입사한 태양 복사량보다 방출한 지표 복사량이 더 크다고 응답한 학생은 소수(39.2%)에 불과하였다. 또한 절반 정도의 학생들(49.5%)이 온실 기체의 증가와 대기 흡수, 이로 인한 지표로의 재복사의 관계를 잘 이해하고 있었다. 그러나 온실 기체가 증가할 때, 지표 방출에 대해서는 증가(14.4%), 일정(9.3%), 감소(7.2%), 무응답(18.6%)으로 의견이 매우 다양하게 나타났다. 복사 평형, 온실 효과, 지구 온난화는 지구계의 균형과 상호작용이라는 빅 아이디어로 연결된 커다란 하나의 의미망이므로 학생들이 지구 온난화로 인한 기후 변화를 이해하고 적용하고 해석하는 개념 체계가 될 수 있다. 따라서 현재 인류에 닥친 기후 변화 위기와 관련해 학생들이 정확한 이해에 근거하여 과학적으로 사고하고 과학적 개념을 정립할 수 있도록, 정교한 프로그램 개발과 수업 경험을 제공하고 그 효과를 점검하는 후속 연구가 진행되어야 할 것이다.
        5,400원
        16.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 원예특작시설 내재해형 규격서에 등록되어 있는 폭이 넓은 단동온실(10-단동-5형)을 대상으로 기초의 경계조건과 서까래 강관의 이음 유무에 대해 실물 크기 실험을 실시하고 그 결과를 수치해석 결과와 비교하여 이음부가 있을 때 구조성능 차이에 대해 알아보았다. 각 측정 위치별 변위를 실험에서 측정한 값과 수치해석으로 예측한 값을 비교한 결과에서는 기초의 조건 및 서까래 강관 이음 유무에 상관없이 모두 상당한 차이를 보였고, 힌지 조건 보다 고정 조건이 상대적으로 차이가 컸다. 그리고 모든 절점을 강접합으로 가정하고 구조해석한 결과를 구조실험과 비교한 결과에서는 힌지조건이 고정조건 보다 잘 일치하였지만 해석값이 실험값 보다 크게 나타났다. 수치해석은 모든 절점을 강접합으로 가정했기 때문에 실제 성능과 달랐다. 따라서 현재 모든 절점을 강접합 으로 가정하고 온실을 설계를 하면 과소설계될 우려가 있어 앞으로 신뢰성 높은 온실 설계를 위해서는 서까래와 도리가 교차하는 교차부 성능 특성을 고려한 구조해석 기술 개발이 이루어져야 할 것으로 판단된다.
        4,000원
        17.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 냉방이 가능한 반밀폐형온실과 일반 플라스틱온 실에서의 정식 후 고온 스트레스가 파프리카에 미치는 영향 구명을 위해 수행하였다. 지열과 팬앤패드를 활용하여 냉방이 가능한 반밀폐형온실의 파프리카는 냉방이 되지 않는 3중 플라스틱 하우스의 파프리카보다 유의적으로 높은 광합성 속도를 보여 주었다. 플라스틱 하우스의 파프리카가 고온 스트레스에 의해 광합성 속도가 느려지는 것을 제시하고 있다. 초장은 반밀폐형온실이 13cm 더 높게 증가하였으며, 엽면적은 이식 후 2주차까지 생장 속도가 비슷하였으나 3주차 경과 시 반밀폐형온실이 플라스틱온실보다 47% 높은 차이를 보였다. 착과 수는 반밀폐형 온실 10.6개/주, 플라스틱온실 4.6개/주가 착과하여 플라스틱 온실 대비 반밀폐형온실이 130% 높게 착과하였다. 과중 또한 반밀폐형온실과 플라스틱온실이 각각 566.7g/plant와 387g/plant으로 46% 차이를 나타냈다. 이상의 결과로 냉방이 가능한 반밀폐형온실에서 파프리카를 재배할 경우 일반 플라스틱온실보다 광합성과 생육이 양호하였음을 확인할 수 있었다. 따라서, 반밀폐형온실의 냉방 효율을 위한 요소기술을 일반 플리스틱온실에 적용하여 여름철 고온기를 극복한다면 수확량 및 품질 향상을 통한 농가소득 증대가 가능해질 것으로 기대된다.
        4,000원
        18.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하절기 토마토 재배 시 주간 포그 냉방, 야간 히트펌프 냉방을 처리를 하여 냉방 처리가 온실 내 온습도, 작물의 생육 및 수확량에 미치는 영향을 분석하였다. 하절기 주간에 차광 처리한 대조구 온실의 평균 온습도는 32.1°C, 59.4%였고, 포그 처리한 시험구 온실의 평균 온도는 30.0°C, 74.3%로 나타났다. 이 때 외부의 평균 온습도는 31.4°C, 57.7%로 대조구 온실의 온도는 외기보다 0.7°C 높았으나 시험구 온실의 온도는 외기보다 1.4°C, 대조구보다 2.1°C 낮게 나타났다. 평균 습도는 시험구 온실 74.3%, 대조구 온실 59.4%로 포그 처리를 한 시험구에서 높게 나타났다. 야간 대조구 온실의 평균 온습도는 25.2°C, 85.1%였고, 히트펌프로 냉방을 한 시험구 온실의 평균 온습도는 23.4°C, 82.4%, 로 나타났다. 야간 외부의 평균 온습도는 24.4°C, 88.2%로 대조구 온실의 온도는 외기보다 0.8°C 높았으나 시험구 온실의 온도는 외기보다 1.0°C, 대조구보다 1.8°C 낮게 나타났다. 평균 습도는 시험구 온실 82.4%, 대조구 온실 85.1%로 나타나 시험구 온실의 습도가 더 낮게 나타났다. 작물 생육은 정식하고 8주 후에는 두 온실 간의 큰 차이는 없는 것으로 나타났으나 냉방 처리 후에는 시험구 온실의 작물이 대조구에 비해 경경, 초장, SPAD 값이 높게 나타났다. 토마토의 수확량은 냉방을 시작하고 2주 후까지 총 생산량의 차이는 1.2%로 큰 차이 없었으나 3주 후와 4주 후의 일 생산량이 시험구에서 대조구보다 많게 나타났다. 최종적으로는 시험구의 수확량이 81.3kg, 대조구의 수확량이 73.8kg으로 시험구가 대조구에 비해 10.2% 많게 나타남으로써 하절기 주간 포그 냉방, 야간 히트펌프 냉방이 작물 성장에 적합한 환경을 조성해 줌으로써 생육 및 생산성에 영향을 미친 것으로 판단된다. 냉방 처리에 따른 경제성을 비교해보면 대조구 온실에서는 142,166원의 수익이 있었던 반면 시험구 온실에서는 28,727원의 손해가 발생하여 냉방 처리는 경제성이 떨어지는 것으로 나타났다. 그러나 재식 밀도, 히트펌프 운용 시간 및 기간을 조절하여 에너지 사용은 줄이면서 생산성을 증가시킨다면 경제성도 확보할 수 있을 것으로 기대되며 이에 대한 추가 연구가 필요할 것으로 판단 된다.
        4,000원
        19.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 ‘설향’ 딸기의 관부를 부분 난방하고 양액을 온수로 공급하면서 관행 재배 방식에 비해 온실 공간 온도를 낮게 관리하는 딸기 부분 난방 시험을 수행하였다. 정식 후 11월까지는 특별한 처리가 없어 대조구, 시험구 모두 온실 내 환 경이 유사하게 관리되었으며 관부 난방 및 온수 양액을 공급 하기 시작한 12월부터는 야간의 온실 온도, 관부 온도 및 베드 온도가 차이를 보였다. 12월의 온실 야간 평균 온습도는 대조구 7.1℃, 87.2%, 시험구 5.7℃, 88.7%로 시험구의 온도가 낮았으나 관부 난방을 수행함으로써 시험구 온실의 관부 및 베드의 온도를 9.3℃, 12.7℃로 유지하였고, 대조구 온실의 관부 및 베드 온도 7.9℃, 10.8℃보다 높게 관리할 수 있었다. 시험기간 내에서 시험구 온실의 딸기 관부 및 베드 온도는 대조구에 비해 모두 약 2.0℃ 가량 높게 유지되는 것으로 나타났다. 주간에는 온수 양액을 공급함으로써 지하수를 이용했을 때보 다 평균 8.7℃ 높은 온도 양액을 공급할 수 있었고 이로 인해 베드 온도도 약 5.0℃ 가량 높게 나타났다. 시험구에서는 시험 기간 동안 온실 난방, 관부 난방 및 온수 양액 공급에 총 9,475.7×10 3 kcal의 에너지를 소비하였고 대조구에서는 온실 공간 난방에 총 16,847×10 3 kcal의 에너지를 소비하여 시험구에서 대조구 대비 약 43.8%의 에너지 절감 효과를 확인할 수 있었다. 시험구에서 딸기 관부의 온도를 높게 관리함으로써 작물의 생육을 촉진시킬 수 있었고 그로 인해 정식 후 초세가 대조구에 비해 좋지 않았던 시험구의 딸기가 25주 후에는 대조구와 생육적인 면에서 큰 차이가 없는 것으로 나타났다. 딸기의 수확량은 초세가 좋았던 대조구에서 1화방의 수확량이 시험구에 비해 많았으나 2화방, 3화방에서는 관부의 온도를 높게 관리한 시험구의 수확량이 더 많았다. 3월 말까지의 주당 수확량은 시험구 412.7g/plant, 대조구 393.3g/plant로 유의미한 차이는 없었으나 시험구가 대조구에 비해 4.9% 많이 나온 것으로 보아 딸기의 온도 민감부인 관부의 온도를 높게 관리하는 것이 딸기 생육과 생산성에 영향을 미치는 것으로 판단된다.
        4,000원
        20.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A heat pump system using wasted heat from thermal effluent to supply the heating energy can reduce energy consumption and emissions of greenhouse gases by greenhouse facilities nearby. The Jeju National University consortium constructed a heat pump system using the thermal effluent from the Jeju thermal power plant of KOMIPO to provide with cool or hot water to greenhouse facilities located 2.5km from the power station. In this paper, the system configuration of the heat pump system was summarized, and the results of operations for demonstration of a heating performance carried out during the winter season in 2018 were investigated. Therefore, if the heating control by supplying thermal effluent to the facility greenhouse, it can contribute to reducing the energy cost and improving quality.
        4,000원
        1 2 3 4 5