In this paper, the hybrid prefabricated retrofit method that improve structural performance and reduce construction period was developed by using a finite element analysis. The hybrid prefabricated retrofit method consist of a Z-shaped side plate, a L-shaped lower plate, and a bottom plate containing an steel plate with openings. This shape has advantage that a retrofit method is possible regardless of the size of the beams and a follow-up process such as reinforcement bars placing are not required. The finite element analysis of hybrid Prefabricated retrofit method showed the most ideal stress distribution when the thickness of bottom plate was 10mm, the thickness of the L-shaped lower plate was 5mm, the thickness of the Z-shaped side plate was 2.5mm, and the bolt spacing was 200mm. The bending strength equation of Hybrid prefabricated retrofit method was proposed through the plastic stress distribution method in KDS 41 31 00. The result of Comparison the proposed equation with the finite element analysis, it is determined that the design of hybrid prefabricated retrofit method is possible through the KDS 41 31 00.
PURPOSES: This study aims to evaluate the resistance to chemical attack of combined organic and inorganic hybrid mortars as the repair materials (i.e., HRM mortar) used for concrete road facilities through a comparison with mortars made from cement repair materials (i.e., IRM mortar).
METHODS: Inorganic materials used as a binder and two mineral fillers were adopted to produce HRM mortars. The ratio of the main resin versus the hardener was fixed at 2:1. For comparison, IRM mortars made of cement repair materials were also manufactured. The mortars were exposed to chemical solutions, such as NaCl, MgSO4, Na2SO4, and H2SO4, with the same concentration of 5% after 7 days of curing. The compressive strength, compressive strength loss, mass ratio, and relative bulk density of the mortar samples exposed to the chemical solutions were measured at predetermined periods. In addition, a scanning electron microscope observation was performed to evaluate the microstructures and the products formed by the chemical reaction of the mortar samples.
RESULTS : As a result, the resistance to chemical attack of the HRM mortars was found to be much better than that of the IRM mortars, regardless of the types of attacking sources. This finding implies that HRM is a highly promising and versatile material because of its excellent resistance to chemical attack.
CONCLUSIONS: The application of the combined organic and inorganic hybrid mortars is a possible option for repair of concrete road facilities exposed to aggressive environments.
PURPOSES: The objective of this study is to evaluate the durable performance of combined organic and inorganic hybrid mortar as repair material (HRM mortar) for concrete road facilities via comparison with that of cement repair materials (IRM mortar).
METHODS : To produce HRM mortars, inorganic materials as binder and 2 mineral fillers were adopted. The ratio of main resin versus hardener was fixed at 1:2. For comparison, IRM mortars made with cement repair materials were also manufactured. Compressive, flexural, and bonding strengths were measured at predetermined periods. For durability assessment, the scaling resistance, freezing & thawing resistance, rapid chloride penetration resistance, and acid attack resistance of those mortars were experimentally monitored.
RESULTS: The durability performances of HRM mortars, especially with respect to freezing & thawing, rapid chloride penetration and acid attack, were identified to be much better than those of IRM mortars. This result implies that HRM is a highly promising and versatile material because of its excellent durability.
CONCLUSIONS: It is concluded that the application of the combined organic and inorganic hybrid mortars is possibly an option for the repair of concrete road facilities exposed to aggressive environments.
PURPOSES : The objective of this study is to evaluate the performance of combined organic and inorganic hybrid mortar used as repair materials (UM mortar) for concrete road facilities by comparison with cement repair materials (RM mortar).
METHODS: In order to produce UM mortar, four different levels of inorganic materials were adopted and the ratio of main resin to hardener was fixed at 1:2. For comparison, RM mortar made with cement repair materials was also produced. Fluidity, strength characteristics, length change, and freezing-thawing resistance of the mortars were measured at the predetermined periods. In addition, the microstructures of the mortars was performed on the 28-day mortar samples to examine the properties of the interfacial transition zone (ITZ).
RESULTS : It was observed that the mechanical properties, except for compressive strength, and freezing-thawing resistance of UM mortars were much better than those of RM mortar. Furthermore, showing a densified ITZ properties on the UM mortars from the microstructural observation, the usage of UM mortars exhibited a beneficial effect on the enhancement of mortar properties.
CONCLUSIONS: It is concluded that the application of combined organic and inorganic hybrid mortars is a possible option for the repair of deteriorated concrete road facilities.
This study develops a new hybrid passive energy dissipation device for seismic rehabilitation of an existing structure. The device is composed of a friction damper combined with a steel plate with vertical slits as a hysteretic damper. Analytical model is developed for the device, and the capacity of the hybrid device to satisfy a given target performance is determined based on the ASCE/SEI 7-10 process. The effect of the device is verified by nonlinear dynamic analyses using seven earthquake records. The analysis results show that the dissipated inelastic energy is concentrated on the hybrid damper and the maximum interstory drift of the SMRF with damping system satisfies the requirement of the current code.
To overcome shortcomings of fiber reinforced polymer (FRP), a hybridized FRP rebar was developed by the authors. This hybrid bar herein called “FRP Hybrid Bar” was fabricated by adopting advantages from two different materials, including glass fiber reinforced polymer (GFRP). Corrosion resistant characteristics of FRP Hybrid Bar were evaluated and the test results were explained in this paper. The use of the alternative reinforcement could allow concrete structures to extend life-span, to save maintenance and repair costs, etc. if the FRP Hybrid Bar was applied to RC structures located in a very corrosive environment, such as marina or harbor areas.
Fiber-reinforced polymer (FRP) bars have advantages as a construction material, including corrosion resistance, lightweight and high tensile strength. However, FRP rebars have shortcomings, such as low elastic modulus comparing to the steel rebar. With these reasons, FRP bars have not been widely used to reinforced-concrete (RC) structures. To overcome these shortcomings, the steel-hybrid GFRP rebars were developed by the authors at Korea Institute of Civil Engineering and Building Technology (KICT). Mechanical properties of the developed steel-hybrid GFRP rebars were experimentally evaluated through this study. Both tensile and bonding tests were conducted and the mechanical performance was investigated as well as corrosion resistance. As a result of all tests, elastic modulus, tensile strength and boding strength of the steel-hybrid GFRP rebars were all improved in comparison with fully GFRP rebars.
The purpose of this experimental research is to evaluate the workability and strength properties of hybrid fiber reinforced concrete containing amorphous steel fiber and organic fiber. For this purpose, the hybrid fiber reinforced concrete containing amorphous steel fiber(ASF) with polyamide(PA) and polyvinyl alcohol(PVA) fiber, respectively were made according to their total volume fraction of 0.5% for water-binder ratio of 33%, and then the characteristics such as the workability, compressive strength, and flexural strength of those were investigated. It was observed from the test results that the workability and compressive strength at 7 and 28 days were decreased and the flexural strength at 7 and 28 days was increased with increasing ASF and decreasing organic fiber.
This study presents an experimental study on compressive and flexural strengths of concrete reinforced by 3D Fiber Reinforced Polymer(FRP). This study is intended to investigate the potential of 3D FRP concrete composites against impact or explosive loadings. For the comparative study, non-reinforced specimen and specimens reinforced by 3D FRP are constructed and tested. 20mm×10mm 3D fiber and 25mm×20mm 3D fiber was set to be variable.
PURPOSES : In this study, an image analysis method is used to evaluate the pore structure characteristics and permeability of hybrid concrete.
METHODS: The binder weight of hybrid concrete is set to 400 kg/m3, 370kg/m3, and 350 kg/m3, and for each value of binder weight, the pore structure and permeability of concrete mixture is evaluated. The permeability of hybrid concrete is evaluated using a rapid chloride penetration test(RCPT).
RESULTS : The concrete pore structure characteristics of hybrid concrete reveals that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. The permeability of the hybrid concrete for all values was measured to be below 1000 C, which indicates a "Very Low" level of permeability relative to the evaluation standard of KS F 2711. Additionally, as the binder weight is decreased, there is a significant increase in the permeability of chloride ions.
CONCLUSIONS : In this study, the pore structure characteristics of hybrid concrete at different binder weights shows that as the binder weight is reduced, the entrained air is reduced and the entrapped air is increased. Consequently, chloride ion penetration resistance of the hybrid concrete is diminished. As a result, it is expected that this will reduce the concrete’s durability.
Due to the advantageous mechanical properties of the fiber reinforced polymeric plastics(FRP), their application in the construction industries is ever increasing trend, as a substitute of structural steel which is highly vulnerable under hazardous environmental conditions (i.e., corrosion, humidity, etc.). In this study, hybrid FRP-concrete composite pile (HCFFT) connection is suggested. The HCFFT is consisted of pultruded FRP unit module, filament wound FRP which is in the outside of mandrel composed of circular shaped assembly of pultruded FRP unit modules, and concrete which is casted inside of the circular tube shaped hybrid FRP pile. Therefore, pultruded FRP can increase the flexural load carrying capacity, filament wound FRP and concrete filled inside can increase axial load carrying capacity. In the study, connection capacity of HCFFT(small and mid size) is investigated throughout experiments and finite element method. From the results of experiments, we suggested the connection methods about HCFFT pile connection.
Pile foundations constructed by the fiber reinforced polymer plastic piles have been used in coastal and oceanic regions in many countries. Generally, fiber reinforced polymer plastic piles are consisted of filament winding FRP which is used to wrap the outside of concrete pile to increase the axial load carrying capacity or pultruded FRP which is located in the core concrete to resist the bending moment arising due to eccentric loading. In this paper, the analytical procedures of hybrid concrete filled FRP tube flexural members are suggested based on the CFT design method. Moreover, the analytical results are compared with the experimental results to obtained by the previous researches. The results of comparison analyses are performed to estimate the accuracy of the analytical procedure for hybrid FRP-concrete composite compression test, members under eccentrical loading.
An FRP(fiber reinforced polymer)-concrete hybrid hollow offshore wind power tower was proposed. To design this new-type wind tower, a design program was developed. It can design optimized sections automatically with the consideration of material nonlinearities. When the outer diameter and requested capacities of the hybrid tower are given, the developed program performs axial force-bending moment interaction analyses for one thousand sections of the tower and suggests ten economically optimized designs. The analysis considers material nonlinearities of concrete and FRP, and the confining effect of concrete. By using the developed program, example design processes were performed for a 5.0MW turbine and a 3.6MW turbine. The designing process was performed for the loads of wind power turbine and wind load. The designed section and analysis results showed the developed program suggested rational and satisfactory section designs.
고정반복법에 의한 암시적 HHT 시간적분법을 이용하여 3층 3경간 철근콘크리트 골조구조물을 수치해석모형과 물리적 분구조모형으로 나누어 실시간 하이브리드실험을 실시하였다. 물리적 부분구조모형으로는 1층 내부 비연성기둥 1개소가 선택되었고, 수치해석모형에 일축 방향의 지진하중을 시편이 심한 손상에 의하여 파괴에 이를 때까지 작용시켰다. 비선형 유한요소해석 프로그램인 Mercury가 실시간 하이브리드실험을 위하여 새로이 개발 및 적용되었다. 실험결과는 물리적 부분구조모형의 상부 수평방향 층간변위비를 OpenSees에 의한 수치해석시뮬레이션과 진동대실험의 그것과 비교하였다. 본 실험은 가장 복잡한 실시간 하이브리드실험 중의 하나이고, 하드웨어, 알고리즘 그리고 모형에 대한 기술적인 내용을 본 논문에 자세히 설명하였다. 수치해석모형의 개선, 물리적 부분구조 모형 접선강성행렬의 유한요소해석 프로그램에서의 평가 그리고 하중기반 보-요소의 요소상태결정의 연산시간을 줄이기 위한 소프트웨어의 개선이 이루어진다면 실시간 하이브리드실험과 진동대실험결과의 비교는 권장할 만하다. 그리고 "지진과 같은 동적하중하의 복잡한 구조물의 수치해석시뮬레이션"이라는 목적을 위하여 실시간 하이브리드실험은 동적하중에 대한 실험적 검증을 점진적으로 수치해석모형으로 대체하기 위한 저비용-고효율 실험법으로서의 가치를 충분히 가지고 있다고 할 수 있다.
Six concrete beam specimens reinforced with multiple layers of reinforcement and combinations of different reinforcement types (steel, GFRP, and CFRP bars), and four FRP bar-reinforced concrete beams with fibers were constructed and tested. An investigation was performed on load-carrying capacity, post cracking stiffness, cracking pattern, and ductility for all specimens. Addition of fibers and hybrid reinforcing with steel bars can be possible methods to overcome the low stiffness and ductility of FRP bar-reinforced beams.
The objective of this study is to examine the effect of preload and different types of hybrid FRPs (Fiber reinforced polymers) to the structural behaviors of reinforced concrete (RC) beams retrofitted with hybrid FRPs under sustaining loads. For the experimental study, FRP retrofitted RC beams are fabricated and subjected to four point loading. The experimental results show that preload and the orders of attached FRP layers have influence on FRP strengthening effect. Also, for the preliminary FEA study, FE models are generated to simulate the experiments. The analytical results are compared with the experimental results and show good agreements.
본 연구에서는 단부 철근콘크리트와 중앙부 철골로 이루어진 혼합구조보의 비선형 이력거동에 대한 해석 모형을 제시하였다. 해석을 위하여 IDARC2D 프로그램을 사용하였으며, 기존의 실험결과를 대상으로 적절한 모형화 기법과 계수를 제시하였다. IDARC2D의 다각형 모형은 부재의 초기강성을 과대평가할 수 있기 때문에, 먼저 혼합구조보의 초기강성을 적절히 표현할 수 있는 새로운 혼합모형을 도입하였다. 그리고 혼합모형을 이용하여 혼합구조보의 이력거동을 적절히 표현할 수 있도록 이력거동 계수들을 제시하였다. 끝으로 해석한 결과를 실험결과와 비교평가하였으며, 초기강성은 5%이내, 강도는 10%이내의 우수한 결과를 보였다.