검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 177

        21.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Precast concrete (PC) modules have been increased its use in modular buildings due to their better seismic performance than steel modules. The main issue of the PC module is to ensure structural performance with appropriate connection methods. This study proposed a PC modular beam system for simple construction and improved structural and splicing performance. This modular system consisted of modules with steel plates inserted, and it is easy to construct by bolted connection. The steel plates play the role of tensile rebar and stirrup, which has the advantage of structural performance. The structural performance of the proposed PC modular beam system was evaluated by flexural test on one reinforced concrete (RC) beam specimen consisting of a monolithic, and two PC specimens with the proposed PC modular beam system. The results demonstrated that the proposed PC modular beam system achieved approximately 86% of the structural performance compared to the RC monolithic specimen, with similar ductility of approximately 1.06 fold greater.
        4,000원
        24.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근, L형 도로측구 상 열화, 균열로 인한 유지보수 작업이 빈번해지고 있다. 본 논문에서는 쐐기 앵커를 이용한 L형 도로측구의 최적 설계에 대해 제시하고자 하였다. 해석 결과, 두 개의 쐐기앵커를 350mm로 관입시킨 경우에서 구조적 안정성을 충분히 확보하는 것을 확인하였다. 또한 3%의 개질유황 콘크리트 배합이 압축강도, 동결융해 등의 내구성 기준을 만족하였다. 반복하중에 대한 수치해석과 현장 평가가 수행 중에 있으며, 추후 해당 시스템의 적용성을 평가하기 위한 추적 조사가 이루어져야 할 것이다.
        4,000원
        26.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the Buckling restrained braces reinforced with engineering plastics that can compensate for the disadvantages in the manufacturing process of the existing buckling restrained brace. The proposed PC-BRB was fabricated to evaluate the reinforcement effect by carrying out a structural performance test and a full-scale two-layer frame test through cyclic loading test. As a result of PC-BRB's incremental and cyclic loading test, stable hysteresis behavior was achieved within the target displacement, and the compressive strength adjustment coefficient satisfied the recommendation. As a result of the real frame experiment, the strength of the reinforced specimen increased compared to the unreinforced specimen, and the ductility and energy dissipation increased.
        4,000원
        27.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to develop precast concrete modules that can be used as a booth and a single-story building with a large space. This precast concrete module is originally designed to have a hexagonal facade when the upper and lower parts, which are symmetrical about horizontal connection line, are combined. A structural design was conducted to ensure structural safety of these precast concrete modules and to extend the slope of the inclined members as far as possible. Then the finite element analysis was performed to estimate the lateral and vertical deflection of complete precast concrete modular structures. And to verify the structural safety of these precast concrete modules, weight loading tests were conducted on the upper and lower modules respectively.
        4,000원
        29.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 지반경계조건의 설정이 프리캐스트 아치구조물의 폭발저항성능 평가에 미치는 영향을 수치해석적 기법을 사용하여 파악하고자 하였다. 지반경계조건은 고정조건과 PML(perfectly matcher layer)을 이용한 경계조건의 두 가지로 적용하였으며, 폭발하중은 대상 구조물의 설계하중보다 큰 하중을 사용하여 경계조건의 영향을 명확히 비교할 수 있도록 하였다. 폭발압력의 분포 및 경로, 구조물에 발생하는 변위, 콘크리트의 파쇄여부, 콘크리트 및 철근의 응력을 비교․분석하였으며, PML을 적용하였을 때 지반 경계면에서 발생하는 반사파를 효과적으로 제거할 수 있음을 확인하였다. 또한, 이로 인해 구조물 기초부의 변위가 감소하는 것으로 나타났다. 하지만, 콘크리트의 파쇄여부, 콘크리트 및 철근에 발생하는 응력을 포함한 전반적인 구조물의 거동에는 뚜렷한 차이가 발생하지 않았다. 따라서 방호시설의 설계를 목적으로 폭발시뮬레이션을 수행하는 경우에는 지반경계조건에 고정조건을 적용하였을 때 안전측의 결과를 얻을 수 있으며, 해석시간이 단축되는 이점도 있으므로 이러한 면을 종합적으로 고려하여 지반경계조건을 고정조건으로 적용하는 것이 합리적이라고 판단된다.
        4,000원
        31.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper presents the design, analysis, and experimental evaluations of precast reinforced UHPC (ultra high-performance concrete) beams with a new design concept of non-uniform flexural members. With outstanding mechanical properties of UHPC which can develop the compressive strength up to 200MPa, the tensile strengths up to 8~20MPa and the tensile strain up to 1~5%, a non-uniform structural shape of UHPC flexural beams were optimally designed using three-dimensional finite element analysis. The experiments were carried out and compared with the design strength in order to verify the performance of them. Proposed non-uniform UHPC beams were evaluated by a series of three-point beam loading test as well as estimated by design bending and shear strength of members. The newly designed UHPC beams show excellent performances not only in transverse load capacities but also in deformation capacities.
        4,000원
        32.
        2018.04 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to pushover analyze existing reinforced concrete(RC) frames strengthened by L-type precast concrete(PC) wall panels. Cyclic loading tests were performed on the partially infilled reinforced concrete(RC) frames by L-type PC wall panels. Based on the results of experimental test, the nonlinear pushover analysis was practiced by using a computer program. The analysis models were designed with two ways according to the test result. The PC wall panel and the RC column exhibited almost composite behavior by using brace when push loading applied. The two structures also exhibited independent behavior when pull loading applied. The results of pushover analysis models generally conform to the experimental results. The ratios of the maximum lateral load measured in the strengthened specimens from the analysis varied between 0.93 and 1.01 in forward cycles, and between 0.84 and 0.90 in backward cycles. The initial stiffness values of the analysis were less than the test values for all strengthened specimens. The ratio of the initial stiffness obtained through testing compared to the values from the analysis varied between 0.72 and 0.90.
        3,000원
        34.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to make a generalized analytical based on the proposed experiments on reinforced concrete(RC) partially infilled frames by U-type precast concrete(PC) wall panels with openings. RC frame and PC wall panels were connected with different strengths. Therefore, we developed modified strut-tie model(STM) with two seismic retrofitting specimens and conducted a nonlinear analysis by using a computer analysis program. Based on the test results, truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix- A. As a result, the modified STM analysis results were very similar to the experimental results. As a result of the load-displacement curve comparison, the failure load were similar within 5∼17% of error range. In particular, the experimental results and the results of modified STM analysis show that the failure behavior almost matched.
        4,200원
        35.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cyclic loading test was performed on the partially infilled reinforced concrete(RC) frames by L-type precast concrete(PC) wall panels with the connections of two different strength. Based on the results of experimental test, the nonlinear analysis was practiced with modified strut-tie model(STM) method by using a computer program. Truss member of modified STM was designed, applying the strut-tie model theory of ACI 318M-11 Appendix-A. Modified STM was designed with two ways according to the test result. PC wall panel and RC frame were assumed to composite when push loading applied. The PC and RC structures were also assumed to behave non-composite and those two structures connected with link(top connector) when pull loading applied. The connection was designed by using elastic link of program. The results of analytical modified STM process generally conform to the experimental results. The failure load and the failure mode of the specimens could be predicted using modified STM. The ratio of failure load measured in specimens to analytical values were between 0.83∼1.16. The member or connection which was failed in experiment yield in the results of modified STM. The failure mode perfectly matched.
        4,500원
        36.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a study on noise reduction characteristics of the precast floating track system, being developed as measures to mitigate noise and vibration of existing as well as constructing elevated railroad stations, is presented using numerical analysis. One of the most prominent sound analysis program, Virtual Lab., is utilized in investigating noise reduction performance of the precast floating track system, and structural velocity data, obtained from vibration analysis on a model-updated elevated railroad station considering vehicle-track-structure interaction, are used for the input of the sound analysis. The sound analysis is performed using the finite element method, and noise reduction performance before and after installing the precast floating track system is compared at three enclosed areas in the Daecheon Station, selected as a representative of elevated railroad stations in this nation. From the comparison result, it is seen that the precast floating track system can decrease noise by average of 5dB∼8dB when the Saemaeul train passing through the station and 10dB∼15dB when the KTX train passing through. Also, the noise reduction characteristics is different depending on the type of train and the distance from the track.
        4,000원
        37.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When reinforcing an existing reinforced concrete beam-column building with a precast concrete panel, special connection between the PC member and the RC member is required to solve the time dependent deformation of the RC member and to receive the large shear forces. The aim of this study is to obtain the shear strength of upper connection between the existing RC beam-column and infilled PC wall panels in experimentally and theoretically. Thus, the static shear loading tests were conducted on the 6 specimens with the plate connection. Shear failure was resulted from the weakest portion of interior PC panel, exterior RC, and the connection, when the PC portion which located at the center of specimen was pulled upward from the bottom. T he experimental result was compared with analytical result from ACI 318M-14 Chapter 17 for the shear strength of post-installed anchor and PCI Handbook 7th edition 6.8 Structural Steel Corbel (PCI Design Handbook 7th edition, 2010) for the strength of cast-in H-beam. The analytical and experimental results show final failure at the same location. The failure loading of experiment showed larger than average 6% to that of the analysis.
        4,500원
        38.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As a preparation of a design standard regarding road facilities in terms of reliability based optimum design examples, such as cantilever columns for traffic lights, optimum design in deterministic and probabilistic ways for the foundation of traffic lights poles are proposed. Most of the previous study have focused on the foundation surrounded by cohesionless soil. However, the design would be governed by risky condition. Therefore the resistance by clay-soil is investigated compared with other design specifications. In deterministic optimization, GRG method is applied. It is found that both geometries of deep and shallow foundation provides optimum values. The resistance of cohesive soil is selected to represent the ultimate limit states, in terms of sliding, overturning and bearing pressures from super structures to the foundation under external loads. Example foundations with varying height of columns for traffic lights are optimized about 30% decreased embedded depth of foundation. The optimum coefficients of resistant and load factors may need to be developed with design load combinations in order to prepare design specifications as the next step.
        4,200원
        39.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, a design concept of post-tensioned precast bridge piers was proposed to improve seismic behavior of the bridge pier. Mild reinforcing bars are placed continuously along the height of the column. Prestressing tendons are also provided to obtain re-centering capability for seismic events. Arrangement of the axial steels to prevent buckling of rebars at plastic hinge region was suggested and enhanced seismic performance was verified by experiments. Moment-curvature analyses were performed to evaluate the effect of effective prestress on seismic behavior after verifying the calculation method by cyclic tests of the precast columns. A real bridge pier was designed to investigate the seismic performance according to different level of effective prestress. Level of effective prestress showed obvious effect on crushing displacement but negligible effect on lateral displacement at fracture of tendons and reinforcements.
        4,000원
        1 2 3 4 5