검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 128

        1.
        2024.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Daemadeung, located in the estuary of the Nakdong River, is formed by sand dunes and possesses well-developed intertidal flats. This study aimed to investigate the habitat of benthic microalgae, photosynthetic pigments, and photosynthetic efficiency in the intertidal flats of Daemadeung from January to December 2011. The inorganic nitrogen content in the sediment pore water was primarily composed of ammonium, while nitrate+nitrite was dominant in the upper layer water. The concentration of chlorophyll a and fucoxanthin in the sediment surface was significantly higher than the mean of all the sediment layer. The average Fv/Fm of benthic microalgae during the entire survey period was 0.52±0.03, with the highest value (0.61±0.08) observed in February. The rETRmax showed a seasonal trend, being high from spring to early autumn (April to October) and low from winter to early spring (January to March, November, December), with the highest value (153.05±2.30 μmol electrons m-2 s-1) in July and the lowest (38.49±5.17 μmol electrons m-2 s-1) in January. The average Fv/Fm of diurnal microalgae was 0.48±0.03, with the highest value (0.61±0.08) observed at noon. The rETRmax showed a highest peak at noon (54.24±11.35 μmol electrons m-2 s-1) and reached its lowest point at 16:00 (26.17±4.75 μmol electrons m-2 s-1). These findings suggest that the productivity of benthic microalgae varies significantly depending on the survey time and sediment depth. Therefore, to quantify the productivity of benthic microalgae using Diving-PAM, surveys should be conducted based on tidal conditions, and simultaneous pigment analysis of sediment layers should also be performed.
        4,600원
        2.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        일반적으로 속도 펄스를 가진 지반운동이 속도 펄스가 없는 지반운동에 비하여 구조물에 보다 큰 손상을 줄 수 있다고 알려져 있다. 지진가속도기록으로부터 속도 펄스의 유무의 판정과 이를 정량화하는 연구가 현재 많이 진행되어 오고 있다. 기존 지진기록들을 단 층으로 떨어진 거리를 기준으로 원거리 지진과 근거리 지진으로 구분하였다. 또한, 근거리 지진은 속도 펄스의 유무를 정량화하여 펄 스를 가진 지진과 펄스를 가지지 않은 지진으로 구분하였다. 최종적으로 각 지진그룹별로 40개의 원거리지진, 40개의 속도 펄스를 가 진 근거리 지진과 40개의 속도 펄스를 가지지 않은 근거리 지진을 선정하였으며, 총 120개 지진가속도 기록을 지진취약도 평가를 위 한 지진해석에 사용하였다. 세 그룹의 지진을 이용하여 납-고무받침과 탄성받침을 가진 두 종류의 예제교량에 대한 지진응답을 평가 하여 확률론적 지진요구도 모델을 작성하였다. 확률론적 지진요구도 모델을 이용하여 지진취약도 해석을 수행하여 속도 펄스의 유무 에 따른 지진취약도 영향을 분석하였다. 지진파의 속도 펄스 유무에 따른 지진취약도 곡선의 비교 결과로부터, 속도 펄스를 가진 지진 의 지진취약도가 속도 펄스가 없는 지진의 지진취약도가 약 3배~5배 정도 정도 크게 나타난다. 이는 속도 펄스를 가진 지진의 경우가 그렇지 않은 지진의 경우에 비하여 교량의 손상 피해가 크다는 것을 의미한다.
        4,500원
        3.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        자기공명영상장치(magnetic resonance, MR)/양전자 방출 단층촬영 장치(positron emission tomography, PET)는 두 가지 의료장치가 결합한 하이브리드 시스템으로써 MR의 해부학적 정보와 PET의 기능적 정보를 동시에 획득할 수 있는 최신 의료장치이다. 일반적으로 MR/PET의 우수한 팬텀 영상의 질 획득과 평가를 위하여 팬텀 내에 전기전도도가 낮은 액체 물질과 방사성동위원소를 주입하고, UTE MR 펄스 시퀀스를 적용한 감쇠 보정된 PET 영상을 획득한다. 본 연구의 목적은 MR/PET 전용 팬텀에서 물 대체물질로써 NaCl과 NaCl+NiSO4 물질에 따른 UTE MR 펄스 시퀀스를 획득하고, 감쇠 보정된 PET 영상의 질을 평가하고자 한다. 정량적 분석을 위하여 대조도 회복비(contrast recovery, CR), 신호대잡 음비(signal to noise ratio, SNR), 변동 계수(coefficient of variation, COV)를 적용하였다. NaCl 물질 기반 UTE MR 펄스 시퀀스를 적용한 PET 영상의 질이 CR은 1.38배, SNR은 1.18배가 증가하였고, COV는 1.18배 감소함을 확인할 수 있었다. 결론적으로, MR/PET 전용 팬텀을 활용한 신호의 획득 가능성을 확인하였고, UTE MR 펄스 시퀀스는 해부학 적 정보와 PET 영상의 질 향상에 필수적임을 확인할 수 있었다.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 자기공명영상 획득을 위한 시뮬레이션 도구가 개발되어 오랜 시간이 소요되는 임상 연구를 대체할 수 있게 되었다. 이에 본 연구에서는 MRiLab 시뮬레이션을 사용하여 부가인자인 에코 시간의 변화에 따라 경사에코 펄스 시퀀스가 적용된 뇌 T2 강조 영상을 획득하여 영상의 신호 및 노이즈의 변화를 정량적으로 평가하고 경향성을 파악하고자 한다. 이를 위해 실제 MRI 장비를 기반으로 새롭게 개발된 MRiLab simulation tool을 사용하여 모든 파라미터를 같게 고정한 후 TE만을 20~95 ms범위에서 5 ms 간격으로 각각 설정하여 경사에코 펄스 시퀀스가 적용된 뇌 T2 강조 영상을 획득하였다. 획득된 영상들의 신호 및 노이즈 특성 변화를 정량적으로 평가하기 위해 신호대잡음비 및 대조대잡음비를 측정하였다. 결과적으로, TE가 증가할수록 SNR은 감소하고 CNR은 증가하는 경향을 보였다. 이는 TE가 증가할수록 관심 영역으로 설정된 뇌척 수액 신호는 일정하게 유지되는 반면 노이즈는 증가하였으며, 백그라운드로 설정된 백질의 경우 신호가 감소함과 동시에 노이즈가 증가한 것이 원인으로 분석된다. 결론적으로, 진단에 용이한 경사에코 펄스 시퀀스가 적용된 뇌 T2 강조 영상을 획득하기 위해서는 그 목적에 따라 적합한 TE를 설정하는 것이 중요함을 확인하였다.
        4,000원
        5.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 고속 스핀에코 기법의 T2 강조영상 획득에 있어 온도 상승을 최적화하기 위한 에코 개수(echo train length, ETL) 25를 기반으로 재자화 펄스의 범위에 따른 온도 변화와 이에 따른 신호대잡음비(signal to noise ratio, SNR) 분석을 통한 합리적인 영상 파라미터를 제시하고자 하였다. 온도 변화측정은 수소원자 공명주파수(proton resonance frequency shift. PRF) 기법을 활용했으며, 재자화 펄스의 각도(flip angle, FA)에 따른 온도 상승을 측정하였다. 온도 변화는 재자화 펄스 90도 인가 시에 약 0.202±0.023°C로 증가했으며, 이는 최소 FA인 60도(약 0.196±0.024°C)와 가장 유사하게 나타났다. 또한, 그 영상의 SNR은 FA 120도과 150도에 비해 FA 90도에서 약간 감소하는 경향이 나타났지만(약 12.5%), FA 180도와 비교하여 큰 차이는 발생하지 않았다 (FA 90도=349.66±3.68; FA 180도=357.68±3.21). 이 결과들은 고속스핀에코 기법에서 ETL 25를 사용한 빠른 영상획득 시간을 기반으로 합리적인 영상신호와 재자화 펄스에 의한 최소 온도 상승을 나타내며, 이는 인체 MR 안전기준을 충분히 보장하는데 기여할 수 있다. 특히, ETL 25와 결합된 90도 FA 사용은 가속화된 영상획득 시간, 합당한 T2 영상의 SNR, 그리고 최적의 인체 온도 증가를 위한 고속스핀에코 기법에서의 최적화된 영상 파라미터가 될 수 있을 것으로 사료된다.
        4,000원
        8.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the physical changes in 119 paramedics transporting equipment at the emergency site and performing post-cardiopulmonary resuscitation through experiments. First, the average heart rate increased by about 25 times comparing CPR was performed without physical load and with personal protective equipment after moving equipment. In the third quartile, it increased to about 27 times. Second, when CPR was performed without physical load, and CPR was performed after moving the equipment with personal protective equipment, both the body temperature was raised and the rising body temperature was measured within normal body temperature. Third, the change in respiration rate increased by 7 times on average comparing CPR was performed without physical load and CPR was performed after moving the equipment while wearing personal protective equipment. In the third quartile, it increased to about 11 times. Finally, the change in blood pressure increased by 26.6 mmHg on average comparing CPR was performed without physical load and with wearing personal protective equipment after moving the equipment, and increased by 31.2 mmHg on average in the third quartile.
        4,000원
        9.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we break away from the method of removing and inspecting the GDI injector, measure the pressure change of the fuel rail pressure sensor when driving the GDI injector of a vehicle equipped with the GDI fuel system, and compare the results. analyzed.There was a pressure change in the fuel rail pressure sensor from the general drive GDI injector. There was no pressure change in the fuel rail pressure sensor when driving the GDI injector without injecting fuel. You can check the fuel injection status in the pressure change data of the fuel rail pressure sensor without removal the GDI injector.
        4,000원
        12.
        2020.06 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The present study demonstrates the effect of magnetic pulse compaction and spark plasma sintering on the microstructure and mechanical property of a sintered W body. The relative density of green specimens prepared by magnetic pulse compaction increases with increase in applied pressure, but when the applied pressure is 3.4 GPa or more, some cracks in the specimen are observed. The pressureless-sintered W shows neck growth between W particles, but there are still many pores. The sintered body fabricated by spark plasma sintering exhibits a relative density of above 90 %, and the specimen sintered at 1,600 oC after magnetic pulse compaction shows the highest density, with a relative density of 93.6 %. Compared to the specimen for which the W powder is directly sintered, the specimen sintered after magnetic pulse compaction shows a smaller crystal grain size, which is explained by the reduced W particle size and microstructure homogenization during the magnetic pulse compaction process. Sintering at 1,600 oC led to the largest Vickers hardness value, but the value is slightly lower than that of the conventional W sintered body, which is attributed mainly to the increased grain size and low sintering density.
        4,000원
        13.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.
        4,000원
        14.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선체구조의 품질검사 중 가장 일반적인 방법의 하나는 비파괴검사이다. 하지만 복합소재 선체는 강화재와 수지로 구성된 여러가지 재료가 섞여 있고 또 생산환경과 작업자에 따라 FRP(Fiber-Reinforced Plastics) 제작품질에 차이가 발생할 가능성이 크기 때문에 정확한 검사평가는 쉽지 않은 일이다. 특히 FRP 선박의 경우에는 다른 구조물보다 두께가 매우 두껍고 주로 수척층 공법을 이용하기 때문에 더욱 그렇다. 초음파 탐상의 조건 중 검사체의 밀도가 매우 중요하기 때문에 본 연구에서는 FRP 선박 제작에 널리 사용되고 있는 소재와 유리섬유강화재 중량 비율로 제작된 선박의 외판을 검사체로 선정하고, Pulse-Echo 초음파 탐상기를 활용하여 GFRP(Glass Fiber-Reinforced Plastics) 선체 외판의 초음파 탐상을 위한 적정 조건을 조사하였다. 1.00 MHz, 2.25 MHz, 5.00 MHz 세 종류 탐촉자로 A-Scan 을 실시하였으며 선체 외판의 두께 검사결과와 비교분석함으로써 적정 초음파 탐상 조건을 찾고자 하였다. 연구결과 탐촉자의 초음파 주파수가 높아질수록 수신자의 반사파 음향 속력을 감소시켜야 더 정도 높은 두께 측정 결과를 얻을 수 있었으며, 상대적으로 낮은 초음파 주파수 탐촉자에서 더 적은 오차가 발생함을 확인할 수 있었다.
        4,000원
        19.
        2018.04 구독 인증기관·개인회원 무료
        목 적:MRI의 RF에 의한 맥박 산소측정기 센서의 열발생으로 인해 환자에게 화상이 발생한 사례가 다수 보고되 었다. 따라서 이번 연구의 목적은 실제 임상에서 사용 되는 MRI 시퀀스에서의 열 발생을 정량적으로 측정하고자 하였다. 대상 및 방법:3.0 T MRI(Ingenia, Philips, Netherlands)장치와 광섬유 온도계(FTX-301-PWR 3ch Temperature transmitter, OSENSA, Canada), 하이드록시에틸 셀룰로즈와 염화나트륨을 혼합한 겔 용액을 넣은 팬텀을 사용하였다. 위치 변화에 따른 실험은 맥박 산소측정기를 중앙부와 좌측 외측부에 설치한 후 세 부위의 isocenter에서 SAR 3.2 W/kg으로 15분간 스캔하며 온도를 측정하였다. 임상 조건 에서의 온도측정 실험은 맥박 산소측정기를 환자의 왼손 위치인 팬텀 좌하측 측면에 고정하고, Brain, C-spine, L-spine의 임상조건으로 스캔하며 온도를 측정하였다 결 과:맥박 산소측정기의 위치에 따른 실험 중 정중앙 위치에서는 isocenter 1, 2, 3에서 각각 1.6, 2.7, 1.2 ℃의 온도상승을 나타냈고, 좌측 외측부 위치에서는 각각 10.8, 9.9, 9.9 ℃의 온도상승을 나타냈다. 임상조건에서는 Brain, C-spine, L-spine 스캔에서 각각 10.3, 6.3, 3.9 ℃의 온도상승이 나타났다. 결 론:본 연구를 통해 MRI의 RF로 인한 맥박 산소측정기의 발열현상과 이로 인한 접촉 부위의 화상발생 가능 성을 직접적인 온도측정 실험을 통해 확인할 수 있었다.
        20.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        목 적:MRI의 RF에 의한 맥박 산소측정기 센서의 열발생으로 인해 환자에게 화상이 발생한 사례가 다수 보고되었다. 따라서 이번 연구의 목적은 실제 임상에서 사용 되는 MRI 시퀀스에서의 열 발생을 정량적으로 측정하고자 하였다. 대상 및 방법:3.0 T MRI(Ingenia, Philips, Netherlands)장치와 광섬유 온도계(FTX-301-PWR 3ch Temperature transmitter, OSENSA, Canada), 하이드록시에틸 셀룰로즈와 염화나트륨을 혼합한 겔용액을 넣은 팬텀을 사용하였다. 위치 변화에 따른 실험은 맥박 산소측정기를 중앙부와 좌측 외측부에 설치한 후 세 부위의 isocenter에서 SAR 3.2 W/kg으로 15분간 스캔하며 온도를 측정하였다. 임상 조건에서의 온도측정 실험은 맥박 산소측정기를 환자의 왼손 위치인 팬텀 좌하측 측면에 고정하고, Brain, C-spine, L-spine의 임상조건으로 스캔하며 온도를 측정하였다 결 과:맥박 산소측정기의 위치에 따른 실험 중 정중앙 위치에서는 isocenter 1, 2, 3에서 각각 1.6, 2.7, 1.2 ℃의 온도상승을 나타냈고, 좌측 외측부 위치에서는 각각 10.8, 9.9, 9.9 ℃의 온도상승을 나타냈다. 임상조건에서는 Brain, C-spine, L-spine 스캔에서 각각 10.3, 6.3, 3.9 ℃의 온도상승이 나타났다. 결 론:본 연구를 통해 MRI의 RF로 인한 맥박 산소측정기의 발열현상과 이로 인한 접촉 부위의 화상발생 가능성을 직접적인 온도측정 실험을 통해 확인할 수 있었다.
        4,000원
        1 2 3 4 5