        101.
        2018.04 서비스 종료(열람 제한)
        The loss of prestress in cable supported structure is a direct cause of structural deterioration of the structure. Thus, measurement and evaluation of the tensile force acted on a strand consist of the cable system have been a significant technological factor. However, a measurement method of tension for each of strands is not proposed, as well as conservative assessment of cable system is bing adopted in industrial application. This paper proposes a new and effective method for measurement of tensile force in a strand based on ultrasound. Electromagnetic acoustic transducer(EMAT) is used for generation of ultrasound. Tensile force acting on a strand can be measured by characterization of guided waves that propagate along the boundary of geometry. Consequently, proposed method is experimentally verified by some experiments using seven-wire strand.
        102.
        2017.11 KCI 등재 서비스 종료(열람 제한)
        In this paper, we introduce a robot-assisted medical diagnostic system that enables remote ultrasound (US) imaging to be applied to the conventional telemedicine, which has been possible only with interviewing or a visual exam. In particular, a master-slave robot system is developed that ultrasonic diagnosis specialist can control the position and orientation of US probe in the remote place. The slave robot is designed to be compact, lightweight, and hand-held so that it can easily transfer to the remote healthcare center. Moreover, 6-degree-of-freedom (DOF) probe motion is possible by the robot design based on Stewart platform. The master device is also based on a similar structure of the slave robot. To connect master and slave system in the wide area network (WAN) environment, a hardware CODEC was developed. In this paper, we introduce the detail of each component and the results of the recent experiments conducted in the remote sites by the developed robotic ultrasound imaging system.
        103.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 혈액 검사 결과인 전립선특이항원(PSA) 및 전립선특이항원밀도 (PSAD), 전립선 경직장 초음 파 (TRUS)를 이용한 전립선 전체용적 (TPV), 나이등 변수와 전립선이행대용적 (PTZV)과 상관관계를 연구 하여 임상적 지표로 활용하고자 한다. 2007년 6월부터 2016년 4월 까지 전립선에 대한 치료력이 없는 건강 한 30대 성인 남성으로 TRUS와 PSA, PSAD 혈액 검사를 실시한 총 68명을 후향적으로 분석하였다. 초음파 장비는 Siemens Acuson sequoia 512)와 탐촉자 Siemens EC~10C5 Endocavitary를 이용하였다. 통계 처리의 경 우, SPSS 18.0 각 변수와 표준 편차의 평균을 계산하는 데 사용하고, 피어슨 상관관계 분석을 수행 하였다. 변수들의 기술 통계량은 TPV; 24.27±6.60, PTZV; 6.99 ±6.60, PSA; 2.12±2.76와 PSAD; 0.281±0.1이고. 전립선 이행용적과 변수의 상관 계수는 PSAD; 0.831, TPV; 0.707, 나이; 0.398, 그리고 PSA; 0.118이었다. PSA 및 연령과의 양의 크기의 상관관계지만, PSAD, TPV가 높은 상관관계를 보였다. 따라서, 기저 질환이 없는 30 대 남성의 PTZV는 TPV와 PSAD를 통해 예측할 수 있다.
        104.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 초음파 검사실의 검사환경 설정에 있어 실증적인 기초자료를 제공하는 것에 그 목적 을 두고 새로운 초음파 검사실의 검사환경을 설계함에 있어 검사실의 적정조도를 설정하는데 기초자료로 제공하고자 한다. 방법으로는 부산에 소재하고 있는 종합병원 6군데 48곳의 초음파 검사실을 대상으로 조 도와 관련된 초음파실 환경을 조사하고 초음파 검사대상자에게 초음파 검사실 환경에 대하여 설문조사를 실시하였다. 결과로는 초음파 검사실 차폐체의 종류에서는 성별, 연령별, 검사부위에 따른 분석에서 모두 Door+Curtain에서, 광원의 종류에서는 LED, 광원조절기가 필요하다에서 점수가 높게 나타났다. 초음파 검 사실 환경조사에서는 초음파 검사실 조도 밝기는 평균 10 Lux로서 WHO와 CEC에서 권고하는 조도 밝기 범위에 포함되고 있었으며 초음파 검사 대기실 조도 밝기(초음파 검사 대기실, 복도)는 평균 300∼800 Lux 를 나타내어 KSA 3011에서 권고하는 병원의 조도환경인 300 Lux이상을 만족하였다. 결론적으로 초음파 검 사 대상자의 일반적인 배경과 초음파 검사실 관련 환경 요인을 분석한 결과를 토대로 향후 초음파 검사실 환경을 개선하거나 새로운 검사실을 설계함에 있어 기초자료로 제공하고자 한다.
        105.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        만성간질환(Chronic diffuse hepatopathy)의 진단은 간경화, 간부전, 간암으로 인한 사망률과 유병율을 감소 시키는 중요한 임상과제 중 하나이다. 이에 본 연구에서는 초음파진단 영상을 바탕으로 간탄력도검사(Fibro scan)를 통해 지방간, 만성간질환을 예측할 수 있는 기준을 알아보고자 하였다. 280명의 환자를 대상으로 혈청학적 검사, 간탄력도 검사 측정값(kPa)을 분석하였으며 ROC 곡선분석을 이용하여 지방간 및 만성간질 환을 예측을 위한 간탄력도 측정값의 cut-off value를 결정하였다. 혈청학적 검사에서 Bililubin, PT(prothromb in time)은 질병예측에 관련성이 없었으며(p=0.243, p=0.115), 혈당과 중성지방수치는 지방간에서 의미 있는 차이를 보이며 높게 나타났다(p<0.05). 간탄력도 측정값은 정상 대조군, 지방간, 만성간질환 순으로 높게 측 정되었으며 만성간질환 예측을 위한 cut-off value는 10.3 kPa(AUC 0.98, Sensitivity 94.94%, Specificity 94.9 3%)로 결정하였다. 따라서 정량적인 평가로 만성간질환 환자의 진단에 일차적인 도구로 활용될 것으로 사 료된다.
        106.
        2017.06 KCI 등재 서비스 종료(열람 제한)
        This study investigated the risk factor of Gallbladder stone in Busan and Kyungnam area. The subjects of the experiment was performed with patients by abdominal ultrasonography among the patients who came to the P hospital from June 2016 to December 2016. Among them, risk factors were analyzed on 353 people at the same time when abdominal ultrasonography and hematological test. The statistical analysis of risk factors related to the Gallbladder stone was performed by independent t-test and chi-square test. In consider of difference verification result for calculations odds ratio about independent variables, multiple logistic regression analysis to conduct verify adequacy by calculating forecasting model from variable. As a result, Gallbladder stone risk factors have relevance to age ɤGTP with probability model and values to calculated. Age was showed sensitivity 49.7%, specificity 82.2%, receiver operating characteristic area under curve 0.724. Forecasting probability sensitivity 69.3%, specificity 62.4%, receiver operating characteristic area under curve 0.699 showed, ɤGTP confirmed validity of forecasting model
        107.
        2017.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 영상의 노이즈 감소를 위한 복합필터 제안과 간 초음파영상에서 노이즈 제거를 통한 영상품질의 향상으로 정확한 영상 해석에 도움을 주고자 하였다. 실험은 ATS-539 다목적용 초음파팬텀을 이용하여 Gaussian blurring filter, Sharpening filter, Median filter의 조합으로 상위 7개의 복합필터를 선정하고 이를 간 초음파영상에 적용하였다. 그 결과 상위 7개 복합필터 적용하였을 때 SNR, CNR, MSR 값이 모두 증가하는 것으로 나타났다. 이 중 복합필터 1과 2가 가장 높은 값을 나타내었다. 또한 PSNR 30 dB이상, SSIM 1에 가까운 결과값을 나타내어 영상의 손실률이 적음을 알 수 있었다. 따라서 본 연구에서 제안한 복합필터의 적절한 적용은 정확한 영상의 판독과 해석에 도움을 줄 수 있을 것이다.
        108.
        2016.12 서비스 종료(열람 제한)
        High intensity focused ultrasound (HIFU) treatment of uterine myoma is a non-invasive procedure that uses high intensity, focused ultrasound to heat and destroy the tissue of uterine myoma. The history of using therapeutic ultrasound dates back to the early 20th century, and since, the technique has been continuously improved to an extent that the breadth of its clinical applications, both diagnostic and therapeutic, justify the integral role it plays in medicine today. HIFU treatment requires that ultrasound beams be focused on targeted uterine myoma. Due to significant energy dissipation at the focus, temperatures within tissues increase to more than 65℃, and destroy diseased tissue. This technology can achieve precise "ablation" of myoma tissue, and because it destroys diseased tissue non-invasively, it is also known as "Non-invasive HIFU surgery". Development of this technology significantly broadened the range of treatment options for patients suffering from uterine myoma. Furthermore, in contrast to surgery, HIFU requires only a short period of hospitalization and has a low complication rate. Today, HIFU is being used more frequently to treat adenomyosis, but its increased use has led to the reporting of more complications. Here, the authors report a case of uterine perforation after HIFU ablation for adenomyosis.
        109.
        2016.11 서비스 종료(열람 제한)
        The desulfurization of untreated petroleum oil is required in order to comply with stringent environmental regulations. Ultrasound-assisted oxidative desulfurization (UAOD) is an innovative technology for sulfur removal in order to avoid the environmental hazards associated with the combustion of sulfur compounds in raw diesel oil. In this study, diesel oil is treated through UAOD. The effects of ultrasound time (6-30 min), amplitude (20-60%), phase transfer agent (100-500mg), catalyst dosage (10-500mg), H2O2 concentration (30-50%v/v), organic to aqueous phase (OP:AP) ratio (50:50-90:10) and reaction temperature (30-70℃) were examined. The screening analysis used is the definitive screening design that statistically determines the parameters that have a significant effect on the oxidation of diesel oil. Results indicate that significant factors (p-value < 0.5) where ultrasound time, amplitude, catalyst dosage and reaction temperature; while the phase transfer agent, H2O2 concentration and OP:AP ratio were insignificant (p-value > 0.5) on the response of sulfur conversion in the untreated diesel oil. This study concludes that the essential factors to achieve deep desulfurization in diesel oil include ultrasound time, amplitude, H2O2 concentration and reaction temperature which are key factors in the oxidation of sulfur compounds to achieve low sulfur containing diesel oil.
        110.
        2016.10 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        The effects of ultrasound-assisted extraction (UAE) on the physicochemical and sensory characteristics of coffee beverage were investigated. Coffee powder (4 g) was soaked into 80 mL distilled water and extracted for 15, 30, 60, 120, 180, 240, or 300 sec at 60℃ in an ultrasonic bath (40 kHz, 300 W). Hot-water extraction (HE) at 80℃ for 300 sec was used as a control. Content of soluble solids in coffee beverage prepared by UAE (60~300 sec) was same or higher than those of HE, however, no significant differences were observed among the four beverages extracted for more than 120 sec. Clarity and browning index of beverage prepared by UAE (15 sec) and by HE were significantly higher and lower, respectively, compared to those of the other. Content of phenolic compounds was lower and higher respectively, in beverage prepared by UAE (15 sec, 30 sec) and UAE (60~300 sec) than by HE. DPPH radical scavenging activity was highest in beverage prepared by UAE (15 sec) and HE. Sensory evaluation showed that color, aroma, taste, and overall acceptability were rated with the best score for beverage prepared by UAE (15 sec) and the worst score for beverage prepared UAE (120~300 sec). Therefore, ultrasound-assisted extraction can be used for improving quality of coffee beverage.
        111.
        2016.06 KCI 등재 서비스 종료(열람 제한)
        초음파 장비는 여러 질환을 진단하는 장비로서 널리 사용되고 있으나, 초음파영상 품질의 평가방법에서 는 정량적 표준이 없는 실정이다. 따라서 본 연구에서는 ATS-539 다목적 팬텀 내 8 mm 표적의 파라미터로 서 주파수, Dynamic range, 초점수를 변화하여 예민도의 SNR과 영상의 히스토그램을 분석하고 왜곡도를 측 정하여 표적별 적합한 주파수 및 파라미터를 도출하여 초음파영상의 병변 진단율을 향상 하고자 한다. 실 험재료는 초음파 장비, ATS-539 다목적 팬텀을 사용하며, 실험방법은 영상 평가 팬텀의 8 mm를 주파수(2, 3, 4 MHz, 하모닉 3, 4, 4.5 MHz), Dynamic range(58, 68, 78, 88, 98), Focus(2, 4, 6개)를 변화시키면서 85장의 영상을 획득한다. 8 mm 영상의 예민도를 Image J 프로그램에서 각 표적별 SNR을 측정하고, 왜곡도는 신호 의 히스토그램에서 백그라운드 값을 뺄셈하여 측정한다. 측정 결과 값에서 상위 40% 결과에서 파라미터 변화에 따라 예민도의 SNR, 왜곡도의 변화양상의 데이터 값을 산출하여 초음파 장비에서 적절한 영상의 품질을 나타내는 파라미터를 도출하였다. 결과는 초점수가 증가하면 SNR이 높고 왜곡도가 감소하며, 주파 수 4 MHz에서 SNR값이 높고 왜곡도가 감소하였다. 그리고 Dynamic range 88, 98에서 최적의 영상을 나타 내었으며, 실험 결과값을 기초로 초음파영상의 품질을 평가한다면 보다 정확한 초음파 진단이 가능할 것으 로 사료된다.
        112.
        2016.04 KCI 등재 서비스 종료(열람 제한)
        유방암에 관한 사회적인 관심이 증가되고 있는 가운데 진단의 가장 기본이 되는 검사는 유방 X선 촬영 과 유방 초음파 검사이다. 특히 유방 미세석회화는 조직학적 진단을 필요로 하며 유방 미세석회화 조직검사를 시행하고 있다. 이에 미세석회화 진단에 기본이 되는 X선 유도 하 조직검사(needle localized open biop sy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)를 분석하여 평가하고자 한다. 유방 미세석회화를 주소로 내원한 환자에서 확대 촬영을 시행한 241예를 대상으로 X선 유도 하 조직검 사(needle localized open biopsy)와 초음파 유도 하 조직검사(sono guided core needle biopsy)의 연령대 별 분 포와 병소의 위치를 분석하고 확대촬영 시행 후 이루어진 검사를 분류해서 X선 유도 하 조직검사와 초음 파 유도 하 조직검사의 빈도를 분석하고 악성과 양성의 결과를 확인 하였다. 그 결과 X선 유도 하 조직검 사(needle localized open biopsy)가 64예(26.6%)로 초음파 유도 하 조직검사(sono guided core needle biopsy) 1 2예(4.9%)에 비해 5.4배 높은 것으로 나타났다. 초음파 장비의 발달과 입체정위 흡입법(stereotactic vacuum-assisted biopsy)등의 발달로 미세석회화의 조직 학적 진단방법이 다양해지고 있지만, 각각 검사의 특성과 한계점을 고려해 볼 때 X선 유도 하 조직검사(ne edle localized open biopsy)가 유방 미세석회화 병변에서는 정확한 조직학적 진단을 제공한다고 사료된다.
        113.
        2016.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 건강검진을 목적으로 내원하여 경동맥초음파를 실시한 140명을 대상으로 경동맥의 내중막 두께(IMT; intima media thickness)변화 및 죽상경화반(Plaque)의 유무와 혈액학적 검사와의 상호연관성을 알 아보고자 시행되었다. 경동맥초음파상 IMT두께가 1 mm 이상을 비정상으로 간주하고 죽상경화반의 유무를 평가하였으며, 혈청검사를 통하여 지질학적 수치 및 공복혈당수치를 분류하여 상관관계를 알아보았다. 그 결과 공복혈당수치가 죽상경화반을 일으키는 유일한 독립적인 예측인자로 분석되었고(p=0.033), ROC 곡선 분석에서 cut off value는 126 mg/dL(민감도 56.25%, 특이도 68.33%)로 결정되었다. 또한 로지스틱 회귀분석 에서 위험율(Odds ratio)은 1.01배로 나타났다. 따라서 향후 다수의 대상자로 장기적인 전향적연구가 필요할 것으로 사료되며, 혈액검사수치를 고려하여 심뇌혈관질환의 효과적인 일차예방 역할과 혈관의 추적관찰을 위한 경동맥초음파가 적극적으로 권고 된다.
        114.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 술자의 주관적인 판단에 의존하고 있는 질환 여부의 판정을 객관적이고 과학적인 방법으로 판정하기 위한 방안을 제안하였다. 제안된 방법에서는 간세포암 환자를 추적관찰 한 초음파영상을 MSE(Mean Squared Error: 평균제곱오차)를 구한 후 PSNR(Peak Signal to Noise Ratio)분석을 하였다. 분석한 결과 시간이 지남에 따라 MSE값과 PSNR값이 변화함을 알 수 있었다. 이러한 이유는 간세포암이 진행됨에 따라 초음파 에코의 증가로 초음파영상의 변화에 기인하는 것이다. 본 논문의 결과는 술자의 주관적인 판단에 의하여 행해지고 있는 초음파 검사를 과학적이고 객관적인 판정을 할 수 있는 방법으로 활용될 수 있을 것이다.
        115.
        2015.04 KCI 등재 서비스 종료(열람 제한)
        이 논문에서는 의료용 초음파 볼륨 데이터의 잡음을 효과적으로 제거하기 위한 방법을 제안 한다. 초음파 영상은 잡음이 심하여 필터링이 필요하다. 기존의 2차원 필터링은 인접한 슬라이 스 간 정보를 무시하고 기존의 3차원 필터링은 속도가 느리거나 잡음 제거 효과가 떨어지는 필 터를 적용하였고 또한 초음파 데이터의 샘플링 특성을 고려치 않아 균등하게 필터링 하지 않았 다. 이를 해결하기 위해 잡음제거에 효과적인 양방향 필터를 병렬로 빠르게 처리하고 필터 영 역에 따라 윈도우 크기를 달리하는 기법을 제안한다. 공간 필터의 합산영역 테이블을 이용하여 병렬로 빠르게 필터링하고 윈도우 크기는 필터 영역에 따라 비례적으로 결정한다. 실험은 평균 필터와 양방향 필터, 양방향 적응 필터를 적용한 초음파 볼륨 렌더링 영상에서 잡음 제거와 원 본 손실 정도를 비교한다. 이렇게 하여 양방향 필터링을 빠르게 수행하면서 기존 보다 균등하 게 필터링하여 잡음을 효과적으로 정확하게 제거할 수 있다.
        116.
        2015.02 서비스 종료(열람 제한)
        수난 현장의 경우 부유물 등에 의하여 시계가 어두워 인명구조 및 인양에 어려움이 많다. 이에 시계뿐만 아니라, 시계를 대신해줄 수 있는 시스템이 필요로 한다. 최근 해상과 강에서의 사고가 빈번하게 일어나고 있으며, 이런 사고 구조 및 인양에는 잠수부들이 직접 들어가는 경우가 많다. 하지만 열악한 수중 환경으로 인하여 구조 및 인양에 어려움이 있고, 잠수부들의 2차 피해도 발생할 우려가 있다. 이러한 열악한 환경 중, 시계 환경의 열악함으로 잠수부들의 위치인식 불가, 구조물 확인 불가 등의 사유로 수난구조에 있어 중요한 정보들을 잃어버리는 경우가 많다. 현재 세계적으로 이러한 수중환경에서의 시계확보를 위한 초음파 카메라 등의 시스템이 제작 및 시판되고 있지만, 현재 개발 및 시판되는 시스템들은 시스템의 조작 및 이동에 두손이 사용되어져, 잠수부들이 구조 활동 중 구조물의 파악, 생존자의 구조 및 익사자의 인양 등에 사용 되어지는 두 손을 사용할 수 없는 단점이 있다. 이에 본 연구에서는 잠수부가 두 손을 자유롭게 사용할 수 있는 헬멧형 수난 구조탐색시스템을 개발하려고 한다. 헬멧형 수난구조 시스템을 개발함으로써 악조건의 수중환경에서도 시계 확보가 가능해지고, 잠수부들의 구조 활동 시 두 손의 사용이 자유로움으로 인해 구조 활동의 효율성이 오를 것으로 기대된다.
        117.
        2014.09 서비스 종료(열람 제한)
        The patent ductus arteriosus (PDA) is a vascular structure connecting the proximal descending aorta to the roof of the main pulmonary artery, near the origin of the left branch pulmonary artery. Transcatheter closure has become the treatment of choice for most cases of PDA in both children and adults; however, measurement of the exact size and morphology of the shunt in adult cases using only contrast fluoroscopy is difficult. We report on a case of a 49-year-old woman who underwent transcatheter closure of PDA with intravascular ultrasound (IVUS) guideance. In the current case, IVUS is feasible and helpful for measuring the exact size and shape of the PDA.
        118.
        2014.06 서비스 종료(열람 제한)
        May-Thurner syndrome is caused by blockade of local venous flow due to local vascular intimal proliferation, caused by repeated pulsatile compression of the iliac or iliofemoral vein between the iliac artery and the lumbar spine. In this case, we confirmed May-Thurner syndrome using lower extremity computed tomographic angiography and venography. However, on venography, it was impossible to distinguish the left iliac vein from the collateral vein; a thrombus was also seen, although some of the thrombus was not seen clearly. These problems were overcome with use of intravascular ultrasound. We report on intravascular ultrasound guided treatment of May-Thurner syndrome.
        119.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        The Ponciri fructus immaturus (Poncirus trifoliata Rafinesque) has been used in oriental medicine for uterinecontraction, stomachache, abdominal distension and cardiovascular diseases. Two main compounds, poncirin and naringinwere successfully analyzed by high performance liquid chromatography (HPLC) and carried out method validation accordingto ICH guideline. A successful resolution and retention times were obtained with a C18 reversed phase column, at an 1㎖min−¹ flow rate, with a gradient elution of a mixture of methanol, water and acetonitrile. Poncirin and naringin showed goodlinearity (R²>0.999) in relatively wide concentration ranged. The recovery of each compound was 95.81~101.48% withR.S.D. values less than 1.0%. The application of ultrasound-assisted extraction was shown to be more efficient in extractingponcirin and naringin from Ponciri fructus immaturus. The predicted optimal poncirin and naringin yield were poncirin2.15%, naringin 1.65% under an extraction temperature of 40℃, an extraction time of 10 min in a solvent of 70% methanol.
        120.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 콩팥 초음파 검사에서 발견된 콩팥 낭종 증례에서 낭종 내 초음파 간섭에 의한 허상이 진단에 미치는 영향 정도를 공학적 방법으로 해석하는 방안을 제안하였다. 제안된 방법으로 실험한 결과 육안적 방법으로 판단한 방법은 초음파 간섭의 효과로 발생하는 낭종 내의 에코를 구별하지 못하고 간과할 수 있음을 알 수 있었다. 따라서 종괴 내의 미미한 신호의 차이를 본 연구에서 수행한 결과를 이용한다면 오진을 사전에 예방할 수 있을 것이다.
        6 7