검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 571

        83.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wireless sensors are more favorable in measuring structural response compared to conventional sensors in terms of them being easier to use with no issues with cables and them being considerably cheaper. Previous tests have been conducted to analyze the performance of MEMS (Micro Electro Mechanical Systems) sensor in sinusoidal excitation tests. This paper analyzes the performance of in-built MEMS sensors in devices by comparing with an ICP sensor as the reference. Earthquake input amplitude excitation in shaking table tests was done. Results show that MEMS sensors are more accurate in measuring higher input amplitude measurements which range from 100gal to 250gal than at lower input amplitudes which range from 10gal to 50gal. This confirms the results obtained in previous sinusoidal tests. It was also seen that natural frequency results have lower error values which range from 0% to 3.92% in comparison to the response spectra results. This also confirms that in-built MEMS sensors in mobile devices are good at estimating natural frequency of structures. In addition, it was also seen that earthquake input amplitudes with more frequency contents (Gyeongju) had considerably higher error values than Pohang excitation tests which has less frequency contents.
        4,000원
        93.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Micro-Electro-Mechanical Systems (MEMS) sensors have been widely used in Structural Health Monitoring due to their convenience and lower costs in comparison to conventional sensors. Triggered measurements are relevant in events such as earthquakes because unlike continuous measurements, they only record the structural response once an event happens. This is more cost effective and it makes the data more manageable because only the required measurements from the event are recorded. The most common method of triggering is amplitude triggering. However, lower input amplitudes (less than 0.1g) cannot be triggered by using this method. In this paper, sound triggering was introduced to allow triggered measurements for lower input amplitude values. The performance of the sound triggering and amplitude triggering were compared by a series of shaking- table tests. It was seen that sound- triggering method has a wider frequency (0.5~10Hz) and amplitude (0.01~1.0g) range of measurements. In addition, the sound triggering method performs better than the amplitude triggering method at lower amplitudes. The performance of the amplitude triggering, in terms of the triggering being simultaneous improves at higher input amplitudes.
        4,000원
        94.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, measuring instruments for SHM of structures has been developed. In general, the wireless transmission of sensor signals, compared to its wired counterpart, is preferable due to the absence of triboelectric noise and elimination of the requirement of a cumbersome cable. However, the low-cost wireless MEMS sensor has high noise density and transmits the signal wirelessly, so data transmission delay occurs during measurement. Therefore, the footbridges that was previously measured by a mobile phone in 2014 was remeasured using G-Link-200, iPad and iPhone to compare their performance.
        4,000원
        95.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The wavy fins have been widely used in the heat exchangers in coolering system, aerospace system and automotive. Especially, an automobile has the wavy fin and flat tube heat exchanger for oil cooling system. The objective of this research is the performance comparison of wavy fins for battle vehicle diesel engine oil-cooler by numerical analysis. The real type fin is the wavy fin with corrugated structure, and the comparative fin surfaces are plain, louver, lateral perforation and parallel wavy fin. The non-dimensional values of f-factor, j-factor, area goodness factor and volume goodness factor was performed on the performance comparison. The plain and louver fin shows the highest performance in pressure drop and heat transfer respectively. In the area goodness factor and volume goodness factor results, the parallel wavy fin and louver fin show the highest values at each result.
        4,000원
        96.
        2018.12 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        To improve the etch rate of Si3N4 thin film, H2SiF6 is added to increase etching rate by more than two times. SiO3H2 is gradually added to obtain a selectivity of 170: 1 at 600 ppm. Moreover, when SiO3H2 is added, the etching rate of the SiO2 thin film increases in proportion to the radius of the wafer. In Si3N4 thin film, there is no difference in the etching rate according to the position. However, in the SiO2 thin film, the etching rate increases in proportion to the radius. At the center of the wafer, the re-growth phenomenon is confirmed at a specific concentration or above. The difference in etch rates of SiO2 thin films and the reason for regrowth at these positions are interpreted as the result of the flow rate of the chemical solution replaced with fresh solution.
        4,000원
        97.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wireless sensors are more favorable in measuring structural response compared to conventional sensors. This is because they are easier to use with no issues with cables and are considerably cheaper. There are several applications that can be used in recording and analyzing data from MEMS sensor installed on an iPhone. The Vibration App is one of the applications used and there has not been adequate research conducted in analyzing the performance of this App. This paper analyzed the performance of the Vibration App by comparing it with the performance of an ICP sensor. Results show that natural frequency results are more accurate (error less than 5%) in comparison to the amplitude results. This means that built- in MEMS sensor in smartphones are good at estimating natural frequency of structures. In addition, it was seen that the results became more accurate at higher frequencies (5.0Hz and 10.0Hz).
        4,200원
        1 2 3 4 5