검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 780

        541.
        2019.04 서비스 종료(열람 제한)
        In this study, we analyze the policy related to building safety diagnosis and maintenance management and suggest improvement direction of system for building diagnosis. The US has various test methods and laws and regulations standardized on wide territory, so it is excellent in responding to changes in regulations. In the UK, the technology of the building diagnosis related field is advanced through systematic efforts of diagnosis and maintenance of the building. Therefore, it is necessary to establish and revitalize regulations related to building diagnosis and maintenance management, to revise the laws and regulations of related institutions, and to systematically cultivate manpower through specialized agencies related to diagnosis and maintenance.
        542.
        2019.04 서비스 종료(열람 제한)
        The evaluation for the status and levels of tension acting on a cable supported structure has been a issue due to the structural stability. Each of strands comprising that structures is adopted prestress, the tension level of the strand during the operation is a significant factor for structural integrity of the system. However, a suitable alternative for measurement of tension acting on a strand is not proposed, as well as conservative assessment of cable system is bing adopted in industrial application. Thus, in this paper, a new method is proposed for measurement of tensile forces in a strand using guided waves. This method use a dispersion characteristic of guided waves with variation of stiffness between each of wires. Proposed method is experimentally verified by some experiments using a seven-wire strand.
        543.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 레이노 현상 의심 환자의 정량적 판독 보조 지표의 가능성을 확인하고자 하는 것이다. 레이노 현상 의심 환자 99명에서 가능성 낮음 48명, 중간 16명, 높음 35명을 대상으로 하였다. 검사는 15.2± 0.8°C 얼음물에 10분 간 양 손을 한랭 부하 후 99mTc 370 MBq(10 mCi)를 정맥 주사하였다. 이 후 5분, 10분, 20분 양측 열 손가락의 온도 변화를 측정하였고, 핵의학 판독의의 판독 결과와 온도 변화를 비교하였다. 판독 결과 레이노 현상의 가능성이 낮은 군은 손가락 온도가 32.6±4.9°C로 높게 측정되었고, 가능성이 높은 군은 22.7±6.0°C로 낮게 측정되었다(p<0.05). 결론적으로 레이노 현상 의심 증상에 따라 손가락 온도의 차이가 났음을 확인하였고 이를 통해 손가락 온도의 측정이 레이노 진단의 정량적 보조 지표로서의 가능성이 있음을 확인하였다.
        544.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 CT와 3.0T MRI 기기를 이용하여 간문맥을 묘출하는데 있어서 신호대 잡음비와 대조 도대 잡음비의 정량적인 수치를 비교 분석 하여 최적의 영상장치를 알아보고자 하였다. 2018년 2월부터 2018년 4월까지 C대학교병원에서 CT와 3.0T MRI 간 검사를 시행한 20명의 환자를 대상으로 의료영상저장전 송시스템로 전송된 데이터를 무작위로 선정하였다. 정량적 평가를 위하여 간문맥의 4부위(주문맥, 우문맥, 좌문맥, 중간문맥)의 동일한 관심영역을 선정 후 신호평균값과 표준편차를 측정하여 SNR과 CNR값을 평가 하였다. 평가결과 SNR은 CT에서 우문맥 : 9.18±0.72, 좌문맥 : 9.41±0.84, 중간문맥 : 9.54±0.59, 주문맥 : 9.55±0.75이고 3.0T MRI에서 우문맥 : 22.29±2.03, 좌문맥 : 25.89±3.19, 중간문맥 : 24.39±2.87, 주문맥 : 26.64±2.30으로 측정되었다(p<0.05). CNR은 CT에서 우문맥 : 3.75±0.66, 좌문맥 : 3.44±0.65, 중간문맥 : 3.71 ±0.39, 주문맥 : 3.79±0.68이고 3.0T MRI에서 우문맥 : 9.49±0.65, 좌문맥 : 11.00±01.90, 중간문맥 : 12.70 ±1.75, 주문맥 : 10.01±0.98으로 3.0T MRI가 CT보다 높은 수치로 측정되었다(p<0.05). 결론적으로 4부위의 간문맥을 분석한 결과 SNR과 CNR값이 3.0T MRI에서 높은 것으로 나타났다. 따라서 CT와 3.0T MRI에서 간문맥을 묘출하기 위한 최적의 영상장비는 비전리 방사선을 이용하는 3.0T MRI가 우위로 나타났다.
        545.
        2019.04 KCI 등재 서비스 종료(열람 제한)
        본 연구는 갑상샘 초음파에서 K-TIRADS 분류와 K-TIRADS 분류에 따른 Different risk group의 조합을 이용한 방법이 양성과 악성 결절의 감별진단에 유용한지를 평가하였다. 갑상샘 초음파를 시행한 210명을 대상으로 하였으며, 세침흡인세포검사 결과를 바탕으로 후향적인 분석을 하였다. 갑상샘 결절의 양성과 악성에 따른 K-TIRADS와 Different risk group의 점수체계의 차이 분석은 카이제곱 검정을 하였다. ROC 곡선 분석을 통해 악성 결절의 예측을 위한 K-TIRADS 점수와 Different risk group의 최적 cut off 값을 결정하였다. 양성과 악성 결절 군의 분류에 따른 K-TIRADS와 Different risk group의 차이검증 결과에서 각각 통계적으로 유의한 차이를 보였다(p=.001). ROC 곡선 분석에서 양성과 악성 결절의 예측을 위한 K-TIRADS에 따른 점수분류에서는 AUC 0.786, Cut-off value> 2를 나타내었으며, Different risk group에서는 AUC 0.640, Cut-off value> 2로 결정되었다(p=.001). 갑상샘 초음파에서 결절을 발견했을 때 양성과 악성 갑상샘 결절을 감별하는 데 도움을 주는 K-TIRADS에 따른 분류체계가 Different risk group에 따른 분류체계보다 갑상샘 결절의 감별진단에 도움을 줄 것으로 생각하며 K-TIRADS에 따른 분류체계를 적용하면, 불필요한 세포 검사를 줄일 수 있고, 악성 결절의 조기발견에 도움이 될 것으로 생각된다.
        546.
        2019.03 KCI 등재 서비스 종료(열람 제한)
        This study developed diagnostic system to understand the level of welfare cultural service and infrastructure in rural areas. The applicability was reviewed through the Delphi survey and the sample survey of 60 villages. The diagnostic indicators consist of three areas: the demand area, supply area, and delivery area. The demand area consists of 8 indicators, 25 indicators for welfare services and infrastructure (healthcare, social welfare) and 32 indicators for cultural services and infrastructure (culture, education, leisure sports). The service delivery area was divided into service supply area access and traffic accessibility (public transport use status and rural transport model status) by each indicator. A diagnostic system was applied to 60 villages. Services and infrastructure for rural welfare and culture were supplied more in the Si area than Gun area. The delivery area was easier to access the Gun area than Si area. In the case of traffic access, public transportation was more frequently used in the Si area than Gun area, and the rural transportation model was found to have a relatively large amount in the Gun area compared to Si area. The diagnosis system about services and infrastructure for rural welfare and culture will provide information necessary for establishment and decision making of regional development policy taking into account characteristics of rural areas in the future.
        548.
        2018.12 KCI 등재 서비스 종료(열람 제한)
        본 연구는 병원 및 대학교 등에 설치된 X선 발생장치를 대상으로 진단용 방사선 발생장치의 품질관리 항목을 적용하여 성능 비교를 하여 주기적인 성능관리의 중요성을 인식시켜 성능유지 및 관리에 도움을 주고자 한다. 우선 재현성 및 직선성 실험결과 모든 실험조건에서 합격기준에 부합되었으며 주기적인 정도관리가 부족한 GX-650장치의 경우 재현성 평가의 백분율 오차가 높았으며 직선성 평가에서는 관전압을 100 kVp로 설정 시 0.105로 백분율 오차에서 벗어나게 측정되었다. 또한 관전압 및 관전류의 정확도 평가결과 상대적으로 X선 발생횟수가 낮은 장치에서 백분율 오차가 낮은 것을 알 수 있었다. 반가층 실험은 모든 장치에서 관전압 별 반가층 기준에 모두 포함되었다. 따라서 병원용, 실습용 구분보다는 모든 장치의 정도관리의 중요성을 인식하고 적극적으로 장치의 성능관리를 시행하여 장치를 유지 관리해야 할 것이며 특수의료장비처럼 짧은 주기의 정도관리 제도를 마련해야 할 것으로 사료된다.
        549.
        2018.12 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 국가에서 권고하고 있는 일발촬영 진단참고준위 설정에 사용된 조건을 조사하여 PCXMC v2.0 프로그램을 이용하여 유효선량을 측정하고 생물학적 평가를 해보고자 한다. 그 결과 ICRP 60에서 유효선량은 가장 높은 Pelvis AP는 0.794 mSv 가장 낮은 Chest PA는 0.050 mSv이었다. ICRP 103에서는 남성이 가장 높은 T-Spine AP는 0.733 mSv 가장 낮은 Chest PA는 0.057 mSv, 여성은 가장 높은 T-Spine AP는 0.906 mSv 가장 낮은 Chest PA는 0.052 mSv이었다. 남녀 성인 40세 기준으로 일반 촬영별 유효선량을 평가 해 보았고, 선량한도의 제한을 받지 않는 의료피폭이라도 방사선위해의 확률적 영향을 최소화하기 위해서 선량을 권고량 이하로 유지하여 국민의 의료피폭을 줄이기 위해 노력이 필요할 것으로 사료된다.
        550.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        인공지능에 대한 관심이 높아짐에 따라 의료분야에서도 활발하게 인공지능이 연구되고 있다. 현재 국내에서는 엑스선 촬영, 컴퓨터단층촬영(Computer Tomography), 자기공명영상(Magnetic Resonance Imaging) 등의 의료영상장치에 인공지능이 접목되고 있으며 향후 방사선사 없이 환자의 방사선 영상을 획득 할 수 있는 인공지능을 탑재한 의료기기가 발명 될 것으로 예상된다. 본 연구는 엑스선 촬영에 있어서 환자 위치잡이에 대한 자동화에 대해서 초기 연구를 했다. 위치잡이에 대한 평가를 위해 엑스선 장비와 인체 팬텀을 사용했다. 프로그램은 Visual Studio 2010 MFC로 구현했으며 영상은 1,450 × 1,814 크기로 했다. 픽셀 값을 눈으로 식별 가능한 0 ~ 255 값을 갖는 명암으로 변환하여 모니터에 출력했다. 출력한 영상에 세 픽셀 좌표 값을 통해 각도를 예측하고 각도에 따른 음성안내에 따라 환자가 바른 위치잡이를 하도록 유도하는 절차 알고리즘 프로그램을 개발 했다. 다음 연구에서는 사용자가 좌표의 기준을 인공지능에게 전달하는 것이 아닌 인공지능 스스로 구조물을 파악하여 각도를 계산하는 연구를 진행할 것이다. 향후 위치잡이의 자동화를 통해 촬영부터 위치잡이까지 인공지능이 실시하도록 하는 연구에 도움이 될 것으로 예상된다
        551.
        2018.10 서비스 종료(열람 제한)
        Background : Development of new real-time PCR diagnosis method for simultaneous diagnosis of Cylindrocarpon destructans and Fusarium solani, causative fungi of ginseng root rot disease. C. destructans and F. solani are known to be the major pathogens of ginseng root rot disease. Root rot caused by these pathogens is a disease that is difficult to control because the disease progresses slowly and it is difficult to diagnose early and even when symptoms of plant seeding are present, the disease is already spread in the roots. Diagnostic methods to detect the presence or absence of ginseng roots rot fungi in soil before ginseng cultivation are currently being used as a method for controlling. However, commercialized soil extraction kits and PCR diagnostics have cost, diagnostic time, and single diagnostic problems, and need to develop new diagnostic methods. Methods and Results : Primers and probes in the beta-tubulin 2 gene were designed for species-specific detection. In silico analysis, the detection rate of C. destructans was 100% and the detection rate of F. solani was 95%. The multiplex real time PCR optimization conditions including the internal control were established. The analytical sensitivity using positive samples was 10 copies/㎕ for C. destructans and 10 copies/㎕ for F. solani. As a result of performance comparison test with conventional PCR diagnosis methods, it was confirmed that the developed multiplex real time PCR method has the same or better performance in terms of sensitivity. In the developed soil extraction kit, the extraction time was reduced and the extracted DNA quality was improved, compared to the used soil extraction kit. Conclusion : From the above results, we expect that the developed C. destructans / F. solani multiplex real time PCR diagnosis method and soil extraction kit will be useful for real-time monitoring of ginseng root rot pathogenic fungi in the soil of ginseng cultivation area and diagnosis of suitability of ginseng cultivation area.
        552.
        2018.10 서비스 종료(열람 제한)
        Background : Due to changes in climate and cultivation conditions, the growth monitoring is an essential factor in improving crop productivity. With the recent development of image analysis technology incorporating ICT, it has become possible to constantly monitor the crop growth. As a medicinal crop specialized in Gyeongsangbuk-do, Korea, Cnidium officinale Makino was examined for the possibility of growth diagnosis through image analysis for stable production. Methods and Results : The IP camera was installed at 2.5 m height in experiment field. The RGB image of every 06:00 was captured from July 1 to July 30 and used for analysis. The captured images were analyzed using the image analysis tool, Image J. The greeness was estimated by the average value of the green histogram. The canopy size was determined by the color range (red: 0-255, green: mean value-255, blue: 0-255) and was calculated as the ratio of pixels number of the entire image to those of the selected area. The growth temperature during investigation period was measured by Hobo MX2300. High temperature, excess of 28℃, was compared to stress response such as decrement of canopy size. The greeness and the canopy size are respectively represented by the quadratic function greeness = -0.0722GD2 + 6248.9GD – 1e + 08 (GD, growing day; R2 = 0.46) and canopy size = -0.0462GD2 + 3996.7GD – 9e + 07 (R2 = 0.93). From July 11, it began to exceed the growth limit temperature of 28℃, and the canopy size began to decrease from this period. Between the canopy size (C) and the accumulated temperature exceeding 28℃, there was a negative correlation, C = -0.13ATEC + 56.75 (R2 = 0.87) during the decreasing period. Conclusion : Extraction of color information in Cnidium officinale Makino using RGB image should be preceded by standardized setting, but it is considered to be useful tool for analyzing the change of quantitative characteristics over time. In the future, it is necessary to make a comparative study with the actual growth rate in the image diagnosis.
        553.
        2018.10 서비스 종료(열람 제한)
        Background : It is necessary to develop a diagnostic tool for the precision agriculture according to the change of agriculture environment. In particular, medicinal crops are often cultivated in poor areas such as mountains and valleys, and are susceptible to abnormal climates. Therefore, there is a need for a method that can diagnose the growth easily and with time. We conducted a study to investigate the possibility of remote sensing for 10 species of medicinal crops using unmanned aerial vehicles and multispectral images. Methods and Results : This study was conducted in 0 - 4 times continuously cultivated field with 10 species of medicinal crops (Angelica gigas, A. koreana, A. tenuissiman, A. dahurica, A. acutiloba, A. polymorpha, Ledebouriella seseloides, Lithospermum erythrorhizon, Rhemannia glutinosa). Growth characteristics such as plant height, number of leaves, leaf length, leaf width, stem diamanter and number of stems were investigated between July 10 and July 16. The reflectance map of red (660 ㎚) and NIR (790 ㎚) was obtained using a UAV equipped with a multi-spectral sensor and NDVI [Normalized Difference Vegetation Index] was obtained with a Pix4D mapper. As the number of times of continuos cultivation increased, the growth and NDVI tend to decreased. 6 species of Angelica genus were positively correlated with growth characteristics such as plant height, leaf length, leaf width, and stem diameter and NDVI. Otherwise, there was no significant relationship between growth characteristics and NDVI in Ledebouriella seseloides, Lithospermum erythrorhizon, and Rhemannia glutinosa. This is because the difference in the growth according to time of continuos cultivation was not significant and the canopy structure tended to overlap with the upper and lower leaves. Conclusion : NDVI is widely used as a useful tool for evaluating the canopy productivity and is highly correlated with the above-ground growth characteristics of 6 species of Angelica spp. It is necessary to develop the growth index suitable for the each species and to enhance the validity of growth index by examining the correlation under various cultivation conditions.
        554.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 유방 전단파 탄성 초음파에서 탄성도 점수와 변형비를 이용한 방법이 양성과 악성병변의 감별진단에 유용한지를 평가하였다. 탄성 초음파를 시행한 224명을 대상으로 하였으며, 유방조직검사 결과를 바탕으로 후향적인 분석을 하였다. 유방 종괴의 양성과 악성에 따른 5단계의 탄성도 점수와의 동질성 비교는 Fisher's Exact test, 변형비와의 차이검증은 Mann-Whitney U test를 실시하였다. ROC 곡선분석을 통해 악성병변의 예측을 위한 탄성도 점수와 변형비의 최적 cut off 값을 결정하였다. 양성과 악성 결절 군의 분류에 따른 탄성도 점수의 동질성 비교와 변형비의 차이검증 결과에서 각각 통계적으로 유의한 차이를 보였으며(p=.000), ROC 곡선분석에서 양성과 악성 결절의 예측을 위한 탄성도 점수와 변형비의 AUC 0.824, 0.806, cut off 값 3, 4.4로 결정되었다(p=.001). 따라서 탄성도 점수와 변형비는 유방 종괴의 감별진단에 도움을 줄 수 있을 것이다.
        555.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        방사선사는 일반촬영 시에 다양한 환자를 만나게 된다. 노령환자, 유아 등 몸이 불편한 환자를 검사하게 된다. 소규모의 병·의원에는 방사선사가 혼자 업무를 보는 경우가 자주 발생한다. 이러한 경우 방사선사의 두 손은 환자의 자세를 유지하는데 사용되어지기 때문에 촬영에 있어서 어려움을 느끼게 된다. 본 연구는 이러한 문제점을 극복하고자 진단용 방사선 발생 발판 스위치를 고안하여 실험하였다. 제작한 발판 스위치를 진단용 엑스선 촬영장치에 장착하여 조사선량 재현성 시험, kVp, mAs, 백분율평균오차와 같은 정량적 평가를 실시하였다. 결과적으로 발판 스위치 사용에 대한 정량적 평가는 조사선량 재현성 시험에서 변동계수가 0.05이하로 측정되었고 kVp 시험에서는 백분율 평균오차가 ± 10% 이내로 측정되었다. mAs 시험에서도 백분율 평균오차가 ± 20% 이내로 측정되었다. 이는 진단용 방사선 발생장치의 검사기준 범위에 모두 부합하여 사용상 문제점은 제시되지 않았다. 또한 현재 근무 중인 방사선사를 상대로 유용성에 관한 정성적 평가를 실시하였다. 결론적으로 발판스위치의 엑스선 발생효율의 정량적 평가에서는 실험된 검사가 엑스선 발생장치 장비 기준 범위에 부합하였으며 설문을 통한 평가에서도 먼저 병·의원에서 근무하는 방사선사를 상대로 발판 스위치를 사용한 이후 설문을 통해 발판 스위치에 대한 편리성과 활용성에 대해 설문 실시한 결과는 발판스위치 사용은 임상에서 많은 도움을 줄 수 있는 긍정적인 결과로 나타내었다. 그러므로 진단용 엑스선 촬영용 발판 스위치를 사용하면 방사선 기술자 작업의 신속성과 정확성을 효과적으로 향상 시킬 수 있으므로 의료 서비스 만족도를 높이는 데 효과적으로 사용할 수 있을 것이다.
        556.
        2018.10 서비스 종료(열람 제한)
        This paper presents statistics that evaluate the results of a precision safety inspection and precision safety diagnosis over the past five years. The impact and degree of poor inspection and diagnosis were analyzed by dividing contract amount by rate, implementer, and managing body. The purpose of the analysis is to elicit problems and measures in the system.
        557.
        2018.10 서비스 종료(열람 제한)
        The number of deteriorated buildings is increasing every year, and the number of accidents is increasing due to the lack of timely diagnosis, maintenance, and reinforcement. The number of specialized institutions that can diagnose this is limited compared to the number of deteriorated buildings, and a lot of time and resources are invested in the absence of advanced diagnostic techniques based on the evaluation factors of deteriorated buildings. Therefore, it is necessary to build an improved building diagnosis platform by examining the reliability of existing diagnostic evaluation factors for accurate and rapid building diagnosis.
        558.
        2018.10 서비스 종료(열람 제한)
        In this study, a magnetic flux leakage (MFL) method that is known as a suitable non-destructive evaluation (NDE) method for continuum ferromagnetic members was applied to detect the various types of local damages of the steel wire ropes. 3types of artificial damages, such as cutting, corrosion and compression, were formed on wire rope specimen. A multi-channel MFL sensor head that can maintain the constant lift-off was fabricated to scan the wire rope specimen. The fabricated MFL sensor head measured the magnetic flux signals from the three types of damaged specimens. The capability of damage detection according to damage type was verified from the measured MFL signals from each type of damage. And, the characteristics of the MFL signals were compared and analyzed by type of damage.
        559.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        최근 시설물의 안전 및 유지관리에 관심이 증대되고 있으나, 발주처의 저가발주로 인해 안전진단전문기관은 부실화 되고 부실 점검 및 진단으로 인한 많은 문제점들이 야기되고 있다. 따라서 본 연구에서는 실무자들의 인식조사와 사례분석을 통해 실행대가 현황을 고찰하 였으며, 그 결과 정밀안전점검은 대가기준 조정보다는 대가기준의 효율성 증대 및 강제성 강화가 필요한 것으로 판단된다. 또한 정밀안전진단은 연면적 10,000㎡미만 시설물에 대한 대가기준 설계금액을 현재 기준에서 80%로 하향조정하고, 그 이상의 시설물에 대해서는 현행 대가기준을 적용하되, 대가기준의 강제성 강화가 필요할 것으로 판단된다.
        560.
        2018.06 KCI 등재 서비스 종료(열람 제한)
        In this research, the target process was a modified type of a conventional aeration tank with four different influent feeding points and alternated aeration to obtain nitrogen removal. For more accurate switching of influent feeding, the process was operated under a designed control strategy based on monitoring of NH4-N and NOX-N concentrations in the tank. However, the strategy did have some limitations. For example, it was not sensitive to detecting the end of each reaction when losing the balance between nitrification and denitrification of each opposite part of biological tank. To overcome the limitations of the existing control strategy, a diagnosis-based control strategy was suggested in this research using the diagnosis results classified as normal (N), ammonia accumulation (AA) and nitrate accumulation (NA). Using the pre-designed rules for control actions, the aeration and volume of the aerated part of the reactor could be increased or decreased at a fixed mode time. In simulations of the suggested diagnosis-based control strategy, the NH4-N and NOX-N removal rates in the reactor were maintained at higher levels than those of the existing control strategy.