검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 317

        143.
        2013.04 구독 인증기관 무료, 개인회원 유료
        Cultural assets of the country's history and cherish the living conditions of the people, conscious and cohesive crystals, and the pride of the hearts of the people as a haven. In the country worth preserving national treasure, bomulgeup, local cultural heritage as a major cultural property protection are. Cultural properties, etc. Most are wooden, is vulnerable to fire, and, moreover battling to far away from the city and due to the geographical conditions are very challenging aspects. The national cultural assets, such as the many temples, vows to fire one if the loss of a centuries-old cultural property is a big loss of national posterity to great shame is not. Still cultural assets and a large number of visitors have flocked temples. All of us to keep the look and feel of the cultural assets pleasure to conserve cultural assets preserved to ensure that fire prevention is always unmistakably bear in mind that sees.
        4,900원
        144.
        2013.04 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 인천광역시의 37개 사업장(공장)을 대상으로 작업현장의 소음을 측정 및 분석하여 소음이 화재경보음 인지에 미치는 영향을 분석하였다. 측정결과 평균소음이 95.8dB(A)나왔다. 이는 국내 경보장치 음량기준(화재경보음 발생장치에서 1m떨어진 곳에서 90dB이상)보다 5.8dB(A)높게 나왔다. 미국방화협회(NFPA)에 따르면 암소음(기기음)이 85dB(A)이거나 이상일 경우 화재경보음 인지정도가 미흡하기 때문에 다른 방법을 강구하도록 되어 있다. 또한 화재경보음은 암소음보다 15dB(A) 높아야 한다고 하고 있다. 따라서 주변의 환경을 무시한 획일적인 화재경보음 설계에 대해서 제도적 및 법적 개선이 필요하다고 사료된다.
        4,300원
        147.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently buildings are constructed in larger and higher scales and becoming more complex. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. On this study, the permissible evacuation times were estimated for smoke fall, temperature, CO concentration, viability, etc. Fire safety management plans for fire safety were suggested.
        4,000원
        148.
        2012.11 구독 인증기관 무료, 개인회원 유료
        본 연구는 소방대원의 화재진압 업무를 인간공학적 평가도구(RULA, REBA)를 이용 하여 분석하고 타업종(병원, 자동차업종)과의 비교를 수행하였다. 첫째, 소방대원들의 업무 중 화재진압 업무의 인간공학적 작업자세 분석 및 평가하여 극단적인 작업자세에 대해서 살펴보았다. 요구조자 1인 운반법은 RULA, REBA의 평가 결과에서 모두 정밀조사가 필요하고 즉시 개선․조치가 요구되는 4단계로 평가되었다. 둘째, 화재진압 업무와 타업종과(병원, 자동차업종)의 분석 결과를 비교 분석을 실시 하였다. RULA로 평가한 결과 3, 4단계가 차지하는 비율이 72%로 자동차 업종(74%) 에서의 평가결과 보다 낮게 나타났지만 병원업종(37%)보다는 높게 나타났다. REBA로 평가한 결과 3, 4단계가 차지하는 비율이 36%로 병원(9%)과 자동차 업종(24%)에서의 평가결과보다 높게 평가된 것으로 나타났다.
        4,000원
        150.
        2012.11 구독 인증기관 무료, 개인회원 유료
        Or maybe moving dangerous goods tanks of motorists excluded from the scope of the supervision of the fire department and fire prevention education as a blind spot on the part of a large party evidence of markers of contamination loading of dangerous goods according to the type of education that can be handled only by preparing the institutional arrangements accident is blocking the moving path of Dangerous Goods moving tanks and loading dangerous goods on fire budget move the path that corresponds to the report received by securing the extinguishing agent is required to neutralize the ash and fire suppression and repression through skills training from large disasters in advance blocking devices should prepare that will
        4,000원
        151.
        2012.11 구독 인증기관 무료, 개인회원 유료
        Recently buildings are constructed in larger and higher scales and becoming more complex. Every country in the world is competing to build high-rise buildings. Korea also has and is constructing high-rise buildings, like the 123story Jamsil Lotte Super Tower. However from small to large scale buildings and on construction sites there still are fire safety accidents that occur continuously. Therefore to improve fire safety plan, examining the actual fire safety management and understanding fire risk analysis Using Fire Modeling through Computer Simulation. Fire safety management plan related fire safety cases were collected an dan analyzed for the study. Also hazard analysis of High rise Buildings under fire compared with existing fire law sand regulations.
        4,000원
        153.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, FDS fire simulation experiments and measured wind speed by applying the exterior installation portion for blocking the spread of the fire was investigated. As a result, aluminum composite panels installed in the lower and the upper part of the panel to remove all the lower side, and then the maximum wind speed 0.24 m/s and the upper side 0.58 m/s were measured. In the FDS, the measured wind speed difference air currents are approximately 3.7 times in 12 seconds, the occurrence of 17 seconds early moment wind 2.2 m/s was measured from. Before and after the fire occurred in early of the air velocity about 39 seconds was 3.5 times difference. Such air currents caused by the temperature of the building but also by the building height was found. Turbulent flame of fire by expanding the vertical extent of damage become greatly important factor. Therefore, through the exterior installation portion of the block that can delay the spread of fire is expected that this should be taken.
        4,000원
        154.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was performed to test the combustive properties of the pipe insulation materials which are mainly used in the industries and buildings. Fire characteristic test of pipe insulation film according to the KS F ISO 5660-1 was performed. The experimental materials commonly used in the pipe insulation were used four kinds of films. Two kinds of 4 types of products that have the flame retardant performance and the other two types of them have no flame retardant performance. They were selected for fire characteristic test. The result of finding 25kW/m2 radiation from the ignition was that flame retardant products were 140sec and the other one were 69sec in average of heat release rate(HRR). The result of flame retardant products in the 50kW/m2 was 34sec and the other one were 15sec in average of HRR. However, the HRR of flame retardant products was much higher than the other one. Flame propagation test was conducted according to the KOFEIS 1001. The result of flame retardant products was that flame retardant products had a hold without fire spread after firing them. But the other one were completely fired after firing them. Therefore, I want to recommend that flame retardant products need to be used by the regulation to prevent or decrease a fire spread.
        4,000원
        155.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research has set upthe fire fighting general index for Fire fighting of Crowded Wooden Building Cultural Asset which is composed of traditional wooden building instinct or complex. The results of this study are as follows. First, Fire fighting general index for crowded wooden building cultural asset, it is necessary to set fire fighting priority by considering fire risk and cultural asset characteristic and establish the system to cope with fire disaster in the most effective way by arranging facilities with restricted resource. Second. Fire risk is the index to draw fire and spread risk of cultural asset by applying index calculation processes such as fire load, burning velocity and ignition material spread characteristic to various aspects such as individual building and complex and combining their results. Cultural asset importance index consists of individual building evaluation, publicity security degree, area importance evaluation and historical landscape degree evaluation. Third, for each index combination process, weight of each index is drawn on the basis of AHP analysis result that is performed to the specialists of related fields. The formula to apply and combine it is prepared to apply the model to include meaning of each index and comparative importance degree.
        4,900원
        158.
        2012.04 구독 인증기관 무료, 개인회원 유료
        Fire scene is mostly destroyed by the flames but fire fighter's fire suppression and rescue activities also destroys a substantail portion. Structures and furnitures which has already become weaken can be easily damaged. Or when structures built up by moving to another location, it's very hard to restore the original state. Also if it is restored, the object has no evidence that it has existed. In all scenes, the scene can't be preserved when quick extinguishment, rescue activities and preventation of fire spread is needed. On this paper, it reviewed the notes about the possibility of field damage by fire suppression and rescue squad's activities. Also it has reviewed the notes how to minimize the field damage by putting out fires and rescue activities by observing the precautions. The reviewed information will help to make guidelines for preserving the scene. By this, it is expected to make a field study exactly by collecting more valid evidence.
        4,000원
        160.
        2011.11 구독 인증기관 무료, 개인회원 유료
        Development of the economy and the growing income of people interested in the leisure and health has been focused. Past the town common wells and groundwater around the water, but health is a priority these days to solve the drinking water directly from tap water, but most people work from home, through the water purifier has been resolved. Depending on seasonal changes and personal taste of coffee, if you can enjoy a snack and water purifier is a restaurant, lounge, public areas and focusing on the rapid spread of the fire, water purifier as compared to the total number of fires increased by 0.03% per year trend on, but the washrooms fire and fire-related research data and case studies with analysis of the exact cause lack of proper preventive measures are insufficient reality. In this study, focusing on electrical energy using a water cooler to understand the structure and principles of fire, the fire revealed the mechanism is vulnerable to the consideration of factors, the exact cause of the fire investigation and the Assistant, manufacturing defects, and to contribute to fire prevention review should.
        6,400원