검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 164

        21.
        2022.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fungi are organisms that must be monitored and controlled in order to preserve valuable paper records. They reduce the quality of paper records by degradation and/or discoloration. As an effort to understand fungal contamination in the National Archives of Korea, the concentration of fungi in the indoor air of the unsterilized record rooms has been reported. However, what species are present in the facilities is not much known. In the present study, we examined the fungi isolated from the National Archives of Korea and found among them that there are fungal species which are newly documented in Korea. They were identified based on morphological properties and nucleotide sequences analysis of the polymerase chain reaction-amplified the internal transcribed spacer region of rDNA, calmodulin gene, and beta-tubulin gene. We report Cladosporium parahalotolerans, Cladosporium subuliforme, Ochroconis mirabilis, Penicillium angulare, and Penicillium fundyense as new instances of fungal species in Korea. Among these five species, P. angulare is known to able to produce cellulase and O. mirabilis as an opportunistic pathogen of human and animals.
        4,000원
        23.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fungi have been known as an irritant or causal agent of asthma. Thus, information on their concentration and diversity in indoor air of asthmatic patient’s houses is valuable for the management of these micro-organisms. The present study was performed to investigate fungal concentration and diversity in indoor air of resident spaces in two adult patient’s houses in winter. Air samples were collected in February of 2018 from living rooms and bedrooms of two asthma patients’ houses located in two different places in Incheon city using an impaction method. The average concentrations of airborne fungi did not exceed the 500 CFU/m3 level which is recommended by the Enforcement Managements of the Indoor Air Quality, Ministry of Environment, Korea. A total of four genera and 23 species were identified based on morphological and molecular methods. Aspergillus and Penicillium were two major genera. Aspergillus pseudoglaucus and Penicillium citrinum were commonly found between the two patient’s houses. Among the identified fungi, three species, Aspergillus venenatus, Penicillium jamesonlandense, and Penicillium salami were found to be unrecorded species in Korea. The morphological and molecular characteristics of these three unrecorded species were described. Since these species produce spores well and a lot, they are considered to be a species that needs management. This study provides basic information on the fungi for indoor air quality management in the living spaces of asthma patients in winter in Korea.
        4,000원
        24.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Conversion to modern hydrogen energy is required, and research on liquefied hydrogen cargo containment systems is needed for large-capacity transport and storage. In this study, changes in the mechanical properties of the adhesive required for storage and transport in liquid hydrogen were confirmed. The lap shear test was performed by realizing cryogenic conditions in a small chamber using liquid nitrogen and liquid helium. There was an increase of 11.0% in the -180℃ condition compared to room temperature, and an increase of 1.8% in the -230℃ condition compared to the -180℃ condition was confirmed. In the case of shear strain, it is known that it decreases as the temperature goes down. As a result of the experiment, it was confirmed that the value at room temperature and the value at -180℃ reduced the shear strain by 5.0%, and -230˚ compared to the -180℃ condition. An increase of 1.5% was confirmed in the C condition. In the case of the specimen tested at -230℃, the deformation in the gripper part was larger than in other tests, and it is judged that the maximum shear strength and shear strain were affected. In addition, in this study, there is a limitation in the experiment at -230°C rather than 253°C, which is the boiling point of hydrogen
        4,000원
        25.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Airborne bacteria are expected to float in the mushroom cultivation house, as it is a special environment with high humidity and high temperatures. Their concentration and diversity in the indoor air of the cultivation house could effect the health of farmers and the quality of mushrooms. To examine whether microbiota of airborne bacteria change from year to year, we measured the indoor temperature, humidity, and airborne bacterial concentration from mushroom cultivation houses located in six regions in Korea from 2020 to 2021, and isolated and identified airborne bacteria. The surveyed data were compared and the bacterial diversity of the 1st year and the 2nd year were determined. Based on the average temperature and humidity data surveyed, it can be seen that the temperature and humidity environment in the cultivation houses is such that bacteria can easily reproduce. It was observed that the temperature inside the cultivation houses tends to be higher or lower depending on the season and correlates with the temperature outside the cultivation houses. In the first year survey, 32 species of 20 genera were identified, and in the second year survey, bacteria belonging to 29 species of 22 genera were identified. Among them, the most detected species were all species belonging to the genus Bacillus. There were only three species (Bacillus altitudinis, Brevibacterium frigoritolerans, and Staphylococcus epidermidis) that were continuously isolated in common. Our results showed that the species of floating bacteria greatly vary from year to year even for the same cultivation houses.
        4,000원
        26.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In modern times, where problems due to environmental pollution are continuously occurring, hydrogen is in the spotlight as the energy of the future. Hydrogen is an eco-friendly energy resource that does not even generate CO2, and is actively supporting research to utilize hydrogen energy at the national level. This study is a study on the cryogenic mechanical properties of the elements constituting the cargo hold during the transportation of liquid hydrogen. Among the various components, the evaluation of mechanical properties of the cryogenic adhesive under liquid helium conditions was confirmed. The related contents are summarized as follows. As a result of performing SSRT by curing the adhesive, it was confirmed that tensile strength and maximum strain were increased at cryogenic temperature (-230°C) compared to room temperature (25°C). It was confirmed that the adhesive-hardened specimen showed a brittle fracture mode at both room temperature and cryogenic temperature during tensile. Improvements in this study, such as pores occurring during adhesive curing, the use of standard specimens, and experiments at -253°C, the boiling point of hydrogen, exist, and are planned to be carried out in subsequent studies.
        4,000원
        27.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Hydrogen is one of the main candidates in replacing fossil fuels in the forthcoming years. However, hydrogen technologies must deal with safety aspects due to the specific sub�stance properties. This study aims to provide an overview on the loss of mechanical properties of cryogenic materials, which may lead to serious consequences, such as fires and explosions. The hydrogen embrittlement of cryogenic steels was investigated through slow strain rate tensile tests (SSRTs) and thermal desorption analyses of electrochemically H-charged specimens. As a prior study to confirm mechanical properties under liquid hydrogen conditions, the amount of diffusive hydrogen that causes hydrogen embrittlement was confirmed after charging hydrogen using an electrochemical method for 4 types of steel materials applied as cryogenic materials did. When exposed to the same hydrogen charging conditions, the amount of hydrogen diffused into the 9% nickel steel is the highest compared to the austenitic steel type. It is considered that this is because the diffusion and integration of hydrogen into the interior is easy. It is necessary to analyze the relationship between hydrogen loading and mechanical properties, and this will be carried out in a follow-up study.
        4,000원
        28.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to global warming and environmental pollution, environmental regulations are getting stronger, and the International Maritime Organization announced regulations to reduce CO2 emissions in 2018. In order to respond to this, interest in hydrogen energy is growing, and research on liquid hydrogen is spotlighted for storage and transport of large amounts of hydrogen. Hydrogen reduces in volume to 1/800 when liquefied, but its boiling point is close to absolute zero(-253°C), and hydrogen embrittlement that penetrates other materials and weakens mechanical properties. In this study, the change of mechanical properties under cryogenic conditions (-196 degrees below zero) was confirmed after charging hydrogen into existing cryogenic materials (Stainless steel, High Manganese steel, 9% Nickel steel). In Part I, hydrogen was charged using an electrochemical method and quantitative evaluation was performed. In all four materials, as the changing time increased, the diffusible hydrogen concentration increased. After 24 hours charging, the hydrogen loading of 20 wppm in 9% Ni steel and 15 wppm in high-Mn steel was confirmed. In a follow-up study, we plan to study the effect of hydrogen charging by comparing the results of the mechanical properties test with the above results.
        4,000원
        29.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to the strengthening of domestic and international environmental regulations, the replacement of FRP ships with aluminum ships for small ships is continuously in progress. Domestic aluminum ships are being applied to various types of ships, mainly special ships, passenger ships and fishing ships. Gas metal arc welding(GMAW) is used as a welding method when manufacturing ships using aluminum materials for ships with a thickness of 5mm or more. However, it is carried out manually by the workers in the shipyard, and there is a limit to relying on the skills of the workers. In this study, basic research on high-efficiency tandem welding was performed as a basic study for the application of high-quality automatic welding equipment when working on aluminum ships. In this study, welding deformation according to constraint conditions was comparatively analyzed using tandem welding equipment and cross-sections of welds were evaluated for each experiment.
        4,000원
        32.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order for records to be preserved for a long time without physical and chemical transformation, the preservation environment of the library is very important, and environmental problems must be improved through periodic investigation on the preservation environment. Against this background, this study derived fine dust (PM10) and ultrafine dust (PM2.5) concentration data for the libraries, hallways, and workrooms of the National Archives of Korea over two years. There was a difference in the concentration of fine dust and ultrafine dust among facilities, and there was a change in the concentration depending on the month. Both fine dust and ultrafine dust concentrations were present at less than 10 μg/m³ in the libraries. In the hallways, both fine and ultrafine dust concentrations were highest in July. In the workplaces, the monthly fluctuations in the concentration of fine dust and ultrafine dust were large. And the concentration of fine dust and ultrafine dust in the workplaces were higher than those in the library and hallways. Overall, the concentration of fine dust and ultra-fine dust was measured below the maintenance standards stipulated by the Indoor Air Quality Management Act of the Ministry of Environment of Korea in all the investigated facilities. The results of this study are expected to be used as fundamental information to manage the indoor air quality of the facilities of the National Archives.
        4,000원
        33.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Temperature, humidity, and fungal concentration were investigated during the period from May 2019 to August 2021 to obtain information on the indoor air quality in the facilities of the National Archive of Koea, located at Seongnam, Daejeon, and Busan, respectively. The temperature and humidity of the undisinfected libraries was properly maintained for the preservation of papepr records. The airborne fungal concentration differed among the libraries, changed according to the season, and increased especially between June and August. Similarily, the concentration of airborne fungi in the hallways adjacent to the libraries also fluctuated depending on the season and showed a tendency to rise in the months when the ourside temperature rose. In general, the concentration of airborne fungi in the hallways was somewhat higher than that of the libraries. Importantly, it was identified that the concentration of airborne fungi exceeded the recommended standard (500 CFU/m3) by the Ministry of Environment of Korea only in the workroom where the classification and condition inspection of undisinfected records imported from outside were performed. Investigation of airborne fungal concentration from May 2021 to August 2021 showed that the 24 undisinfected libraries in Seongnam, Daejeon, and Busan were all good at 100 CFU/m3 or less. The results of this study are expected to be used as basic data to manage the indoor environment of facilities in the National Archives.
        4,000원
        34.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was undertaken to investigate whether HEPA filter-equipped air purifiers can remove aerosolized virus, whether the removed virus can re-scatter through the filter, and how long the removed virus keeps its infectivity in the filter. For this investigation, six HEPA filter-equipped air purifiers produced by different companies were tested against PhiX174 and MS2 phages aerosolized by nebulizers. For viral detection from the air, LB agar plates covered with Escherichia coli hosts and an Andersen air sampler were used, and from the surface, the swab method was used. Both the aerosolized PhiX174 and MS2 viruses absorbed by the HEPA filters in the air purifiers were not detected from the air through filters or the surface of the outlet of the air purifiers. During the operation of the air purifiers at medium mode, the infectious viral concentration of these viruses in the HEPA filters decreased to 0%~12.3% as the time period passed. These results regarding infectious viral concentration differences were assumed to be due to the different wind speed and air volume among the six air purifiers. Based on observations over 5 days, the infectious viral concentration of the PhiX174 phage was 8,600 times lower when the air purifier was operated than when it was not operated. Overall, our results demonstrate that HEPA filter-equipped air purifiers can efficiently remove the two aerosolized viruses and the removed viruses in the HEPA filter could not re-spread and maintain their infectivity.
        4,000원
        35.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To obtain information on the indoor air quality of un-disinfected libraries used for paper records preservation, temperature, humidity, and bacterial concentration and species were investigated at five un-disinfected libraries from May to September in 2019 in the National Archives, Seoul (Nara Repository), Korea. Temperature and humidity of all the five un-disinfected libraries were well maintained at 18-22oC and 40-55% in compliance with the National Archives Paper Records Preservation Environment Standard. Bacterial concentration ranged from 2 CFU/m3 up to 280 CFU/m3 which were lower than the Korean indoor air quality standard value. A total of 68 bacterial species belonging to 33 genera were identified from indoor air of the five un-disinfected libraries. Among the 33 genera, Bacillus, Micrococcus, and Staphylococcus were the major genera. Only Micrococcus yunnanensis, Roseomonas mucosa, and Moraxella osloensis were commonly found among the five un-disinfected libraries. Bacterial species producing colonies with color on TSA media were present. Among the 68 species, Bacillus circulans and B. megaterium known to produce cellulases were found. There were also 17 species which have harmful effect on human health. The results of this study indicate that continuous monitoring of air borne bacteria is necessary in the un-disinfected libraries used for paper records preservation.
        4,200원
        36.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Mold is one of the harmful biological pollutants in the indoor environment. To investigate how the contamination degree of mold existing in the indoor environment differs according to the characteristics of the house, the concentration of mold in the indoor air was investigated for the houses damaged by leakage or flooding. As a result of a survey of 20 houses located in Gyeonggi-do and Chungcheong-do, the concentration of mold in indoor air surprisingly exceeded more than two times the recommended indoor air quality standard of 500 CFU/m3 in all the houses investigated. The fungal concentration was high in houses with condensation and mold odors. As for the housing type, the pollution degree was higher in detached houses than in row houses. As for the type of water damage, mold contamination was higher in the leaky houses than in the flooded houses. The degree of mold concentration was 1,237 CFU/ m3 in the leaky houses. In terms of housing age, pollution was very high in houses over 20 years old. The occurrence of these measured mold concentrations was correlated at a significant level with respect to the properties of the house. This study shows that in the case of water damaged houses, careful management of mold contamination is required.
        4,000원
        39.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2016년과 2017년 서천, 장흥, 부여, 여주에 소재하는 표고 재배사에서 진균성 병원균을 모니터링 하는 과정에서 Acrodontium crateriforme, Naganishia friedmannii, Pestalotiopsis trachicarpicola, Penicillium wollemiicola, Trichoderma thailandicum 등 5 종의 국내 미기록 진균을 재배사내 실내 공기, 버섯 파리, 버섯 배지재료 등에서 분리하였다. 이들 진균은 PDA 배양하여 생장시키면서 형태적 특성 조사하고 26S rDNA, 28S rDNA, β-TUB 유전자, TEF 유전자 등을 PCR 기술로 증폭하고 그 염기서열 분석을 수행하여 동정하였다. 본 논문에서는 이들의 분류학적 위치와 위해성에 대해 보고하고자 한다.
        4,000원
        40.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Asthma is a chronic diseases that restricts the air passage ways and which is thought to be caused by several factors such as genetics, obesity, mVOC, air pollution, allergens, and fungi. Domestic information on fungi in the indoor air in the houses of asthma patients in the spring and fall is rarely available. Thus, this study was carried out to investigate fungal concentration and diversity. Air samples were collected from the houses of 6 asthma patient in April and October of 2017 located in Seoul and Gyeonggi Provinces using an impaction method. The average concentrations of suspended fungi in the indoor air at the houses of adult asthma patient in October exceeded the 500 CFU/m3 level recommended by the Enforcement Managements of the Indoor Air Quality Control Act. A total of 70 fungi were isolated and identified. Four genera and 11 species were from the April sampling and 10 genera and 27 species were from the October sampling. Among the identified fungi, five species, Arthrinium marii, Penicillium austrosinicum, Penicillium concavorugulosum, Penicillium exsudans and Penicillium johnkrugii were found to be unrecorded species in Korea. The known properties of all identified fungi and the morphological and molecular characteristics of the five unrecorded species were described.
        4,000원
        1 2 3 4 5