검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 351

        261.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        Trains have been a major means of transport in Korea during these past decades. However, train facilities such as stations and repair shops are contaminated with organic and inorganic substances. There is a high probability of train facility contamination with polyaromatic hydrocarbons (PAHs). This study evaluated the PAH and heavy metal contamination of soil near railroads in the Kyungpook area. A total of 18 soil samples were collected from the railroads and analyzed for 16 PAHs and 6 heavy metal species. The contamination level of the top soil was found to be slightly higher than that of the subsoil for contamination with PAHs. The ratio of carcinogenic PAH concentration to the total PAH concentration was relatively high, with a maximum of 0.9. The toxicity equivalent (TEQ) of the PAHs were 500.6 ng/kg in the topsoil and 355.5 ng/kg in the subsoil. The ratio of low molecular PAHs (LPAHs) to high molecular PAHs (LPAHs) ranged from 6.7 to 29.5; this shows that contamination is primarily due to combustion of fuel rather than due to petroleum. The ratio of phenanthrene to anthracene and the ratio of fluoranthene to pyrene also show that contamination occurred due to combustion for transportation. The heavy metal contamination level was lower than the Korean standard, but higher than the background concentration; this indicates that the soil was affected by the operation of the railways.
        262.
        2018.10 KCI 등재 서비스 종료(열람 제한)
        Biomass-fired power plants produce electricity and heat by burning biomass in a boiler. However, one of the most serious problems faced by these plants is severe corrosion. In biomass boilers, corrosion comes from burnt fuels containing alkali, chlorine, and other corrosive substances, causing boiler tube failures, leakages, and shorter lifetimes. To mitigate the problem, various approaches implying the use of additives have been proposed; for example, ammonium sulfate is added to convert the alkali chlorides (mainly KCl) into the less corrosive alkali sulfates. Among these approaches, the high temperature corrosion prevention technology based on ammonium sulfate has few power plants being applied to domestic power plants. This study presents the results obtained during the co-combustion of wood chips and waste in a circulating fluidized bed boiler. The aim was to investigate the characteristics of pollution load in domestic biomass power plants with ammonium sulfate injection. By injecting the ammonium sulfate, the KCl content decreased from 68.9 to 5 ppm and the NOx were reduced by 18.5 ppm, but SO2 and HCl were increased by 93.3 and 68 ppm, respectively.
        263.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        In this study, heavy metal levels at the sediment monitoring network site upstream of the Gangjeong-Goryeong weir in the Nakdong River were surveyed from 2012 to 2016. We assessed the sediment pollution level using various pollution indexes based on ICP-MS analysis. The stream sediment pollution assessment standard, established through Regulation No. 687 of the National Institute of Environmental Research (2015), pollution load index (PLI), potential ecological risk index (RI), and mean PEL Quotient (mPELQ) were used to evaluate the sediment pollution level. We verified the representativeness of the monitoring point through the distribution of sedimentation and scour behavior by river bed surveying using anacousticDopplercurrentprofiler.
        264.
        2016.11 KCI 등재 서비스 종료(열람 제한)
        This study was performed to analyze the effects of a water circulation green area plan on non-point source pollution in Gimhae South Korea. A quantitative analysis of Arc-GIS data was conducted by applying a watershed model based on Fortran to investigate the changes to direct runoff and pollution load. Results showed that prior to the implementation of the water circulation green area plan in Gimhae, direct runoff was 444.05 m3/year, total biological oxygen demand (BOD) pollution load was 21,696 kg/year, and total phosphorus (TP) pollution load was 1,743 kg/year. Implementation of the development plan was found to reduce direct runoff by 2.27%, BOD pollution load by 1.16% and TP pollution load by 0.19% annually. The reduction in direct runoff and non-point source pollution were attributed to improvements in the design of impermeable layers within the city.
        265.
        2016.05 KCI 등재 서비스 종료(열람 제한)
        The adequacy of urban air quality monitoring networks in the largest metropolitan city, Seoul was evaluated using multivariate analysis for SO2, NO2, CO, PM10, and O3. Through cluster analysis for 5 air pollutants concentrations, existing monitoring stations are seen to be clustered mostly by geographical locations of the eight zones in Seoul. And the stations included in the same cluster are redundantly monitoring air pollutants exhibiting similar atmospheric behavior, thus it can be seen that they are being operated inefficiently. Because monitoring stations groups representing redudancy were different depending on measurement items and several pollutants are being measured at the same time in each air monitoring station, it is seemed to be not easy to integrate or transmigrate stations. But it may be proposed as follows : the redundant stations can be integrated or transmigrated based on ozone of which measures are increasing in recent years and alternatively the remaining pollutants other than the pollutant exhibiting similar atmospheric behavior with nearby station’s can be measured. So it is considered to be able to operate air quality monitoring networks effectively and economically in order to improve air quality.
        266.
        2016.04 서비스 종료(열람 제한)
        This research intends to develop a photocatalytic concrete enabling to decompose the nitrogen oxides (NOx) using a titanium oxide photocatalyst for reducing the cost. In details, this research develops the mix composition of the photocatalytic concrete exhibiting photolytic characteristics and establish the technology enabling to reduce the emission of air pollutant caused by nitrogen oxides.
        267.
        2016.02 KCI 등재 서비스 종료(열람 제한)
        In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of 50 m3/day or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, BOD5. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.
        268.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        The purpose of this study was to analyse the runoff characteristics of non-point pollution sources in an urban watershed and determine the effectiveness of newly installed riverwater treatment system to reduce water pollution caused by storm runoff in the urban watershed. The results of this study showed that the levels of BOD5 and suspended solid were highly influenced by first-flush effect and the pollutant load of those two parameters were also very high in the urban watershed. Meanwhile, the effectiveness of riverwater treatment system to reduce the levels of BOD5 and suspended solid was relatively high, but those to reduce the levels of T-N and T-P was low, which needs some additional unit treatment process such as filtration and coagulation. Nonetheless, the riverwater treatment system tested was relatively simple in installation and operation, effective in removing many water pollutants and, most importantly, does not require much space as other treatment systems, so it could be an attractive alternative option to reduce riverwater pollution caused by storm runoff in urban watersheds.
        269.
        2015.09 KCI 등재 서비스 종료(열람 제한)
        The objective of this study was to investigate non-point sources (NPS) pollution and prioritize management areas affected by NPS pollution in the Saemangeum Watershed. AHP (Analytical Hierarchy Process) technique was selected to prioritize sub-watersheds for effectively managing NPS pollution in this study areas. Generation properties of NPS pollution, discharge properties of NPS pollution, and runoff properties of NPS pollution were selected and set for AHP. Weighted descriptors including indicators like numbers of livestock, land- and livestock-system loads, rainfall, and impervious area ratio were generalized from 0 to 1 and multiply each index based on screened 17 survey data. The results were visualized as maps which enable resource managers to identify sub-watersheds for effective improving water quality. The sub-watersheds located in Gongdeok-Myeon, Yongji-Myeon, Hwangsan-Myeon of Gimje-Si were selected for managing NPS pollution control areas. This result presented that these sub-watershed are more affected by the pollution from livestock-system than from land-system. The finding from this study can be used to screen sub-watersheds that need further assessment by managers and decision-makers within the study area.
        270.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        The purposes of this study were to suggest the methodology to select prior areas in the environmental pollution survey for livestock excreta (EPSLE) as well as to elucidate the validity of the methodology. In this study, the prior areas in the EPSLE were determined by examining the number of compost facilities categorized according to the three levels of size including the basin, the sub-basin and the watershed, respectively, based on the data from “Annual Nation-wide Pollution Sources Survey (2012)”. The results suggested that the list of prior basins were Nakdong, Geum, Youngsan and Han river basins in order. Also, it was examined that the prior sub-basins in the four river basins including Nakdong, Geum, Youngsan and Han rivers were Naesung Stream, Geumgang Gongju, Juam Dam and Namhan Downstream, respectively. The prior watersheds in the sub-basins of Naesung stream, Geumgang Gongju, Juam Dam and Namhan Downstream were Seocheon Downstream, Geum Stream, Gyeombaek Suwipyo and Yanghwa Stream, respectively. The validity of the methodology used in this study was elucidated by analyzing the correlation of the number of compost facilities with the concentrations of T-N and T-P observed in the end-points of sub-basins. The results of correlation analysis showed that the concentrations of T-N and T-P increased with the number of compost facilities. Specifically, there was the stronger correlation between the number of compost facilities and the concentrations of T-N than that for T-P. Consequently, it was proved that the methodology used in this work was valid and rational for the selection of prior areas in environmental pollution survey for EPSLE.
        271.
        2015.08 KCI 등재 서비스 종료(열람 제한)
        In order to certificate the distribution and pollution of heavy metal of surface sediments in Nakdong River were collected and analyzed for grain size, water content, ignition loss and heavy metal content. Surface sediments mainly composed of sand(avg. 94.6%) and water content and ignition loss were 20.46%, 1.53% on average. Grain size were relatively fine and organic matter content were relatively high in the Hoichun and Sunakdonggang. Most of heavy metal content(Zn > Cr > Pb > Ni > Cu > Hg) in the Deokcheongang and Sunakdonggang were higher than the other streams. The Igeo were non polluted(less than 0) in all streams and the EF were relatively high in the small stream and PLI were non polluted(less than 1). In addition, organic matter, heavy metal content and pollution were highly correlation with grain size. Surface sediments in study area, heavy metal pollution of the Sunakdonggang were relatively high compared to the other stream but these results were not serious pollution that exceed the sediment pollution evaluation standard of river and lake in Korea and pollution levels adversely affected the majority of benthos were not.
        272.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        The relationship between urban spatial structures and GHG-AP integrated emissions was investigated by statistically analyzing those from 25 administrative districts of Seoul. Urban spatial structures, of which data were obtained from Seoul statistics yearbook, were classified into five categories of city development, residence, environment, traffic and economy. They were further classified into 10 components of local area, population, number of households, residential area, forest area, park area, registered vehicles, road area, number of businesses and total local taxes. GHG-AP integrated emissions were estimated based on IPCC(intergovernmental panel on climate change) 2006 guidelines, guideline for government greenhouse inventories, EPA AP-42(compilation of air pollutant emission factors) and preliminary studies. The result of statistical analysis indicated that GHG-AP integrated emissions were significantly correlated with urban spatial structures. The correlation analysis results showed that registered vehicles for GHG (r=0.803, p<0.01), forest area for AP (r=0.996, p<0.01), and park area for AP (r=0.889, p<0.01) were highly significant. From the factor analysis, three groups such as city and traffic categories, economy category and environment category were identified to be the governing factors controlling GHG-AP emissions. The multiple regression analysis also represented that the most influencing factors on GHG-AP emissions were categories of traffic and environment. 25 administrative districts of Seoul were clustered into six groups, of which each has similar characteristics of urban spatial structures and GHG-AP integrated emissions.
        273.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 황룡강 유역에 유역모델 HSPF (Hydrological Simulation Program - Fortran)를 적용하여 기후변화에 따른 오염부하 유출 변화량을 분석하였다. 황룡강 유역을 7개 소유역으로 분할하고 2011년에 관측된 유량, SS, BOD, TN, TP 농도자료를 이용하여 모델 보정 및 검정을 실시하였다. 기후변화에 따른 황룡강 유역의 환경변화를 예측하기 위해 RCP 4.5와 8.5 시나리오를 이용하였으며, 과거 기간 동안의 강우와 기온에 대한 모의치와 관측치간 월별 평균을 비교하여 미래 기상 자료에 대한 편의보정을 수행하였다. 기후변화 시나리오의 기상 자료 분석 결과, 21세기 전반기와 비교하여 중, 후반기에 상대적으로 많은 연강수량과 연평균기온을 보이는 것으로 분석되었다. 기후변화에 따른 황룡강 유역에서의 오염물질 유출량 분석 결과, RCP 4.5 시나리오에서는 2020년대 대비 2080년대에 평균 연간 강우, BOD, TN, TP 유출량이 각각 47%, 24%, 21%, 27% 증가율을 보여 21세기 후반기로 갈수록 연간 오염부하 유출량이 전반적으로 증가하는 것으로 분석되었다. RCP 8.5 시나리오에서는 2020년대 대비 2050년대에 평균 연간 강우, BOD, TN, TP 유출량이 각각 34%, 20%, 20%, 21% 증가율을 보이며 21세기 중반기에 연간 오염부하 유출량이 상대적으로 가장 많이 증가할 것으로 분석되었다. 이는 연강수량 변화와 동일한 패턴의 변화로서 기후변화에 따른 강우량 변화가 오염물질 유출량에 그대로 반영된 결과를 보여준다. 한편, 월별 오염물질 유출량은 RCP 4.5에서는 9월에, RCP 8.5에서는 2월에 상대적으로 크게 증가할 것으로 분석되었다.
        274.
        2015.02 KCI 등재 서비스 종료(열람 제한)
        In this research traditional Buddhist dietary life style was studied as an alternative for both saving water and decreasing water pollution from household. A traditional dietary life style for the Buddhist monks, called Balwoo Gongyang, and its modernized one for citizens, called Dish Gongyang were examined with water use amount, wastewater quality and pollutant loading rate, and were compared with the kitchen wastewater from household. And several types of natural detergent were also examined to compare their effect on the wastewater quality and pollutant loading rate. This research was carried out using the wastewater from Balwoo and Dish Gongyang in J building located in Seoul. Wastewater generation from Balwoo Gongyang that was about 1.0 ℓ/capita/day was very low compare to that from dish washing in normal household(32.6 ℓ/capita/day). In case of Dish Gongyang, water generation was 1.8 times higher than that from Balwoo Gongyang, but it was just 1/19.2 of normal household. When the wastewater quality of Balwoo Gongyang was compared with the kitchen wastewater of normal household, SS was 1/16(15 mg/ℓ), COD was 1/7(22.1 mg/ℓ), BOD was 1/9(24.1 mg/ℓ) and T-N was 1/16(1.7 mg/ℓ). Pollutant loading rate from Balwoo Gongyang was very low, COD 18.0 mg/capita/day, SS 12.3 mg/capita/day and it was 1/290, 1/639 of that from dish washing wastewater from normal household, respectively. Pollutant loading rate from Dish Gongyang was also low 1/13(SS)∼1/144(TN) compared to dish washing wastewater from normal household. As a natural detergent, used water from washing rice showed very low pollutant loading rate. It was concluded that Dish Gongyang that was a modernized and simplified dietary life style of Balwoo Gongyang, was very eco-friendly. Especially when it was combined with natural detergents using by-product from cooking process, its effect on the water pollution was very low.
        275.
        2015.02 KCI 등재 서비스 종료(열람 제한)
        이 논문은 직·간접적으로 연결되어 있는 해양오염관리의 동태적 현상을 파악하고 해양오염 및 관리 유인을 분석하고자 한다. 이 논문에서는 시스템 다이내믹스 분석 기법을 사용하여 해양오염 및 관리에 대한 하위 시스템을 분석하고 시스템 구성요소간의 피드백 루프 (Feedback loop)를 작성하였고, 이를 바탕으로 해양오염관리의 전체적인 인과지도(Casual map)를 작성하였다. 이 논문의 주된 결과는 다음과 같다. 첫째, 기름유출시 초동방제 유인간 시간지연에 따른 피드백 루프 침체에 대한 장비 및 기술개발, 법률적 개정이 필요하다. 둘째, 사회적 갈등으로 발생된 부식공동체 확산방지를 위한 협력체 구성 및 신사업 창출을 통한 생계수단이 마련되어야 한다. 셋째, 기름유출의 해양오염관 리를 단순히 유출된 기름을 제거하는 방제뿐만 아니라 유출로 인한 지역사회 및 국가차원의 사회적 갈등까지 최소화시켜야할 책무도 포함되 어야 한다. 본 연구에서 제시된 해양오염관리 모델을 통해 기존 방제계획, 매뉴얼 및 대응 프로그램의 개선에서 확인할 수 없었던 시간지연 등의 숨은 유인(Hidden cause)을 확인하고, 광의의 방제활동이 더욱 중요해졌음을 인지하여, 이를 해결 할 수 있는 방향을 제시하는데 도움을 줄 수 있을 것이라 판단된다.
        276.
        2015.02 서비스 종료(열람 제한)
        기상청에서 제공하는 강우자료는 현재 ASOS(종관기상관측장비)와 AWS(자동기상관측시스템) 등이 대표적으로 존재하고 다양한 분야에서 이를 활용한 연구·분석이 이루어지고 있다. 특정지점에서의 기상조건을 탐색하기 위한 방법으로는 지역의 기상조건을 대표할 수 있는 관측소의 값을 이용하거나 일련의 내삽(Interpolation)방법을 통해 공간적인 분석이 이루어 질 수 있다. 하지만 이러한 방법으로는 분석을 위해 자료를 개량하고 추측을 통해야 한다는 한계점이 존재한다. 공간에 기반을 둔 분석을 위해 이러한 한계점을 개선하기 위해서는 일정한 규모의 격자자료가 필요할 것이라 판단된다. 기상청에서는 동네예보를 지원하기 위해 RSA(실황분석자료, Real State Analysis)자료를 생산하고 있다. 이는 KLAPS(초단기 기상분석 및 예측시스템) 재분석자료, 합성레이더 강우량, AWS 관측자료를 합성시켜 생산한 자료로써 5km×5km의 공간해상도를 가진 격자자료이다. 본 연구에서는 ASOS와 AWS, RSA 자료에서 제공되는 강우량과 환경부에서 제공되는 대기측정자료를 이용하여 서로 다른 성격의 기상자료에서 제공되는 기상조건의 변화가 대기오염망에는 어떠한 영향을 미치는지에 대해 분석하고자 한다. 이를 통해 지점(Point)자료와 격자(Raster)자료간에 분명한 차이가 존재한다면 산사태 지점, 교통사고 지점 등과 같이 위치 중심의 공간분석에서 비교적 정밀한 결과를 도출하는데 활용될 수 있을 것이라 기대된다.
        277.
        2015.02 서비스 종료(열람 제한)
        도시화의 급격한 변화로 인한 불투수층의 증가는 도시 내의 강우유출수를 아무런 처리 없이 직접 도시 내에 유출되어 홍수, 첨두유량 증가 등의 문제점을 야기 시킨다. 이러한 문제점을 해결하기 위하여 미국, 유럽, 우리나라 등 많은 국가에서 개발 전 자연이 가지고 있던 수문학적 기능을 최대한 유지하면서 개발 후 발생되는 비점오염물질을 효율적으로 관리하는 저영향 개발 기술을 도입하고 있다. 따라서 본 연구에서는 도시지역 물순환 관리 및 비점오염물질 저감에 기여하고자 저류와 침투가 가능한 식생체류지를 개발 및 평가하고자 수행되었다. 본 연구는 식생체류지의 물순환 및 비점오염물질 저감 능력을 평가하기 위하여 공주대학교 내 주차장에 설치된 식생체류지의 모니터링을 수행하였다. 모니터링한 수질시료는 수질오염공정시험법에 준하여 입자상물질, 유기물, 영양물질 및 중금속에 대한 분석을 수행하였다. 또한 첨두유량 발생시간 및 지체시간, 첨두유량 저감 및 물수지를 산정하여 물순환 효과를 분석하였다. 식생체류지 시설의 모니터링은 2013년 11월부터 현재까지 총 11회가 수행되었으며 모니터링 결과, 강우유출수의 발생시간은 식생체류지를 적용하기 전에 비하여 약 40min 지체되는 것으로 나타났다. 또한 첨두유량의 발생 시간은 시설 적용 전에 비하여 약 80min 이후에 발생하는 것으로 분석되었으며, 첨두유량은 약 0.3m3/min 저감되는 것으로 나타났다. 물수지 산정 결과, 시설 내 저류 및 침투되는 양은 90%로 높은 물순환 효과를 나타낸 것으로 분석 되었다. 비점오염물질 저감효율을 산정한 결과, 모든 오염물질에서 90% 이상으로 높은 저감효율을 나타내는 것으로 분석되었다. 이는 여재부에서 일어나는 오염물질 저감 기작이 효과적으로 작용되는 것으로 판단된다.
        278.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        Emissions from aircraft have impacts on the air pollution of airport and the surrounding area. There are methods of emissions calculated as Tier 1, Tier2, Tier 3A and Tier 3B. Thus, this study investigated emissions from aircraft at the Gimhae International Airport using EDMS(Emissions & Dispersion Modeling System) program. Results of estimation from aviation emissions, Tier 3B considering all parts which can occur at the airport has the largest amount emissions. In order to understand the relation between aviation emissions and distribution of ozone concentration over airport area, numerical evaluation were carried out. Although the difference of surface ozone distribution between numerical assessment with and without aviation emissions was little, effects of air pollution at airport area from aviation emissions of NOx and VOCs.
        279.
        2014.10 KCI 등재 서비스 종료(열람 제한)
        본 연구는 밭경지 현장실험을 통해 다양한 초생대 초종을 적용하여 밭의 비점오염저감효과 분석 및 초생대에 적용 가능한 적합한 초종을 선정하고자 하였다. 경북 군위군에 위치한 면적 1,500m2, 경사 5%의 밭경지를 선정하여 시험포를 조성하였으며, 시험포내에는 대조구 1개와 초생대 처리구 6개로 구성된 총 7개의 시험구를 조성하였다. 츄파, 피, 바랭이, 잔디, 톨페스큐, 켄터키블루그라스를 포함하는 6개의 초종을 선정하여 초생대 실험을 수행하였다. 현장실험 결과 대조구 대비 초생대의 유출저감효과는 6.1~77.8%였으며, 비점오염저감효과는 TS의 경우 15.6~90.3%, T-P의 경우 49.9~96.6%, T-N의 경우 6.7~91.1%를 나타내었다. 전체 오염인자 중에 초생대로 인해 전반적으로 높은 비점오염저감 효과를 나타낸 것은 TS, T-P, T-N, SS인 반면, BOD, TOC와 NO3-는 낮은 저감효과를 보였다. 비점오염저감 및 유지관리측면에서 가장 유리한 초생대 초종은 잔디로 평가되었다. 본 연구결과를 통해 우리나라 농촌지역 밭 비점오염저감을 위한 관리기법으로 초생대가 효과적으로 활용가능하리라 사료되며, 보다 장기적이고 다각적인 현장실험을 통해 초생대 현장적용을 위한 설계지침서 개발이 요구된다.
        280.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        The Ministry of Environment (MOE) has made more effort in managing point source pollution rather than in nonpoint source pollution in order to improve water quality of the four major rivers. However, it would be difficult to meet water quality targets solely by managing the point source pollution. As a result of the comprehensive measures established in 2004 under the leadership of the Prime Minister’s Office, a variety of policies such as the designation of control areas to manage nonpoint source pollution are now in place. Various action plans to manage nonpoint source pollution have been implemented in the Soyang-dam watershed as one of the control areas designed in 2007. However, there are no tools to comprehensively assess the effectiveness of the action plans. Therefore, this study would assess the action plans (especially, BMPs) designed to manage Soyang-dam watershed with the WinHSPF and the CE-QUAL-W2. To this end, we simulated the rainfall-runoff and the water quality (SS) of the watershed and the reservoir after conducting model calibration and the model validation. As the results of the calibration for the WinHSPF, the determination coefficient (R2) for the flow (Q, m3/s) was 0.87 and the R2 for the SS was 0.78. As the results of the validation, the former was 0.78 and the latter was 0.67. The results seem to be acceptable. Similarly, the calibration results of the CE-QUAL-W2 showed that the RMSE for the water level was 1.08 and the RMSE for the SS was 1.11. The validation results(RMSE) of the water level was 1.86 and the SS was 1.86. Based on the daily simulation results, the water quality target (turbidity 50 NTU) was not exceeded for 2009∼2011, as results of maximum turbidity in '09, '10, and '11 were 3.1, 2.5, 5.6 NTU, respectively. The maximum turbidity in the years with the maximum, the minimum, and the average of yearly precipitation (1982∼2011) were 15.5, 7.8, and 9.0, respectively, and therefore the water quality target was satisfied. It was discharged high turbidity at Inbuk, Gaa, Naerin, Gwidun, Woogak, Jeongja watershed resulting of the maximum turbidity by sub-basins in 3years(2009∼2011). The results indicated that the water quality target for the nonpoint source pollution management should be changed and management area should be adjusted and reduced.