        21.
        2022.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the demand for appropriate heat dissipation measures to improve product stability and performance continues to increase and product design becomes highly integrated, research to improve heat transfer performance while maintaining the same area or size is required. In this study, the sample-shaped aluminum plate was treated as upper-coating, and the thickness of the coating was divided into 1mm, 2mm, and 3mm, respectively, and the coating material was applied with silver, copper, and graphene. The temperature condition of the heat source was set to 473K, and heat dissipation analysis was performed under natural convection. The thermal performance was compared and analyzed through temperature distribution, flow velocity distribution, and heat flux, and it was confirmed that the high thermal conductivity of graphene compared to other materials had a dominant effect on the increase in the conduction heat transfer rate. And it was confirmed that the high surface temperature of the graphene coating also increased the heat transfer rate by convection, thereby enhancing the heat dissipation effect.
        4,000원
        22.
        2022.05 구독 인증기관·개인회원 무료
        The research for the safe management of high-level waste in Korea has been conducted by the Korea Atomic Energy Research Institute since 1997, and the results have formed the basis of the national basic plan for the high-level waste management and the revised national basic plan. In the future, it is evolving and developing R&D focusing on securing technologies for demonstration of the disposal technologies and R&D to develop disposal concepts that increase safety and improve efficiency. Efficient management of heat generated from high-level radioactive waste, including spent nuclear fuel, is an important factor in establishing the disposal concepts because it must be in harmony with key factors such as repository layout, waste disposal container specifications, and design and operation for the barriers of the disposal system. For safe and complete isolation of highlevel radioactive waste in the deep geology, the disposal systems that meet the thermal requirements for the disposal system design have been developed by harmonizing the thermal characteristics of engineered and natural barriers in Korea. These disposal systems were based on low burn-up spent nuclear fuel characteristics generated in the early stages of nuclear power generation, and next, based on the high-level wastes from recycling process of the high burn-up spent nuclear fuels, and were the direct disposal systems for the high burn-up spent nuclear fuels. So, it is necessary to track and analyze the change process in the decay heat characteristics of the high-level waste to be disposed of in order to improve the disposal concept, which enhances the safety of disposal and the utilization of the national land. Therefore, in this paper, the process of change in decay heat of reference spent nuclear fuels for disposal applied to the disposal concepts from the initial stage of development of high-level waste disposal technology to the present in Korea is analyzed.
        23.
        2022.05 구독 인증기관·개인회원 무료
        The design of the high-level radioactive waste (HLW) repository is made for isolating the HLW from the groundwater system by using artificial and natural barriers. Granite is usually considered to be a great natural barrier for the HLW repository in various countries including Sweden, Canada, and Korea due to its low hydraulic permeability. However, many fractures that can act as conduits for groundwater and radionuclides exist in granite. Furthermore, the decay heat generated by the HLW can induce groundwater acceleration through the fracture. Since the direction, magnitude, and lasting time of the heat-induced groundwater flow can be differed depending on the fracture geometry, the effect of fracture geometry on the groundwater flow around the repository should be carefully analyzed. In this study, groundwater models were conducted with various fracture geometries to quantify the effect of various properties of fractures (or fracture networks) on the heat-induced groundwater flow. In all models, the pressure around the repository only lasted for a short period after it peaked at 0.1 years. In contrast, the temperature lasted for 10,000 years after the disposal inducing the convective groundwater flow. Single fracture models with different orientations were conducted to evaluate the variations in groundwater velocities around the repository depending on the fracture slope. According to the results, the groundwater velocity on the fracture was the fastest when the regional groundwater flow direction and the fracture direction coincided. In double fracture models, various inclined fractures were added to the horizontal fracture. Due to the intersecting, the groundwater flow velocity showed a discontinuous change at the intersecting point. Lastly, the discrete fracture network models were conducted with different fracture densities, length distributions, and orientations. According to the modeling results, the groundwater flow was significantly accelerated when the fracture network density increased, or the average fracture length increased. However, the effect of the fracture orientation was not significant compared to the other two network properties.
        24.
        2022.05 구독 인증기관·개인회원 무료
        Dry storage is a predominantly used method as a spent nuclear fuel storage system after spent nuclear fuel is cooled in the spent fuel pool. Spent nuclear fuel is highly radioactive and it generates heat called decay heat originated by fission products and radiation. Therefore, temperature of spent nuclear fuel should be predicted whether its cladding temperature is maintained under 400°C, which is the allowable temperature limit of cladding in a dry storage. ANSYS Fluent and COBRA-SFS are predominantly used computational method to investigate the temperature of spent nuclear fuels in a dry storage. Herein, thermal analysis results with the methods were compared based on a Single Assembly Heat Transfer Test, which is a heat test with an electrically heated model of a single PWR fuel assembly in a dry cask performed at the Pacific Northwest Laboratory. Decay heat was 1kW and backfill gas was air. Fix temperature boundary condition is applied to inner shell according to measured temperature. In case of peak cladding temperature (PCT), Fluent predicted 240–284°C, while COBRA-SFS gave 243–292°C. The discrepancy between the codes is under 2.5%. The location where PCT took place was 3.65 m from the bottom of the assembly in both results. However, temperature difference between the upper and lower region of the assembly based on the Fluent was smaller than the temperature difference based on the COBRA-SFS. It means the heat was well transferred in an axial direction with Fluent compared to COBRA-SFS. In lower plenum region where air was naturally circulated, COBRASFS had disadvantages compared to Fluent because it modeled the lower plenum by single node, so it was hard to simulate convection heat transfer by natural circulation. natural circulation speed of air in a center region of the assembly was 0.07–0.1 m·s−1 in both cases.
        25.
        2022.05 구독 인증기관·개인회원 무료
        The fabrication of waste forms with high thermal and structural stability is an essential technology for the safe management and disposal of radioactive wastes. In particular, the thermal characteristics of waste forms containing high heat-generating nuclides such as Cs and Sr can be used for the optimized design of the waste form to secure its thermal safety, and they also provide basic design data for the safe management of canisters, storage systems, and repositories. The Korea Atomic Energy Research Institute is actively developing processes and equipment for fabricating various types of high-level wastes into a stable glass or ceramic waste form. In previous research related to the thermal analysis of the waste form, a relatively simple analysis was performed by using the analytic solution of the one-dimensional steady-state heat conduction equation considering the decay heat properties of the waste. As a specific application study, the optimized diameter of the cylindrical glass waste form was proposed by evaluating the centerline temperature of the waste form. In this study, we extended previous research by introducing a more complicated model, and the main results are summarized as follows. First, an analytical solution was derived by applying the temperaturedependent thermal conductivity expressed in the general form of polynomial function to the onedimensional heat conduction problem previously studied. Second, the two-dimensional axisymmetric steady-state heat conduction problem with a more realistic cylinder model with finite length was modeled and solved by using the finite element method via Matlab’s PDE (partial differential equation) toolbox. Third, thermal analysis was performed on the SrTiO3 waste form, selected as a stable form of strontium nuclide, using the developed analytical and numerical methods. The differences in the temperature distribution and computation time were evaluated through a comparative study of both solutions. Although the problem considered in this study could easily be solved by using commercial CFD software such as ANSYS or SolidWorks, a code-based program was developed to facilitate parametric design study in conjunction with optimization algorithms. The analysis results could be used to evaluate the thermal stability of waste form and to optimize the shape and size of the waste form in consideration of the design constraints of storage systems or repositories.
        26.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the powder bed fusion (PBF) process, a 3D shape is formed by the continuous stacking of very fine powder layers using computer-aided design (CAD) modeling data, following which laser irradiation can be used to fuse the layers forming the desired product. In this method, the main process parameters for manufacturing the desired 3D products are laser power, laser speed, powder form, powder size, laminated thickness, and laser diameter. Stainless steel (STS) 316L exhibits excellent strength at high temperatures, and is also corrosion resistant. Due to this, it is widely used in various additive manufacturing processes, and in the production of corrosion-resistant components with complicated shapes. In this study, rectangular specimens have been manufactured using STS 316L powder via the PBF process. Further, the effect of heat treatment at 800 °C on the microstructure and hardness has been investigated.
        4,000원
        27.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Steel deck bridges are the preferred structural type for reducing dead load, and the use of thin-layer asphalt concrete with excellent adhesion to the steel deck and excellent deformation followability is increasing for bridge pavements. However, because these materials are constructed at a high temperature of 240 °C or higher to maintain high fluidity during construction, excessive thermal deformation and stress may be temporarily induced in the steel deck. Therefore, the stability of the structure must be assessed by considering the environmental conditions of the site during pavement construction. Herein, a method is presented for estimating the heat source equation, in which conduction and convection effects are removed using temperature measurement data, for modeling U-rib using plate elements. The validity of the study is assessed by deriving the equivalent heat source equation using the temperature data measured from the underside of the steel deck while constructing a 40-mm-thick goose asphalt concrete pavement layer on a 12-mm-thick steel deck. In addition, the practicality is verified by performing heat transfer and thermal stress analyses. METHODS : By comparing the temperature data measured during the construction of high-fluidity asphalt concrete with the results of repeated heat transfer numerical analysis, heat source data without field conduction and convection conditions are obtained. Subsequently, a heat source equation suitable for the heat source data is derived using the least-squares method. RESULTS : The results of the heat transfer analysis using the equivalent heat source equation calculated using the presented method are almost consistent with the measured temperature data. In addition, the behavioral characteristics of the structure that matches the behavior of the actual structure can be derived through thermal stress analysis, which considers heat conduction and convection to adjacent members. CONCLUSIONS : Even when the steel deck and U-rib member are modeled as plate elements, thermal effect analysis can be performed reasonably while considering field conditions.
        4,000원
        28.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper considers the influence of internal heat exchanger and capillary tube on the efficiency of small refrigeration system using eco-friendly refrigerants such as R290, R600a, R1270, and R717. A refrigeration system using such internal heat exchanger and capillary tube may improve performance, but may degrade performance. Therefore, this paper used a mathematical model in a normal state to understand performance characteristics as to what change occurs when internal heat exchanger and capillary tube are attached to eco-friendly refrigerant based on R134a. In addition, the effects of operating conditions such as refrigerant flow rate, evaporation temperature, condensation temperature, subcooling degree internal heat exchanger length and capillary tube length were analyzed. The result showed that the evaporation temperature, condensation temperature, subcooling degree, internal heat exchanger length and capillary tube length had an effect on the refrigeration capacity and compression power. Therefore, it is necessary to design a refrigeration cycle using an eco-friendly refrigerant by grasping these effects in detail.
        4,000원
        30.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to environmental pollution, regulations on existing petroleum-based fuels are increasing day by day. LNG is in the spotlight as an eco-friendly fuel that does not emit NOx or SOx, but its boiling point is -163°C, so it needs to be handled with care. Materials that can be used at the above temperature are defined by IMO through the IGC Code. Among them, 9% nickel steel has great advantages in yield strength and tensile strength under cryogenic conditions, but it is difficult to use in arc welding such as FCAW for various reasons. This study is a study to apply fiber laser welding to solve this problem. As a previous study, this study conducted a study to find a welding heat source. After performing bead on plate welding, the optimal heat source was derived by analyzing the shape of the bead and adjusting the parameters of the heat source model. In this case, by applying the multi-island genetic algorithm, which is a global optimization algorithm, not the intuition of the researcher, accurate results could be derived in a wide range.
        4,000원
        31.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The enhancement of heat transfer in cooling system of cylindrical lithium-ion battery pack is numerically investigated by installing fins on the cooling plate. Battery Design StudioⓇ software is used for modeling electro-chemical heat generation in the battery and the conjugated heat transfer is analyzed with the commercial package STAR-CCM+. The result shows that installing fins on the cooling plate increases the convective heat transfer on the surface and thus lowers the maximum temperature of the battery pack. As the length and thickness of the fins increase, heat transfer in the battery pack improves. Considering the geometry and airflow of the battery pack, the optimal values for the length and thickness of the fin are both 2mm. As the convective heat transfer coefficient of the surface increases, the maximum temperature of the battery pack is greatly reduced and the temperature gradient is greatly improved.
        4,000원
        32.
        2021.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 하절기 토마토 재배 시 주간 포그 냉방, 야간 히트펌프 냉방을 처리를 하여 냉방 처리가 온실 내 온습도, 작물의 생육 및 수확량에 미치는 영향을 분석하였다. 하절기 주간에 차광 처리한 대조구 온실의 평균 온습도는 32.1°C, 59.4%였고, 포그 처리한 시험구 온실의 평균 온도는 30.0°C, 74.3%로 나타났다. 이 때 외부의 평균 온습도는 31.4°C, 57.7%로 대조구 온실의 온도는 외기보다 0.7°C 높았으나 시험구 온실의 온도는 외기보다 1.4°C, 대조구보다 2.1°C 낮게 나타났다. 평균 습도는 시험구 온실 74.3%, 대조구 온실 59.4%로 포그 처리를 한 시험구에서 높게 나타났다. 야간 대조구 온실의 평균 온습도는 25.2°C, 85.1%였고, 히트펌프로 냉방을 한 시험구 온실의 평균 온습도는 23.4°C, 82.4%, 로 나타났다. 야간 외부의 평균 온습도는 24.4°C, 88.2%로 대조구 온실의 온도는 외기보다 0.8°C 높았으나 시험구 온실의 온도는 외기보다 1.0°C, 대조구보다 1.8°C 낮게 나타났다. 평균 습도는 시험구 온실 82.4%, 대조구 온실 85.1%로 나타나 시험구 온실의 습도가 더 낮게 나타났다. 작물 생육은 정식하고 8주 후에는 두 온실 간의 큰 차이는 없는 것으로 나타났으나 냉방 처리 후에는 시험구 온실의 작물이 대조구에 비해 경경, 초장, SPAD 값이 높게 나타났다. 토마토의 수확량은 냉방을 시작하고 2주 후까지 총 생산량의 차이는 1.2%로 큰 차이 없었으나 3주 후와 4주 후의 일 생산량이 시험구에서 대조구보다 많게 나타났다. 최종적으로는 시험구의 수확량이 81.3kg, 대조구의 수확량이 73.8kg으로 시험구가 대조구에 비해 10.2% 많게 나타남으로써 하절기 주간 포그 냉방, 야간 히트펌프 냉방이 작물 성장에 적합한 환경을 조성해 줌으로써 생육 및 생산성에 영향을 미친 것으로 판단된다. 냉방 처리에 따른 경제성을 비교해보면 대조구 온실에서는 142,166원의 수익이 있었던 반면 시험구 온실에서는 28,727원의 손해가 발생하여 냉방 처리는 경제성이 떨어지는 것으로 나타났다. 그러나 재식 밀도, 히트펌프 운용 시간 및 기간을 조절하여 에너지 사용은 줄이면서 생산성을 증가시킨다면 경제성도 확보할 수 있을 것으로 기대되며 이에 대한 추가 연구가 필요할 것으로 판단 된다.
        4,000원
        33.
        2021.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The multi-layered heat source model is a model that can cover most of existing studies and can be defined with a simple formula. Based on the methodology performed in previous studies, the welding heat source was found through experiments and FEM under the welding power conditions of three cases and the parameters of the welding heat source were analyzed according to the welding power. In this study, parameters of fiber laser welding heat source according to welding power were searched through optimization algorithm and finite element analysis, and the correlation was analyzed. It was confirmed that the concentration of the welding heat source in the 1st layer was high regardless of the welding power, and it was confirmed that the concentration of the welding heat source in the 5th layer (last layer) increased as the welding power increased. This reflects the shape of the weld bead that appears during actual fiber laser welding, and it was confirmed that this study represents the actual phenomenon.
        4,000원
        34.
        2021.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, gas flow pattern and temperature distribution in a laboratory scale low temperature furnace for carbonization were numerically analyzed. The furnace was designed for testing carbonization process of carbon fibers made from polyimide(PI) precursor. Nitrogen gas was used as a working gas and it was treated as an ideal gas. Three-dimensional computational fluid dynamics analysis for steady state turbulent flow was used to analyze flow pattern and temperature field in the furnace. The results showed that more uniform velocity profile and axisymmetric temperature distribution could be obtained by varying mass flow rate at the inlets.
        4,000원
        35.
        2021.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 기상청 현업모델(LDAPS)로부터 예측된 서울의 도시열섬 강도와 지상 기온을 AWS 관측과 비교 평가하였다. 관측된 서울의 열섬 강도는 봄과 겨울동안 증가하며 여름동안 감소한다. 열섬 강도의 시간적 변동 경향은 새벽 시간 최대, 오후에 최소를 보인다. 기상청 국지기상예측시스템(LDAPS)으로부터 예측된 열섬 강도는 여름철 과대모의, 겨울철 과소모의 특징을 보인다. 특히 여름철은 주간에 과대 모의 경향이 증가하며, 겨울은 새벽 시간 과소 모의 오차가 크게 나타난다. LDAPS에서 예측된 지면 기온의 오차는 여름철 감소하며 겨울철 증가한다. 겨울철 열섬 강도의 과소 모의는 도시 기온의 과소 모의와 관련되었으며, 여름철 열섬 강도의 과대 모의는 교외 지역 기온의 과소 모의로부터 기인하는것으로 판단된다. 도시 열섬강도 예측성 개선을 위하여 도시효과를 고려하는 도시캐노피모델을 LDAPS와 결합하여 2017년 여름 기간동안 모의하였다. 도시캐노피모델 적용 후 도시의 지면 기온의 오차는 개선되었다. 특히 오전시간 과소모의되는 기온의 오차 개선 효과가 뚜렷하였다. 도시캐노피모델은 여름동안 과대 모의하는 도시열섬강도를 약화시키는 개선 효과를 보였다.
        4,600원
        36.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study aims to reduce the urban heat island phenomenon via utilization of porous asphalt pavements. METHODS : One of the many known functions of porous asphalt is that it reduces the urban heat island phenomenon. Indoor experiments were conducted to compare the surface temperature of sprinkled dense-graded and porous asphalt and outdoor experiments were conducted to verify the difference between the two asphalt pavements under external conditions. RESULTS : The results of the indoor experiment demonstrated that the temperatures of the two pavements were similar and that the porous asphalt pavement exhibited low temperature when sprinkled; the temperature of the porous asphalt was approximately 2 °C lower than that of the dense-graded asphalt pavement. The results of the outdoor experiment showed that the peak temperatures of the two pavements were approximately the same as usual. However, it was confirmed that the surface temperature of the porous asphalt pavement at night after sunset was lower than that of the dense-graded asphalt pavement and that the peak temperature dropped for approximately 1~2 days after the rainfall.. CONCLUSIONS : Porous asphalt pavement has a lower surface temperature than normal dense-graded asphalt pavement, under the presence of moisture in the pavement. In addition, it was confirmed that the lower surface temperature of the porous asphalt pavement is due to the low heat emission of the pavement at night. Accordingly, it is believed that the application of the porous asphalt pavement will not only have known effects but also significant impacts on the reduction of urban heat island phenomena.
        4,000원
        37.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        While the vehicle has a wide front view, making it easy to recognize obstacles while driving, the rear side has a narrow view and the inconvenience of having to turn its head to check. A side mirror developed to address this discomfort is mounted outside the front door of a passenger car and used to identify rear objects. In this study, heat transfer analysis was performed and analyzed in order to obtain optimal defrost conditions using regression analysis method for removing mirror condensation and frost. As a result of this study, the coefficient of determination, R2, which represents the regression to the total variation through regression analysis, showed a good reliability of 85.3%. Comparing the predicted and interpreted values of the maximum temperature distribution in the regression equation established in this study, it was included in the 95% confidence interval, enabling the prediction of the maximum temperature distribution over the heat conduction time.
        4,000원
        38.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The estimation of heat source model is very important for heat transfer analysis with finite element method. Part I of this study used adaptive simulated annealing which is one of the global optimization algorithm for anticipating the parameters of the Goldak model. Although the analysis with 3D model which depicted the real situation produced the correct answer, that took too much time with moving heat source model based on Fortran and Abaqus. This research suggests the procedure which can reduce time with maintaining quality of analysis. The lead time with 2D model is reduced by 90% comparing that of 3D model, the temperature distribution is similar to each other. That is based on the saturation of heat transfer among the direction of heat source movement. Adaptive simulated annealing with 2D model can be used to estimate more proper heat source model and which could enhance to reduce the resources and time for experiments.
        4,000원
        39.
        2020.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박 및 해양구조물에서 사용하고 있는 고강도 알루미늄 합금들은 스틸과 비교해서 많은 이점을 가지고 있다. 최근 고강도 알루미늄 합금들은 육상 및 해양에 폭넓게 사용되고 있으며, 특히, 특수목적 선박의 선체 외판구조에 많이 이용되고 있고, 교량 구조물에 사용되는 상자 구조물, 그리고 고정식 해양플랫폼의 상부구조에서 소비율이 증가하고 있다. 알루미늄 재료는 스틸보다 1/3의 중량 구성비를 통하여, 구성 중량을 줄이게 하여 연비 절감을 가능하게 한다. 일반적인 강구조물의 응력-변형률 관계와 비교하면, 용접가공에 따라 발생하는 열영향부의 존재로 인하여 상당히 다르게 나타난다. 왜냐하면, 강구조물과 비교하면 열전도율이 높아서, 열영향부(heat affected zone, HAZ)가 남아 있어 구조 강도 저하를 가져온다. 본 논문에서는 MIG(Metal inert gas) 용접 때문에 발생하는 열영향부를 고려하고, 종방향 압축 하중에 대한 알루미늄 보강판의 좌굴 및 최종강도 특성을 분석하였다. MIG 용접에 따른 열영향부를 고려한 경우, 좌굴 및 최종강도 모두 감소하며, 열영향부의 범위가 15 mm부터 항복 이후 에너지 소실률이 크게 나타나며, 25 mm 이상부터는 그 차이가 크지 않다. 따라서, 알루미늄 합금재료를 적용한 보강판의 구조 거동을 파악하기 위해서는 열영향부 영향에 대한 검토 및 분석이 중요하다.
        4,000원
        1 2 3 4 5