검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 195

        41.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fiber-reinforced polymer (FRP) bars have advantages as a construction material, including corrosion resistance, lightweight and high tensile strength. However, FRP rebars have shortcomings, such as low elastic modulus comparing to the steel rebar. With these reasons, FRP bars have not been widely used to reinforced-concrete (RC) structures. To overcome these shortcomings, the steel-hybrid GFRP rebars were developed by the authors at Korea Institute of Civil Engineering and Building Technology (KICT). Mechanical properties of the developed steel-hybrid GFRP rebars were experimentally evaluated through this study. Both tensile and bonding tests were conducted and the mechanical performance was investigated as well as corrosion resistance. As a result of all tests, elastic modulus, tensile strength and boding strength of the steel-hybrid GFRP rebars were all improved in comparison with fully GFRP rebars.
        4,000원
        42.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The proposed hybrid damper installs at a coupling beam and consists of a high-damping rubber (HDR) and steel pin. The proposed hybrid damper adopted a pin-lock system acts as a viscoelastic damper under wind load (small displacement) while it behaves as a hysteretic damper under earthquake load (large displacement). In this paper, the pin-lock mechanism and structural performance of the proposed hybrid damper is evaluated through experiment. Experiments were carried out with the variables which displacement, loading frequency and steel pin quantities were used. Test results showed that the pin-lock mechanism and the performance of the hybrid damper under a large displacement were verified. Also equivalent damping ratios of HDR were increasing at a small displacement as displacement amplitudes were increasing. However HDR did not depend on frequency,
        4,000원
        43.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To overcome the weakness of spread foundation in large space structure, the research of precast pile for replace spread foundation have been conducted. The new type of joint between PHC pile and steel column is named HAT Joint(Hollow hAlf-sphere cast-sTeel Joint). It connected PHC Pile by bolt that verification of bolt connection should be accomplished. In this paper, pull-out test and flexural performance for HAT Joint to verifying the bolt connection is explained. As a result, the pull-out and flexural capacities of bolt were checked to use in real structure. Furthermore, the equation of pull-out strength was proposed.
        4,000원
        44.
        2015.08 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        In this study, to confirm the effect of alloying elements on the phase transformation and conditions of the friction stir process, we processed two materials, SS400 and SM45C steels, by a friction stir process (FSP) under various conditions. We analyzed the mechanical properties and microstructure of the friction stir processed zone of SS400 and SM45C steels processed under 400RPM - 100mm/min conditions. We detected no macro (tunnel defect) or micro (void, micro crack) defects in the specimens. The grain refinement in the specimens occurred by dynamic recrystallization and stirring. The microstructure at the friction stir processed zone of the SS400 specimen consisted of an α-phase. On the other hand, the microstructure at the friction stir processed zone of the SM45 specimen consisted of an α-phase, Fe3C and martensite due to a high cooling rate and high carbon content. Furthermore, the hardness and impact absorption energy of the friction stir processed zone were higher than those of base metals. The hardness and impact absorption energy of FSPed SM45C were higher than that of FSPed SS400. Our results confirmed the effect of alloying elements on the phase transformation and mechanical properties of the friction stir processed zone.
        4,000원
        45.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A series of tests was conducted for full-scale single-pylon asymmetric cable-stayed bridges using a system of multiple shaking tables. The 2-span bridge length was 28 m, and the pylon height was 10.2 m. 4 different base conditions were considered: the fixed condition, RB (rubber bearings), LRB (lead rubber bearings), and HDRB (high damping rubber bearings). Based on investigation of the seismic response, the accelerations and displacements in the axial direction of the isolated bridge were increased compared to non-isolated case. However, the strain of the pylon was decreased, because the major mode of the structure was changed to translation for the axial direction due to the dynamic mass. The response of the cable bridge could differ from the desired response according to the locations and characteristics of the seismic isolator. Therefore, caution is required in the design and prediction in regard to the location and behavior of the seismic isolator.
        4,200원
        46.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The finite element stress analysis of large sized rectangular water tank structures made of stainless steel materials is carried out for various combined load cases. The combined load cases for a large size of 5,000ton are further determined using the specification(KS B 6283) established from the Korean Standards Association. The changed water capacity due to the size of reservoirs could be heavily dependent for evaluating seismic effects, especially for large reservoirs. For the better numerical efficiency, the rectangular panels are modelled using the ANSYS ADPL module. The numerical results obtained for different load cases mainly show the effect of the interactions between the different load combination and other various parameters, for example, the water capacity, and different stainless steel materials. The structural performance for various load combinations is also evaluated.
        4,000원
        47.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In Part I, we disccussed of joint between PHC pile and steel column in foundation of large space structures, one prototype of a joint of PHC pile to steel pipe column was suggested on the basis of analytical studies. In this paper, I explain the Joint of PHC pile to steel tube column and more detail of analysis
        4,000원
        48.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To overcome disadvantages of usual spread foundation in large space structure, some prototypes of a joint of the PHC pile to steel pipe column that directly connects a column to a PHC pile are analytically studied. With the consideration of strength requirement and stress concentration of joint of the PHC pile to column, we suggest the most appropriate one.
        4,000원
        49.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we evaluated the chemical and physical properties of structural steel, which is the most basic material for steel structures and reinforcement concrete structures in modern period. We theorized the technical data for the research of technical history of modern heritage structures by analyzing the product system and its quality control of structural steel used in modern historical heritages. The results of this study are as follow; first, the rounded bars were used in most of modern heritage structures. But in the case of Waegwan railroad bridge, the deformed bars were used in spit of not using in Japan after the great earthquake of Kantou. Second, the structural steel was good in terms of quality control, but It has brittle properties because it was not manufactured by heat treatment process.
        4,000원
        50.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Wind turbine tower has a very important role in wind turbine system as one of the renewable energy that has been attracting attention worldwide recently. Due to the growth of wind power market, advance and development of offshore wind system and getting huger capacity is inevitable. As a result, the vibration is generated at wind turbine tower by receiving constantly dynamic loads such as wind load and wave load. Among these dynamic loads, the mechanical load caused by the rotation of the blade is able to make relatively periodic load to the wind turbine tower. So natural frequency of the wind turbine tower should be designed to avoid the rotation frequency of the rotor according to the design criteria to avoid resonance. Currently research of the wind turbine tower, the precise research does not be carried out because of simplifying the structure of the other upper and lower. In this study, the effect of blade modeling differences are to be analyzed in natural frequency of wind turbine tower.
        4,000원
        51.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to increase applicability of high strength steel, HSA800 to the structure. Selected study of structure is to consider high strength steel, and following parts, 1) Tensile member with no consider of buckling, 2) Truss existing both tension and compression members with small slenderness ratio. This studied structure is included tension column hang on to the upper bridge truss. The structure element quantity with apply HSA800 instead of SM570 is reduced about 38.9% of tension column and 29.7% of bridge truss. In addition, the number of element's division is reduced about two sections due to reduction of self weight that the crane is able to lift up. This improves to reduce erection sequence and construction period which can save about a month. All connections are reviewed as welding and bolt. Also, the cost of welding is reduced about 41.3% due to apply HSA800. In conclusion, applying HSA800 to the hanging structure aggressively can secure economic and constructability.
        4,000원
        53.
        2014.04 구독 인증기관·개인회원 무료
        Natural frequency characteristic of Wind turbine tower is important for designing of tower due to guarantee of structural safety of tower. In GL specification, natural frequency of tower should be designed by consideration of blade rotational frequency. Natural frequency characteristic of tower could be changed by mass ratio of RNA-tower, modeling method of blade and angle of blade in idling condition. In this research, natural frequency of tower is analysed by ABAQUS and compared it result according to tower dimension.
        54.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 범용 유한요소프로그램 ANSYS와 ABAQUS를 이용하여 냉간성형강으로 조립한 조립기둥의 전체좌굴과 뒤틀림좌굴에 대한 비선형해석을 위한 모델링 기법을 소개한다. 냉간성형강의 경우 두께가 얇아서 국부좌굴 등 비선형거동을 보이기 때문에 좌굴에 대한 해석에 매우 섬세한 모델링이 필요하다. ANSYS의 내연적정적모델링에 의한 해석은 좌굴 극한점 부근에서 수렴의 문제를 발생하였지만, ABAQUS의 외연적동적모델링의 경우에는 좌굴 및 좌굴이후의 부재 거동에 대해서 안정적인 결과를 제공하였다. 또한 수치해석 결과는 좌굴실험을 통해 얻어진 축내력에 비해 높은 내력을 보여주고 있다. 이는 실험과정에서 발생하는 편심에 의한 영향으로서 수치해석에 의한 좌굴내력에 적정한 보정치의 적용이 필요하며 본논문에서는 기존 실험데이터와의 비교를 통해 0.88의 값을 제시한다.
        4,000원
        55.
        2014.04 구독 인증기관·개인회원 무료
        The paper presents an experimental result to characterize the behaviour of steel beams reinforcement by pultruded reinforced polymer strips. Steel beam members reinforced with different thick AFRP on bottom flange plate were tested under one point bending configuration. Test results showed that the member force of one ply reinforced specimen was increased as 11% than control specimen when the two ply overlapped specimen was increased as 14% as usual.
        56.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The circular hollow section is usually used for member of main frame to carry the external load in single layer lattice dome. But, the H-shaped section may be used for member of main frame since it is convenient for attaching roof panels. Single layer lattice domes have various buckling characteristics, such as the overall buckling, the member buckling, and nodal buckling. The purpose of this study is to compare buckling characteristics of single-layer lattice domes in which the H-shaped steel section as the existing domestically-produced structural steel is used as main frames to those of domes in which a circular hollow section is used as main frames.
        4,000원
        57.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The core aim of this paper is to empirically scrutinize a strength characteristic and ductility of the beam-column frame of reinforced with steel subjected to the cyclic lateral load. First and foremost, I the author embarks upon making four prototypes vis-à-vis this research. Through this endeavour, the author has analysed cyclic behavior, fracture shape, ductility and energy dissipation of the normal beam-column frame and a beam-column frame of reinforced with steel. In addition, the survey has revealed the exact stress transfer path and the destructive mechanism in order to how much a beam-column frame of reinforced with steel has resistance to earthquake regarding all types of building, as well as school construction. To get the correct data, the author has compared the normal beam-column frame and three types of the beam-column frame of reinforced with steel following these works, the characteristic of cyclic behavior, destructive mechanism, ductility, and Energy dissipation of normal beam-column frame and a beam-column frame of reinforced with steel have been examined clearly.
        4,200원
        58.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The research is to verify by experiments whether the steel truss structure is able to withstand the load of cement bricks of upper part of a door for the safe use of lightweight steel truss structure instead of concrete lintel which is to be installed at upper part of door frame in building cement bricks for apartment construction. The steel truss is designed in order not to disturb bricks-building and the shape of structure was verified by bending test. According to experiments result, camber was applied to steel structure that enabled construction work to be improved and was proved effective for the prevention of accidents by cement bricks-building load test.
        4,000원
        59.
        2013.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to evaluate the effectiveness of the seismic retrofit performance for a reinforced concrete structure with steel damper. The nonlinear static analysis of the RC frame specimens with and without retrofit using the steel damper was conducted and the reliability of the analysis was verified by comparing the analysis and test results. Using this analysis model and method, additional nonlinear analysis was conducted considering varying stiffness and strength ratios between RC frame and steel damper and the failure mode of RC frame. As the result of the study, the total absorbed energy increased and the damage of RC frame was reduced as stiffness and strength ratios increased. The seismic retrofit performance, evaluated by means of the yield strength, increasing ratio of the absorbed energy and damage of the frame, increased linear proportionally with the increase of the strength ratio. In addition, the seismic retrofit performance was stable for stiffness ratios larger than 4~5. The energy absorption capacity of the frame governed by shear failure was better than that of the frame governed by flexure failure.
        4,000원
        60.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study a hybrid safety barrier system consisting of steel rail and carbon fiber reinforced polymer (CFRP) post is considered. W hile CFRP post is selected for impact energy reflection due to its high strength, steel rail is selected for impact energy absorption due to its high ductility. A numerical model considering the elastoplastic behavior of steel is formulated to simulate the dynamic responses of the hybrid system subject to an impact load. A hybrid roadside guard rail system of steel rail and CFRP post is proposed and analyzed with a case study. The numerical model for the hybrid roadside guard rail system is used to find optimized design of the proposed hybrid system.
        4,000원
        1 2 3 4 5