검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 65

        42.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The thermal conductivity for the ground heat exchanger installed in the local facilities of greenhouse area at JangSu-Gun in Jeollabuk-Do was analyzed experimentally. For measuring the thermal conductivity of the ground heat exchanger, a bore hole was punched at the size of diameter 150mm, depth 160m. And a closed-type heat exchanger of high density polyethylene at the size of diameter 40mm was installed vertically. The heated water by an electric heater was circulated through the ground heat exchanger with a pump. The inlet/outlet temperatures and the flow rates of this water are measured and the thermal conductivity was calculated. The experimental results were as follows. The inlet/outlet temperatures of the ground heat exchanger were increased rapidly until 7 hours, then they were increased gently and the difference of inlet/outlet temperature was maintained at about 4.5℃. The thermal conductivity calculated by the line source theory was 2.207W/mK.
        4,000원
        43.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the hybrid tube expander unit for fin and tube type heat exchanger are developed by means of enlarging and inserting the smooth tube with a small diameter to a finned tube having larger diameter. In other word, the tube expander tool that is easy to attach and remove from tube is developed. The hybrid tube expander unit developed in this study can move easily and enlarge the tube without fixing at tube sheet. Also, this unit has a function removing scales inside tube by replacing a tube expander ball.
        3,000원
        44.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박에 사용되는 TEMA 열교환기 전열관의 확관 공정에서 발생되는 탄소성 응력과 변형량의 거동을 유한요소법으로 해석하였다. 열교환기의 관판 구명의 홈 깊이와 롤러 익스팬더의 작용압력을 변화시켜 해석한 결과, 전열관의 관판 구멍의 홈 깊이가 커지면 탄소성 압축응력은 감소하였고, 롤러 익스팬더 압력이 높을수록 관판 구멍의 홈 모서리 부분의 탄소성 응력이 증가되었다.
        4,000원
        45.
        2011.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        In this study, an enthalpy exchanger was coated by silver nano particles via spark discharge method and its antimicrobial and heat exchange efficiencies were evaluated. A method utilizing thermophoretic force was used to improve coating efficiency. Four spark discharge systems were parallel connected and generated silver nano aerosol particles (number concentration of 1.65×108 particles/cc, mode diameter of 31 nm). The coating efficiency was evaluated according to various face velocities (V=0.25~1 m/s) and temperature gradients ((Thot-Tcold)/Thot=0~0.09). The maximum coating efficiency was 90.8 % when the face velocity was 0.25 m/s and the temperature gradient was 0.09 (Thot=30℃, Tcold=2℃). Silver nano particles were coated onto the enthalpy exchange element and two different coating amounts of silver nano particles (0.11 ㎍/cm3 , 0.22 ㎍/cm3 ) were tested. For evaluation of antimicrobial efficiency, the suspension test method with E. coli was used. After the suspension test method, CFU(colony forming unit)s of each test sample were counted and colony ratio was calculated. The colony ratio was decreased more quickly when the amount of coated silver particles was increased. When the contact time between each sample and suspension was over 3 hours, antimicrobial efficiencies of coated samples were more over 99.9 % for both amount of silver nano particle(0.11 ㎍/cm3 , 0.22 ㎍/cm3 ). The coating of silver nano particles did not affect the heat exchange efficiency.
        4,600원
        46.
        2009.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A new plate heat exchanger for water-refrigeration systems such as chillers has been developed. Before forming, two stainless steel plates are placed on each other and connected by tig welding. To outline of the plate did the seam welding, in order to form the flow pass on the plate inside the spot welding used. After the plates have been welded, the plates are hydraulically inflated using pressure by water or nitrogen.The plate is made of an SUS plate of 1m×2m in length and 1.2mm in thickness and are fixed in the top of the water tank.As a result of these, it is concluded that the plate exhibits good cooling performance and the average cooling capacity is approximately 2.9RT/plate and the average coefficient of performance (COP) of chiller system is 3.16.
        4,000원
        47.
        2008.11 구독 인증기관 무료, 개인회원 유료
        The LNG carriers have been propelled by steam turbines and the LNG boil-off(BOG) has been used as fuel or vented. However, as the alternative propulsion systems such as diesel engines are being equipped on the LNG carriers for better fuel efficiency, a need for the LNG BOG re-liquefaction system that liquefies the BOG and sends the liquid BOG back to the LNG cargo has arisen in recent years. This study investigates the design of the BOG re-liquefaction system based on the reverse Brayton refrigeration cycle. The thermodynamic and heat exchanger analysis are carried out and the limitations to the system performance are discussed.
        4,000원
        48.
        2007.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The electrophoretic deposition process of Ni nano-particles in organic suspension was employed for self-repairing of heat exchanger tubes. For this purpose, Ni nano-particles prepared by levitational gas condensation method were dispersed into the solution of ethanol with the addition of dispersant Hypermer KD2. For electrophoretic deposition of Ni nano-particles on the Ni alloy specimen, constant electric fields of 20 and 100 V were applied to the specimen in Ni-dispersed solution. It was found that as electrophoretic deposition proceeds, the size of the pit or crack remarkably decreased due to the agglomeration of Ni nano-particles at the pit or crack. This strongly suggests that the electrophoretic mobility of the charged particles is larger for the damaged part with a higher current value rather than outer surfaces with a lower current value.
        4,000원
        50.
        2006.09 구독 인증기관·개인회원 무료
        The electrophoretic deposition process of Ni nano-particles was employed for self-repairing of heat exchanger tubes. For electrophoretic deposition of Ni nano-particles on pitted Ni alloy specimen, a constant electric field of 100 V was applied to the specimen for 180 s in Ni-dispersed solution. It was found that as electrophoretic deposition proceeded, the size of the pit remarkably decreased due to the agglomeration of Ni nano-particles at the pit. This strongly suggests that the electrophoretic mobility of the charged particles is larger for the pit with a higher current value rather than outer surfaces with a lower current value.
        1 2 3 4