        61.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to set up the optimal exposure condition according to detector type considering image quality (IQ) with radiation dose in chest digital radiography. We used three detector type such as flat-panel detector (FP) and computed radiography (CR), and charge-coupled device (CCD). Entrance surface dose (ESD) was measured at each exposure condition combined tube voltage with tube current using dosimeter, after attaching on human phantom, it was repeated 3 times. Phantom images were evaluated independently by three chest radiologists after blinding image informations. Standard exposure condition using each institution was 117 kVp-AEC at FP and 117 kVp-8 mAs at CR, and 117 kVp-8 mAs at CCD. Statistical analysis was performed by One way ANOVA (Dunnett T3 test) using SPSS ver. 19.0. In FP, IQ scores were not significant difference between 102 kVp-4 mAs and 117 kVp-AEC (28.4 vs. 31.1, p=1.000), even though ESD was decreased up to 50% (62.3 μGy vs. 125.1 μGy). In CR, ESD was greatly decreased from 117 kVp-8 mAs to 90 kVp-8 mAs without significant difference of IQ score (p=1.000, 24.6 vs. 19.5). In CCD, IQ score of 117 kVp-8 mAs was similar with 109 kVp-8 mAs (29.6 vs. 29.0), with decreasing from 320.8 μGy to 284.7 μGy (about 11%). We conclude that optimal x-ray exposure condition for chest digital radiography is 102 kVp-4 mAs in FP and 90 kVp-8 mAs in CR, and 109 kVp-8 mAs in CCD.
        4,000원
        62.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A image defect detecting vision system for the automatic optical inspection of wafer has been developed. For the successful detection of various kinds of defects, the performance of two threshold selection methods are compared and the improved Otsu method is adopted so that it can handle both unimodal and bimodal distributions of the histogram equally well. An automatic defect detection software for practical use was developed with the function of detection of ROI, fast thresholding and area segmentation. Finally each defect pattern in the wafer is classified and grouped into one of user-defined defect categories and more than 14 test wafer samples are tested for the evaluation of detection and classification accuracy in the inspection system.
        4,000원
        63.
        2015.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        When a radiation detector is applied to the measurement of the radioactivity of high-level of radioactive materials or the rapid response to the nuclear accident, several collimators with the different inner radii should be prepared according to the level of dose rate. This makes the in-situ measurement impractical, because of the heavy weight of the collimator. In this study, an IRIS collimator was developed so as to have a function of controlling the inner radius, with the same method used in optical camera, to vary the attenuation ratio of radiation. The shutter was made to have the double tungsten layers with different phase angles to prevent the radiation from penetrating owing to the mechanical tolerance. The performance evaluation through the MCNP code was conducted by calculating the attenuation ratio according to the inner radius of the collimator. The attenuation ratio was marked on the outer scale ring of the collimator. It is expected that when a radiation detector with the IRIS collimator is used for the in-situ measurement, it can change the attenuation ratio of the incident photon to the detector without replacing the collimator.
        4,000원
        64.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Fire detectors are designed to minimize loss of life from a fire alarm system as an alarm to help evacuate more quickly until the completion of the evacuation alarm should be continued. the purpose of such alarms in order to achieve the characteristic fire heat release rate reaches a certain level, or when a certain time has elapsed, when the heat detector is to be alarms to answer. Requires a quick response, it is desirable to install the sensor as much as possible, but taking into account the cost of installation problems by engineering approach to minimize the quantity and rapidity of detection capability should be increased. In order to increase the rapidity of fire detectors in a room according to the height of the sensing period is to be maintained the optimum distance of the fire detector detects characteristics should be considered. Differential spot-type heat detectors installed domestic basis, depending on the type of sensor that can detect one sensor area is limited and less than 4m ceiling height regulations and simply double the number in excess of 4m and intended to be installed
        4,200원
        66.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This development is for non-destructive machine using X-Ray source about detecting outline faults of below middle size products. The market share of previous non-destructive machine has three major companies, such as GE, Siemens and Philips. In fact, Korea has a import of this product over 90 percentage. Fortunately, The major companies have not various kinds below middle size non-destructive machine. This machine has superior performance than previous X-Ray equipment in below middle size non-destructive machine. This machine is satisfactory needs for customers looking for X-Ray machine of a line detector. This research is for design and manufacturing of non-destructive X-Ray machine. This research will give rise to major effects for other various non-destructive market industries except car-industry. The most important fact is that this developed non-destructive machine is controlled below 0.2 micro-μSv.
        4,000원
        67.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ammonia is one of typical index substances of environmental odor. This study describes a rapid and simpleadsorption tube type detector to be able to measure the level of strict emission standards with quantitativeconcentration of gaseous ammonia as the regulations are enhanced. a gas detector tube can be measured theammonia gas concentration of 0.23ppm, 0.5ppm, 1ppm, 1.5ppm and 2ppm through the relation between theSampling rate Kog (=DA/L) and the discoloration reaction rate by physico-chemical analysis. Also this study canbe predicted the relation between the sampling volume and the sampling time. and it can be designed to measuringthe range of various concentrations. In this case study, an optimum design was found with an sampling rate, 42ml/min and with a tube diameter, 3.0mm. Adsorption and diffusion rate was evaluated by Fick's law.
        4,000원
        68.
        2014.02 구독 인증기관 무료, 개인회원 유료
        This development is non-destructive machine using X-Ray source about detecting outline faults of small-middle products. This machine is supplement of previous X-Ray equipment. This machine is satisfaction of needs for customers using X-Ray machine of a line detector for weakness. This research is for design and manufacturing of X-Ray apparatus. This machine is measuring below a meter. This research is a major ripple effect for other industries except car-industry.
        4,000원
        69.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 가속된 이온이 전기장이 걸려있는 freestanding 단결정 실리콘 나노 박막에 충돌했을 때 발생하는 열-전계 전자 방출 특성을 여러 전계 및 열적 조건 아래 체계적으로 분석하였다. 이온 충돌에 의한 열-전계 전자 방출은 쇼트키 효과 (schottky effect)의 선형영역의 특성에 의해 예측된 바와 같이 전계의 세기가 증가할수록 선형적으로 증가했으며, 이온 충돌에 의해 발생하는 열에너지의 제곱에 비례하는 특성을 보여주었다. 이러한 특성들은 실리콘 나노 박막의 질량 분석기용 이온 검출기로의 사용 가능성을 보여준다.
        4,000원
        70.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to analyze the accuracy of estrus detection of heat detector and analysis of estrus behavior (mounting and mounted), and the evaluation of conditions required for improving reproductive efficiency in Holstein dairy cows fitted with a estrous detector. The heat detection system consists of estrous detector based on wireless sensor and an electric bulletin board displayed estrus behavior data. When cow mounting other cows, the accuracy of estrus behavior displayed an electric bulletin board were 87.5% (mounting other cows only), 100% (mounting other cows but not standing), 80.0% (mounting other cows with standing for 1∼4 seconds), 90.0% (mounting other cows but not standing for 1∼4 seconds), 80% (mounting other cows with standing for more than 5 seconds) and 90.0% (mounting other cows but not standing for more than 5 seconds). When cow mounted other cows, the accuracy of estrus behavior displayed an electric bulletin board were 100% (mounted other cows but not standing), 100% (mounted other cows with standing for 1∼4 seconds), 100% (mounted other cows but not standing for 1∼4 seconds) and 100% (mounted other cows with standing for more than 5 seconds). Circadian distribution of first observed in estrus were 59.1% (am 8∼pm 6) and 40.9% (pm 6∼am 8). Distribution for the number of estrus behavior were 40.9% (less than 3 times), 36.4% (4∼6 times) and 22.7% (more than 4 times). The conception rates relative to interval from first estrus behavior to insemination for estrus periods were 23.1% (less than 11 hours) and 55.6% (12∼20 hours).
        4,000원
        73.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 차량검지기의 속도측정 성능평가방법을 개발하였다. 개발된 성능평가방법에서는 오차요인들을 기준속도에 반영하며 측정불확도의 개념을 적용하였다. 기존연구, 통계적 처리기법, 기존교통단속장비 및 차량검지시스템의 속도측정 성능평가방법 등에 대한 고찰을 통해 기존평가방법의 문제점을 도출하고 개선된 성능평가방법을 개발하였다, 실제 현장에 설치된 차량검지기에 대해서 기존평가방법과 개발방법을 적용해본 결과 기존평가방법은 평가기준에 적합하나 개발방법은 평가기준을 만족시키지 못하고 있다. 이러한 결과는 기존성능평가방법이 측정 시의 오차요인들을 충분히 고려하지 못해서 평가대상장비의 성능을 고평가할 가능성이 있음을 의미하며, 반면에 개발모형은 측정 시의 변동요인인 오차를 고려하므로 기존평가방법 보다 정확함을 나타낸다.
        4,000원
        74.
        2011.11 구독 인증기관 무료, 개인회원 유료
        The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.
        4,000원
        77.
        2011.09 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to compare the accuracy analysis and the effect of field application of a newly developed automatic heat detector in dairy cows. From 2009 to 2010, we used 48 Holstein cows (mounting cows : 38 heads, standing cows : 10 heads) raised in experimental barn of National Livestock Research Institute (RDA) for the accuracy analysis of automatic heat detector, and 14 Holstein cows raised in three commercial dairy farms of Cheonan and Pochun area for comparison of the effect of field application. The accuracy of response in cows attached with automatic heat detector was 86.8% (33/38) displayed on board when mounting activity observed, and 100% (10/10) when standing activity observed, and on average, 90.0% (43/48) displayed on board. The accuracy of automatic heat detector in on-farm test was 85.7% (12/14), and conception rate was 75.0% (9/12).
        3,000원
        78.
        2011.06 구독 인증기관 무료, 개인회원 유료
        본 논문은 독거노인 또는 부정맥 환자의 24시간 응급감시 모니터링을 위해 광소자를 이용한 독거노인 위험감지형 맥박센서를 설계했다. 투과형의 광소자를 사용한 맥박 측정 센서는 상용 기술이지만, 이것은 의료 기관에서 환자나 환자 진료 모니터링을 위한 일회성 측정 방법이다. 때문에 일상생활에서 무구속의 지속적인 측정이 가능한 센서 개발이 필요하며, 또한 내구성과 편의성, 유동성에 대한 신뢰성과 안정성을 유지해야한다. 이러한 조건에서 우리는 손목시계 타입의 독거노인 위험감지형 맥박 센서를 설계하고, 실험 결과에서 그 가능성을 확인했다.
        4,000원