검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 220

        81.
        2010.12 구독 인증기관 무료, 개인회원 유료
        Recent apartment houses tend to expose the problems of unbalanced floor temperatures and real temperature due to changes in thermal performance arising from reinforced insulation and air tightness. In this study, the indoor thermal environment was analyzed against the apartment unit household in the type of individual heating, central heating, and District Heating methods in order to determine the operational status of indoor thermal environments and heating system by Heating supply systems. The temperature of hot water supplied at the time the indoor loads occurs to the maximum by Heating supply systems was found to rise in order to individual heating (70℃) , central heating(47℃) and District Heating (41℃). The hot water supply frequency showed variable changes in the range of 3 to 6 times per day in cases of individual heating while periodical changes was ranging from 3 or 4 times a day in the case of central heating and district heating. The width of variation of floor surface temperatures depending on the temperature of the supply water was found to be in order of Individual Heating, District Heating, and Central Heating. The average floor surface temperature appeared similar to the hot water supply temperature pattern in the order of 26.4 to 30.2℃ for Individual Heating, 28.2 to 28.6℃ for Central Heating, and 24.8 to 29.4℃for District Heating. In the case of non-heating where heating is not implemented, the temperature of the floor surface was 22.8℃ to 26.0℃ showing the same temperature as the indoor temperature. Heating supply appeared to be maintained in a stable manner overall in a sporadic manner ranging from 3 to 6 times a day, which was maintained in a stable manner on the whole regardless of the heating method.
        4,500원
        83.
        2010.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 합리적인 단지 내 도로포장의 표준단면을 제시하기 위해 국내외 단지 내 도로포장 설계기준, 주요 파손형태를 조사하고 다양한 포장설계 단면을 대상으로 구조해석을 수행하였다. 이때, 현장에서 사용된 보조기층재와 노상토의 시편을 채취하여 CBR 및 MR 시험을 실시하였으며, 측정한 물성치를 구조해석에 적용하였다. 다양한 현장조건을 고려한 구조해석 결과를 분석하여, 표준단면의 포장층 두께를 보조기층 20cm, 아스팔트기층 5cm, 그리고 표층 5cm로 제안하였다. 또한, 민원이 예상되는 도시지역에서는 일반적으로 아스팔트 기층을 포설한 후 공사차량을 개방하여 작업종료 후에 표층을 포설하게 되는데 이러한 여건을 고려하여 단지 내 아스팔트 콘크리트 포장 표준단면의 포장층의 두께를 보조기층 20cm, 아스팔트 기층 7cm, 그리고, 표층 5cm로 제시하였다.
        4,000원
        84.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the uAPSS(u-APartment Service System) that is based on location-aware technology is designed and implemented for a luxury apartment. On the real luxury apartment the developed system has been employed and tested to provide convenient and secure living for residents. It provides services such as emergency call, intelligent elevator operation, and hands-free door access based on the location of the residents with personal device as called smart tag. It can also be applied to other service areas such as the location-aware u-Service for hospitals, high-rising complex buildings, silver towns, etc.
        4,000원
        87.
        2009.09 구독 인증기관 무료, 개인회원 유료
        For new construction, recently, it has expended from physical performance standard to completed apartment' blemish warranty and countermeasure strategy contents. And considering element technology is increasing remodeling’ easiness for deciding operation right or wrong the aged apartment’ re-construction or remodeling. In addition, international standardization of building performance makes rapid progress the point of ISO. In Japan, study of housing commission will be done on a national level for the long commission metropolitan gathering house construction and reproduction technical development, and, already, involving study of approval system of building element made progress. It set the goal performance log index of remodeling’ easiness, it set up component element between a part and public standard type in remodeling. In plan and design phase, it is a precondition that make the performance on the basis of user demand in the whole of Use, maintenance, repair, waste and reuse. Therefore, in the building technology case that development of element technology and practical use are fast in progress, a user is required to evaluate/choice according to performance. And a developer is required to the technical development that aim performance is cleared. The study selected a detailed item about performance item of re-modeling element technique through the requirement which the nations (such as America, England, Japan, etc) and the agencies of foreign countries present and item selection standard, from the point of view where the interest not only the individual but also govemmental politic viewpoint is coming to be higher re-modelling than new construction.
        4,000원
        88.
        2009.03 구독 인증기관 무료, 개인회원 유료
        Earthquake is one of the hazard so hard to provide because it is difficult predicted occurred time, scale and characters. Neighbors which have damaged by earthquake look out for statement of damage, It is bigger than nation which has not prepared seismic code at ordinary time seismic damage which belong to loss of life. The earthquake in Kobe, Japan showed that the damages were concentrated on the buildings which were not considered to be protected from the earthquakes. Seismic code applied structures was small damaged but non applied structures was much damaged such as collapse and loss of life. In this study, apartment structures in Korea analyze about earthquake hazard and evaluate seismic performance. Through the this study we have notice of earthquake hazard for apartment structures which live a lot of population of Korea and suppose necessary for seismic retrofit.
        4,000원
        89.
        2008.09 구독 인증기관 무료, 개인회원 유료
        The existing apartment supplied in large quantities in the 1970-80s has a problem of superannuation today. It is at a wornout management means. I can consider Build& and remodeling. However, in the case of remodeling, they are being social and an economical and environmental advantage. It can be said that it is better than Build&. Research of a book is research on a Remodeling ease evaluation system. Remodeling was realized by the technique and construction method which re-design based on the existing apartment,take in the component engineering, and improve the function and performance of a building. if it sees in a certain viewpoint, the development and spread of remodeling technology need to be managed like logical approach of the existing building where the remodeling fishing port planning division also gets, and is applied. The ease of remodeling is estimated by two sides. Remodeling Feasibility is evaluated by two aspects. The first is Macro Level Approach of Remodeling Feasibility Evaluation on a Apartment Complex, and The second is Micro Level Approach of Remodeling Feasibility on each housing part is evaluated about removal and dismandement.
        4,000원
        90.
        2008.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study aims to present the fundamental strategies for improving the Indoor Air Quality ( IAQ ) in newly unoccupied apartment units. The results of this study can be summarized as follows, The field survey of 160 newly unoccupied units with airtight doors and windows showed that the concentrations of HCHO and TVOC were higher than the standards. The emission rates of HCHO and TVOC were proportional to the height. The small chamber test of pollutant concentration for building materials showed that pollutants were emitted dominantly from the wood furnishings and adhesives.
        4,300원
        91.
        2008.03 구독 인증기관 무료, 개인회원 유료
        The renovation project of an apartment building can be classified into four processes: ordering the project stage, planning stage, examination and judgment stage, design stage and construction stage. However, in the domestic renovation business, the project performance process has yet to be madε systematic by stage. Of the stages involved in renovation, the design stage is the one that involves very complex roles and business processes of those involved in the project, including the project manager, architect,resident and engineer. In particular, in the design stage, the insufficiency in the ability to utilize the input information by project participants and improper decision making cause various problems in the subsequent construction and ultimately make it difficult to accomplish a renovation project that fully satisfies the residents. Therefore, the design of renovation is a very important stage to ensure a comprehensive understanding of the project performance process as well as the recognition of the design management technology. For this purpose, we aim to analyze the information utilization process with focus on the input information at each stage of the design process. The information utilization process of this study is analyzed through the processes of input information, technical tools and output to establish a decision-making method for each design stage. The aim was to implement the project performance process for the general design management.
        4,000원
        92.
        2007.09 구독 인증기관 무료, 개인회원 유료
        It is high that occupancy rate of apartment house in Korea, spite of short history of the using multiple dwelling house. So that, trouble and dispute occurs often on right or responsibility, liability and obligation about ownership, Utilization, maintenance. Especially in renovation project, the project progress held up in perception gap or conflict of interest with residents. These dispute in daily life and delay of project occurs ambiguous borderline or distinction of Common Used(Sharing) Parts) and Exclusive Possessed (Private) Parts. The law now in force is considered in this paper about theses item. Summarizing the conclusion is as below. 1) In the law now in force the literal meaning of a word, Exclusive Possessed (Private) Parts is expressed with concept of Ownership, But Common Used (Sharing) Parts is described with Utilization concept. But in calculation of floor area, complementary set of Private Parts is Sharing Parts. This is contradiction in logic and linguistic. 2) Although above, calculation base of Private Parts is inner line of exterior wall. This is unjustly defined. 3) Especially about balcony (in correct architectural vocabulary is veranda) subordinate law contradictits superordinate law. And in structural mechanics also, minute prescription is necessary about Private Parts and Sharing Parts.
        4,000원
        93.
        2007.09 구독 인증기관 무료, 개인회원 유료
        A standard RC apartment structure was analysed using commercial structural analysis program MIDAS. The effects of TLD were considered by equivalent tuned mass damper model and harmonic load of wmch frequency was identical to that of the RC structure and artificial earthquake loads generated accroding to the design spectrum in KBC2005 were used as excitation loads. TLD showed maximally 70% reduction of peak/RMS relative displacement, interstory drift, acceleration, and story shear induced by harmonic load while it reduced about 20~28% of those structural responses excluding absolute acceleration induced by artificial earthquake loads.
        4,000원
        94.
        2007.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The vascular plants of the studied area in this site was listed as 231 taxa; 68 families , 166 genera, 202 species, 26 varieties, 2 forms and 1 cultivar. Naturalized plants was listed as 22 taxa; 9 families , 17 genera , 20 species , 2 varieties and naturalization rate was 9.5% of all 231 taxa vasccular plants. The planted plant in this site were recorded 23 taxa (Ginkgo biloba,Cerdrus deodara, Chamaecyparis obtusa, Pseudosasa japonica, Salix preudolasiogyne, Magnolia denudata, Eucommia ulmoides,Hibiscus syriacu,etc.) and cultivated plants were recorded 26 taxa (Sorghum bicolor, Colocasia antiquorum var‘ esculenta, Spinada oleracea, Ridnus communis, Malva verticillata, Solanum tuberosum, Cucumis sativus, Chrysanthemum coronarium ver. spatiosun. The plants community of this site were classified to 6 communities, they were Pinus densif]ora community. Castanea crenata community. Robinia pseudoacada community. Phyllostachys bambusoides community. Pinus rigida community. Quercus acutissima community.
        4,300원
        95.
        2006.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study was carried out to evaluate the characteristics of volatile organic compounds (VOCs) and aldehydes emission as a function of airtight time in new apartment. Sampling was undertaken at 34 new apartments located in 4 different cities of Korea from February to November 2005. The measurement data were collected every one hour from 10 a.m. to 6 p.m. toward increasing airtight time in a day. The concentrations of VOCs and aldehydes were analysed by GC/MS and HPLC method, respectively. These methods showed good sensitivity, linearity, and repeatability. In this study, the most abundant compounds at new apartments appeared to be toluene, m,p-xylene, formaldehyde and acetone. Moreover, the concentration variations at a closed rooms progressively increased by airtight time of 5 hours. Airtight time of new apartment was a most important and affective factor which influenced concentration change.
        4,300원
        96.
        2006.09 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        For indoor air quality at a newly built apartment before move-in, we monitored formaldehyde and VOCs and assessed human exposure and probabilistic health risk. We selected 801 newly built apartments all over the country. The results of the research on the condition show the mean concentrations of formaldehyde 294 ㎍/㎥, 210(median) 1497㎍/㎥(maximum), benzene 6㎍/㎥, (4 and 92㎍/㎥), toluene 1003㎍/㎥(773 and 5013 ㎍/㎥), ethylbenzene 120㎍/㎥, (62 and 1192㎍/㎥), xylene 287㎍/㎥(138 and 2723㎍/㎥) and styrene 64㎍/㎥, (42 and 531㎍/㎥). Formaldehyde from carcinogen and toluene and xylene from non-carcinogen were assessed the risk for human health. The excess cancer risk of formaldehyde for human beings between carcinogens is per 1.36 of average 1000 persons. This implies that it is over a level per 1.00 of 1000 persons demanding active risk reduction. Hence, we strongly need the active reduction plan and accurate source assumption. Among a variety of factors affecting indoor air quality for householders, closing construction or density of indoor air processing additional interior construction and indoor area, indoor air quality with a variety of districts show significant. The excess cancer risk for human beings of formaldehyde between carcinogens is per 1.36 of average 1000 persons. Non-carcinogen toxicity rate for human-beings with toluene and xylene among non-carcinogens is over HQ 1 from Seoul to local area.
        4,500원
        97.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        아파트의 온돌 바닥판은 콘크리트 바닥판위에 경량기포 모르타르, 완충재, 마감 모르터가 복층으로 시공되어 콘크리트 바닥판 상부의 시공방법 및 재료에 의한 구조적 거동에 대한 영향이 다르게 나타난다. 따라서 보다 합리적인 아파트의 콘크리트 적층 바닥판의 진동평가를 위해서는 시공방법 및 재료를 고려한 새로운 개선된 진동핵석 모델이 요구된다. 본 논문에서는 실제아파트의 적층으로 시공된 콘크리트 바닥판에 대한 보다 합리적인 진동해석 방법을 제안하고자 한다.
        4,000원
        98.
        2006.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper is concerned with the natural periods of ambient vibration and eigenvalue analysis. Ambient vibration tests were conducted to four bearing-wall reinforced concrete buildings ranging from twelve to nineteen stories. The performance of modeling in eigenvalue analysis was investigated using consideration of rigidity out of the plane in the slab and the non-structural bearing wall. Measured natural period was also compared with the value by the KBC2005. Natural period of the short direction in eigenvalue analysis is well fitted with the measured one. In the other hand, Natural period of the long direction in eigenvalue analysis is slightly more overestimated than the measured one. Natural period of the long direction in eigenvalue analysis was found to be enhanced by considering the effect of the stiffness out of the plane of the slab and non-structural wall in the structural modeling.
        4,000원
        99.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Building materials are composed of very complex chemical compounds. The aims of this paper are to investigate the emission concentrations of indoor pollutants from new apartment house and the emission variation patterns during 75 days. The average value of total volatile organic compounds(TVOCs) concentration was 3,768 ㎍/㎥ in five new apartments. Major VOCs included toluene, ethylbenzene, m,p-xylene and o-xylene. The average concentrations of each compound were measured as : benzene(58㎍/㎥), toluene (793㎍/㎥), ethylbenzene(438㎍/㎥), styrene(79㎍/㎥), m,p-xylene(1,210㎍/㎥), o-xylene(364㎍/㎥). The results indicated that the major VOCs from the new apartment were affected by building products such as on aromatic hydrocarbon compounds. TVOCs emission are characterized as high emission level at initial time (12,856㎍/㎥) and decreased through time. After a lapse of 75 days in sample house, TVOCs concentration decreased in about 20 times as compared with the initial concentration. The TVOCs emission profiles strongly depended on the generation mode and the concentration of the VOCs in building material.
        4,500원
        100.
        2006.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the concentration of aldehydes from new apartments in three cities(Suncheon, Yeosu, and Gwangyang) of Chonnam region. The target apartments were within 3 months after the completion of construction. Aldehydes were sampled using 2,4-DNPH cartridge and analyzed by HPLC. Temperature and relative humidity were monitored continuously every one minute by digital temperature and hygrometer. As the concentration ratio of formaldehyde between back-up and front cartridge was 3.94 6.97%, the 2,4-DNPH cartridge method satisfied a breakthrough problem for the sample collection. The repeatability of retention time and peak area for HPLC were excellent as 0.5 and 1.5%, respectively. The upper floor of S apartment (16 pyong) showed the highest concentration of formaldehyde as 1,093㎍/㎥. The average concentration of formaldehyde was the highest in K apartment(52 pyong) as 1,045㎍/㎥. The average concentration of formaldehyde in S apartment(16 pyong) and C apartment(25 pyong) were 872.6㎍/㎥ and 737.5㎍/㎥, respectively. The I/O ratios of formaldehyde were 56.9 60.0(mean : 59.1), 37.9 43.3(mean : 39.8) and 18.3 29.3(mean : 23.3) in K, C and S apartment, respectively. Therefore, it is believed that the indoor concentration of formaldehyde was very serious in new apartment. From these results, it is important that building material which emit low indoor pollutant should be selected for new apartments. In addition, management program for indoor air, such as using an adequate amount of adhesives, should be considered and indoor optimum condition should be maintained in new apartments.
        4,300원
        1 2 3 4 5